首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
In this work, a new electrochemical aptasensor using hybridization chain reaction (HCR) for signal amplification was developed for highly sensitive detection of thrombin. The sandwich system of aptamer/thrombin/aptamer–primer complex was fabricated as the sensing platform. As the initiator strands, aptamer–primer complex could propagate a chain reaction of hybridization events between the two hairpin probes, and whether long nicked DNA polymers could be formed on the modified electrode. Then the biotin-labeled dsDNA polymers could introduce numerous avidin-labeled horseradish peroxidase (HRP), resulting in significantly amplified electrochemical signal through the electrocatalysis of HRP. On the basis of the enzymatic oxidization of Fe2+ by H2O2 to yield Fe3+, the imaging of thrombin was detected by the reduction current of Fe3+ with the scanning electrochemical microscopic tip. The electrochemical signals had a good linear with logarithm of thrombin concentration in the range from 1.0 fM to 100 fM, reaching a detection limit of thrombin as low as 0.04 fM. In addition, the proposed strategy exhibited excellent specificity and was successfully applied in real sample assay which demonstrated the potential application in clinical diagnostics.  相似文献   

2.
A mimic-hybridization chain reaction (mimic-HCR) amplified strategy was proposed for sensitive electrochemically detection of DNA methylation and methyltransferase (MTase) activity In the presence of methylated DNA, DNA-gold nanoparticles (DNA-AuNPs) were captured on the electrode by sandwich-type assembly. It then triggered mimic-HCR of two hairpin probes to produce many long double-helix chains for numerous hexaammineruthenium (III) chloride ([Ru(NH3)6]3+, RuHex) inserting. As a result, the signal for electrochemically detection of DNA MTase activity could be amplified. If DNA was non-methylated, however, the sandwich-type assembly would not form because the short double-stranded DNAs (dsDNA) on the Au electrode could be cleaved and digested by restriction endonuclease HpaII (HapII) and exonuclease III (Exo III), resulting in the signal decrement. Based on this, an electrochemical approach for detection of M.SssI MTase activity with high sensitivity was developed. The linear range for M.SssI MTase activity was from 0.05 U mL−1 to 10 U mL−1, with a detection limit down to 0.03 U mL−1. Moreover, this detecting strategy held great promise as an easy-to-use and highly sensitive method for other MTase activity and inhibition detection by exchanging the corresponding DNA sequence.  相似文献   

3.
In this work, a novel electrochemical protocol with signal amplification for determination of DNA methylation and methyltransferase activity using DNA-based hybridization chain reaction (HCR) was proposed. After the gold electrode was modified with dsDNA, it was treated with M.SssI MTase, HpaII endonuclease, respectively. And then the HCR was initiated by the target DNA and two hairpin helper DNAs, which lead to the formation of extended dsDNA polymers on the electrode surface. The signal was amplified by the labeled biotin on the hairpin probes. As a result, the streptavidin-alkaline phosphatase (S-ALP) conjugated on the electrode surface through the specific interaction between biotin and S-ALP. ALP could convert 1-naphthyl phosphate into 1-naphthol and the latter could be electrochemically oxidized, which was used to monitor the methylation event and MTase activity. The HCR assay presents good electrochemical responses for the determination of M.SssI MTase at a concentration as low as 0.0067 unit mL−1. Moreover, the effects of anti-cancer drug and environmental phenolic hormone on M.SssI MTase activity were also investigated. The results indicated that 5-fluorouracil and daunorubicin hydrochloride could inhibit the activity, and the opposite results were obtained with bisphenol A and nonylphenol. Therefore, this method can not only provide a platform to screen the inhibitors of DNA MTase and develop new anticancer drugs, but also offer a novel technique to investigate the possible carcinogenesis mechanism.  相似文献   

4.
The combination of high selectivity of aptamer with the peroxidase-mimicking property of DNAzyme has presented considerable opportunities for designing colorimetric aptasensor for detection of ochratoxin A (OTA). The activities of both aptamer (as biorecognition element) and DNAzyme (as signal amplification element) are blocked via base pairing in the hairpin structure. Hybridization chain reaction (HCR) between two hairpin DNAs was employed to further improve the sensitivity of this method. The presence of OTA triggers the opening of the hairpin structure and the beginning of HCR, which results in the release of many DNAzyme, and generates enhanced colorimetric signals, which is correlated to the amounts of OTA with linear range between 0.01 to 0.32 nM, and the limit of detection is 0.01 nM under optimal conditions. OTA in yellow rice wine and wheat flour samples was also detected using this method. We demonstrate that a new colorimetric method for the detection of OTA has been established, which is simple, easy to conduct, label-free, sensitive, high throughput, and cost-saving.  相似文献   

5.
Biosensors based on surface plasmon resonance (SPR) have become a central tool for the investigation and quantification of biomolecules and their interactions. Nucleic acids (NAs) play a vital role in numerous biological processes and therefore have been one of the major groups of biomolecules targeted by the SPR biosensors. This paper discusses the advances of NA SPR biosensor technology and reviews its applications both in the research of molecular interactions involving NAs (NA–NA, NA–protein, NA–small molecule), as well as for the field of bioanalytics in the areas of food safety, medical diagnosis and environmental monitoring.  相似文献   

6.
7.
A label-free and non-enzymatic amplification fluorescent method for detection of DNA has been developed by using hybridization chain reaction (HCR) and dsDNA-templated copper nanoparticles (CuNPs). First, the biotinylated capture DNA probes were immobilized on the streptavidin-modified beads through the interaction of biotin and streptavidin. Then, target DNA hybridized with the capture DNA probes, which formed a hybridized DNA with sticky end. The sticky end triggered the HCR process and formation of dsDNA polymers while two hairpin probes coexisted. Subsequently, the dsDNA polymers were employed as template for synthesis of CuNPs with excellent fluorescent properties, which provided a label-free, non-enzymatic signal response. Meanwhile, the fluorescence sensing depended on the target DNA triggered HCR, which render this method a high selectivity against single-base mismatch sequences. The concept and methodology developed in this work show great promise in the quantitative detection of DNA in biological and medical applications.  相似文献   

8.
Aberrant DNA methylation originated from changes in DNA methyltransferase activity can lead to many genetic diseases and tumor types, and the monitoring of methyltransferase activity is thus of great importance in disease diagnosis and drug screening. In this work, by combing hybridization chain reaction (HCR) and metal ion-dependent DNAzyme recycling, we have developed a convenient enzyme-free signal amplification strategy for highly sensitive detection of DNA adenine methyltransferase (Dam MTase) activity and its inhibitors. The Dam MTase-induced methylation and subsequent cleavage of the methylated hairpin DNA probes by DpnI endonuclease lead to the release of ssDNA triggers for HCR formation of many Mg2+-dependent DNAzymes, in which the fluorescently quenched substrate sequences are catalytically and cyclically cleaved by Mg2+ to generate remarkably amplified fluorescent signals for highly sensitive detection of Dam MTase at 7.23 × 10−4 U/mL. In addition, the inhibition of different drugs to Dam MTase activity can also be evaluated with the developed method. With the advantages of simplicity and significant signal amplification over other common methods, the demonstrated biosensing approach thus offers great potential for highly sensitive detection of various methyltransferases and provides a convenient platform for drug screening for therapeutic applications.  相似文献   

9.
端粒酶是真核细胞维持端粒长度的关键逆转录酶,其生物活性的高低可以为多种癌症的临床诊断和预后治疗提供有价值的信息.本研究以人宫颈癌细胞(HeLa细胞)裂解液中的端粒酶为研究对象,通过借助杂交链式反应辅助多重信号放大策略,提出了一种新颖、灵敏的检测端粒酶电化学方法.首先将端粒酶的延伸引物自组装在金电极表面,当端粒酶存在时,端粒酶能够催化引物的延伸,产生与发卡环探针H1部分互补的序列,进而引发杂交链式反应,形成由两个发卡环探针(H1和H2)交替杂交而形成的DNA长链.由于H1和H2末端均修饰有生物素,加入链霉亲和素修饰辣根过氧化物酶后,辣根过氧化物酶被被连接到电极表面,催化邻苯二胺氧化生成2,3-二氨基吩嗪,产生显著的电化学信号.实验结果表明,本研究建立的端粒酶电化学检测方法高效、可行,线性范围宽,灵敏度高,可以检测每毫升10个HeLa细胞裂解液中的端粒酶.本方法具有较好的选择性,能有效区分端粒酶和对照蛋白.  相似文献   

10.
Zhang N  Zhang X  Zhao Y 《Talanta》2004,62(5):1041-1045
The behavior of the ciprofloxacin (CPFX) complex with copper, Cu(II)L2, at a mercury electrode has been investigated in borax–boric acid buffer. The adsorption phenomena were observed by linear sweep voltammetry. The mechanism of the electrode reaction was found to be reduction of Cu(II)L2 adsorbed on the surface of the electrode by an irreversible charge transfer to metal amalgam, Cu(0)(Hg). In the presence of DNA, the formation of the electrochemically non-active complexes Cu(II)L2–DNA results in the decrease of the equilibrium concentration of Cu(II)L2 and its peak current. Under the optimum conditions, the decrease of the peak current is proportional to DNA concentration. The linear ranges are 6.67×10−8 to 1.20×10−5 g ml−1 for calf thymus DNA (ctDNA), 3.30×10−8 to 2.33×10−6 g ml−1 for fish sperm DNA (fsDNA) and 1.0×10−8 to 1.2×10−6 g ml−1 for yeast RNA. The detection limits are 5.00×10−9, 3.00×10−9 and 2.50×10−9 g ml−1, respectively. This method exhibits good recovery and high sensitivity.  相似文献   

11.
The electrochemical detection of artemisinin generally requires high oxidation potential or the use of complex electrode modification. We find that artemisinin can react with p-aminophenylboronic acid to produce easily electrochemically detectable aminophenol for the first time. By making use of the new reaction, we report an alternative method to detect artemisinin through the determination of p-aminophenol. The calibration curve for the determination of artemisinin is linear in the range of 2 μmol L−1 to 200 μmol L−1 with the detection limit of 0.8 μmol L−1, which is more sensitive than other reported electrochemical methods. The relative standard deviation is 4.83% for the determination of 10 μM artemisinin. Because the oxidation potential of p-aminophenol is around 0 V, the present method is high selective. When 40 μM, 90 μM and 140 μM of artemisinin were spiked to compound naphthoquine phosphate tablet samples, the recoveries are 107.6%, 105.4% and 101.7%, respectively. This detection strategy is attractive for the detection of artemisinin and its derivatives. The finding that artemisinin can react with aromatic boronic acid has the potential to be exploited for the development of other sensors, such as fluorescence artemisinin sensors.  相似文献   

12.
DNA电化学传感器在DNA损伤研究中的应用   总被引:10,自引:0,他引:10  
利用单链DNA分子共价固定在石墨电极表面,采用核酸分子杂交技术,以道诺霉素作为杂交指示剂形成DNA电化学传感器.研究了在不同致突变剂的作用下,特定碱基序列的DNA在电极表面能否杂交及杂交程度的差异,探讨了DNA突变情况及可能的突变机理.  相似文献   

13.
阳离子荧光染料阿尔新蓝8GX与阴离子荧光染料四磺化铁酞菁发生缔合作用,使四磺化铁酞菁的荧光猝灭,当核酸存在时,削弱了离子缔合作用使四磺化铁酞菁的荧光恢复。荧光增强的程度与核酸的量成线性关系,据此实现了对核酸的定量测定。  相似文献   

14.
A label-free and enzyme-free sensitive fluorescent detection of human immunodeficiency virus (HIV) deoxyribonucleic acid (DNA) based on isothermal hybridization chain reaction (HCR) was developed. A G-quadruplex sequence which was incorporated into one of the two hairpin probes was inactive in the absence of target DNA. However, at the presence of target DNA numerous G-quadruplexes along DNA nanowires were self-assembled through HCR. Using N-methyl mesoporphyrin IX (NMM) as the fluorophore, a “turn-on” fluorescent response would be achieved and detected as low as 0.5 nmol L−1 of HIV DNA. This proposed method was applied to detect HIV DNA in biologic samples with satisfactory results.  相似文献   

15.
This paper describes a disposable indicator-free electrochemical DNA biosensor applied to the detection of apolipoprotein E (apoE) sequences in PCR samples. In the indicator-free assays, the duplex formation was detected by measuring the electrochemical signal of the guanine base of nucleic acids. The biosensor format involved the immobilisation of an inosine-modified (guanine-free) probe onto a screen-printed electrode (SPE) transducer and the detection of the duplex formation in connection with the square-wave voltammetric measurement of the oxidation peak of the guanine of the target sequence.The indicator-free scheme has been characterised using 23-mer oligonucleotides as model: parameters affecting the hybridisation assay such as probe immobilisation conditions, hybridisation time, use of hybridisation accelerators were examined and optimised.The analysis of PCR samples (244 bp DNA fragments, obtained by amplification of DNA extracted from human blood) required a further optimisation of the experimental procedure. In particular, a lower steric hyndrance of the probe modified surface was essential to allow an efficient hybridisation of the target DNA fragment. Negative controls have been performed using the PCR blank and amplicons unrelated to the immobilised probe. A 10 min hybridisation time allowed a full characterisation of each sample.  相似文献   

16.
In this study, SnO2 nanoparticles (SNPs)-poly(vinylferrocenium) (PVF+) modified single-use graphite electrodes were developed for electrochemical monitoring of DNA hybridization. The surfaces of polymer modified and polymer-SNP modified pencil graphite electrodes (PGEs) were firstly characterized by using SEM analysis. The electrochemical behaviours of these electrodes were also investigated using the differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS) techniques. The polymer-SNP modified PGEs were then tested for the electrochemical sensing of DNA based on the changes at the guanine oxidation signals. Experimental parameters, such as; different modifications in DNA oligonucleotides, DNA probe concentrations were examined to obtain more sensitive and selective electrochemical signals for nucleic acid hybridization. After optimization studies, DNA hybridization was investigated in the case of complementary of hepatitis B virus (HBV) probe, mismatch (MM), and noncomplementary (NC) sequences.  相似文献   

17.
Hybridization of peptide nucleic acids probe containing azobenzene (NH2-TNT4, N-PNAs) with DNA was performed by covalently immobilizing of NH2-TNT4 in sequence on the 3-mercaptopropionic acid self-assembled monolayer modified gold electrode with the helps of N-(3-dimethylaminopropy1)-N′-ethylcarbodiimide hydrochloride (EDC) and N-hydroxysuccinimide (NHS), and the hybrid was coded as N-PNAs/DNA. Using [Fe(CN)6]4−/3− (1:1) as the electrochemical indicator, the electrochemical properties of the N-PNAs self-assembled monolayer (N-PNAs-SAMs) and N-PNAs/DNA hybridization system under the conditions of before and after UV light irradiation were characterized with cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectra (EIS). Results showed that the redox currents decreased with the increase of irradiation time, suggesting that the ability of the charge transfer on the electrode surface was weakened and the conformation of hybrid system had been changed, and the control of PNAs/DNA hybridization could be realized by UV light irradiation. Supported by the National Natural Science Foundation of China (Grant No. 50572107) and “Top Hundred Talents Program” of Chinese Academy of Science  相似文献   

18.
血清样品中乙肝病毒的DNA电化学传感器检测   总被引:6,自引:0,他引:6  
利用自组装单分子膜技术,将巯己基修饰的具有乙肝病毒(HBV)DNA序列特异性的单链DNA探针固定在金电极表面,制得DNA电化学传感器;以电活性的Hoechst 33258为指示剂,考察了该传感器对血清样品中乙肝病毒DNA的响应;探讨DNA电化学传感器在临床检测中的应用;将传感器法与荧光聚合酶链反应(PCR)法进行对比,两者的分析结果具有一致性。  相似文献   

19.
In this work, a new signal amplified strategy was constructed based on isothermal exponential amplification reaction (EXPAR) and hybridization chain reaction (HCR) generating the hemin/G-quadruplex horseradish peroxidase-mimicking DNAzyme (HRP-mimicking DNAzyme) nanowires as signal output component for the sensitive detection of thrombin (TB). We employed EXPAR’s ultra-high amplification efficiency to produce a large amount of two hairpin helper DNAs within a minutes. And then the resultant two hairpin helper DNAs could autonomously assemble the hemin/G-quadruplex HRP-mimicking DNAzymes nanowires as the redox-active reporter units on the electrode surface via hybridization chain reaction (HCR). The hemin/G-quadruplex structures simultaneously served as electron transfer medium and electrocatalyst to amplify the signal in the presence of H2O2. Specifically, only when the EXPAR reaction process has occurred, the HCR could be achieved and the hemin/G-quadruplex complexes could be formed on the surface of an electrode to give a detectable signal. The proposed strategy combines the amplification power of the EXPAR, HCR, and the inherent high sensitivity of the electrochemical detection. With such design, the proposed assay showed a good linear relationship within the range of 0.1 pM–50 nM with a detection limit of 33 fM (defined as S/N = 3) for TB.  相似文献   

20.
The unique binding event between Escherichia coli single-stranded DNA binding protein (SSB) and single-stranded oligonucleotides conjugated to gold (Au) nanoparticles is utilized for the electrochemical detection of DNA hybridization. SSB was attached onto a self-assembled monolayer (SAM) of single-stranded oligonucleotide modified Au nanoparticle, and the resulting Au-tagged SSB was used as the hybridization label. Changes in the Au oxidation signal was monitored upon binding of Au tagged SSB to probe and hybrid on the electrode surface. The amplified oxidation signal of Au nanoparticles provided a detection limit of 2.17 pM target DNA, which can be applied to genetic diagnosis applications. This work presented here has important implications with regard to combining a biological binding event between a protein and DNA with a solid transducer and metal nanoparticles.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号