首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 296 毫秒
1.
A sensitive and selective electrochemical method for the determination of dopamine using an Evans Blue polymer film modified on glassy carbon electrode was developed. The Evans blue polymer film modified electrode shows excellent electrocatalytic activity toward the oxidation of dopamine in phosphate buffer solution (pH 4.5). The linear range of 1.0 x 10(-6)-3.0 x 10(-5) M and detection limit of 2.5 x 10(-7) M were observed in pH 4.5 phosphate buffer solutions. The interference studies showed that the modified electrode exhibits excellent selectivity in the presence of large excess of ascorbic acid and uric acid. The separation of the oxidation peak potentials for dopamine-ascorbic acid and dopamine-uric acid were about 182 mV and 180 mV, respectively. The differences are large enough to determine AA, DA and UA individually and simultaneously. This work provides a simple and easy approach to selectively detect dopamine in the presence of ascorbic acid and uric acid in physiological samples.  相似文献   

2.
A novel kinetic spectrofluorimetric method for the determination of uric acid based on the activation effect of uric acid on the Cu(II) ion catalyzed oxidation of pyronine Y by hydrogen peroxide was developed. The influence of different buffer solutions was tested and the Britton-Robinson buffer solution with pH 2.2 was found to be the optimum. The detection limit and the linear range for uric acid are 0.09 μg mL−1 and 0.3–3.0 μg mL−1, respectively. The RSD for eleven determinations of 1.6 μg mL−1 uric acid was 1.6 %. Satisfactory results were obtained when using this method of uric acid determination in human urine.  相似文献   

3.
The voltammetric behavior of uric acid was studied at a single-walled carbon nanotube (SWNT) modified gold electrode. Uric acid can effectively accumulate at this electrode and produce an anodic peak at about 0.45 V (vs. SCE) in pH 5.0 sodium acetate buffer solutions (HAc-NaAc). The experimental parameters, such as solution pH, accumulation time, and amount of SWNT, were optimized for determination. Under the optimum conditions, the anodic peak current is linear to the uric acid concentration over the range of 1.0×10−7 M to 2.5×10−5 M with a correlation coefficient of 0.998. The detection limit was 5.0×10−8 M for 60 s accumulation. The electrode could be easily regenerated and exhibited good stability. A 5.0×10−6 M uric acid solution was measured ten times using the same electrode, and the relative standard deviation of the peak current was 1.3%. This method was successfully applied to the determination of uric acid in human urine samples, and the recovery was 97–99%. The feasibility for simultaneous determination of xanthine, ascorbic acid and uric acid was discussed. These species did not interfere with each other in a certain concentration range. The influence of some surfactants on the anodic peak was also examined.  相似文献   

4.
The oxidation of uric and of four N-methyluric acids in aqueous solution was studied by EPR spectroscopy. The primary oxidising radicals react with uric acid and its methyl derivatives by formal hydrogen abstraction from an NH group to yield radical-anions in neutral or moderately basic solutions and the respective radical-dianions in basic media. In the case of uric acid, the radical-trianion was detected at very high pH. The pKa values of the radical-anions were determined to be in the range 9.5-11.2. The pKa of uric acid radical-dianion was estimated to be 13.0. DFT calculations were performed to assign the hyperfine coupling constants and to determine the predominant tautomeric structure of the radicals. The uric acid radical-anion exists as the N1H, N9H tautomer, while in the radical-dianion the N1H structure is the most stable one. The intrinsic acidity of the NH protons both in uric acid and in its radicals seems to follow the order N1H < N9H < N3H.  相似文献   

5.
The growth of anhydrous uric acid (UA) and uric acid dihydrate (UAD) crystals from supersaturated aqueous solutions containing methylene blue, a cationic organic dye, has been investigated. Low concentrations of dye molecules were found to be included in both types of crystal matrixes during the growth process. Incorporation of dye into UA crystals occurs with high specificity, affecting primarily [001] and [201] growth sectors, while UAD crystals grown from solutions of similar dye concentration show inclusion but little specificity. The orientation of the UA-trapped species was determined from polarization data obtained from visible light microspectrometry. To achieve charge neutrality, a second anionic species must also be included with the methylene blue into UA and UAD crystal matrices. Under high pH conditions, crystallization of 1:1 stoichiometric mixtures of methylene blue and urate yields methylene blue hexahydrate (MBU.6(H2O). The crystal structure of MBU.6(H2O) reveals continuous pi-pi stacks of planes of dye cations and urate anions mediated by water molecules. This structure provides an optimal geometry for methylene blue-urate pairs and additional support for the incorporation of these dimers in uric acid single-crystal matrices. The strikingly different inclusion patterns in UA and UAD demonstrate that subtle changes in the crystal surfaces and/or growth dynamics can greatly affect recognition events.  相似文献   

6.
The solvatochromic responses of uric acid (Ua), 6-amino-2-thiouracil (ATU) and a series of their complexes dissolved in ten solvents of different polarity have been measured. The solvent-dependent UV/Vis spectroscopic absorption maxima, λ(max), are assigned to the corresponding electronic transitions and analyzed using SPSS program, regression analysis and Kamlet and Taft methods. The observed solvatochromism is discussed using various solute-solvent interaction mechanisms. The electronic absorption spectra of ATU were investigated in aqueous buffer solutions of varying pH and utilized for the determination of dissociation constants. The ranges of pH, where individual ionic species are predominant have been determined.  相似文献   

7.
Hoshi T  Saiki H  Anzai J 《Talanta》2003,61(3):363-368
Uricase (UOx) and polyelectrolyte were used for preparation of a permselective multilayer film and enzyme multilayer films on a platinum (Pt) electrode, allowing the detection of uric acid amperometrically. The polyelectrolyte multilayer (PEM) film composed of poly(allylamine) (PAA) and poly(vinyl sulfate) (PVS) were prepared via layer-by-layer assembly on the electrode, functioning as H2O2-selective film. After deposition of the permselective film (PAA/PVS)2PAA, UOx and PAA were deposited via layer-by-layer sequential deposition up to 10 UOx layers to prepare amperometric sensors for uric acid. Current response to uric acid was recorded at +0.6 V vs. Ag/AgCl to detect H2O2 produced from the enzyme reaction. The response current increased with increasing the number of UOx layers. Even in the presence of ascorbic acid, uric acid can be detected over the concentration range 10−6-10−3 M. The response current and deposited amount of UOx were affected by deposition bath pH and the addition of salt. The deposition of PAA/UOx film prepared in 2 mg ml−1 solution (pH 11) of PAA with NaCl (8 mg ml−1) and 0.1 mg ml−1 solution (pH 8.5) of UOx with borate (100 mM) resulted in an electrode which shows the largest response to uric acid. The response of the sensor to uric acid was decreased by 40% from the original activity after 30 days.  相似文献   

8.
A reliable and reproducible method for the determination of uric acid in urine samples has been developed. The method is based on the modification of a glassy carbon electrode by 3-acetylthiophene using cyclic voltammetry. The poly(3-acetylthiophene) modified glassy carbon electrode showed an excellent electrocatalytic effect towards the oxidation of uric acid in 0.1 m phosphate buffer solution (PBS) at pH 7.2. Compared with a bare glassy carbon electrode (GCE), an obvious shift of the oxidation peak potential in the cathodic direction and a marked enhancement of the anodic current response for uric acid were observed. The poly(3-acetylthiophene)/GCE was used for the determination of uric acid using square wave voltammetry. The peak current increased linearly with the concentration of uric acid in the range of 1.25 x 10(-5)-1.75 x 10(-4) M. The detection limit was 5.27 x 10(-7) M by square wave voltammetry. The poly(3-acetylthiophene)/GCE was also effective to determine uric acid and ascorbic acid in a mixture and resolved the overlapping anodic peaks of these two species into two well-defined voltammetric peaks in cyclic voltammetry at 0.030 V and 0.320 V (vs. Ag/AgCl) for ascorbic acid and uric acid, respectively. The modified electrode exhibited stable and sensitive current responses toward uric acid and ascorbic acid. The method has successfully been applied for determination of uric acid in urine samples.  相似文献   

9.
Uchiyama S  Sakamoto H 《Talanta》1997,44(8):1435-1439
Electropolymerizations of aniline and pyrrole solutions containing uricase at a neutral pH was performed to immobilize the enzyme on the surface of the gas diffusion carbon felt, and a selective uric acid sensor was fabricated by combining immobilized enzyme carbon felt and an oxygen electrode with oxygen gas permeable membrane. This carbon felt has a desirable feature for uricase sensing because an extremely efficient supply of oxygen for the enzymatic reaction can be realized due to its porosity permitting a transfer of oxygen. The current response time required from when sample is added until when current reaches the steady-state value is <5 min. The calibration graph of uric acid showed a linear line in a concentration range from 1x10(-5) to 4x10(-4) M with a detection limit of 4x10(-6) M.  相似文献   

10.
《Electroanalysis》2005,17(24):2281-2286
A poly(3,4‐ethylenedioxythiophene) (PEDOT) modified glassy carbon electrode (GCE) was used to determine uric acid in the presence of ascorbic acid at physiological pH facilitating a peak potential separation of ascorbic acid and uric acid oxidation (ca. 365 mV), which is the largest value reported so far in the literature. Also, an analytical protocol involving differential pulse voltammetry has been developed using a microchip electrode for the determination of uric acid in the concentration range of 1 to 20 μM in presence of excess of ascorbic acid.  相似文献   

11.
Two key steps in kidney stone formation--crystal aggregation and attachment to renal tissues--depend on the surface adhesion properties of the crystalline components. Anhydrous uric acid (UA) is the most common organic crystalline phase found in human kidney stones. Using chemical force microscopy, the adhesion force between various functional groups and the largest (100) surface of UA single crystals was measured in both aqueous solution and model urine. Adhesion trends in the two solutions were identical, but were consistently lower in the latter. Changes in the solution ionic strength and pH were also found to affect the magnitude of the adhesion. UA surfaces showed the strongest adhesion to cationic functionalities, which is consistent with ionization of some surface uric acid molecules to urate. Although hydrogen-bonding and van der Waals interactions are usually considered to be dominant forces in the association between neutral organic compounds, this work demonstrates that electrostatic interactions can be important, particularly when dealing with weak acids under certain solution conditions.  相似文献   

12.
The pH and Hammett acidity dependences of the absorption and fluorescence spectra of cinchoninic acid (quinoline-4-carboxylic acid), cinchophen (2-phenylquinoline-4-carboxylic acid) and their methyl esters, were studied. The predominant uncharged ground-state species derived from the free acids are zwitterions. Prototropic equilibria are too slow to compete with fluorescence for deactivation of the excited state at hydrogen ion concentrations represented by the pH scale. However, fluorescence shifts accompanying protonation indicate that the carboxyl group is more basic than the ring nitrogen atom in the excited state. In the Hammett acidity range the singly-charged cations of all the compounds studied undergo phototautomerism in the lowest excited singlet state. The rate of this process is acidity dependent. In very concentrated sulphuric acid solutions doubly-charged cations are formed in the excited state but not in the ground state. The intense emissions of these compounds in moderately concentrated sulphuric acid may be suitable for quantitative analysis if great care is taken to control solution acidity.  相似文献   

13.
Hasebe Y  Nawa K  Ujita S  Uchiyama S 《The Analyst》1998,123(8):1775-1780
The principle of the signal amplification of a uric acid sensor based on dithiothreitol (DTT)-mediated intermediate regeneration of uricase was applied to a flow-injection system with an immobilized uricase reactor and a DTT-containing carrier. Highly sensitive detection for nM to microM order of uric acid was achieved when 10 mM TRIS-HCl buffer (pH 10.0) containing 20 mM DTT was used as a carrier at 0.6 ml min-1 and 37 degrees C. The sensitivity of the uric acid was much improved over a batch method using a uricase membrane-coupling electrode, and the detection limit (ca. peak current 8 nA) of uric acid was found to be down to 3 x 10(-10) M (amplification factor; more than 10,000). This chemically amplified flow-system is very useful for the direct assay of uric acid in highly diluted biological fluids (urine and serum) without complicated pretreatment of the samples, because this sensor has the potential to detect trace amounts (nM to microM) of uric acid in highly diluted body fluids in which the concentration of interfering constituents was decreased to negligible levels. Good correlation was observed between this system and conventional spectrophotometry. The immobilized uricase reactor could be re-used for at least 4 months of repeated analysis without loss of activity and was stable if stored at 4 degrees C in 10 mM TRIS-HCl buffer, pH 9.0.  相似文献   

14.
A simple and reliable method based on capillary electrophoresis with electrochemical detection (CE–ED) was applied to study the effect of aerobic exercises on creatinine and uric acid concertration in saliva and urine. The pH value, the running buffer concentration, the SDS concentration, separation voltage, injection time and the potential applied to the working electrode were investigated to find the optimum conditions. The detection limits (S/N = 3) for creatinine and uric acid were 3.6 μmol L?1 and 0.86 μmol L?1, respectively. This method was successfully used in the rapid analysis of creatinine and uric acid in saliva samples. After aerobic exercises, creatinine concentration decreased, and uric acid concentration increased in saliva. In urine, the concentrations of creatinine and uric acid both increased after exercise.  相似文献   

15.
A graphene-modified glassy carbon electrode was obtained via drop-casting method and applied to the simultaneous detection of epinephrine, uric acid, and ascorbic acid by cyclic voltammetry in a phosphate buffer solution (pH 3.0). The oxidation potentials of epinephrine, uric acid, and ascorbic acid were 0.484, 0.650, and 0.184 V at the graphene-modified glassy carbon electrode, respectively. The peak separation between epinephrine Pand uric acid, epinephrine and ascorbic acid, and uric acid and ascorbic acid was about 166, 300, and 466 mV, respectively. So, this graphene-modified electrode can be used for simultaneous determination of each component in a mixture.  相似文献   

16.
Gold nanotubule membranes were prepared by using electroless deposition of gold within the pores and surfaces of polycarbonate track-etched membranes.And the gold nanotubule membrane was used as an electrode for determination of uric acid in urine samples for the first time.In Britton-Robinson buffer of pH 4.56,uric acid exhibited well-defined differential pulse voltammograms.And the interference between coexistent ascorbic acid and uric acid was overcome owing to the attractive ability of the gold nanotubule electrode to yield a large anodic peak difference ca.0.404 V(vs.SCE).The proposed method was then applied to the determination of uric acid in urine without any pretreatment.  相似文献   

17.
A sensitive electroanalytical methodology for the determination of uric acid in real samples using adsorptive voltammetry at a multiwalled carbon nanotubes (MWCNT) modified screen printed electrode (SPCE) is presented. Adsorption of uric acid takes place at open circuit potential at an optimized pH 5.0. Studies about the effect of accumulation time and scan rate on the analytical signal were developed and confirm the adsorption nature of the electrodic process. Quantitative analysis of uric acid by using its oxidation process at +0.18 V (vs. an Ag pseudoreference electrode) was carried out with an accumulation time of 5 min. Thus, a linear voltammetric based reproducible determination of uric acid (RSD 5 %) in the range 1–100 µM was obtained. The method was then successfully used for the determination of uric acid in real clinical samples of urine without detection of interferences. The proposed methodology only requires a dilution of the real sample and present advantages as low cost and easy handling for non specialized technicians.  相似文献   

18.
以柠檬酸三钠为碳源,采用微波辅助制备碳点,用β-环糊精(β-CD)和碳点复合制备出碳点/β-CD复合物,并用荧光、紫外、红外光谱等进行表征.在pH=6.6的磷酸盐缓冲溶液中,尿酸可使碳点/β-CD复合物的荧光增强,探讨了反应时间、反应温度、缓冲溶液及pH对荧光增强程度的影响,建立了测定尿样中尿酸含量的方法.碳点/β-C...  相似文献   

19.
A double-stranded (ds) DNA-octadecylamine Langmuir–Blodgett film was attached to the surface of glassy carbon electrode (GCE) to create a novel voltammetric sensor (DNA-LB/GCE) for epinephrine (EP). Atomic force microscopy and electrochemical impedance spectroscopy were employed to study the characteristic of the DNA-LB film. The electrochemical behavior of EP at the modified electrode was investigated in pH 6.0 phosphate buffer solutions by cyclic voltammetry and amperometric methods. Compared with bare GCE, the DNA-LB/GCE sensor demonstrated an electrocatalytic effect on the oxidation of EP. In addition, the sensor shows excellent selectivity for EP detection, being free of interference from excess ascorbic acid and uric acid, and the method was also applied successfully to detect EP in the human urine samples.  相似文献   

20.
Jen JF  Hsiao SL  Liu KH 《Talanta》2002,58(4):711-717
A simple, rapid, and eco-friendly analytical method for simultaneous determination of uric acid and creatinine in urine applying high performance liquid chromatography (HPLC) is described. After dilution, de-protein, and filtration, the sample solution was injected to separate the species with C-18 column by an eluent containing 0.05 M ammonium phosphate buffer at pH 7.4. An UV detector was used to monitor the separation of species at 235 nm. Optimum conditions for separation and detection were investigated. Results indicated that under optimized condition measurements were achieved within 13 min. The detection limits were 0.127 and 0.156 mug ml(-1) for uric acid and creatinine respectively. The recovery was 95% (0.57% RSD) for uric acid and 99.2% (0.98% RSD) for creatinine, from five measurements. Real urine specimens were tested.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号