首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
This paper reports a facile and general method for preparing an imprinted polymer thin shell with Mn-doped ZnS quantum dots (QDs) at the surface of silica nanoparticles by stepwise precipitation polymerization to form the highly-controllable core–shell nanoparticles (MIPs@SiO2–ZnS:Mn QDs) and sensitively recognize the target 2,4-dichlorophenol (2,4-DCP). Acrylamide (AM) and ethyl glycol dimethacrylate (EGDMA) were used as the functional monomer and the cross-linker, respectively. The MIPs@SiO2–ZnS:Mn QDs had a controllable shell thickness and a high density of effective recognition sites, and the thickness of uniform core–shell 2,4-DCP-imprinted nanoparticles was controlled by the total amounts of monomers. The MIPs@SiO2–ZnS:Mn QDs with a shell thickness of 45 nm exhibited the largest quenching efficiency to 2,4-DCP by using the spectrofluorometer. After the experimental conditions were optimized, a linear relationship was obtained covering the linear range of 1.0–84 μmol L−1 with a correlation coefficient of 0.9981 and the detection limit (3σ/k) was 0.15 μmol L−1. The feasibility of the developed method was successfully evaluated through the determination of 2,4-DCP in real samples. This study provides a general strategy to fabricate highly-controllable core–shell imprinted polymer-contained QDs with highly selective recognition ability.  相似文献   

2.
Wang Y  Tang J  Luo X  Hu X  Yang C  Xu Q 《Talanta》2011,85(5):2522-2527
In this work, a kojic acid electrochemical sensor, based on a non-covalent molecularly imprinted polymer (MIP) modified electrode, had been fabricated in the lab-on-valve system. The sensitive layer was synthesized by cyclic voltammetry using o-phenylenediamine as the functional monomer and kojic acid as the template. The template molecules were then removed from the modified electrode surface by washing with NaOH solution. Differential pulse voltammetry method using ferricyanide as probe was applied as the analytical technique, after extraction of kojic acid on the electrode. Chemical and flow parameters associated with the extraction process were investigated. The response recorded with the imprinted sensor exhibited a response in a range of 0.01-0.2 μmol L−1 with a detection limit of 3 nmol L−1. The interference studies showed that the MIP modified electrode had excellent selectivity. Furthermore, the proposed MIP electrode exhibited good sensitivity and low sample/reagent consumption, and the sensor could be applied to the determination kojic acid in cosmetics samples.  相似文献   

3.
This work reports the preparation of a molecularly imprinted polymer (MIP) for selective catalytic detection of serotonin (5-hydroxytryptamine, 5-HT). The process is based on the synthesis of polymers with hemin introduced as the catalytic center to mimic the active site of peroxidase. The copolymer MIP, containing artificial recognition sites for 5-HT, has been prepared by bulk polymerization using methacrylic acid (MAA) and hemin as the functional monomers, and ethylene glycol dimethacrylate (EGDMA) as the cross-linker. For the determination of 5-HT, a flow injection analysis system coupled to an amperometric detector was optimized using multivariate analysis. The effects of different parameters, such as pH, buffer flow rate, buffer nature, peroxide concentration and sample volume were evaluated. After optimizing the experimental conditions, a linear response range from 1.0 up to 1000.0 μmol L−1 was obtained with a sensitivity of 0.4 nA/μmol L−1. The detection limit was found to be 0.30 μmol L−1, while the precision values (n = 6) evaluated by relative standard deviation (R.S.D.) were, respectively, 1.3 and 1.7% for solutions of 50 and 750 μmol L−1 of 5-HT. No interference was observed by structurally similar compounds (including epinephrine, dopamine and norepinephrine), thus validating the good performance of the imprinted polymer. The method was applied for the determination of 5-HT in spiked blood serum samples.  相似文献   

4.
A novel voltammetric sensor for O,O-dimethyl-(2,4-dichlorophenoxyacetoxyl)(3′-nitrophenyl)methinephosphonate (Phi-NO2) based on molecularly imprinted polymer (MIP) film electrode is constructed by using sol-gel technology. The sensor responds linearly to Phi-NO2 over the concentration range of 2.0 × 10−5 to 1.0 × 10−8 mol L−1 and the detection limit is 1.0 × 10−9 mol L−1 (S/N = 3). This sensor provides an efficient way for eliminating interferences from coexisting substances in the solution. The high sensitivity, selectivity and stability of the sensor demonstrates its practical application for a simple and rapid determination of Phi-NO2 in cabbage samples.  相似文献   

5.
A facile and efficient molecularly imprinted polymer (MIP) recognition element of electrochemical sensor was fabricated by directly electro-polymerizing monomer o-phenylenediamine (oPD) in the presence of template quinoxaline-2-carboxylic acid (QCA), based on one-step controllable electrochemical modification of poly(pyrrole)-graphene oxide-binuclear phthalocyanine cobalt (II) sulphonate (PPY-GO-BiCoPc) functional composite on glassy carbon electrode (GCE). The MIP film coated on PPY-GO-BiCoPc functional composite decorated GCE (MIP/PPY-GO-BiCoPc/GCE) was presented for the first time. The synergistic effect and electro-catalytic activity toward QCA redox of PPY-GO-BiCoPc functional composite were discussed using various contrast tests. Also, the effect of experimental variables on the current response such as, electro-polymerization cycles, template/monomer ratio, elution condition for template removal, pH of the supporting electrolyte and accumulation time, were investigated in detail. Under the optimized conditions, the proposed MIP sensor possessed a fast rebinding dynamics and an excellent recognition capacity to QCA, while the anodic current response of square wave voltammetry (SWV) was well-proportional to the concentration of QCA in the range of 1.0 × 10−8–1.0 × 10−4 and 1.0 × 10−4–5.0 × 10−4 mol L−1 with a low detection limit of 2.1 nmol L−1. The established sensor was applied successfully to determine QCA in commercial pork and chicken muscle samples with acceptable recoveries (91.6–98.2%) and satisfactory precision (1.9–3.5% of SD), demonstrating a promising feature for applying the MIP sensor to the measurement of QCA in real samples.  相似文献   

6.
A new molecularly imprinted electrochemiluminescence (ECL) sensor was proposed for highly sensitive and selective determination of ultratrace Be2+ determination. The complex of Be2+ with 4-(2-pyridylazo)-resorcinol (PAR) was chosen as the template molecule for the molecularly imprinted polymer (MIP). In this assay, the complex molecule could be eluted from the MIP, and the cavities formed could then selectively recognize the complex molecules. The cavities formed could also work as the tunnel for the transfer of probe molecules to produce sound responsive signal. The determination was based on the intensity of the signal, which was proportional to the concentrations of the complex molecule in the sample solution, and the Be2+ concentration could then be determined indirectly. The results showed that in the range of 7 × 10−11 mol L−1 to 8.0 × 10−9 mol L−1, the ECL intensity had a linear relationship with the Be2+ concentrations, with the limit of detection of 2.35 × 10−11 mol L−1. This method was successfully used to detect Be2+ in real water samples.  相似文献   

7.
By using a molecularly imprinted polymer (MIP) as a recognition element, the design and construction of a high selective voltammetric sensor for para-nitrophenol was formed. Para-nitrophenol selective MIP and a non-imprinted polymer (NIP) were synthesized, and then used for carbon paste (CP) electrode preparation. The MIP-CP electrode showed greater recognition ability in comparison to the NIP-CP. It was shown that electrode washing after para-nitrophenol extraction led to enhanced selectivity, without noticeably decreasing the sensitivity. Some parameters affecting sensor response were optimized and a calibration curve was plotted. A dynamic linear range of 8 × 10−9 to 5 × 10−6 mol L−1 was obtained. The detection limit of the sensor was calculated as 3 × 10−9 mol L−1. Thus, this sensor was used successfully for the para-nitrophenol determination in different water samples.  相似文献   

8.
A novel flow injection chemiluminescence (FI-CL) sensor for determination of sulfadiazine (SDZ) using core–shell magnetic molecularly imprinted polymers (MMIPs) as recognition element is developed. Briefly, a hydrophilic MMIPs layer was produced at the surface of Fe3O4@SiO2 magnetic nanoparticles (MNPs) via combination of molecular imprinting and reversible stimuli responsive hydrogel. And it provided the MMIPs with excellent adsorption capacity and rapid adsorption rate due to the imprinted sites mostly situated on the surface of MMIPs. Then the prepared SDZ-MMIPs were packed into flow cell to establish a novel FI-CL sensor. The sensor provided a wide linear range for SDZ of 4.0 × 10−7 to 1.0 × 10−4 mol L−1 with a detection limit of 1.54 × 10−7 mol L−1. And the relative standard deviation (RSD) for the determination of 1.0 × 10−6 mol L−1 SDZ was 2.56% (n = 11). The proposed method was applied to determine SDZ in urine samples and satisfactory results were obtained.  相似文献   

9.
Hu YF  Zhang ZH  Zhang HB  Luo LJ  Yao SZ 《Talanta》2011,84(2):305-313
A sensitive and selective electrochemical sensor based on a polyaniline modified carbon electrode for the determination of l-phenylalanine has been proposed by utilizing β-cyclodextrin (β-CD) incorporated multi-walled carbon nanotube (MWNT) and imprinted sol-gel film. The electrochemical behavior of the sensor towards l-phenylalanine was investigated by cyclic voltammetry (CV), differential pulse voltammetry (DPV), and amperometric i-t curve. The surface morphologies of layer-by-layer assembly electrodes were displayed by scanning electron microscope (SEM). The response mechanism of the imprinted sensor for l-phenylalanine was based on the inclusion interaction of β-CD and molecular recognition capacity of the imprinted film for l-phenylalanine. A linear calibration plot was obtained covering the concentration range from 5.0 × 10−7 to 1.0 × 10−4 mol L−1 with a detection limit of 1.0 × 10−9 mol L−1. With excellent sensitivity, selectivity, stability, reproducibility and recovery, the electrochemical imprinted sensor was used to detect l-phenylalanine in blood plasma samples successfully.  相似文献   

10.
A sensitive molecularly imprinted electrochemical sensor was created for selective detection of a tricyclic antidepressant imipramine by combination of Au nanoparticles (Au-NPs) with a thin molecularly imprinted film. The sensor was fabricated onto the indium tin oxide (ITO) electrode via stepwise modification of Au-NPs by self-assembly and a thin film of molecularly imprinted polymers (MIPs) via sol-gel technology. It was observed that the molecularly imprinted film displayed excellent selectivity towards the target molecule imipramine. Meanwhile, the introduced Au-NPs exhibited noticeable catalytic activities towards imipramine oxidation, which remarkably enhanced the sensitivity of the imprinted film. Due to such combination, the as-prepared sensor responded quickly to imipramine, within only 1 min of incubation. The differential voltammetric anodic peak current was linear to the logarithm of imipramine concentration in the range from 5.0 × 10−6 to 1.0 × 10−3 mol L−1, and the detection limits obtained was 1.0 × 10−9 mol L−1. This method proposed was successfully applied to the determination of imipramine in drug tablets, and proven to be reliable compared with conventional UV method. These results reveal that such a sensor fulfills the selectivity, sensitivity, speed and simplicity requirements for imipramine detection, and provides possibilities of clinical application in physiological fluids.  相似文献   

11.
In this paper, we presented a novel, rapid and highly sensitive sensor for glutathione (GSH), cysteine (Cys) and histidine (His) based on the recovered fluorescence of the carbon quantum dots (CQDs)–Hg(II) system. The CQDs were synthesized by microwave-assisted approach in one pot according to our previous report. The fluorescence of CQDs could be quenched in the presence of Hg(II) due to the coordination occurring between Hg(II) and functional groups on the surface of CQDs. Subsequently, the fluorescence of the CQDs–Hg(II) system was recovered gradually with the addition of GSH, Cys or His due to their stronger affinity with Hg(II). A good linear relationship was obtained from 0.10 to 20 μmol L−1 for GSH, from 0.20 to 45 μmol L−1 for Cys and from 0.50 to 60 μmol L−1 for His, respectively. This method has been successfully applied to the trace detection of GSH, Cys or His in human serum samples with satisfactory results. The proposed method was simple in design and fast in operation, which demonstrated great potential in bio-sensing fields.  相似文献   

12.
A novel dual-function material was synthesized by anchoring a molecularly imprinted polymer (MIP) layer on CdTe/ZnS quantum dots (QDs) using a sol–gel with surface imprinting. The material exhibited highly selective and sensitive determination of ractopamine (RAC) through spectrofluorometry and solid-phase extraction (SPE) coupled with high performance liquid chromatography (HPLC). A series of adsorption experiments revealed that the material showed high selectivity, good adsorption capacity and a fast mass transfer rate. Fluorescence from the MIP-coated QDs was more strongly quenched by RAC than that of the non-imprinted polymer, which indicated that the MIP-coated QDs acted as a fluorescence sensing material could recognize RAC. In addition, the MIP-coated QDs as a sorbent was also shown to be promising for SPE coupled with HPLC for the determination of trace RAC in feeding stuffs and pork samples. Under optimal conditions, the spectrofluorometry and SPE-HPLC methods using the MIP-coated QDs had linear ranges of 5.00 × 10−10–3.55 × 10−7 and 1.50 × 10−10–8.90 × 10−8 mol L−1, respectively, with limits of detection of 1.47 × 10−10 and 8.30 × 10−11 mol L−1, the relative standard deviations for six repeat experiments of RAC (2.90 × 10−9 mol L−1) were below 2.83% and 7.11%.  相似文献   

13.
An improved multiple co-polymerization technique was developed to prepare a novel molecularly imprinted polymer (MIP)-coated solid-phase microextraction (SPME) fiber with propranolol as template. Investigation was performed for the characteristics and application of the fibers. The MIP coating was highly crosslinked and porous with the average thickness of only 25.0 μm. Consequently, the adsorption and desorption of β-blockers within the MIP coating could be achieved quickly. The specific selectivity was discovered with the MIP-coated fibers to propranolol and its structural analogues such as atenolol, pindolol, and alprenolol. In contrast, only non-specific adsorption could be shown with the non-imprinted polymer (NIP)-coated fibers, and the extraction efficiencies of propranolol and pindolol with the MIP-coated fibers were higher markedly than that with the commercial SPME fibers. A MIP-coated SPME coupled with high-performance liquid chromatography (HPLC) method for propranolol and pindolol determination was developed under the optimized extraction conditions. Linear ranges for propranolol and pindolol were 20–1000 μg L−1 and detection limits were 3.8 and 6.9 μg L−1, respectively. Propranolol and pindolol in the spiked human urine and plasma samples, extracted with organic solvent firstly, could be simultaneous monitored with satisfactory recoveries through this method.  相似文献   

14.
A novel chemiluminescence (CL) microfluidic system incorporating a molecularly imprinted polymer (MIP) preconcentration step was used for the determination of chloramphenicol in honey samples. The MIP was prepared by using chloramphenicol as the template, diethylaminoethyl methacrylate (DAM) as the function monomer, ethylene glycol dimethacrylate (EGDMA) as the cross-linking monomer, 2, 2′-dimethoxy-2-phenylacetophenone (DMPA) as the free radical initiator and toluene and dodecanol as the solvent. The MIP was pre-loaded into a 10 mm long, 2 mm wide and 150 μm deep channel in a planar glass microfluidic device. When the sample containing chloramphenicol was introduced into the microfluidic device it was first preconcentrated on the MIP then detected by an enhancement effect on the chemiluminescence reaction of tris(2, 2′-bipyridyl) ruthenium(II) with cerium(IV) sulphate in sulphuric acid. A micro-syringe pump was used to pump the reagents. The CL intensity was linear in relationship to the chloramphenicol concentrations from 1.55 × 10−4 to 3.09 × 10−3 μmol L−1 (r2 = 0.9915) and the detection limit (3σ) and the quantitation limit (10σ) were found to be 7.46 × 10−6 and 2.48 × 10−5 μmol L−1, respectively. This method offered a high selectivity and sensitivity for quantitative analysis of chloramphenicol in the honey samples.  相似文献   

15.
This work describes the development of an electrochemical sensor based on a new molecularly imprinted polymer for detection of metoprolol (MTP) at ultra-trace level. The polypyrrole (PPy) was electrochemically synthesized on the tip of a pencil graphite electrode (PGE) which modified whit functionalized multi-walled carbon nanotubes (MWCNTs). The fabrication process of the sensor was characterized by cyclic voltammetry (CV) and the measurement process was carried out by differential pulse voltammetry (DPV). A computational approach was used to screening functional monomers and polymerization solvent for rational design of molecularly imprinted polymer (MIP). Based on computational results, pyrrole and water were selected as functional monomer and polymerization solvent, respectively. Several significant parameters controlling the performance of the MIP sensor were examined and optimized using multivariate optimization methods such as Plackett–Burman design (PBD) and central composite design (CCD). Under the selected optimal conditions, MIP sensor was showed a linear range from 0.06 to 490 μmol L−1 MTP, a limit of detection of 2.88 nmol L−1, a highly reproducible response (RSD 3.9%) and a good selectivity in the presence of structurally related molecules. Furthermore, the applicability of the method was successfully tested with determination of MTP in real samples (tablet, and serum).  相似文献   

16.
Liu C  Mo YY  Chen ZG  Li X  Li OL  Zhou X 《Analytica chimica acta》2008,621(2):171-177
A new dual detection system for microchip is reported. Both fluorescence detector (FD) and contactless conductivity detector (CCD) were combined together and integrated on a microfluidic chip. They shared a common detection position and responded simultaneously. A blue light-emitting diode was used as excitation source and a small planar photodiode was used to collect the emitted fluorescence in fluorescence detection, which made the device more compact and portable. The coupling of the fluorescence and contactless conductivity modes at the same position of a single separation channel enhanced the detection characterization of sample and offered simultaneous detection information of both fluorescent and charged specimen. The detection conditions of the system were optimized. K+, Na+, fluorescein sodium, fluorescein isothiocyanate (FITC) and FITC-labeled amino acids were used to evaluate the performance of the dual detection system. The limits of detection (LOD) of FD for fluorescein Na+, FITC, FITC-labeled arginine (Arg), glycine (Gly) and phenylalanine (Phe) were 0.02 μmol L−1, 0.05 μmol L−1, 0.16 μmol L−1, 0.15 μmol L−1, 0.12 μmol L−1 respectively, and the limits of detection (LOD) of CCD achieved 0.58 μmol L−1 and 0.39 μmol L−1 for K+ and Na+ respectively.  相似文献   

17.
Hu Y  Li Y  Liu R  Tan W  Li G 《Talanta》2011,84(2):462-470
Novel magnetic molecularly imprinted polymer (MIP) beads using ractopamine as template for use in extraction was developed by microwave heating initiated suspension polymerization. Microwave heating, as an alternative heating source, significantly accelerate the polymerization process. By incorporating magnetic iron oxide, superparamagnetic composite MIP beads with average diameter of 80 μm were obtained. The imprinted beads were then characterized by scanning electron microscopy, Fourier transform infrared spectroscopy, thermogravimetric analysis and vibrating sample magnetometer. Highly cross-linked porous surface and good magnetic property were observed. The adsorption isotherm modeling was performed by fitting the data to Freundlich isotherm model. The binding sites measured were 3.24 μmol g−1 and 1.17 μmol g−1 for the magnetic MIP beads and the corresponding non-imprinted magnetic beads, respectively. Cross-selectivity experiments showed the recognition ability of the magnetic MIP beads to analytes is relative to degree of molecular analogy to the template. Finally, this magnetic MIP bead was successfully used for enrichment of ractopamine, isoxsuprine and fenoterol from ultrasonically extracted solution of pork and pig liver followed by high performance chromatography with fluorescence detection. The proposed method presented good linearity and the detection limits was 0.52-1.04 ng mL−1.The recoveries were from 82.0% to 90.0% and from 80.4% to 86.8% for the spiked pork and pig liver, respectively, with the RSDs of 5.8-10.0%. Combination of the specific adsorption property of the MIP material and the magnetic separation provided a powerful analytical tool of simplicity, flexibility, and selectivity.  相似文献   

18.
Surface-imprinted core–shell Au nanoparticles (AuNPs) were explored for the highly selective detection of bisphenol A (BPA) by surface-enhanced Raman scattering (SERS). A triethoxysilane-template complex (BPA-Si) was synthesized and then utilized to fabricate a molecularly imprinted polymer (MIP) layer on the AuNPs via a sol–gel process. The imprinted BPA molecules were removed by a simple thermal treatment to generated the imprint-removed material, MIP-ir-AuNPs, with the desired recognition sites that could selectively rebind the BPA molecules. The morphological and polymeric characteristics of MIP-ir-AuNPs were investigated by transmission electron microscopy and Fourier-transform infrared spectroscopy. The results demonstrated that the MIP-ir-AuNPs were fabricated with a 2 nm MIP shell layer within which abundant amine groups were generated. The rebinding kinetics study showed that the MIP-ir-AuNPs could reach the equilibrium adsorption for BPA within 10 min owning to the advantage of ultrathin core–shell nanostructure. Moreover, a linear relationship between SERS intensity and the concentration of BPA on the MIP-ir-AuNPs was observed in the range of 0.5–22.8 mg L−1, with a detection limit of 0.12 mg L−1 (blank ± 3 × s.d.). When applied to SERS detection, the developed surface-imprinted core–shell MIP-ir-AuNPs could recognize BPA and prevent interference from the structural analogues such as hexafluorobisphenol A (BPAF) and diethylstilbestrol (DES). These results revealed that the proposed method displayed significant potential utility in rapid and selective detection of BPA in real samples.  相似文献   

19.
An original electrochemical sensor based on molecularly imprinted conducting polymer (MICP) is developed, which enables the recognition of a small pesticide target molecule, atrazine. The conjugated MICP, poly(3,4-ethylenedioxythiophene-co-thiophene-acetic acid), has been electrochemically synthesized onto a platinum electrode following two steps: (i) polymerization of comonomers in the presence of atrazine, already associated to the acetic acid substituent through hydrogen bonding, and (ii) removal of atrazine from the resulting polymer, which leaves the acetic acid substituents open for association with atrazine. The obtained sensing MICP is highly specific towards newly added atrazine and the recognition can be quantitatively analyzed by the variation of the cyclic voltammogram of MICP. The developed sensor shows remarkable properties: selectivity towards triazinic family, large range of detection (10−9 mol L−1 to 1.5 × 10−2 mol L−1 in atrazine) and low detection threshold (10−7 mol L−1).  相似文献   

20.
Bisphenol A (BPA), which could disrupt endocrine system and cause cancer, has been considered as an endocrine disruptor. Therefore, it is very important and necessary to develop a sensitive and selective method for detection of BPA. Herein, nitrogen-doped graphene sheets (N-GS) and chitosan (CS) were used to prepare electrochemical BPA sensor. Compared with graphene, N-GS has favorable electron transfer ability and electrocatalytic property, which could enhance the response signal towards BPA. CS also exhibits excellent film forming ability and improves the electrochemical behavior of N-GS modified electrode. The sensor exhibits a sensitive response to BPA in the range of 1.0 × 10−8–1.3 × 10−6 mol L−1 with a low detection limit of 5.0 × 10−9 mol L−1 under the optimal conditions. Finally, this proposed sensor was successfully employed to determine BPA in water samples with satisfactory results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号