首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A new direct microwave desorption–gas chromatography‐mass spectrometry method was developed for the analysis of the essential oils of medicinal plants. A homemade direct microwave desorption system was fabricated and used for the desorption of volatile components of medicinal herbs. The desorbed volatiles are transferred directly into the gas chromatography injector for analysis in a one‐step process. Approximately 0.3 g of the herb was needed for the desorption of samples in 60 s. In this study, more than 53 volatile compounds were identified and quantified for Echinophora platyloba DC as model herb sample. The results were found to be in good agreement with the conventional hydrodistillation extraction data. The described results show that direct microwave desorption is fast, simple, and easy to automate and requires only a small amount of sample. The results indicate that essential oil components valuable for varietal identification and characteristic of each variety analyzed when direct microwave desorption–gas chromatography‐mass spectrometry was used for analysis.  相似文献   

2.
Improvements in the methylmercury extraction from human hair by solid-phase microextraction followed by gas chromatography coupled to cold-vapour atomic fluorescence spectrometry (GC-CVAFS) have been carried out. They consisted in the optimisation of the digestion step prior to the aqueous-phase ethylation and in the GC-CVAFS interface set-up. The main digestion parameters such as acid type, concentration, temperature and time have been optimised for hair sample analysis, thereby avoiding methylmercury degradation. Moreover, the stability of the digested samples was evaluated to improve the sample throughput.  相似文献   

3.
Method qualification is a key step in the development of routine analytical monitoring of pharmaceutical products. However, when relying on published monographs that describe longer method times based on older high‐performance liquid chromatography column and instrument technology, this can delay the overall analysis process for generated drug products. In this study, high‐throughput ultrahigh pressure liquid chromatography techniques were implemented to decrease the amount of time needed to complete a 24‐run sequence to identify linearity, recovery, and repeatability for both drug assay and impurity analysis in 16 min. Multiple experimental parameters were tested to identify a range of experimental settings that could be used for the sequence while still maintaining this fast analysis time. The full sequence was replicated on a different system and with different columns, further demonstrating its robustness.  相似文献   

4.
C Scherer  U Wachter  S A Wudy 《The Analyst》1998,123(12):2661-2663
A method for the determination of testosterone in human hair by gas chromatography-mass spectrometry using d3-testosterone as internal standard is described. Our method consisted of alkaline digestion, fast liquid-liquid extraction, LH-20 chromatography and derivatization with heptafluorobutyric anhydride. Quantification was achieved by selected ion monitoring of m/z 680 (testosterone) and m/z 683 (d3-testosterone). Our method needed no complex corrections for isotope contributions. The procedure provided a sensitive and specific technique with good accuracy and precision. For the first time, testosterone has been quantified by gas chromatography-mass spectrometry in human hair. The concentrations (median, range, ng g-1 hair) reflected a significant (p = 0.05; t-test) sex difference with 2.7 ng g-1 (2.5-4.2) in male and 1.7 ng g-1 (1.0-3.4) in female hair.  相似文献   

5.
Simultaneous distillation–extraction (SDE) is routinely used by analysts for sample preparation prior to gas chromatography analysis. In this work, a new process design and operation for microwave assisted simultaneous distillation–solvent extraction (MW-SDE) of volatile compounds was developed. Using the proposed method, isolation, extraction and concentration of volatile compounds can be carried out in a single step. To demonstrate its feasibility, MW-SDE was compared with the conventional technique, SDE, for gas chromatography-mass spectrometry (GC-MS) analysis of volatile compounds in a fresh aromatic herb, Zygophyllum album L., a wild salty desert herb belonging to the family Zygophyllaceae. SDE method required a long time (3 h) to isolate the volatile compounds, and large amounts of organic solvent (200 mL of hexane) for further extraction, while MW-SDE needed shorter time (only 30 min) to prepare the sample, and less amount of organic solvent (10 mL of hexane). These results show that MW-SDE–GC-MS is a simple, rapid and solvent-less method for the determination of volatile compounds from aromatic plants.  相似文献   

6.
Abstract

Three extraction methods, acidic KBr/CuSO4 isolation-methylene chloride extraction. acidic KBr/CuSo4 isolation-methylene chloride extraction with an alkaline digestion pretreatment, and an extration method at a milder condition with citrate buffer and dithizone in chloroform, were studied for methylmercury and ethylmercury determination in soils, sediments and fish samples by the recently developed capillary gas chromatography—atomic fluorescence spectrometry system (GC-AFS). The acidic KBr/CuSO4-methylene chloride extraction and the acidic KBr/CuSO4-methylene chloride extraction with an alkaline digestion pretreatment were shown to be the effective methods for soils/sediments and fish samples analysis, respectively. The presence of ethylmercury species in soils of the Florida Everglades, observed with the acidic KBr/CuSO4 isolation and methylene chloride extraction procedure, was further confirmed with the dithizone complexation/extraction procedure. The GC-AFS analytical method offers high senstivity and selectivity for the determination of organomercury halides. The GC column maintenance, a critical step for organomercury halides analysis using GC, is also discussed.  相似文献   

7.
Benzene, toluene, ethylbenzene, and xylenes are some of the most hazardous constituents found in commercial gasoline samples; therefore, these components must be monitored to avoid toxicological problems. We propose a new routine method of ultrafast gas chromatography coupled to flame ionization detection for the direct determination of benzene, toluene, ethylbenzene, and xylenes in commercial gasoline. This method is based on external standard calibration to quantify each compound, including the validation step of the study of linearity, detection and quantification limits, precision, and accuracy. The time of analysis was less than 3.2 min, with quantitative statements regarding the separation and quantification of all compounds in commercial gasoline samples. Ultrafast gas chromatography is a promising alternative method to official analytical techniques. Government laboratories could consider using this method for quality control.  相似文献   

8.
The analysis of semivolatile organochlorines (polychlorinated biphenyls and chlorinated pesticides) in less polluted biomaterials requires specific strategies in controlling the blank in sample preparation. The procedure described here allows to decrease significantly the level of contamination during the clean-up step of fish oil. Solid-phase-extraction (SPE) on LiChrolut EN and normal phase HPLC in the normal- and the backflush-mode were used to reduce the amount of solvents needed and the analysis time compared to established clean-up procedures. With a certified reference material (BCR-CRM 349; Cod Liver Oil) the precision and effectiveness of the new method were validated. Recovery rates of the Internal Standards (PCB 103 and TCN) lay between 75% and 90% at the microg/kg lipid level. The quantitative analyses were carried out by high resolution gas chromatography with electron capture detector (HRGC-ECD).  相似文献   

9.
The present determination of selenium in biological matrices by HPTLC with in situ fluorimetric detection is an accurate alternative method, comparable to other established methods such as photometry, polarography, neutron activation, or X-ray fluorescence analysis, gas chromatography, and atomic absorption spectrometry. The excellent sensitivity of this procedure is proved by the detection limit of 250 fg of selenium per spot (using purified 2,3,1-naphthoselenodiazole). The oxidation of organic matrices, applying a novel digestion procedure, may be carried out with little instrumental expenditure. Sample preparation steps, such as the oxidation of selenium to Se (VI) and subsequent reduction to Se (IV) do not lead to significant random or systematic errors, nor does the digestion step, if an optimized procedure is used. A recovery rate of 103% and nearly parallel calibration curves for digested selenocysteine standards compared with spiked human serum samples demonstrate the accurate quantitative preparation of a biological matrix. Any interfering metal ions can be masked by addition of chelate-forming reagents.  相似文献   

10.
A novel one-step sample preparation technique termed ultrasound-microwave hybrid-assisted extraction coupled to headspace solid-phase microextraction (UMHE-HS-SPME) was developed in this study, which was used for the determination of essential oils in dry traditional Chinese medicine (TCM) based on gas chromatography–mass spectrometry. The dry roots of Angelica dahurica were used as the model TCM. In this work, ultrasound-assisted extraction was first combined with microwave-assisted extraction coupled to headspace solid-phase microextraction and applied to the rapid determination of A. dahurica. Sample preparations including isolation, extraction, and concentration of essential oils were performed in a single step. The effects of various parameters including fiber coating, ultrasound power, and irradiation time were investigated thoroughly and optimized. To further demonstrate the method’s feasibility, the conventional steam distillation (SD) method was used for the analysis of essential oils in the TCM to compare with the proposed method. The results show that more essential oil compounds were isolated and identified by UMHE-HS-SPME than by SD. Moreover, compounds with higher boiling point and many more oxygenated compounds were extracted from A. dahurica by the proposed method. In addition, the SD method required a long time (6 h) to isolate the essential oils, and large amounts of organic solvent for further extraction, while UMHE-HS-SPME needed only 10 min to prepare the samples, and no organic solvent. Relative standard deviation values less than 10 % show that the present method has good precision. According to the experimental results, the advantages of the proposed method are: short extraction time, high extraction efficiency, and solvent-free extraction. Thus, UMHE-HS-SPME is an alternative tool for fast analysis of essential oils in dry TCMs and can be potentially extended to other target analytes in dry matrix.  相似文献   

11.
A multiresidue method using gas chromatography coupled to ion-trap tandem mass spectrometry (MS/MS) was developed for the analysis of 27 pesticides, commonly used in Alsace, in atmospheric samples (particle and gas phases). As pesticides are expected to be present at very low concentrations and in a complex matrix, the analytical method used was both highly selective and sensitive. These two properties were obtained by associating chromatography with ion-trap MS/MS. To develop this method, analysis of electron impact in single MS was first conducted to choose the parent ions of the pesticides studied. Among the 27 pesticides analysed, seven of them require a derivatisation step. This was the case of some ureas (chlorotoluron, diuron and isoproturon), phenoxy acids (2,4-dichlorophenoxyacetic acid, 4-chloro-2-methylphenoxyacetic acid and mecoprop) and of bromoxynil. The derivatisation was performed with success with pentafluorobenzylbromide. Then, a MS/MS method was optimised by parameters such as the radio frequency storage level and the collision-induced dissociation excitation voltage. Finally, a last step enabled the development of two calibrating programs based on the quantification of daughter ions for the 20 pesticides analysed directly (run 1) and for the seven pesticides which needed derivatisation (run 2). With this analytical procedure, the detection limits varied between 2.5 and 1,250 pg m–3 depending on the compounds studied. This method was tested with success for atmospheric samples collected in Strasbourg (France) during intensive pesticide treatment in 2002.  相似文献   

12.
The precise quantitative analysis of biomass sugars is a very important step in the conversion of biomass feedstocks to fuels and chemicals. However, the most accurate method of biomass sugar analysis is based on the gas chromatography analysis of derivatized sugars either as alditol acetates or trimethylsilanes. The derivatization method is time consuming but the alternative high-performance liquid chromatography (HPLC) method cannot resolve most sugars found in biomass hydrolysates. We have demonstrated for the first time that by careful manipulation of the HPLC mobile phase, biomass monomeric sugars (arabinose, xylose, fructose, glucose, mannose, and galactose) can be analyzed quantitatively and there is excellent baseline resolution of all the sugars. This method was demonstrated for standard sugars, pretreated corn stover liquid and solid fractions. Our method can also be used to analyze dimeric sugars (cellobiose and sucrose).  相似文献   

13.
A ‘suspect screening analysis’ method for grape metabolomics by ultra‐high performance‐liquid chromatography (UHPLC) and high‐resolution quadrupole‐time of flight (QTOF) mass spectrometry was recently developed. This method was applied to study grape monoterpene glycosides, the main grape aroma precursors. Since standard compounds were not available, they were tentatively identified by overlapping various analytical approaches, in agreement with the indications recommended in mass spectrometry (MS)‐based metabolomics. Accurate mass and isotopic pattern, MS/MS fragmentation, correlation between fragments observed and putative structures and between liquid chromatography coupled with mass spectrometry (LC/MS) and gas chromatography/mass spectrometry signals were studied. Seventeen monoterpene glycosides were identified without performing the hydrolytic artifacts commonly used to study these compounds which may affect sample profile. This is the first time that a detailed study of these aroma precursors has been carried out by direct LC/MS analysis. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

14.
BDE-209 is the predominant constituent of the commercial mixture decabromodiphenyl ether which is used as brominated flame retardant (BFR). Owing to difficulties associated with the high mass (thermal instability and low vapour pressure), short GC columns (≤15?m) have been suggested for its analysis while longer columns (30–50?m) are suggested for other polybrominated diphenyl ether (PBDE) congeners. To overcome this considerable expenditure in the analysis of PBDEs, we aimed at increasing the sensitivity of BDE-209 analysis by gas chromatography coupled with electron-capture negative ion mass spectrometry (GC/ECNI-MS) on a 30?m column. The chromatographic performance of BDE-209 on the 30?m GC column was improved by increasing the carrier gas flow from initially 1.2?mL?min?1 to 5 or 10?mL?min?1 after the last octabromo diphenyl ether (Br8DE) congener was eluted. With this high carrier gas flow, the column residence time of BDE-209 was shortened by ~25%, the peak height was increased and, consequently, the limit of detection by GC/ECNI-MS in selected ion monitoring (SIM) mode was improved. When this high-flow GC/ECNI-MS-SIM method was applied to a sediment sample, we realized that gel permeation chromatography (GPC) – used for the removal of lipids and/or sulphur – provided low recovery rates for BDE-209. The large molecule BDE-209 eluted late and only 50% was recovered by our previous standard protocol for polyhalogenated compounds. Application of a modified GPC procedure with a longer collection time increased the recovery of BDE-209 in the GPC step to ~90%.  相似文献   

15.
In this study a new type of immobilized metal ion affinity chromatography resin for the enrichment of carbohydrates and polyols was synthesized by radical polymerization reaction of vinyl phosphonic acid and 1,4‐butandiole dimethacrylate using azo‐bis‐isobutyronitrile as radical initiator. Interaction between the chelated trivalent lanthanide ions and negatively charged hydroxyl groups of carbohydrates and polyols was observed by applying high pH values. The new method was evaluated by single standard solutions, mixtures of standards, honey and a more complex extract of Cynara scolymus. The washing step was accomplished by acetonitrile in excess volumes. Elution of enriched carbohydrates was successfully performed with deionized water. The subsequent analysis was carried out with matrix‐free laser desorption/ionization–time of flight mass spectrometry involving a TiO2‐coated steel target, especially suitable for the measurement of low‐molecular‐weight substances. Quantitative analysis of the sugar alcohol xylitol as well as the determination of the maximal loading capacity was performed by gas chromatography in conjunction with mass spectrometric detection after chemical derivatization. In a parallel approach quantum mechanical geometry optimizations were performed in order to compare the coordination behavior of various trivalent lanthanide ions. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

16.
The analysis of persistent organic pollutants in foodstuffs has become necessary for control of their levels in products for human and animal consumption. These analytical procedures usually require a fractionation step in order to separate the different families of pollutants to avoid interferences during the instrumental determination. In this study the separation was carried out on a 2-(1-pyrenyl)ethyl silica column, where analyte fractionation was based on differences in planarity and aromaticity. The fractionation of several types of persistent organic pollutants found in fish oil samples was studied; the pollutants included polychlorinated dibenzo-p-dioxins and dibenzofurans, polychlorinated biphenyls, polybrominated diphenyl ethers, and some organochlorine pesticides. Fractions were analyzed by high-resolution gas chromatography with electron-capture detection and high-resolution gas chromatography–high resolution mass spectroscopy. Finally, the whole method (including the purification, fractionation, and instrumental determination steps) was validated and successfully applied to the analysis of several samples of fish oil.  相似文献   

17.
Gao M  Yu W  Zhang Y  Yan G  Deng C  Yang P  Zhang X 《The Analyst》2008,133(9):1261-1267
We present a comprehensive method for proteome analysis that integrates both intact protein separation and proteolytic fragment characterization mass spectrometric approaches. Strong cation exchange chromatography (SCX) was used as the first separation dimension and capillary reversed-phase liquid chromatography (cRPLC) was integrated as the second separation dimension. Fractions from SCX were collected offline and loaded onto cRPLC. Effluents from cRPLC were directly deposited onto the MALDI target plates and further digested by using a rapid on-probe tryptic digestion technique. This approach minimizes the amount of time and extensive labor required for traditional in-solution digestion followed by exhaustive sample cleanup and transfer. MALDI-TOF/TOF was used for subsequent analyses. The sensitivity of on-target digestion is showed by analyzing 0.07 ng of myoglobin, 0.07 ng of cytochrome c and 0.7 ng BSA. The high efficiency of the overall system was demonstrated by the analysis of intact proteins extracted from normal human liver tissue. In total, 458 proteins were identified, which proved the system's promising potential for analysis and application in proteomics.  相似文献   

18.
采用碱消解土壤溶液提取土壤溶液中的六价铬,用离子色谱(IC)进行分离,有效避免了高盐及焰色反应的干扰,电感耦合等离子体质谱(IC P-M S)法进行检测.研究了消解液使用量、消解温度、消解时间等因素,测定结果和火焰原子吸收光谱(FAAS)法进行对比.结果表明,当称样量为5.0 g,消解液40.0 mL,磷酸缓冲溶液0....  相似文献   

19.
Fatty acid ethyl esters are the main components of rum aroma and play an important sensorial impact in these distilled alcoholic beverages. Herein, a method for analysing these volatile compounds is described. It involves a separation and concentration step using headspace solid-phase microextraction and determination by capillary gas chromatography using flame ionisation detection. The influence of different parameters related to the isolation and concentration step, such as ethanol concentration, ionic strength, sample volume, time and temperature of extraction, was studied. The developed method enabled recoveries >91% for the analyzed compounds with limits of detection between 0.007 and 0.027 mg/l, all of them lower than the range of concentrations found in rum samples. The method was successfully applied to the analysis of fatty acid ethyl esters in different commercial white rums.  相似文献   

20.
Microwave-assisted digestion permits a rapid and total dissolution of sediments and various other sample types, allowing easier and more accurate multi-element determinations. In this study, we present an optimised microwave digestion method for the complete digestion of 200 mg of carbonate-rich sediments. The optimised method prevents the formation of precipitates and assures a complete dissolution of the material. The optimised method involves treatment with concentrated hydrochloric acid (HCl) prior to microwave digestion, which prevents the formation of an insoluble calcium fluoride precipitate associated with the use of hydrofluoric acid (HF). Three different certified reference samples along with a pure calcium carbonate standard and a carbonate-rich in-house marine sediment sample were considered. Sediments were found to only be partially digested if insufficient HF was present, while a noticeable fluoride-based precipitate was found if excess HF was present. Twenty elements were analysed using sector field inductively coupled plasma mass spectrometry (ICP-MS) (Al, Ag, Ba, Ca, Cd, Co, Cr, Cu, Fe, Mg, Mn, Mo, Na, Ni, Sr, Th, Ti, U, V and Zn). A total sample digestion with average elemental recoveries above 90% was obtained by reacting carbonate-rich samples with HCl on a hotplate at 150°C for 2 h (time for the total release of generated CO2), prior to any microwave digestion step. This extra step prevented the accumulation of gas in the sealed vessels during digestion, which would otherwise influence the carbonate chemical equilibria and make insoluble calcium available for precipitation. After this initial treatment, the improved digestion method consisted of microwave attack employing a mix of concentrated HCl, nitric acid (HNO3) and HF (4 mL/10 mL/2 mL), followed by evaporation on a hotplate. The limits of detection (LOD) obtained using the optimised microwave protocol and ICP-MS measurements were below 0.1 µg/kg for the trace elements and below 0.2 mg/kg for major elements.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号