首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 265 毫秒
1.
A high-throughput solid-phase microextraction (SPME) on 96-well plate together with gas chromatography–mass spectrometry (GC–MS) was developed for the determination of some selected pesticides in cucumber samples. Pieces with the length of 1.0 cm of silicon tubing were precisely prepared and then coated on the end part of stainless steel wires. The prepared fibers were positioned in a home-made polytetrafluoroethylene (PTFE)-based constructed ninety-six holes block to have the possibility of simultaneous immersion of the SPME fibers into the center of individual wells. Pesticides such as diazinon, penconazol, tebuconazol, bitertanol, malathion, phosalone and chlorpyrifos-methyl were selected for their highly application in cucumber field. The performances of the SPME fibers, such as intra and inter-fibers reproducibility, were evaluated and the results showed a good similarity in extraction yields. A volume of 1 mL of the aquatic supernatant of the cucumber samples was transferred into the 96-well plate and the array of SPME fibers was applied for the extraction of the selected pesticides. The important parameters influencing the whole extraction process including, organic solvent percent, salt addition, dilution factor, stirring rate and extraction time were optimized. The inter- and intra-day RSD% were found to be less than 15.4%. Limits of detection (LOD) and limits of quantification (LOQ) were below 60 and 180 μg kg−1, respectively. The coefficient of determination was satisfactory (r2 > 0.99) for all the studied analytes. The developed method was successfully applied to the monitoring of several samples gathered from local markets.  相似文献   

2.
A high‐throughput micro‐solid‐phase extraction device based on a 96‐well plate was constructed and applied to the determination of pesticide residues in various apple samples. Butyl methacrylate and ethylene glycol dimethacrylate were copolymerized as a monolithic polymer and placed in the cylindrically shaped stainless‐steel meshes of 96‐micro‐solid‐phase extraction device and used as an extracting unit. Before the micro‐solid‐phase extraction, microwave‐assisted extraction was employed to facilitate the transfer of the pesticide residues from the apple matrix to liquid media. Then, 1 mL of the aquatic samples was transferred into the 96‐well plate and the 96‐micro‐solid‐phase extraction device was applied for the extraction of the selected pesticides. Influential parameters, such as sorbent‐to‐sorbent reproducibility, microwave‐assisted extraction time, ionic strength and micro‐solid‐phase extraction time, were optimized. The limits of quantitation were below 120 μg/kg, which are lower than the maximum residue limits. The developed method was successfully implemented for the extraction and determination of the selected pesticides from 20 different apple samples gathered from local markets. Phosalone was identified and quantified at the concentration level of 147 (±16.4) μg/kg in one of the samples.  相似文献   

3.
We describe a simple and sensitive porous polypropylene membrane-protected micro-solid-phase extraction (μ-SPE) approach for the sample preparation and determination of carbamate pesticides in soil samples by high-performance liquid chromatography. The μ-SPE device consisted of C18 sorbent held within a porous polypropylene envelope. In order to achieve optimum performance, several extraction parameters were optimized. Under the most favorable conditions, the extraction efficiency of the μ-SPE was very high, with detection limits in the range of 0.01–0.40 ng g−1. This is more than two orders of magnitude lower than the limits obtained by the United States Environmental Protection Agency Methods 8321A and 8318. A linear relationship was obtained for each analyte in the range of 2 and 200 ng g−1. The relative standard deviation for the analysis of aged soil samples spiked at 5 ng g−1 was ≤11%. The reproducibility of separate μ-SPE device used for experiments was satisfactory (relative standard deviations ranged from 4 to 11%), indicating that the method is reliable for routine environmental analysis.  相似文献   

4.
A single-step extraction-cleanup method, including microwave-assisted extraction (MAE) and micro-solid-phase extraction (μ-SPE), was developed for the extraction of ten organophosphorus pesticides in vegetable and fruit samples. Without adding any polar solvent, only one kind of non-polar solvent (hexane) was used as extraction solvent in the whole extraction step. Absorbing microwave μ-SPE device, was prepared by packing activated carbon with microporous polypropylene membrane envelope, and used as not only the sorbent in μ-SPE, but also the microwave absorption medium. Some experimental parameters effecting on extraction efficiency was investigated and optimized. 1.0 g of sample, 8 mL of hexane and three absorbing microwave μ-SPE devices were added in the microwave extraction vessel, the extraction was carried out under 400 W irradiation power at 60 °C for 10 min. The extracts obtained by MAE-μ-SPE were directly analyzed by GC–MS without any clean-up process. The recoveries were in the range of 93.5–104.6%, and the relative standard deviations were lower than 8.7%.  相似文献   

5.
A micro-solid-phase extraction (μ-SPE) device was developed by filling copper(II) isonicotinate coordination polymer (Cu(4-C5H4N-COO)2(H2O)4) into a porous polypropylene envelope, and the μ-SPE, coupling with gas chromatography (GC) with a micro-cell electron capture detector (μ-ECD), was used for extraction and determination of PBDEs in soils. Variables affecting extraction procedures, including temperature, water volume, extraction time, and desorption time, were investigated in a spiked soil, and the parameters were optimized. Under the optimal experimental conditions, the method detection limits for seven PBDEs (BDE-28, 47, 99, 100, 153, 154, and 183) were in the range of 0.026–0.066 ng g−1, and the reproducibility was satisfactory with the relative standard deviation in range of 1.3–10.1%. Good linear relationship between PBDEs concentrations and GC signals (defined as peak area) was obtained in the range between 0.1 and 200 ng g−1. The recovery of the seven PBDEs by μ-SPE varied from 70 to 90%, which was comparable to that determined by accelerated solvent extraction method. Finally, the proposed method was used to determine PBDEs in several field-contaminated soils, and it was suggested that the μ-SPE is a promising alternative microextraction technique for the detection of PBDEs in soils.  相似文献   

6.
Graphene is a good adsorbent for organic pollutants, especially for compounds containing benzene rings. When used in TiO2 nanotube arrays for micro-solid phase extraction (μ-SPE), the combination of graphene’s strong adsorptive properties with its good separation capabilities results in excellent sample preconcentration performance. In the present study, graphene-modified TiO2 nanotube arrays were prepared by electrodeposition using a cyclic voltammetric reduction method. Four carbamate pesticides, including metolcarb, carbaryl, isoprocarb, and diethofencarb, were used as model analytes to validate the enrichment properties of the prepared adsorbent in μ-SPE. Factors affecting the enrichment efficiency of the μ-SPE procedure were optimized and included sample pH, elution solvents, salting-out effect, adsorption time and desorption time. Under optimal conditions, graphene-modified TiO2 nanotube arrays exhibited excellent enrichment efficiency for carbamate pesticides. The detection limits of these carbamate pesticides ranged from 2.27 to 3.26 μg L−1. The proposed method was validated using four environmental water samples, and yields of pesticides recovered from spiked test samples of the four analytes were in the range of 83.9–108.8%. These results indicate that graphene-modified TiO2 nanotube arrays exhibit good adsorption to the target pollutants, and the method described in this work could be used as a faster and easier alternative procedure for routine analysis of carbamate pesticides in real water samples.  相似文献   

7.
In the present study, a natural sorbent based micro-solid phase extraction (μ-SPE) was developed for determination of phthalate esters in milk samples. For the first time, an efficient and cost effective natural material (seed powder of Moringa oleifera) was employed as sorbent in μ-SPE. The sorbent was found to be naturally enriched with variety of functional groups and having a network of interconnected fibers. This method of extraction integrates different steps such as removal of proteins and fatty stuff, extraction and pre-concentration of target analytes into a single step. Thirteen phthalate esters were selected as target compounds for the development and evaluation of method. Some key parameters affecting the extraction efficiency were optimized, including selection of membrane, selection and amount of sorbent, extraction time, desorption solvent, volume of desorption solvent, desorption time and effect of salt addition. Under the optimum conditions, very good linearity was achieved for all the analytes with coefficient of determinations (R2) ranging between 0.9768 and 0.9977. The limits of detection ranged from 0.01 to 1.2 μg L−1. Proposed method showed satisfactory reproducibility with relative standard deviations ranging from 3.6% to 10.2% (n = 7). Finally, the developed method was applied to tetra pack and bottled milk samples for the determination of phthalate esters. The performance of natural sorbent based μ-SPE was better or comparable to the methods reported in the literature.  相似文献   

8.
A procedure involving the simultaneous performance of liquid–liquid microextraction and polypropylene microporous membrane solid-phase extraction was carried out. The applicability of the proposed procedure was evaluated through extraction of several organochlorine pesticides from river water, tomato and strawberry samples. The parameters affecting the extraction efficiency were optimized by multivariable designs, and the analytical features were estimated. Under optimized conditions, analytes were concentrated onto 1.5 cm long microporous membranes placed directly into the sample containing 15 mL of water with 20 μL of 1-octanol. The best extraction conditions were achieved at 59 °C, with 60 min of extraction time and 2.91 g of sodium chloride. The desorption of the analytes was carried out using 30 μL of a mixture of toluene and hexane in the proportion of 60:40% (v/v) for 10 min. Detection limits in the range of 2.7–20.0 ng L−1, 0.50–1.15 μg kg−1, and 1.53–12.77 μg kg−1 were obtained for river water, strawberry and tomato samples, respectively. Good repeatability was obtained for all three sample types. The results suggest that the proposed procedure represents a very simple and low-cost microextraction alternative rendering adequate limits of quantification for the determination of organochlorine pesticides in environmental and food samples.  相似文献   

9.
In this paper, a novel graphene (G) based solid-phase microextraction (SPME) fiber was firstly prepared by immobilizing the synthesized G on stainless steel wire as coating. The new fiber possessed a homogeneous, porous and wrinkled surface and showed excellent thermal (over 330 °C), chemical and mechanical stability, and long lifespan (over 250 extractions). The SPME performance of the G-coated fiber was evaluated in detail through extraction of six pyrethroid pesticides. Although the thickness of G-coated fiber was only 6-8 μm, its extraction efficiencies were higher than those of two commercial fibers (PDMS, 100 μm; PDMS/DVB, 65 μm). This high extraction efficiency may be mainly attributed to huge delocalized π-electron system of G, which shows strong π-stacking interaction with pyrethroid pesticide. The G-coated fiber was applied in the gas chromatographic determination of six pyrethroids, and their limits of detection were found to be ranged from 3.69 to 69.4 ng L−1. The reproducibility for each single fiber was evaluated and the relative standard deviations (RSDs) were calculated to be in the range from 1.9% to 6.5%. The repeatability of fiber-to-fiber and batch-to-batch was 4.3-9.2% and 4.1-9.9%. The method developed was successfully applied to three pond water samples, and the recoveries were 83-110% at a spiking of 1 μg L−1.  相似文献   

10.
Giordano A  Richter P  Ahumada I 《Talanta》2011,85(5):2425-2429
The rotating disk sorptive extraction (RDSE) technique was applied to the determination of pesticides in aqueous samples. Pesticides of different polarities were considered in this study: chlorpyrifos, diazinon, fenvalarate, cyhalothrin, cypermethrin, lindane and malathion. The sorptive/desorptive behavior of the pesticides was studied using a rotating disk containing a polydimethylsiloxane (PDMS) phase on one of its surfaces. The analyte polarity was a significant factor in the extraction time; shorter extraction times were required for the more apolar pesticides. The optimum variables for the extraction of all analytes were: extraction time of 3 h, sample volume of 25 mL, rotational velocity of the disk 1250 rpm, desorption time of 30 min using methanol. For pesticides with values of Log Kow > 4, the extraction time can be reduced to 30 min for a quantitative extraction. Under these conditions, recoveries between 76% and 101% were obtained for the target pesticides, and the repeatability of the methodology, expressed as relative standard deviation, was determined to be between 10% and 20%. Additionally, the limits of detection of the analytes were lower than 3.1 μg L−1. The extraction method developed using the RDSE was compared to a stir bar sorptive extraction (SBSE) under the same conditions. It can be observed that the extraction using the rotating disk offers higher recoveries because of its higher PDMS volume and its higher surface area to volume ratio that allows for improved mass transfer.  相似文献   

11.
A novel microextraction method making use of commercial polymer fiber as sorbent, coupled with high-performance liquid chromatography-fluorescence detection for the determination of polycyclic aromatic hydrocarbons (PAHs) in water has been developed. In this technique, the extraction device was simply a length (8 cm) of a strand of commercial polymer fiber, Kevlar (each strand consisted of 1000 filaments, each of diameter ca. 9.23 μm), that was allowed to tumble freely in the aqueous sample solution during extraction. The extracted analytes were desorbed ultrasonically before the extract was injected into HPLC system for analysis. Extraction parameters such as extraction time, desorption time, type of desorption solvent and sample volume were optimized. Each fiber could be used for up to 50 extractions and the method showed good precision, reproducibility and linear response within a concentration range 0.05–5.00 μg L−1 with correlation coefficients of up to 0.9998. Limits of detection between 0.4 and 4.4 ng L−1 for seven PAHs could be achieved. The relative standard deviations (n = 3) of this technique were between 2.9% and 12.1%.  相似文献   

12.
Sorbent particles consisting of nano and micro silica, and micron size octadecylsilica (ODS) were immobilized using sol-gel chemistry onto poly(dimethylsiloxane) (PDMS) microfluidic channels to serve as μ-chip solid phase extraction (SPE) devices. Extraction, preconcentration and purification of biological and chemical analytes were carried out using these. Micro and nano scale silica-immobilized μ-SPE were used for the extraction/purification of DNA from recombinant Escherichia coli crude lysate. The average DNA recovery was 77 ± 9% (X ± R.S.D.) for the micron size silica particles and 70 ± 5% (X ± R.S.D.) for the nano silica particles. The extracted DNA could be amplified by polymerase chain reaction (PCR) whereas the DNA from the crude lysate solution could not be. This was a testimony to the purification capability of the μ-SPE device. ODS immobilized μ-SPE were used to study the extraction efficiency (EE) and enhancement factor (EF) for three groups of organic compounds, aromatics, phenols and carboxylic acids. They showed poor recovery and low enrichment because the analytes sorbed into the PDMS and were not quantitatively extracted.  相似文献   

13.
In this paper, a new version of salting-out homogenous liquid–liquid extraction based on counter current mode combined with dispersive liquid–liquid microextraction has been developed for the extraction and preconcentration of some pesticides from aqueous samples and their determination by gas chromatography–flame ionization detection. In order to perform the method, aqueous solution of the analytes containing acetonitrile and 1,2-dibromoethane is transferred into a narrow bore tube which is filled partially with NaCl. During passing the solution through the tube, fine droplets of the organic phase are produced at the interface of solution and salt which go up through the tube and form a separated layer on the aqueous phase. The collected organic phase is removed and injected into de-ionized water for more enrichment of the analytes. Under the optimum extraction conditions, the method shows broad linear ranges for the target analytes. Enrichment factors and limits of detection for the selected pesticides are obtained in the ranges of 3480–3800 and 0.1–5 μg L−1, respectively. Relative standard deviations are in the range of 2–7% (n = 6, C = 50 or 100 μg L−1, each analyte). Finally, some aqueous samples were successfully analyzed using the developed method.  相似文献   

14.
In this study, a new sampling method called headspace mulberry paper bag micro solid phase extraction (HS-MPB-μ-SPE) combined to gas chromatography-mass spectrometry has been applied for the analysis of volatile aromas of liquid essential oils from Bulgarian rose and Provence lavender. The technique uses an adsorbent (Tenax TA) contained in a mulberry paper bag, minimal amount of organic solvent. Linearities for the six-points calibration curves were excellent. LOD values were in the rage from 0.38 ng mL−1 to 0.77 ng mL−1. Overall, precision and recovery were generally good. Phenethyl alcohol and citronellol were the main components in the essential oil from Bulgarian rose. Linalyl acetate and linalool were the most abundant components in the essential oils from true lavender or lavandin. Additionally, the relative extraction efficiencies of proposed method have been compared with HS-SPME. The overall extraction efficiency was evaluated by the relative concentration factors (CF) of the several characteristic components. CF values by HS-MPB-μ-SPE were lower than those by headspace solid phase microextraction (HS-SPME). The HS-MPB-μ-SPE method is very simple to use, inexpensive, rapid, requires small sample amounts and solvent consumption. In addition, this method allowed combining of extraction, enrichment, and clean-up in a single step. HS-MPB-μ-SPE and GC/MS is a promising technique for the characterization of volatile aroma compounds from liquid essential oils.  相似文献   

15.
In this research we report the implementation of micro-solid-phase extraction (μ-SPE) in the needle of a syringe for integrating sampling, analyte enrichment and sample introduction into a single device. Both single- and multi-walled carbon nanotubes (CNTs) were explored as high performance sorbents for μ-SPE in packed and self assembled formats. The need for such a sorbent was critical because the needle probe could hold only a small amount of material (around 300 μg). Conventional C-18 and self-assembled CNTs were found to be ineffective with enrichment factors less than one. However, packed beds of CNTs were found to be excellent sorbent phases, where high extraction efficiencies (as high as 27%) as well as enrichment factors (close to 7) could be achieved. The overall method showed excellent linearity, reproducibility, and low method detection limit (0.1–3 ng/mL for MWNTs). The sorption on CNTs followed Freundlich isotherms, and the functionalized CNTs were more effective for enriching the polar compounds.  相似文献   

16.
The automated method developed for the determination of carotenoids uses 200 μL of serum, which was mixed with 400 μL of tetrahydrofuran, vortexed for 1 min, settled for 10 min, centrifuged for 6 min and the supernatant injected into an automatic solid-phase extraction (SPE) system for cleanup-preconcentration. A 10% water-acetonitrile mobile phase at 1.5 mL min−1 eluted the retained compounds and transferred them on-line to a reversed-phase analytical column for individual separation of the target analytes. Visible detection was performed at 450 and 460 nm. The detection limits for the target analytes were between 3 and 30 ng mL−1; the precision (expressed as relative standard deviation) ranged between 2.83 and 5.06% for repeatability and between 3.80 and 7.40% for within laboratory reproducibility. The total analysis time was 18 min. The proposed method is reliable, robust, and has an excellent potential for high-throughput use in both clinical and research laboratories.  相似文献   

17.
Solid-phase extraction (SPE) procedures for cleanup and preconcentration followed by HPLC-UV method were investigated for the simultaneous determination of seven low-dosed pesticides in saline concentrates for hemodialysis. The target compounds were ametryn, desmetryn, prometryn, terbutryn, molinate, triallate and butylate. Polyethylene (three different types), teflon, polyurethane and polystyrene, in powder form, were investigated as adsorbents for solid-phase extraction of the analytes from the saline samples. Quantification was performed at 222 nm and the analytes were separated on a LiChrosorb RP-18 (5 μm, 125 mm × 4 mm i.d.) column using gradient elution with water/acetonitrile as mobile phase. The duration each chromatographic run was 18 min including column reconditioning. The efficiency of the different SPE substrates for retaining the analytes from the highly concentrated saline (HCS) samples was discussed. The best performance was achieved with polystyrene as SPE material considering preconcentration factor, precolumn clogging, reusing capability and similarity between the mobile phases for SPE and HPLC procedures. Analyte concentrations as low as 1 μg L−1 could be determined in spiked HCS samples after preconcentration on polystyrene SPE precolumns. Recoveries between 98.7 and 102.2% were obtained from commercial spiked samples. Detection limits ranging from 4.8 (for prometryn) to 46 μg L−1 (for butylate) were calculated (without preconcentration). The within-day relative standard deviations (n = 9) ranged from 2.3 to 4.8%.  相似文献   

18.
A liquid chromatography-tandem mass spectrometry method for the determination and confirmation of nine quinolones was optimised and validated according to Commission Decision 2002/657/EC. Analytes were extracted from veal muscle with water and extracts purified with 96-well plates Oasis HLB cartridges. Separation was carried out in a silica-based C18 column (50 mm × 2.1 mm) with mobile phases consisting of water/acetonitrile mixtures containing acetic acid. Linear calibration curves in the ranges 4-400 and 50-800 ng g−1, with correlation coefficients at least 0.995, were obtained for all the analytes. At concentration levels above 10 ng g−1, quantification errors were lower than 10% and repeatability and within-laboratory reproducibility standard deviations below 6% and 10%, respectively. Decision limits and detection capabilities are reported.  相似文献   

19.
In present study, a convenient, sensitive and environmentally friendly method for the determination of five benzoylurea insecticides (BUs) in water and juice samples was developed. To extract trace benzoylurea insecticides effectively, poly(methacrylic acid-co-ethylene dimethacrylate) monolith was prepared and used as the sorbent of multiple monolithic fiber solid-phase microextraction (MMF-SPME). The influences of preparation conditions of monolith and extraction parameters of MMF-SPME on BUs were studied thoroughly. Under the optimized conditions, the combination of MMF-SPME with high performance liquid chromatography-diode array detection (MMF-SPME-HPLC-DAD) showed expected analytical performance for target analytes. The limits of detection (S/N = 3) of the developed method were 0.026–0.075 μg L−1 in water and 0.053–0.29 μg L−1 in juice samples. Good linearity was obtained for analytes with the correlation coefficients (R2) above 0.99. Satisfactory repeatability and reproducibility was achieved, with relative standard deviations (RSD) of both less than 10%. Finally, the established MMF-SPME-HPLC-DAD method was successfully applied for the determination of BUs residues in juice and environmental water samples. Recoveries obtained for the determination of BUs in spiking samples ranged from 65.1% to 118%, with RSD below 10% in all cases.  相似文献   

20.
A method based on solid-phase microextraction and gas chromatography flame photometric detector for the determination of organophosphorus pesticides (OPPs) in food samples was described. Three kinds of vinyl crown ether polar fibers were prepared with sol-gel process and used for the analytes. The new coatings showed higher extraction efficiency and sensitivity for organophosphorus pesticides compared with commercial fibers—85 μm PA and 65 μm PDMS-DVB. Specifically, the benzo-15-crown-5 coating was the most effective for the target analytes. Several factors affecting the performance of SPME such as extraction temperature and time, salt addition, and dilution ratios of samples were optimized. The apparent recoveries of spiked food samples (apple juice, apple and tomato) were determined to be over 55.3% and the limits of detection (LODs) were in the range of 0.003-0.09 ng/g for the OPP studied. The method was applied to determine the concentrations of OPP in real food samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号