共查询到20条相似文献,搜索用时 0 毫秒
1.
The presence of estrogens in the aquatic environment has been the target of several studies in the last decade. Newly developed passive sampling techniques for polar organic chemicals show great promise for the assessment of long-time exposure of aquatic organisms to emerging contaminants. In the present work, two configurations of the Chemcatcher® passive sampler have been tested for their applicability to the analysis of seven estrogens in water. Accumulation experiments in the laboratory, to calculate the uptake rates, and a field trial show that the polar configuration of this device may be used for the efficient sampling and determination of estrogens in water. Time weighted average concentrations were determined in the field trial and compared with spot sampling concentrations. The detection of estriol using passive sampling, although not found with spot sampling, clearly demonstrates the value of this technique in assessing relevant concentrations of estrogens in the aquatic media. 相似文献
2.
Monobutyltin (MBT), dibutyltin (DBT) and tributyltin (TBT) were determined in natural water samples by aqueous phase ethylation with sodium tetraethylborate (STEB), room temperature trapping of the resulting volatile derivatives on Tenax TA®, followed by gas chromatography-quartz furnace atomic absorption spectrometry (GC-QFAAS). Recoveries of butyltin spikes from natural water samples were 90-109% at concentrations of ∼100 ng Sn/l. The method precision at ∼100 ng Sn/l was ≤6% RSD for butyltins spiked into natural waters. The detection limits for 1 l water samples were <1 ng Sn/l for all butyltin species. Sample throughput of the method is high (greater than three samples per hour) due to the two-stage nature of the procedure, which allows derivatisation/trapping and GC-QFAAS quantitation to be performed separately. Off-line trapping is also advantageous as it extends the life of the GC column and quartz furnace to at least 12 months due to minimisation of carry-over of co-purged material. 相似文献
3.
Evaluation of solid-phase microextraction with PDMS for air sampling of gaseous organophosphate flame-retardants and plasticizers 总被引:1,自引:0,他引:1
As an inexpensive, simple, and low-solvent consuming extraction technique, the suitability of solid-phase microextraction (SPME) with polydimethylsiloxane (PDMS) sorbent was investigated as a quantitative method for sampling gaseous organophosphate triesters in air. These compounds have become ubiquitous in indoor air, because of their widespread use as additive flame retardants/plasticizers in various indoor materials. Results obtained by sampling these compounds at controlled air concentrations using SPME and active sampling on glass fibre filters were compared to evaluate the method. A constant linear airflow of 10 cm s–1 over the fibres was applied to increase the extraction rate. For extraction of triethyl phosphate with a 100-m PDMS fibre, equilibrium was achieved after 8 h. The limit of detection was determined to be less than 10 pg m–3. The PDMS–air partition coefficients, Kfs, for the individual organophosphate triesters were determined to be in the range 5–60×106 at room temperature (22–23°C). Air measurements were performed utilising the determined coefficients for quantification. In samples taken from a lecture room four different airborne organophosphate esters were identified, the most abundant of which was tris(chloropropyl) phosphate, at the comparatively high level of 1.1 g m–3. The results from SPME and active sampling had comparable repeatability (RSD less than 17%), and the determined concentrations were also similar. The results suggest that the investigated compounds were almost entirely associated with the gaseous phase at the time and place sampled. 相似文献
4.
Determination of volatile organic compounds in contaminated air using semipermeable membrane devices
Semipermeable membrane devices (SPMDs) were evaluated as passive samplers for the determination of 26 volatile organic compounds (VOCs) in contaminated air of occupational environments. A direct methodology based on the use of head-space-gas chromatography-mass spectrometry (HS-GC-MS) was developed for VOCs determinations in SPMDs, without any sample pre-treatment and avoiding the use of solvents. A desorption temperature of 150 °C for 10 min was sufficient for a sensitive VOCs determination providing limits of detection in the range of 15 ng SPMD−1 for 21 of 26 studied compounds. Linear and equilibrium uptake models were established for each VOC from compound isotherms. Highly volatile compounds were slightly absorbed and moderately volatile compounds were strongly absorbed by SPMDs. This study is the first precedent of the use of SPMDs for the simultaneous sampling of a wide number of VOCs. The use of SPMDs is a simple and low cost alternative to ordinary sampling devices such as Radiello® diffusive samplers or badge-type solid-phase supports. 相似文献
5.
Two sorbents commonly employed for air sampling were selected for the evaluation of their suitability for the analysis of combustion gases namely Tenax TA as adsorbent and polydimethylsiloxane (PDMS) as absorbent. Target compounds were selected among the gaseous combustion products of polyurethane foam and fire-retarded polystyrene. The combustion gases were generated by burning test materials in the flame of a Bunsen burner. Gaseous combustion products were sampled simultaneously with the two sorbents using a two-way adapter, thereby exposing each sorbent to the same combustion gas atmosphere. Special attention was given to the deterioration encountered in the Tenax TA performance upon repeated combustion gas exposure, limiting its use for sampling reactive atmospheres. 相似文献
6.
Jon Volden Yngvar Thomassen Tyge Greibrokk Syvert Thorud Paal Molander 《Analytica chimica acta》2005,530(2):263-271
The storage stability of the occupationally frequently occurring compounds, methylethylketone, methylisobutylketone, benzene, toluene, tetrachloroethylene, n-butylacetate, -pinene, β-pinene, limonene and n-decane, has been investigated on the adsorbents Tenax TA, Chromosorb 106 and Carbotrap using thermally desorbable tube type samplers, commonly utilized in ambient and workroom atmospheric measurements. Fifty and 500 ng of each compound were loaded on the various adsorbents tubes, stored at both ambient (20 °C) and refrigerated (4 °C) temperatures and analysed by means of thermal gas chromatography with mass spectrometric detection on days 0, 7, 14 and 28 after exposure. A 90% storage recovery was chosen as acceptance criteria for storage stability, and statistical testing by Student's t-test, analysis of variance and Bonferroni post hoc tests were employed to investigate the effect of the categorical variables storage time, storage temperature and analyte loading on the different adsorbents. Chromosorb 106 showed the overall best behaviour with recoveries of 90% or better for all analytes during the 28-day test period. Tenax TA and Carbotrap yielded lower recoveries and were more influenced by variations in storage time, storage temperature and analyte loading. Refrigerated temperatures were best avoided for storage on Tenax TA, but may increase the recovery of some compounds on Carbotrap (e.g. n-butylacetate). The blank build-up on the adsorbents was also investigated, and Carbotrap and Tenax TA showed no signs of artefact development over time. Chromosorb 106, however, contained inherently more artefacts that build up over time, which in spite of the excellent storage capability, may limit its use in field studies where long storage times are normal. 相似文献
7.
Aguilar-Martínez R Palacios-Corvillo MA Greenwood R Mills GA Vrana B Gómez-Gómez MM 《Analytica chimica acta》2008,618(2):157-167
An integrative passive sampler (Chemcatcher®) consisting of a 47 mm C18 Empore™ disk as the receiving phase overlaid with a thin cellulose acetate diffusion membrane was developed and calibrated for the measurement of time-weighted average water concentrations of organotin compounds [monobutyltin (MBT), dibutyltin (DBT), tributlytin (TBT) and triphenyltin (TPhT)] in water. The effect of water temperature and turbulence on the uptake rate of these analytes was evaluated in the laboratory using a flow-through tank. Uptake was linear over a 14-day period being in the range: MBT (3-23 mL day−1), DBT (40-200 mL day−1), TBT (30-200 mL day−1) and TPhT (30-190 mL day−1) for all the different conditions tested. These sampling rates were high enough to permit the use of the Chemcatcher® to monitor levels of organotin compounds typically found in polluted aquatic environments. Using gas chromatography (GC) with either ICP-MS or flame photometric detection, limits of detection for the device (14-day deployment) for the different organotin compounds in water were in the range of 0.2-7.5 ng L−1, and once accumulated in the receiving phase the compounds were stable over prolonged periods. Due to anisotropic exchange kinetics, performance reference compounds could not be used with this passive sampling system to compensate for changes in sampling rate due to variations in water temperature, turbulence and biofouling of the surface of the diffusion membrane during field deployments. The performance of the Chemcatcher® was evaluated alongside spot water sampling in Alicante Habour, Spain which is known to contain elevated levels of organotin compounds. The samplers provided time-weighted average concentrations of the bioavailable fractions of the tin compounds where environmental concentrations fluctuated markedly in time. 相似文献
8.
Spas D. Spasov Miglena E. Stefanova Dimiter N. Kolev 《Monatshefte für Chemie / Chemical Monthly》1989,120(2):177-179
Summary A standardized spectrophotometric method for determination of the solubilizing activity of microbial cellulase complexes has been developed. It is based on the release of coloured compounds from microcrystalline cellulose (Avicel SF®) dyed with Levafixbrillantrot E-2B®.
Eine spektrophotometrische Methode zur Bestimmung der solubilisierenden Aktivität des Cellulase-Komplexes (Kurze Mitteilung)
Zusammenfassung Es wurde eine standardisierte spektrophotometrische Methode zur Bestimmung der Aktivität des Cellulase-Komplexes von Mikroorganismen ausgearbeitet. Die Methode beruht auf der Möglichkeit, mit Levafixbrillantrot E-2 B® gefärbte mikrokristalline Cellulose (Avicel SF®) als Substrat zu verwenden.相似文献
9.
Jagoda Drozdzak Martine Leermakers Yue Gao Vannapha Phrommavanh Michael Descostes 《Analytica chimica acta》2015
A new resin- Diphonix® in Diffusive Gradients in Thin Films (DGT) technique for the determination of uranium was investigated and compared with previously used binding phases for uranium, Chelex®-100 and Metsorb™. The DGT gel preparation and the elution procedure were optimized for the new resin. The U uptake on Diphonix® resin gel was 97.4 ± 1.5% (batch method; [U] = 20 μg L−1; 0.01 M NaNO3; pH = 7.0 ± 0.2). The optimal eluent was found to be 1 M 1-hydroxyethane-1, 1-diphosphonic acid (HEDPA) with an elution efficiency of 80 ± 4.2%. Laboratory DGT study on U accumulation using a DGT samplers with Diphonix® resin showed a very good performance across a wide range of pH (3–9) and ionic strength (0.001–0.7 M NaNO3). Diffusion coefficients of uranium at different pH were determined using both, a diffusion cell and the DGT time-series, demonstrating the necessity of the implementation of the effective diffusion coefficients into U-DGT calculations. Diphonix® resin gel exhibits greater U capacity than Chelex®-100 and Metsorb™ binding phase gels (a Diphonix® gel disc is not saturated, even with loading of 10.5 μmol U). Possible interferences with Ca2+ (up to 1.33 × 10−2 M), PO43− (up to 1.72 × 10−4 M), SO42− (up to 4.44 × 10−3 M) and −HCO3 (up to 8.20 × 10−3 M) on U-DGT uptake ([U] = 20 μg L−1) were investigated. No effect or minor effect of Ca2+, PO43−, SO42−, and −HCO3 on the quantitative measurement of U by Diphonix®-DGT was observed. The results of this study demonstrated the DGT technique with Diphonix® resin is a reliable and robust method for the measurement of labile uranium species under laboratory conditions. 相似文献
10.
The retention and complexation mechanisms of a herbicide series were studied from a chromatographic approach using a novel column called “Nautilus®”. The effects of water fraction and the hydroxy-propyl-β-cyclodextrin (HP-β-CD) concentration in the mobile phase were analysed in relation to the column temperature. Two retention models of phenoxy-propionic acid (PPA) derivatives were investigated. It was shown that the retention mechanism was led by free PPA herbicide for low HP-β-CD concentrations and by the PPA/HP-β-CD complex for the highest ones. In addition, an enthalpy-entropy compensation study revealed that both the solute retention and complexation mechanisms were independent of the number of chlorine atoms in the structure. Also the thermodynamic results showed that (1) the retention process depended on the water fraction (X) in the mobile phase and (2) the PPA/HP-β-CD complexation mechanism was shown to be entropically controlled. 相似文献
11.
The electrochemical oxidation of both the rifampicin (RIF) and isoniazid (INH) drugs has been investigated by cyclic and square-wave voltammetry in Britton-Robinson buffers (pH 2-11) at a carbon paste electrode. The oxidation of rifampicin generated a well-defined pH-dependent quasi-reversible anodic-cathodic peak couple corresponding to a mechanism involving the transfer of two electrons/two protons, typical to that of hydroquinones, in addition to an irreversible anodic peak at a more positive potential which may be due to the oxidation of phenolic hydroxyl group. For the isoniazid, an irreversible anodic peak was observed, which may be attributed to the irreversible oxidation of the amide moiety of the drug molecule. A validated square-wave adsorptive anodic stripping voltammetric procedure was described to assay the two drugs separately or combined in pharmaceutical formulations and human serum. The recoveries of RIF in rimactane® capsules (300 mg RIF) and INH in isocid® tablets (200 mg INH) were found to be 98.57±0.81% and 100.57±0.74%, respectively. The proposed procedure was also successfully applied to simultaneous assay of rifampicin and isoniazid drugs combined in rimactazid tablets (150 mg INH+300 mg RIF) with recoveries of 98.79±0.97% and 99.54±0.74%, respectively, without the necessity for sample pretreatment or time-consuming extraction steps prior to the analysis. The results were favorably compared to those obtained by the reported USP method. Moreover, the proposed procedure was successfully applied to simultaneous assay of both drugs in human serum samples with limits of detection and quantitation of 5×10−8 and 1.7×10−7 M for RIF and 6.1×10−8 and 2×10−7 M for INH. 相似文献
12.
Claudio Gardana Martina Scaglianti Paolo Simonetti 《Journal of chromatography. A》2010,1217(9):1463-1470
Stevia rebaudiana leaves contain non-cariogenic and non-caloric sweeteners (steviol-glycosides) whose consumption could exert beneficial effects on human health. Steviol-glycosides are considered safe; nonetheless, studies on animals highlighted adverse effects attributed to the aglycone steviol. The aim of the present study was to develop and validate two different ultra-high-performance liquid chromatography methods with electrospray ionization mass spectrometry (UHPLC-MS) to evaluate steviol-glycosides or steviol in Stevia leaves and commercial sweetener (Truvia®). Steviol-glycosides identity was preliminarily established by UV spectra comparison, molecular ion and product ions evaluation, while routine analyses were carried out in single ion reaction (SIR) monitoring their negative chloride adducts. Samples were sequentially extracted by methanol, cleaned-up by SPE cartridge and the analytes separated by UHPLC HSS C18 column (150 mm × 2.1 mm I.D., 1.8 μm). The use of CH2Cl2 added to the mobile phase as source of Cl− enhance sensitivity. The LLOD for stevioside, rebaudioside A, steviolbioside and steviol was 15, 50, 10 and 1 ng ml−1, respectively. Assay validation demonstrated good performances in terms of accuracy (89–103%), precision (<4.3%), repeatability (<5.7%) and linearity (40–180 mg/g). Stevioside (5.8 ± 1.3%), rebaudioside A (1.8 ± 1.2%) and rebaudioside C (1.3 ± 1.4%) were the most abundant steviol-glycosides found in samples of Stevia (n = 10) from southern Italy. Rebaudioside A was the main steviol-glycosides found in Truvia® (0.84 ± 0.03%). The amounts of steviol-glycosides obtained by the UHPLC-MS method matched those given by the traditional LC-NH2-UV method. Steviol was found in all the leaves extract (2.7–13.2 mg kg−1) but was not detected in Truvia® (<1 μg kg−1). The proposed UHPLC-MS methods can be applied for the routine quality control of Stevia leaves and their commercial preparations. 相似文献
13.
The technique of thermal desorption (TD)-GC/MS was evaluated for the measurement of monoterpenes in indoor air. The validation strategy was intentionally oriented towards routine use and the reliability of the method rather than extreme performance. For this reason, validation by accuracy profile was chosen. The accuracy profile procedure, which is based on the concept of total error (bias + standard deviation), guarantees that a known proportion of future results obtained with the method will be within acceptance limits. For all the compounds tested in the present study, α-pinene, α-terpineol, β-pinene, d-limonene, Δ3-carene, camphene, 1,8-cineole, p-cymene, linalool, but not in the case of carvone, the accuracy profile procedure established that at least 95% of the future results obtained would be within the ±15% acceptance limits of the validated method over the whole defined concentration range. Other parameters, such as selectivity, recovery, repeatability, stability of the molecules of interest and the effect of temperature, were also determined. The performance of the described method was finally evaluated by the analysis of indoor air from new timber frame constructions. 相似文献
14.
Michael Leuck Rubina Giare Matthias Paul Nicole Zien Andreas Wolter 《Tetrahedron letters》2004,45(2):317-320
A novel improved controlled pore glass (CPG) support based on the 2-(hydroxymethyl)-6-nitrobenzoyl (HMNB) protecting group was developed for the synthesis of 3′-aminoalkylated oligonucleotides. The release of oligonucleotides with free 3′-amino groups from the support is complete within 2 h at 55 °C in concentrated ammonia. 相似文献
15.
Calone 1951®, 7-methyl-benzo[b][1,4]dioxepin-3-one, possesses a strong marine, ozone note with floral nuances and is synthesised via a three-step procedure using microwave irradiation. High yields were obtained, and reaction times reduced to a few minutes, allowing for an efficient and inexpensive synthesis of Calone 1951®. 相似文献
16.
Summary A simple method is described for the collection of volatile compounds from a biological matrix and for their subsequent GC-MS
analysis. (E)-2-decenal and (E)-2-decenyl acetate odorous compounds from bugs of theNezara viridula species were detected together with n-dodecane and n-tridecane hydrocarbons as carriers. The chemical composition of the
secretions of the bugs collected in the Veneto region corresponds to one obtained from the same American pentatomidae. 相似文献
17.
Sara Filippi Massimo PaciGiovanni Polacco Nadka Tzankova DintchevaPierluigi Magagnini 《Polymer Degradation and Stability》2011,96(5):823-832
When used as a nanofiller for the preparation of polymer/clay nanocomposites (PCNs), Cloisite® 30B (30B) often undergoes a d-spacing collapse, as demonstrated by a shift to wider angles of the XRD basal reflection. Such collapse has been variously attributed to organoclay contamination or, more often, to thermal degradation of the organic modifier with expulsion of the volatile products from the galleries. In this work, several PCNs loaded with 30B have been prepared by melt compounding, using different polymer matrices, and have subsequently been subjected to dissolution in appropriate solvents followed by precipitation in excess non-solvent and room temperature drying. An XRD analysis of the products has shown that this treatment makes the 30B basal plane reflection go back to the original angular position. These experiments indicate that, contrary to the situation prevailing when 30B is subjected to thermal treatments at temperatures well above the onset of degradation (∼180 °C), the d-spacing collapse observed after melt compounding 30B with polymer matrices at moderate temperatures is in fact a reversible phenomenon probably due to rearrangement of the alkyl chains of the clay modifier in a disposition intermediate between bilayer and monolayer. 相似文献
18.
Oxygenation of various aldimines with tetrabutylammonium monoperoxysulfate produced the corresponding E- or a mixture of E- and Z-oxaziridines with very high yields (?90%) and good to excellent selectivities (75-100%) within 20 min to 10 h in CH3CN at room temperature (∼25 °C). The E/Z isomer ratio critically depends on the stereo-electronic nature of the substituents in the oxaziridines, solvent, and the presence of Lewis acids and bases. 相似文献
19.
Laurent Porrès 《Tetrahedron letters》2006,47(12):1913-1917
The synthesis and the characterization of new multichromophoric boron-dipyrromethene dyes are described. Their absorption, photoluminescence as well as their two-photon absorption properties have been investigated. This work shows that assembling several dyes in conjugated multichromophoric structures is a promising strategy for improving the two-photon absorption properties of such fluorophores in the NIR region while retaining their excellent photoluminescence properties. 相似文献
20.
Epoxidation of cyclooctene and other alkenes with Oxone® was promoted effectively in an aqueous micellar solution of an amphiphilic ketone, which was easily derived from hepta(ethylene glycol) monodecyl ether. 相似文献