首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We report a qualitative liquid chromatography–tandem mass spectrometry (LC/MS/MS) method for the simultaneous analysis of the three known N,N‐dimethyltryptamine endogenous hallucinogens, their precursors and metabolites, as well as melatonin and its metabolic precursors. The method was characterized using artificial cerebrospinal fluid (aCSF) as the matrix and was subsequently applied to the analysis of rat brain pineal gland‐aCSF microdialysate. The method describes the simultaneous analysis of 23 chemically diverse compounds plus a deuterated internal standard by direct injection, requiring no dilution or extraction of the samples. The results demonstrate that this is a simple, sensitive, specific and direct approach to the qualitative analysis of these compounds in this matrix. The protocol also employs stringent MS confirmatory criteria for the detection and confirmation of the compounds examined, including exact mass measurements. The excellent limits of detection and broad scope make it a valuable research tool for examining the endogenous hallucinogen pathways in the central nervous system. We report here, for the first time, the presence of N,N‐dimethyltryptamine in pineal gland microdialysate obtained from the rat. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

2.
In this study, a sensitive liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed and validated for the quantification of demethylzeylasteral in rat plasma. Electrospray ionization was operated in the negative ion mode while demethylzeylasteral and oleanolic acid (internal standard) were measured by selected reaction monitoring (demethylzeylasteral: m/z 479.2 → 436.0; oleanolic acid: m/z 454.9 → 407.2). This LC–MS/MS method had good selectivity, sensitivity, accuracy and precision. The pharmacokinetic profiles of demethylzeylasteral were subsequently examined in Wistar rats after oral or intravenous administration.  相似文献   

3.
An ion-pairing liquid chromatography/electrospray tandem mass spectrometry (LC/ES-MS/MS) method with in vivo microdialysis for the determination of amphetamine in rat brain has been developed. A microdialysis probe was surgically implanted into the striatum of the rat and artificial cerebrospinal fluid (aCSF) was used as the perfusion medium. Samples were collected and then analyzed off-line by LC/ES-MS/MS. A reversed-phase C18 column was employed for LC separation and MS/MS was utilized for detection. Trifluoroacetic acid (TFA) was added to the mobile phase (acetonitrile/water) as an ion-pairing reagent. Detection was by ES-MS/MS directly, and no post-column addition of organic modifier was needed. Dual linear ranges were determined from 0.1-0.5 microg/mL and 0.005-0.1 microg/mL, respectively. The detection limit, based on a signal-to-noise ratio of 3, was 0.001 microg/mL (5 nM). Good precision and accuracy were obtained. The applicability of this newly developed method was demonstrated by continuous monitoring of amphetamine concentrations in rat brain. Amphetamine reached a maximum concentration of 0.086 +/- 0.017 microg/mL over 20-40 min after a single 3.0 mg/kg intraperitoneal administration.  相似文献   

4.
A sensitive liquid chromatograph/tandem mass spectrometric technique (LC/MS/MS) was applied to determine aliphatic and aromatic carbonyl compounds in ambient air. Traces of the carbonyl compounds were sampled by passing through a Sep-Pak DNPH-silica cartridge. Their derivatives were thus eluted with acetonitrile, separated by reversed-phase liquid chromatography and determined by quadrupole tandem mass spectrometry in an atmospheric pressure chemical ionization (APCI) mode with multiple reaction monitoring (MRM). The detection limits (DL) of the carbonyl compounds were 0.8 - 15 ng/m3. A number of the carbonyl compounds were detected at n.d.- 14 microg/m3 levels. The precursor ion scanning analysis was applied to identify the unknown compounds.  相似文献   

5.
Since the wide adoption of liquid chromatography/tandem mass spectrometry (LC/MS/MS), the ion suppression/enhancement phenomenon is the latest barrier to high-throughput analysis. This consequence of a nonoptimized analytical method can lead to adverse effects during quantitation (i.e. poor accuracy and precision). Previous papers have reported that ion suppression is a direct result of endogenous material present in biological samples. However, in the case of a solid-phase liquid chromatography/tandem mass spectrometry (SPE/LC/MS/MS) system, the measured result is the combination of several operating conditions and parameters. Little has been done to effectively monitor and/or choose optimized conditions for the complete sequence of extraction, clean up, separation and analysis. This paper describes a simple setup for quantification of ion suppression/enhancement. Several mobile phase additives, ion-pairing agents and SPE extracts were measured and compared against a standard reference. The results demonstrated that a clean up of plasma extracts based on ion exchange leads to minimal ion suppression/enhancement for the compounds that were investigated.  相似文献   

6.
Acetycholinesterase (AChE) that regulates hydrolysis of acetylcholine (ACh) in the brain, is an important target for treatment of Alzheimer's disease (AD), a feature of which is ACh deficiency. However, the methods to precisely determine AChE activity are still under development. We developed a new method to exploit acetylcholine‐d4 as a surrogate substrate of ACh and measure product choline‐d4 via liquid chromatography–tandem mass spectrometry (LC–MS/MS). This assay detected activity of AChE present in the normal mouse brain, which is consistent with the standard Ellman assay that determines products spectrophotometrically. In AD mouse models, the result of LC–MS/MS assay showed significant higher AChE activity than that seen in control normal mice, while treatment of AD mice with an AChE inhibitor, huperzine A, led to partial decreases in AChE activity. Our results suggest that this surrogate‐based LC–MS/MS method is a new, sensitive and convenient assay for the determination of AChE activity, providing a useful means for screening active compounds that target AChE.  相似文献   

7.
Steroid sex hormones and related synthetic compounds have been shown to provoke alarming estrogenic effects in aquatic organisms, such as feminization, at very low concentrations (ng/L or pg/L). In this work, different chromatographic techniques, namely, gas chromatography/mass spectrometry (GC/MS), liquid chromatography/mass spectrometry (LC/MS) and liquid chromatography/tandem mass spectrometry (LC/MS/MS), are discussed for the analysis of estrogens, both free and conjugated, and progestogens, and the sensitivities achieved with the various techniques are inter-compared. GC/MS analyses are usually carried out after derivatization of the analytes with bis(trimethylsilyl)trifluoroacetamide (BSTFA). For LC/MS and LC/MS/MS analyses, different instruments, ionization techniques (electrospray (ESI) and atmospheric pressure chemical ionization (APCI)), ionization modes (negative ion (NI) and positive ion (PI)) and monitoring modes (selected ion monitoring (SIM) and selected reaction monitoring (SRM)) are generally employed. Based on sensitivity and selectivity, LC/ESI-MS/MS is generally the method of choice for determination of estrogens in the NI mode and of progestogens in the PI mode (instrumental detection limits (IDLs) 0.1-10 ng/mL). IDLs achieved by LC/ESI-MS in the SIM mode and by LC/ESI-MS/MS in the SRM mode were, in general, comparable, although the selectivity of the latter is significantly higher and essential to avoid false positive determinations in the analysis of real samples. Conclusions and future perspectives are outlined.  相似文献   

8.
Tomato (Lycopersicon esculentum Mill.) is the second most important fruit crop worldwide. Tomatoes are a key component in the Mediterranean diet, which is strongly associated with a reduced risk of chronic degenerative diseases. In this work, we use a combination of mass spectrometry (MS) techniques with negative ion detection, liquid chromatography/electrospray ionization linear ion trap quadrupole‐Orbitrap‐mass spectrometry (LC/ESI‐LTQ‐Orbitrap‐MS) and liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS) on a triple quadrupole, for the identification of the constituents of tomato samples. First, we tested for the presence of polyphenolic compounds through generic MS/MS experiments such as neutral loss and precursor ion scans on the triple quadrupole system. Confirmation of the compounds previously identified was accomplished by injection into the high‐resolution system (LTQ‐Orbitrap) using accurate mass measurements in MS, MS2 and MS3 modes. In this way, 38 compounds were identified in tomato samples with very good mass accuracy (<2 mDa), three of them, as far as we know, not previously reported in tomato samples. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

9.
The curcuminoids are a group of diarylheptanoid molecules that possess important pharmacological activities, particularly acting as anti-inflammatory agents. The main purpose of this study was to investigate the fragmentation behavior of the three major curcuminoids in ion trap liquid chromatography/tandem mass spectrometry (LC/MS/MS). Both positive and negative mode electrospray ionization in tandem and multidimensional MS(n) experiments in quadrupole ion trap instruments and high-resolution and accurate mass MS and sustained off-resonance irradiation (SORI) MS/MS experiments in a Fourier transform ion cyclotron resonance (FTICR) mass spectrometer were used to elucidate the main fragmentation channels of these compounds. These experiments yielded essentially the same fragmentation results in both ion trap and ICR instruments for all three curcuminoids and for their phenolic monoacetates. Major and diagnostic fragment ions were identified and their origins are proposed.  相似文献   

10.
All four regioisomers of feruloyl quinic acid and isoferuloyl quinic acid were synthesized and a liquid chromatography/tandem mass spectrometry (LC/MS/MS) method developed that resolves all eight regioisomers. All eight regioisomers can be readily distinguished by their MS/MS spectra in the negative ion mode, illustrating the power of tandem mass spectrometry to elucidate the structures of regioisomeric compounds. Compound identification is possible, either by direct comparison of spectral fingerprints or by rational probing of diagnostic fragment ions, thus allowing the identification of these important classes of natural products and potential human metabolites. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

11.
Environmental analytical chemistry has recently changed focus from analysis of non-polar, persistent contaminants (e.g. polychlorinated biphenyls and dioxins) to more polar and labile compounds that interfere with biological processes. For example, natural and synthetic estrogens and their metabolites have been detected in sewage treatment plant effluents at nanogram/liter concentrations that are similar to those at which both total sex reversal and intersex (containing both testes and ova) is induced in fish exposed to these compounds in laboratory experiments. The development of techniques for the analysis of natural and synthetic estrogens in biological fluids (i.e. serum and urine) has been a priority in the biomedical field. However, the recent recognition that estrogen hormones are contaminants in the environment that may contribute to endocrine disruption has focused attention on the need for highly sensitive and specific techniques that are applicable for trace analysis in complex environmental matrices. Three optimized mass spectrometric protocols have been developed for the determination and quantitation of steroid hormones in environmental matrices using gas chromatography/tandem mass spectrometry (GC/MS/MS), liquid chromatography/mass spectrometry selected ion monitoring, (LC/MS - SIM) and liquid chromatography/tandem mass spectrometry (LC/MS/MS). The advantages and disadvantages of each method are presented.  相似文献   

12.
The occurrence of phenolic compounds in apple residues resulting from the juice industry was investigated to provide an alternative use for this raw material. For the identification of these compounds, liquid chromatography coupled to ionspray mass spectrometry in tandem mode (LC/MS/MS) with negative ion detection was used. The residues were first extracted and then chromatographed on Sephadex LH-20 to yield 13 fractions. Positive identification of the compounds was based on their retention times and mass spectra in full scan mode (MS), and in different MS/MS modes (product ion scan, precursor ion scan and neutral loss scan). In this way, 60 compounds, including cinnamic and benzoic acid derivatives and flavonoids, were identified, some of them not previously reported in apple waste.  相似文献   

13.
Gas chromatography/mass spectrometry (GC/MS) is applied to the analysis of volatile and thermally stable compounds, while liquid chromatography/atmospheric pressure chemical ionization mass spectrometry (LC/APCI‐MS) and liquid chromatography/electrospray ionization mass spectrometry (LC/ESI‐MS) are preferred for the analysis of compounds with solution acid‐base chemistry. Because organic explosives are compounds with low polarity and some of them are thermally labile, they have not been very well analyzed by GC/MS, LC/APCI‐MS and LC/ESI‐MS. Herein, we demonstrate liquid chromatography/negative ion atmospheric pressure photoionization mass spectrometry (LC/NI‐APPI‐MS) as a novel and highly sensitive method for their analysis. Using LC/NI‐APPI‐MS, limits of quantification (LOQs) of nitroaromatics and nitramines down to the middle pg range have been achieved in full MS scan mode, which are approximately one order to two orders magnitude lower than those previously reported using GC/MS or LC/APCI‐MS. The calibration dynamic ranges achieved by LC/NI‐APPI‐MS are also wider than those using GC/MS and LC/APCI‐MS. The reproducibility of LC/NI‐APPI‐MS is also very reliable, with the intraday and interday variabilities by coefficient of variation (CV) of 0.2–3.4% and 0.6–1.9% for 2,4,6‐trinitrotoluene (2,4,6‐TNT). Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

14.
A method is described for the evaluation of drug concentrations in plasma and brain from treated rats. The analyte is recovered from plasma or brain homogenate by liquid-liquid extraction and subsequently analyzed by liquid chromatography/tandem mass spectrometry (LC/MS/MS). A simple experimental protocol renders the procedure valuable for obtaining information rapidly on brain penetration and plasma exposure of specific classes of compounds. This methodology has been applied to evaluate brain penetration with 30 different compounds from the same discovery program. In an attempt to increase throughput in our screening efforts, mixture dosing was evaluated. Results from single compound administration were compared with results following administration of a mixture of four compounds. Preliminary results, with specific classes of compounds, show no major differences (ranking order) in brain or plasma concentrations between mixture dosing and single compound administration, suggesting that mixture dosing could be applicable to brain penetration studies in the drug discovery phase.  相似文献   

15.
A fast, simple and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed for the determination of acetylcholine in rat brain microdialysis samples. The chromatographic separation was achieved in 3 min on a reversed-phase column with isocratic conditions using a mobile phase containing 2% (v/v) of acetonitrile and 0.05% (v/v) of trifluoroacetic acid (TFA). A stable isotope-labeled internal standard was included in the analysis and detection was carried out with a linear ion trap mass spectrometer using selected reaction monitoring (SRM). Analyte ionization was performed with an atmospheric pressure chemical ionization (APCI) source without applying discharge current (atmospheric pressure spray ionization). This special ionization technique offered significant advantages over electrospray ionization for the analysis of acetylcholine with reversed-phase ion-pairing chromatography. The lower limit of quantification was 0.15 nM (1.5 fmol on-column) and linearity was maintained over the range of 0.15-73 nM, providing a concentration range that is significantly wider than that of the existing LC/MS methods. Good accuracy and precision were obtained for concentrations within the standard curve range. The method was validated and has been used extensively for the determination of acetylcholine in rat brain microdialysis samples.  相似文献   

16.
Because of the lack of a UV chromophore and their much smaller abundances in comparison with the major component, the minor components in erythromycin estolate preparations are difficult to analyze by high performance liquid chromatography ultraviolet (HPLC-UV). Tentative assignment of the major and minor components can be achieved with the combination of full scan and ZoomScan using an ion trap mass spectrometer. Tandem mass spectrometry (MS/MS) provided an effective method to quickly identify most components without chromatographic separation, and all the related compounds, except the isobaric pair ECE and PdMeEA, could be identified in this way. The best result was obtained by using liquid chromatography/tandem mass spectrometry (LC/MS/MS) operated in selected reaction monitoring mode. The major compound, the estolate of erythromycin A (EAE), and seven other minor components, could be separated and identified, with semiquantitative estimates of relative concentrations.  相似文献   

17.
We report a liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for analyzing bisphenol A (BPA) and its halogenated derivatives. Since only tetrachlorobisphenol A and tetrabromobisphenol A (TBBPA) are commercially available, mono-, di- and trichlorobisphenol A were synthesized and purified in order to be used as analytical standards. This family of compounds was studied using electrospray ionization and an ion trap mass analyzer in order to characterize the new compounds and to propose fragmentation pathways. Multi-stage mass spectrometry was used to confirm the genealogical relationship between the ions. Some product ions were traced from MS/MS to MS(4) and the labelled compounds BPA-d(16) and TBBPA-(13)C(12) were used to assign some product ion structures. In general, the deprotonated molecule [M--H](-) loses a methyl and/or a halogen group during both MS/MS and MS(3), while the neutral loss of CO was also observed in MS(3) spectra. We selected the most intense and characteristic MS/MS transitions for LC/MS/MS analysis. LC separation was performed in a reversed-phase column; methanol/water (no additives) was used as the mobile phase in gradient elution mode; and BPA-d(16) was chosen as the internal standard. Solid-phase extraction (SPE) was used to pre-concentrate and to clean up water samples. The SPE LC/MS/MS method allows BPA and its halogenated derivatives to be detected at a few parts-per-billion (ppb) in surface water.  相似文献   

18.
We have developed and validated a sensitive method for the simultaneous determination of some monoamine neurotransmitters like dopamine (DA), norepinephrine (NE) and serotonin (5-HT) in rat brain microdialysate using high-performance liquid chromatography coupled to tandem mass spectrometry (LC/MS/MS). Sensitivity enhancement has been achieved by amine derivatization with the reagent (5-N-succinimidoxy-5-oxopentyl)triphenylphosphonium bromide (SPTPP) under mild conditions. The use of the selected reaction monitoring (SRM) mode has allowed detection of the analytes at a concentration of 30 pM (lower limit of quantification, LLOQ, signal-to-noise ratio higher than 5) with an accuracy of ≤3.80% and a precision of ±7.39 (%CV) for all neurotransmitters. Derivatization improves resolution and chromatographic retention times (3 min) by lipophilization. Linearity has been good (R > 0.99) over a large concentration range (30–50,000 pM). The intra and inter-batch accuracy and precision were not greater than 4.8% and 6.4%, respectively. Therefore, the method was successfully applied for monitoring the concentration changes of neurotransmitters in microdialysis samples deriving from striatum rat brain region after amphetamine administration (3 mg kg−1, i.p.).  相似文献   

19.
Icotinib, 4-[(3-ethynylphenyl)amino]-6,7-benzo-12-crown-4-quinazoline, is a new antitumor agent. The metabolic pathway of icotinib in rats was studied using liquid chromatography/tandem mass spectrometry (LC/MS(n)) analysis. Full scan and selected ion monitoring modes were used to profile the possible metabolites of icotinib in rat urine, feces and bile samples. Four phase I metabolites (M1-M4) and two phase II metabolites (M5, M6) were detected and characterized. Multiple-stage mass spectrometry and nuclear magnetic resonance (NMR) spectrometry were employed to elucidate structures of metabolites. Icotinib was metabolized to open the crown ether ring to form the main phase I metabolites. During metabolism, a reactive metabolite was formed. Using semicarbazide as a trapping agent, an intermediate arising from opening of the crown ether ring was detected as an aldehyde product by LC/MS/MS. These data indicated that ring opening of the crown ether was triggered by hydroxylation at the 8'-position of the ring to form a hemiacetal intermediate, which was further oxidized or reduced. Finally, the metabolic pathway of icotinib in rats was proposed.  相似文献   

20.
Quantitative analysis of liquid chromatography (LC)-mass spectrometry (MS) and tandem mass spectrometry (MS/MS) data is essential to many proteomics studies. We have developed MASIC(2) to accurately measure peptide abundances and LC elution times in LC-MS/MS analyses. This software program uses an efficient processing algorithm to quickly generate mass specific selected ion chromatograms from a dataset and provides an interactive browser that allows users to examine individual chromatograms with a variety of options.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号