1.
The capillary electrochromatographic separations of three acidic enantiomers (carprofen, coumachlor and warfarin) were studied on a capillary column packed with 5 microm (3R,4S)-Whelk-O 1 chiral stationary phase. The influence of several experimental parameters (mobile phase pH, type of background electrolyte, acetonitrile ratio, temperature, applied voltage and ionic strength) on electroosmotic flow velocity, retention factor, selectivity factor, efficiency, resolution and effectiveness of chiral separation was evaluated. It was notable that the optimum resolution of the acidic enantiomers was achieved at pH 3.0 phosphate buffer, suggesting that capillary electrochromatography in the ion-suppressed mode can be applied for chiral separations of a range of acidic compounds.  相似文献   

2.
The influence of temperature, T, on the retention times, peak widths, peak symmetry coefficients and theoretical plate numbers of two small linear peptides, [Met5]enkephalin and [Leu5]enkephalin, has been studied with capillary electrochromatography (CEC) capillary columns of 100 microm I.D. and 250 mm packed length with a total length of 335 mm, containing 3 microm Hypersil n-octadecyl bonded silica. With increasing column temperature from 15 to 60 degrees C, the electroosmotic flow (EOF) and the column efficiencies increased, whereas the retention coefficients (Kcec) of both peptides decreased. A linear relationship was found between the EOF value and the square root of the temperature over this temperature range, with a linear regression correlation of 0.998. Non linear Van 't Hoff plots (In Kcec versus 1/T) were observed for these peptides between 15 and 60 degrees C, suggesting that a phase-transition occurred with the n-octadecyl chains bonded on the silica surface, affecting the CEC retention behaviour of these peptides. In CEC systems, the Kcec values of peptides incorporate contributions from both electrophoretic migration and chromatographic retention. Positive and negative Kcec values can, in principle, thus arise with these charged analytes. However, the Kcec values of the enkephalin peptides under all temperature conditions studied were positive with an eluent composed of water-50 mM NH4OAc/AcOH, pH 5.2-acetonitrile (5:2:3, v/v) and therefore the chromatographic component dominates the retention process with these small peptides under these conditions.  相似文献   

3.
The effects of some experimental parameters, such as the volume fraction and type of organic modifier in the mobile phase, and the concentration, type and pH of the buffer on the electroosmotic flow velocity, the retention behavior of test solutes, and the column efficiency have been investigated in capillary electrochromatography (CEC) using an open-tubular column of 9.60 microm I.D. with a porous silica layer chemically modified with C18 as stationary phase. The retention of a group of polycyclic aromatic hydrocarbons (PAHs) used as a test mixture varied significantly by changing the organic modifier content in the hydroorganic mobile phase according to the reversed-phase-like selectivity of the stationary phase. In addition, an increase in the percentage of organic modifier resulted in a slight increase in the linear velocity of the EOF. On the other hand, when the phosphate buffer concentration was increased over the range 1-50 mM, the electroosmotic mobility fell dramatically, the retention of the solutes decreased steadily, and the plate height showed a significant increase. The results obtained with phosphate, trishydroxymethylaminomethane or 2-morpholinoethanesulfonic acid as buffers were similar when pH remained constant. Optimization in CEC was essential to achieve further enhancement of separation performance, because the analysis time and separation resolution are essentially affected when varying operating parameters. Separations of seven PAHs with more than 100000 plates are presented within 4 min analysis time.  相似文献   

4.
The reproducibility of two migration parameters (retention time and mobility) of a seven-component test mixture was examined under various operating conditions using laboratory-built capillary electrophoresis systems. It was found that the frequency of rinsing the capillary and the solutions used for rinsing had the greatest effect on migration reproducibility. In addition, it was found that the migration behavior of solutes that interact with micelles is not repeatable unless the proper rinse protocol is applied. Inconsistent migration behavior is linked to inconsistent total current of the system. Preliminary investigations indicate that the fluctuation in total current were associated with non-equilibrium conditions between the buffer and the capillary wall.  相似文献   

5.
The influence of Joule heating on electroosmotic flow velocity, the retention factor of neutral analytes, and separation efficiency in capillary electrochromatography was investigated theoretically and experimentally. A plot of electrical current against the applied electrical field strength was used to evaluate the Joule heating effect. When the mobile phase concentration of Tris buffer exceeded 5.0 mM in the studied capillary electrochromatography systems using particulate and monolithic columns (with an accompanying power level of heat dissipation higher than 0.35 W/m), the Joule heating effect became clearly noticeable. Theoretical models for describing the variation of electroosmotic flow velocity with increasing applied field strength and the change of retention factors for neutral analytes with electrical field strength at higher Tris buffer concentrations were analyzed to explain consequences of Joule heating in capillary electrochromatography. Qualitative agreement between experimental data and implications of the theoretical model analysis was observed. The decrease of separation efficiency in capillary electrochromatography with macroporous octadecylsilica particles at high buffer concentration can be also attributed to Joule heating mainly via the increased axial diffusion of the analyte molecules and dispersion of solute bands by a nonuniform electroosmotic flow profile over the column cross-section. However, within a moderate temperature range, the contribution of the macroscopic velocity profile in the column arising from radial temperature gradients is insignificant.  相似文献   

6.
Capillary electrochromatography (CEC) requires stationary phases that enable appropriate electroosmotic propel under various conditions. Analyte retention can be controlled through hydrophobic or electrostatic interaction with the packing material. The development and characterization of new strong anion-exchange materials with additional hydrophobic moieties (SAX/C18 mixed-mode phases) is described. The synthesis was based on polymer encapsulation of porous silica. The phases were systematically characterized by means of elemental analyses, HPLC frontal analyses and CEC experiments. The studies focused on the influence of various parameters (e.g., pH, kind of buffer, capillary wall) on the electroosmotic flow (EOF). Phases with high anion-exchange capacity generated a fast and constant EOF over a wide pH range. Long-time stability of EOF and hydrophobic retention under CEC conditions were demonstrated within the course of 100 consecutive injections. The applicability of the SAX/C18 phases in appropriate buffer systems is demonstrated for neutral, acidic and basic compounds.  相似文献   

7.
The aim of this study was to evaluate the applicability of ODS-AQ packing material as a stationary phase in capillary electrochromatography (CEC). The electroosmotic flow created on an ODS-AQ stationary phase was measured at different mobile phase compositions and at different column temperatures. It was observed that the electroosmotic flow generated in the column increased by 50% when the temperature of the system was raised from 20 degrees C to 60 degrees C, while all other conditions were kept constant. The electroosmotic flow produced by the ODS-AQ stationary phase was found to be comparable to the flow generated in a column packed with Nucleosil bare-silica material. In addition, a set of polar compounds (D-lysergic acid diethylamide derivatives) was utilized to determine the influence of temperature and mobile phase composition on their chromatographic behavior on an ODS-AQ stationary phase in a CEC mode. A linear relationship between the solute retention factor and column temperatures was seen over the temperature range studied (20 degrees C to 60 degrees C). A quadratic function was used to describe the changes in the solute retention factors with variation of acetonitrile concentration in the mobile phase.  相似文献   

8.
Characteristics of electroosmotic flow (EOF) and the migration of neutral solutes under double stepwise gradient elution in capillary electrochromatography were studied systematically. EOF velocity proved to be the function of operation time changing with the introduction of the second mobile phase. Accordingly, the retention of components also changed. The migration of neutral solutes was studied under the following three situations; A, components eluted when the column was filled only with the first kind of mobile phase; B, solutes eluted still in the first kind of mobile phase while at that time two kinds of mobile phase coexisted in the column and C, samples eluted in the second kind of mobile phase. Equations to describe the retention times of components under these three kinds of conditions were deduced and applied to predict the retention times of 12 aromatic compounds. Relative errors between experimental and calculated values were below 5.0%, which proved the reliability of the equations. In addition, parameters that might affect the retention time of solutes, such as the transferring time of mobile phase vials, the capacity factors of components and EOF velocities two steps were studied systematically.  相似文献   

9.
The separation mechanism in capillary electrochromatography (CEC) is a hybrid differential migration process, which entails the features of both high-performance liquid chromatography (HPLC) and capillary zone electrophoresis (CZE), i.e., chromatographic retention and electrophoretic migration. The focus of this paper is on the use of electrokinetic data, such as current, electroosmotic flow (EOF) and column efficiency measurements, that are readily available, for an improved understanding of CEC separations. A framework is presented here for the use of this data for evaluation of a variety of performance parameters including, conductivity ratio, interstitial EOF mobility, porosity, and zeta potential. This framework is applied for characterization of two monolithic columns with different chemistry that were manufactured in-house. The above-mentioned performance parameters were calculated for the two columns and it is found that the poly(VBC-EGDMA-SWNT) monolithic column with the GPTMS-PEI coating offers a significantly improved flow distribution in comparison to the poly(VBC-EGDMA) monolithic column. This observation is confirmed by performing separation of peptides on the two columns and height equivalent of a theoretical plate (HETP) measurements on the resulting peaks. It is shown that following our approach leads to an improved understanding of the separations achieved with the columns and to better column design.  相似文献   

10.
A hydrophilic polymer, poly(vinylpyrrolidone) (PVP), was employed for suppressing the electroosmotic flow (EOF). A capillary was filled with aqueous PVP solution for coating the capillary wall with PVP; the PVP solution was then replaced by a migration buffer solution containing no PVP. Three types of PVP with different molecular weights were examined. The EOF was suppressed more effectively as the molecular weight of PVP increased. The EOF in the coated capillary was approximately 10-fold smaller than that of a bare capillary and was constant in the pH range of 6-8. The suppressed EOF was stable even when no PVP was added to the migration buffer. However, the EOF increased significantly when sodium dodecyl sulfate was added into the migration buffer. The method was applied for determining the electrophoretic mobilities of inorganic anions that have negative electrophoretic mobilities larger than the electroosmotic mobility of the bare capillary. A novel method for determining the electrophoretic mobilities was proposed based on the linear relationship between electric current and electrophoretic mobility. The electrophoretic mobility was proportional to the electric current. Therefore, the intercept of the regression equation represents the electrophoretic mobility at room temperature. The electrophoretic mobilities were in good agreement with the absolute electrophoretic mobilities.  相似文献   

11.
Fujimoto C 《Electrophoresis》2002,23(17):2929-2937
The potential of titanium dioxide coatings to control the electroosmotic flow and to affect the migration behavior of analytes in capillary electrophoresis and open-tubular capillary electrochromatography was evaluated. The inner wall of a fused-silica capillary was applied with a solution of a titanium peroxo complex, followed by heating at an elevated temperature. The resultant product was ascertained to be titanium dioxide in a crystalline form of anatase by the results of Fourier transform-infrared spectrometry (FT-IR), X-ray photoelectron spectroscopy, and Raman spectroscopy. The capillary thus made had anodic or cathodic electroosmotic flow, depending on the pH and composition of the background electrolyte used. The titanium dioxide surface of the capillary was readily modified by a silanizing reagent. The performance of the titanium dioxide surfaces with or without chemical modifications was examined with inorganic anions, neutral compounds and peptides.  相似文献   

12.
In capillary electrochromatography (CEC) the propulsion of the mobile phase is effected by electroosmosis. The velocity of the electroosmotic flow is dependent on surface properties of the stationary phase and on bulk properties of the mobile phase. Therefore, in CEC the optimization of the mobile phase composition must take more factors into account than in pressure-driven LC. In this paper, the impact of the electrolyte concentration in the mobile phase and of the volume fraction of the organic mobile phase constituent on the velocity of the electroosmotic flow and on the chromatographic efficiency is investigated for CEC with capillaries packed with octadecylsilica gel. Bias of the data by an open section of the capillary has been excluded by employing completely packed capillaries and detection in a packed section. Acetonitrile as organic constituent of the mobile phase is compared to other possible organic modifiers (polar organic solvents) concerning influence on velocity of the electroosmotic flow and retention of solutes.  相似文献   

13.
Maichel B  Kenndler E 《Electrophoresis》2000,21(15):3160-3173
Recent developments of separation of neutral analytes in capillary systems with the mobile phase driven by the electroosmotic flow (EOF) and charged additives acting as a pseudostationary phase are reviewed. As pseudostationary phases a number of additives are used. Soluble polymers, either anionic or cationic, were applied as alternatives to micelles. Monomeric charged additives are also intended to form associates with the analytes, leading to selective retention and separation in a similar way as the polymeric pseudostationary phases. Dendrimers, spherical macromolecules with highly branched chains and charged terminal groups, are successfully applied for the separation of lipophilic analytes. Polymers with covalently stabilized structures are introduced in the form of permanent micelles and are therefore insensitive to the mobile phase composition, enlarging the applicability of micellar electrokinetic capillary chromatography (MEKC).  相似文献   

14.
To obtain reproducible migration times and rapid analyses of analytes, sulfonate groups were chemically introduced to the inner wall of untreated fused-silica capillary with 2-(4-chlorosulfonylphenyl)ethyltrichlorosilane. The sulfonated capillary showed relatively constant electroosmotic mobility which was greater than that obtained by an untreated fused-silica capillary over the pH range studied (pH 2-9). In both CZE and MEKC, the RSDs of the migration times of analytes with the sulfonated capillary were less than 0.2% which were significantly lower than those obtained with an untreated fused-silica capillary (0.5-3.5%). When BGE were set at pH 7.0 for CZE and MEKC, the analysis times with the sulfonated capillary were about half those obtained with an untreated fused-silica capillary. These results indicate that the sulfonated capillary can provide highly reproducible and rapid analyses in CE.  相似文献   

15.
A simple method to calculate dissociation constants for protein-ligand interactions by partial-filling capillary electrophoresis is demonstrated. The method uses raw migration time data for the ligand and needs only additional information about capillary inner radius and the absolute amount of protein loaded. A theoretical study supported by experimental data also demonstrates that the retention of analyte in affinity capillary electrophoresis (ACE) using the partial-filling technique depends linearly on the absolute amount of selector added but is independent of both selector zone length and selector mobility. Factors such as field strength and electroosmotic flow are also cancelled out if they are kept constant. The theory is confirmed and the usefulness of the method is demonstrated by enantioseparations using alpha-acid glycoprotein (AGP) and cellulase (Cel 7A) as chiral selectors.  相似文献   

16.
Cianciulli C  Wätzig H 《Electrophoresis》2011,32(12):1530-1536
In capillary electrophoresis (CE), the temperature inside the capillary is one of the most important parameters. In a concept for Analytical Instrument Qualification (AIQ) of CE systems, the temperature accuracy and stability have to be included. This fact requires an accurate look at the measurement of temperature which is generated by the applied electrical power. The generation of Joule heating is measured on the outside of the capillary using an infrared (IR) thermometer. The thermometer linearity is demonstrated over a wide range of various electrical field strength, buffer systems, and different capillary inner diameters. A slope of 6.3 °C m/W was found for the optimal thermometer capillary distance of 8 mm. Furthermore, the temperature measurements are highly precise, depending almost solely on the current variability. The proposed method is compared with three methods calculating the temperature from the conductance, the electroosmotic velocity, or the current. These indirect methods estimate slopes ranging from 7 to 10 °C m/W. In addition, the maximal suitable electrical power per unit length is estimated. Joule heating can often be tolerated up to 4 W/m. However, sensitive analytes can already be affected by using more than 1 W/m. In conclusion, the consideration of the temperature is essential for not only Analytical Instrument Qualification, but also certainly useful for method optimisation and method transfer.  相似文献   

17.
The determination of the velocities of the mobile and the pseudostationary phases (the migration (time) window) is mandatory for the determination of physicochemical properties by electrokinetic chromatography (EKC). This review offers a detailed discussion on the definition, the importance, the determination and the regulation of the migration (time) window in EKC. An overview on the theoretical treatment of chromatographic processes in EKC is given defining EKC in comparison to the term capillary electrophoresis. Methods to determine and influence the migration window are discussed with emphasis on measures that have been taken to modify the electroosmotic flow velocity. Pseudostationary phases (or separation carriers) that are taken into consideration are anionic and cationic micelles, mixed micelles, microdroplets (microemulsions), polymeric pseudostationary phases and dendrimers.  相似文献   

18.
A background electrolyte for capillary electrophoresis containing tris(-hydroxymethyl) aminomethane (THAM) and ethanesulfonic acid (ESA) gives excellent efficiency for separation of drug cations with actual theoretical plate numbers as high as 300,000. However, the analyte cations often elute too quickly and consequently offer only a narrow window for separation. The best way to correct this is to induce a reverse electroosmotic flow (EOF) that will spread out the peaks by slowing their migration rates, but this has always been difficult to accomplish in a controlled manner. A new method for producing a variable EOF is described in which a low variable concentration of tributylammonium- or triethylammonium ESA is added to the BGE. The additive equilibrates with the capillary wall to give it a positive charge and thereby produce a controlled opposing EOF. Excellent separations of complex drug mixtures were obtained by this method.  相似文献   

19.
Xuan X  Li D 《Electrophoresis》2005,26(1):166-175
It is widely accepted that Joule heating effects yield radial temperature gradients in capillary zone electrophoresis (CZE). The resultant parabolic profile of electrophoretic velocity of analyte molecules is believed to increase the band-broadening via Taylor-Aris dispersion. This typically insignificant contribution, however, cannot explain the decrease in separation efficiency at high electric fields. We show that the additional band-broadening due to axial temperature gradients may provide the answer. These axial temperature variations result from the change of heat transfer condition along the capillary, which is often present in CZE with thermostating. In this case, the electric field becomes nonuniform due to the temperature dependence of fluid conductivity, and hence the induced pressure gradient is brought about to meet the mass continuity. This modification of the electroosmotic flow pattern can cause significant band-broadening. An analytical model is developed to predict the band-broadening in CZE with axial temperature gradients in terms of the theoretical plate height. We find that the resultant thermal plate height can be very high and even comparable to that due to molecular diffusion. This thermal plate height is much higher than that due to radial temperature gradients alone. The analytical model explains successfully the phenomena observed in previous experiments.  相似文献   

20.
When field-enhanced sample stacking was used in capillary zone electrophoresis (CZE) analysis of cations, the decrease of migration time and the reduction of separation window was observed with increase of sample plug length. A simple equation expressing the migration velocity in the stacking process was derived to explain the above phenomenon. From experiments and theoretical consideration, we confirmed that this effect was caused by the higher potential gradient and larger eletroosmotic flow (EOF) mobility at the sample plug than those at the supporting electrolyte. A mathematical model appropriate for the computer simulation of such a system was studied considering the experimental results, and it was concluded that electroosmotic velocity (v(eof)) should be introduced to the equation of continuity as a constant.  相似文献   