首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A highly selective mercury electrode based on a diamine donor ligand   总被引:1,自引:0,他引:1  
Gupta VK  Chandra S  Lang H 《Talanta》2005,66(3):575-580
(H2NCHMeCH2NH2)(H2O)2HgCl2 (I) was synthesised, characterised and used for the fabrication of a potentiometric sensor for Hg2+ metal ions. Membrane having I as electroactive material, sodium tetraphenyl borate (NaTPB) as an anion excluder, dibutylamine (DBA) as plasticizer in PVC matrix in the percentage ratio of 10:3:150:150 (I:NaTPB:DBA:PVC) (w/w) exhibits a linear response to Hg2+ ions in a concentration range of 1.25 × 10−5 to 1.0 × 10−1 M having a detection limit of 8.9 × 10−6 with a slope of 25 ± 0.1 mV over the pH range 6.6-9.3. Selectivity coefficients for Hg(II) relative to a number of interfering ions were investigated. The electrode is highly selective for Hg2+ ions over a large number of mono-, bi-, and trivalent cations. Normal interferents like Ag+ and Cd2+ do not interfere in the working of the electrode. The electrode has also been used successfully in mixtures having a 10% (v/v) methanol and acetone content without showing any considerable change in working concentration range or slope. These electrodes have been found to be chemically inert showing a fast response time of 10 s and were used over a period of 4 months with good reproducibility (s = ±0.2). The electrode was used for determination of mercury in binary mixtures with 100% recovery and thus the proposed sensor can be used for real sample analysis.  相似文献   

2.
Singh AK  Saxena P  Mehtab S  Gupta B 《Talanta》2006,69(2):521-526
A new PVC membrane electrode based on 5,7,12,14-dibenzo-2,3,9,10-tetraoxa-1,4,8,11-tetraazacyclotetradecane (I) as an ion carrier, o-nitrophenyloctyl ether (o-NPOE) as solvent mediator and sodium tetraphenylborate (NaTPB) as lipophilic additive was fabricated and investigated as Sr2+-selective electrode. The best performance was exhibited by the membrane having composition 8:200:4:120 (I:o-NPOE:NaTPB:PVC). The electrode exhibited a Nernstian response for strontium ion over a wide concentration range 3.98 × 10−6 to 1.0 × 10−1 M with a slope of 29.0 ± 0.1 mV/decade of concentration and a detection limit of 2.82 × 10−6 M. It showed a response time of less than 10 s and could be used for at least 3 months without any divergence in potential. The proposed electrode showed a good discriminating ability towards strontium(II) ion over a wide variety of other metal ions including alkali, alkaline earth, transition, and heavy metal ions. The electrode can be used in the pH range of 2.5-10.5 and in mixtures containing up to 35% (v/v) non-aqueous content. It was used as an indicator electrode in potentiometric titration of strontium ion against EDTA.  相似文献   

3.
The potentiometric response characteristics of mercury ion-selective membrane electrodes based on 2-amino-6-purinethiol (I1) and 5-amino-1, 3, 4-thiadiazole-2-thiol (I2) were described. Ion selectivities were tested for various plasticizers, which were used as solvent mediators to incorporate the ionophores into the membrane. Effects of experimental parameters such as membrane composition, nature and amount of plasticizers and additives, pH and concentration of internal solution on the potential response of Hg2+ electrodes were investigated. The best performance was obtained with the electrode having a membrane composition (w/w) of (I1) (3.17%): PVC (31.7%): DOP (dioctylpthalate) (63.4%): NaTPB (sodium tetraphenylborate) (1.58%). The proposed electrode reveals a Nernstian response over Hg2+ ion in the concentration range of 7.0 × 10−8-1.0 × 10−1 M with limit of detection 4.4 × 10−8 M. The electrode shows good discrimination toward Hg2+ ion with respect to most common cations. It shows a short response time (10 s) for whole concentration range and can be used for 2 months without any considerable divergence in potentials. For evaluation of the analytical applicability, the electrode was used in the determination of Hg2+ ion in different environmental and biological samples. The practical utility of the membrane electrode has also been observed in the presence of surfactants.  相似文献   

4.
The two macrocyclic pendant ligands 3,4,5:12,13,14-dipyridine-2,6,11,15-tetramethyl-1,7,10,16-tetramethylacrylate-1,4,7,10,13,16-hexaazacyclooctadeca-3,13-di ene (L1) and 3,4,5:12,13,14-dipyridine-2,6,11,15-tetramethyl-1,7,10,16-tetra(2-cyano ethane)-1,4,7,10,13,16-hexaazacyclooctadeca-3,13-diene (L2) have been synthesized and explored as neutral ionophores for preparing poly(vinylchloride) (PVC) based membrane sensors selective to Tb(III) ions. Effects of various plasticizers and anion excluders were studied in detail and improved performance was observed. The best performance was obtained for the membrane sensor having a composition of L1: PVC:1-CN:NaTPB in the ratio of 6: 32: 58: 4 (w/w; mg). The performance of the membrane based on L1 was compared with polymeric membrane electrode (PME) as well as with coated graphite electrode (CGE). The electrodes exhibit Nernstian slope for Tb3+ ions with limits of detection of 3.4 × 10−8 mol L−1 for PME and 5.7 × 10−9 mol L−1 for CGE. The response time for PME and CGE was found to be 10 s and 8 s, respectively. The potentiometric responses are independent of the pH of the test solution in the pH range 3.0-7.5 for PME and 2.0-8.5 for CGE. The CGE has found to work satisfactorily in partially non-aqueous media upto 30% (v/v) content of methanol, ethanol and 20% (v/v) content of acetonitrile and could be used for a period of 5 months. The CGE was used as indicator electrode in the potentiometric titration of Tb3+ ions with EDTA and in determination of fluoride ions in various samples. It can also be used in direct determination of Tb3+ ions in tap water and various binary mixtures with quantitative results.  相似文献   

5.
Comparative studies of neodymium (III)-selective PVC membrane sensors   总被引:1,自引:0,他引:1  
Sensors based on two neutral ionophores, N,N′-bis((1H-pyrrol-2-yl)methylene)cyclohexane-1,2-diamine (L1) and 3,3′-(cyclohexane-1,2-diylbis(azan-1-yl-1-ylidene)bis(methan-1-yl-1-ylidene)bis(5-hydroxymethyl)pyridine-2-ol) (L2) are described for quantification of neodymium (III). Effect of various plasticizers; 2-nitrophenyloctylether (o-NPOE), dibutyl butylphosphonate (DBBP), tri-n-butyl phosphates (TBP), dioctylpthalate (DOP) and chloronapthalen (CN) and anion excluder, sodiumtetraphenylborate (NaTPB) has been studied. The membrane composition of PVC:o-NPOE:ionophore (L1):NaTPB (w/w; mg) of 150:300:5:5 exhibited best performance. The sensor with ionophore (L1) exhibits significantly enhanced selectivity towards neodymium (III) in the concentration range 5.0 × 10−7 to 1.0 × 10−2 M with a detection limit of 1.0 × 10−7 M and a Nernstian compliance (19.8 ± 0.3 mV decade−1 of activity) within pH range 4.0-8.0. The response time of sensor was found as 10 s. The influence of the membrane composition and possible interfering ions has also been investigated on the response properties of the electrode. The fast and stable response, good reproducibility and long-term stability of the sensor are observed. The sensor has been found to work satisfactorily in partially non-aqueous media up to 20% (v/v) content of methanol, ethanol or acetonitrile and could be used for a period of 3 months. The selectivity coefficients determined by using fixed interference method (FIM) indicate high selectivity for neodymium. The proposed electrode shows fairly good discrimination of neodymium (III) from other cations. The application of prepared sensor has been demonstrated in the determination of neodymium (III) in spiked water samples.  相似文献   

6.
N,N′,N″,N′′′-1,5,8,12-tetraazadodecane-bis(salicylaldiminato)(H2L) has been used as ionophore for preparing Mn2+ selective sensor. Membranes of different composition with regard to ratio of H2L:PVC:NPOE:NaTPB have been prepared and investigated. The best performance was obtained with the membrane of composition 10:150:150:10 (H2L:PVC:NPOE:NaTPB) (w/w; mg). This membrane generated linear potential response in the concentration range of 5.0 × 10−6 to 1.0 × 10−1 M with a Nernstian slope of 30.0 mV/decade of activity and fast response time (10 s). Hydrogen ion does not effect to the performance of sensor in the pH range 3.0-6.5. The sensor was found to be sufficient selective for Mn2+ over a number of alkali, alkaline and heavy metal ions and could therefore be used for the determination of manganese in various samples by direct potentiometry.  相似文献   

7.
Gupta VK  Agarwal S 《Talanta》2005,65(3):730-734
PVC based membranes of 5,10,15,20-tetrakis(4-methoxyphenyl)porphyrinatocobalt(II) (TMOPP-Co) (I) as electroactive material with dibutyl butyl phosphonate (DBBP), dioctyl phthalate (DOP), 1-chloronaphthalene (CN), tri-n-butyl phosphate (TBP) and tris(2-ethylhexyl) phosphate (TEP) as plasticising solvent mediators have been prepared and tried for arsenite determination. The membrane having a composition 150:5:150 (PVC:I:DBBP) exhibited the best results with linear potential response in the concentration range of 7.9 × 10−5 to 1.0 × 10−1 M of AsO2 with a slope of 28.8 mV/decade. The useful pH range of the sensor is 6.0-10.5. The membrane worked satisfactorily in non-aqueous medium up to 5% (v/v) non-aqueous content. The selectivity coefficient values for mono- and divalent anions indicate good selectivity for arsenite over a large number of anions.  相似文献   

8.
The two chromium chelates of Schiff bases, N-(acetoacetanilide)-1,2-diaminoethane (L1) and N,N′-bis(acetoacetanilide)-triethylenetetraammine (L2), have been synthesized and explored as neutral ionophores for preparing poly(vinylchloride) (PVC) based membrane sensors selective to Cr(III). The addition of lipophilic anion excluder (NaTPB) and various plasticizers viz. o-Nitrophenyloctyl ether (o-NPOE), dioctylpthalate (DOP), dibutylphthalate (DBP), tris(2-ethylhexyl)phosphate (TEHP), and benzyl acetate (BA) have found to improve the performance of the sensors. The best performance was obtained for the membrane sensor having a composition of L1:PVC:DBP:NaTPB in the ratio 5:150:250:3 (w/w). The sensor exhibits Nernstian response in the concentration range 8.9 × 10−8 to 1.0 × 10−1 M Cr3+ with limit of detection 5.6 × 10−8 M. The proposed sensor manifest advantages of relatively fast response (10 s) and good selectivity over some alkali, alkaline earth, transition and heavy metal ions. The selectivity behavior of the proposed electrode revealed a considerable improvement as compared to the best previously PVC-membrane electrode for chromium(III) ion. The potentiometric response of the proposed sensor was independent of pH of the test solution in the range of 2.0-7.0. The sensor has found to work satisfactorily in partially non-aqueous media up to 20% (v/v) content of methanol, ethanol and acetonitrile and could be used for a period of 3 months. The proposed electrode was used as an indicator electrode in potentiometric titration of chromium ion with EDTA and in direct determination in different water and food samples.  相似文献   

9.
One reaction system of Cu2+, dipn, and CN with two different molar ratio sets of 1:1:5, and 2:1:8 produced two compounds 1 [CuII(dipn)][CuII(CN)4], and 2, respectively (dipn = dipropylenetriamine). Their structures were determined by X-ray crystallography. Compound 2 is built from Cu(I) and Cu(II) centers, which are bridged by cyanide groups and metal-metal bonds. The magnetic properties of 1 and 2 were investigated in 2-300 K. Compound 1 exhibits an antiferromagnetic exchange interaction between copper(II) ions mediated by cyano-bridges.  相似文献   

10.
Gupta VK  Prasad R  Kumar A 《Talanta》2004,63(4):1027-1033
Membrane incorporating [Mg{(TAP)(SBn)8}] complex, (I), as ionophore with composition I:NaTPB:DOP:PVC in the ratio 10:2:133:200 (w/w) exhibits the best result for potentiometric sensing of Mg2+ ions. This gives linear potential response in the concentration range of 9.4×10−6 to 1.0×10−1 M with a slope of 29.2±0.4 mV per decade of activity of Mg2+. Standard deviation in observed values of potentials in this concentration range, from the least square fit line, found to be 2.91 mV with 90% confidence limit lying within ±0.4 mV per decade of activity. The electrode works satisfactorily in the pH range 3.5-7.8 and shows a fast response time of 13±2 s. It shows good selectivity for Mg2+ over other mono-, bi- and tri-valent cations. Only K+ and Zn2+ cause slight interference if present at concentrations ≥1.0×10−5 M. The electrode is durable and can be used over a period of 5 months with good reproducibility (∼1% error). It has been successfully used as an indicator electrode in potentiometric titration of Mg2+ against EDTA as well as for the determination of Mg2+ in simulated mixtures.  相似文献   

11.
Praseodymium ion selective polyvinyl chloride (PVC) membrane sensors, based on two new Schiff's bases 1,3-diphenylpropane-1,3-diylidenebis(azan-1-ylidene)diphenol (M1) and N,N′-bis(pyridoxylideneiminato) ethylene (M2) have been developed and studied. The sensor having membrane composition of PVC: o-NPOE: ionophore (M1): NaTPB (w/w; mg) of 150: 300: 8: 5 showed best performances in comparison to M2 based membranes. The sensor based on (M1) exhibits the working concentration range 1.0 × 10−8 to 1.0 × 10−2 M with a detection limit of 5.0 × 10−9 M and a Nernstian slope 20.0 ± 0.3 mV decade−1 of activity. It exhibited a quick response time as <8 s and its potential responses were pH independent across the range of 3.5-8.5.The influence of the membrane composition and possible interfering ions have also been investigated on the response properties of the electrode. The sensor has been found to work satisfactorily in partially non-aqueous media up to 15% (v/v) content of methanol, ethanol or acetonitrile and could be used for a period of 3 months. The selectivity coefficients determined by using fixed interference method (FIM) indicate high selectivity for praseodymium(III) ions over wide variety of other cations. To asses its analytical applicability the prepared sensor was successfully applied for determination of praseodymium(III) in spiked water samples.  相似文献   

12.
13.
14.
Palladium sensors based on two neutral ionophores, N,N′-bis(acetylacetone) cyclohexanediamine (L1) and N,N′-bis(o-hydroxyacetophenone)-1,2-cyclohexanediamine (L2) for quantification of palladium ions are described. Effect of various plasticizers (o-NPOE, DBP, DEP, DOP, TBP, and CN) and anion excluder, sodium tetra phenyl borate (NaTPB) has been studied. The best performance is obtained with a membrane composition of PVC:o-NPOE:ionophore (L1):NaTPB of 150:300:5:5 (%, w/w). The sensor exhibits significantly enhanced selectivity towards palladium ion over the concentration range 1.0 × 10−8 to 1.0 × 10−1 M with a lower detection limit of 4.0 × 10−9 M and a Nernstian compliance (29.1 ± 0.3 mV decade−1 of activity) within pH range 2.0-6.0 and fast response time of 10 s. Influence of the membrane composition and possible interfering ions has also been investigated on the response properties of the electrode. Fast and stable response, good reproducibility and long-term stability of the sensor are demonstrated. The sensor has been found to work satisfactorily in partially non-aqueous media up to 20% (v/v) content of methanol, ethanol and acetonitrile and could be used for a period of 4 months. Selectivity coefficients determined with fixed interference method (FIM) indicate high selectivity for palladium. The proposed electrode shows fairly good discrimination of palladium from other cations. The application of prepared sensor has been demonstrated in determination of palladium ions in spiked water sample.  相似文献   

15.
Three different N-donors L, namely N-ethyl-N′-3-pyridyl-imidazolidine-4,5-dione-2-thione (1), N,N′-bis(3-pyridylmethyl)-imidazolidine-4,5-dione-2-thione (2), and tetra-2-pyridyl-pyrazine (3), bearing one, two and four pyridyl substituents, respectively, have been reacted with halogens X2 (X = Br, I) or interhalogens XY (X = I; Y = Cl, Br). CT σ-adducts L · nXY, bearing linear N?XY moieties (L = 3; X = I; Y = Br, I; n = 2), and salts containing the protonated cationic donors HnLn+ (L = 1 − 3; n = 1, 2, 4), counterbalanced by Cl, Br, , , , , I2Br, , or anions, have been isolated. Among the reactions products, (H1+)Cl, (H1+)Br, , , and 3 · 2IBr have been characterised by single-crystal X-ray diffraction. The nature of the products has been elucidated based on elemental analysis and FT-Raman spectroscopy supported by MP2 and DFT calculations.  相似文献   

16.
Novel ionophore, C-thiophenecalix[4]resorcinarene (I) has been synthesized and characterized by IR, NMR and C, H, N analysis. Poly(vinyl chloride) (PVC) based membranes of ionophore (I) using dibutylphthalate (DBP), dioctylphthalate (DOP), 1-chloronapthalene (CN), tris(2-ethylhexyl) phosphate (TEHP) and bis(2-ethylhexyl)sebacate (DOS) as plasticizing solvent mediators were prepared and used as Cr selective sensors. Of the various sensors prepared, the one with membrane composition 2:66:120 mg (I: PVC: DBP) exhibited the best performance. This sensor works well over a wide concentration range 5.6 × 10−6-1.0 × 10−1 M (detection limit ∼ 0.30 ppm) with Nernstian compliance (29.0 mV per decade) between pH 6.5-10.0 with a fast response time of ∼13 s. The selectivity coefficient values as determined by fixed interference method (FIM) indicate excellent selectivity for Cr ions over a large number of anions. The sensor exhibits adequate shelf-life ( ∼5 months) with good reproducibility (S.D. ± 0.2 mV). The sensor has been used in the potentiometric titration of chromate with Pb(II). Determination of chromium in electroplating waste using the sensor was successfully achieved.  相似文献   

17.
Two entangled compounds [(bpy)6CuI6Cl3(MoVW5O19)] (1) and [(bpy)7CuI7Cl2(BW12O40)]·H2O (2) (bpy=4,4′-bipyridine), have been successfully synthesized under hydrothermal conditions and characterized by element analysis, IR spectroscopy, thermal gravimetric analysis, X-ray photoelectron spectroscopy, and single crystal X-ray diffraction analyses. Compound 1 represents the first eight-connected self-penetrating network constructed from cuprous chloride clusters [Cu6Cl3] and Lindquist-type polyoxoanions. Compound 2 exhibits an interesting fivefold interpenetrating network consisting of Keggin polyoxoanions and Cu+-metal-organic framework. Crystal data of the two compounds are following: 1, triclinic, , a=11.502(2) Å, b=13.069(3) Å, c=13.296(3) Å, α=90.55(3)°, β=113.74(3)°, γ=110.48(3)°, Z=1; 2, triclinic, , a=12.341(3) Å, b=13.119(3) Å, c=15.367(3) Å, α=99.12(3)°, β=90.53(3)°, γ=104.49(3)°, Z=1.  相似文献   

18.
19.
Chemosensors 5-7 possessing a quaternary ammonium cation (for electrostatic interactions) and an N-H group(s) (for H-bonding) as recognition sites and an anthracene-9,10-dione as both a chromogenic and fluorescent moiety exhibit absorption and emission changes with fluoride ions only. No significant response to other anions such as Cl, Br, I, , CH3COO, , and is observed. The dual emission at λmax 580 nm (free 5/6) and λmax 510 and 540 nm (5/6 + F) in chemosensors 5 and 6 enables ratiometric analysis of fluoride ions.  相似文献   

20.
Ion-selective properties were established for membrane electrodes prepared by using organotin compounds of type (LCNRSnF2)n, (R = n-Bu (I), = Ph (II)) and (LCNSnF3)n (III) (LCN = C6H4(CH2NMe2)-2). Electrodes formulated with the optimized membranes containing the organotin compounds I-III as ionophores and sodium tetraphenylborate (10-30%) exhibited high selectivity for fluoride over other anions. An electrode prepared with ionophore II using dibutyl phthalate as the plasticizer and 15% sodium tetraphenylborate (NaTPB) as anion additive, possesses the best potentiometric response characteristics. It shows a detection limit of 7.9 × 10−7 M with a slope of 62.7 mV decade−1 of activity in buffer solutions of pH 5.5. The interference from other anions is suppressed under this optimized measurement conditions. An entirely non-Hofmeister selectivity sequence (F > CH3COO > Cl > I ∼ Br >ClO4 > NO2 > NO3 > SCN) with remarkable preference towards fluoride is obtained. The influence on the electrode performances by anion additive was studied, and the possible response mechanism was investigated by UV-vis spectra. The electrode has been used for direct determination of fluoride in drinking mineral water with satisfactory results.  相似文献   