首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The morphology of porous silicon (PS) layers produced by electrochemical etching of n-type (100) silicon (Si) at different low current densities was studied using SEM, image J analysis and WSxM software. From FTIR spectroscopy analysis, the Si dangling bonds of the as-prepared PS layer have large amount of Hydrogen to form weak Si–H bonds. From Raman analysis, a full width half maximum (FWHM) of the Raman peak was gradually increased with increased current density, shifted towards lower energies due to reduce of crystallite size, the crystallite size in the PS varied from 63 nm to 20 nm depending on the current density. The optical response of the PS layer has been performed by the absorbance and Photoluminescence was studied experimentally in the visible range. The optical absorption and photo luminescence in PS is due to excitonic recombination between the defect states as well as on the surface of nanocrystals, and this was attributed to the presence of silicon hydride species which are confirmed by FTIR spectra. The red shift was observed in absorbance and Photoluminescence due to decrease in the size of Si crystallites and growth of Si=O bonds. The contact angle varied from 76° to 120.1°. From the wettability studies, the surface nature of the PS was converted from hydrophilic to hydrophobic when the current density increased.  相似文献   

2.
Electrochemically etched porous silicon (PSi) is formed and employed as a substrate for the entrapment of oligonucleotides and the subsequent development of stable DNA biosensors. The controlled potential anodic etching of p‐type silicon wafers is optimized in order to obtain a surface layer with pore diameters which are close to those of the adsorbed DNA helix. The stabilization and hybridization of DNA inside the PSi layer is confirmed using ATR‐FTIR. Moreover hybridization is verified by the large and reproducible impedance changes at the interface layer. The developed PSi DNA sensor paves the way for the label‐free detection of oligonucleotide sequences in DNA microarrays and microfabricated PSi field‐effect sensors.  相似文献   

3.
Porous silicon and its luminescent properties are well known for more than a decade. The origin of the nanoporosity evolution, however, is still obscure. We address this topic by investigating the earliest detectable stages of silicon dissolution using atomic force microscopy and synchrotron radiation photoelectron spectroscopy. The electrolyte composition and the electrode potential are chosen as to resolve the dissolution, beginning from the submonolayer regime. We find extremely local formation of nanopits due to electrolyte countercharge immobilisation at specific surface sites of the ideally hydrogen terminated (1 1 1) surface. In conjunction with density functional theory calculations on dissolution reaction intermediates and photoelectron spectroscopy, an existing dissolution model is completed. The results have far reaching significance for the preparation of nanostructures, distinctly shaped despite their unequalled small dimensions.  相似文献   

4.
We have formed photoluminescent porous silicon (PS) layers and over which a ZnO layer (hereafter called ZnOPS layers) is deposited. We studied the photoluminescent properties of individual layers as well as the composite layer under excitation with 405 nm wavelength. Using the data of PL a theoretical analysis of a solar cell having such a composite layer of a given photoluminescent conversion efficiency ηPL on the front surface has been done. The condition of a photoluminescent composite layer (ZnOPS) useful for enhancing the spectral response of n+-p-p+ structured silicon solar cell has been identified.  相似文献   

5.
Capacitive alcohol gas sensors using a porous silicon (PS) layer were fabricated and investigated for the measurement of breath alcohol concentration. Since the PS layer shows high adsorption against ethanol along with a large internal surface area, detecting low alcohol gas concentrations without any heating may be realized in comparison with metal oxide sensors. In this work, we measured the capacitance for the range of 0–0.5% alcohol concentrations using the proposed sensors, and observed how illumination of UV light affected the sensitivity. In addition, the effect of CO2 and N2 gases involved commonly in exhaling breath was estimated, and the same experiment for methanol gas was executed to compare qualitatively with ethanol gas. Received: 23 July 1999 / Accepted: 15 October 1999  相似文献   

6.
Nanostructured porous silicon (PSi) is an attractive platform for the design of biosensors because of its high sensitivity and selectivity towards various biological targets. Its use for biosensing applications, however, is compromised as a result of interfacial interactions with biological molecules that may accumulate on their surfaces and degrade their performance. We describe a new hybrid system comprising an oxidized PSi (PSiO2) nanostructure and antifouling (anti‐adsorption), light‐triggered pre‐polymers that promote crosslinking and surface anchoring to Si walls. The incorporation of the pre‐polymers allowed the production of a thick hydrogel layer on the inorganic nanostructure. Coating completely prevents fouling of proteins on the surface without compromising biosensor performance in terms of sensitivity. The strategy developed here provides a convenient means to combine two distinct features of crosslinking and organic–inorganic hybrid fabrication in a “one‐pot” process. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

7.
This study introduces a new production method to use as a porous silicon-based proton exchange membrane for μDMFCs. In this respect, EIS, fuel crossover test, and fuel cell performance test at the μDMFC sample cell are performed at room temperature on a porous silicon-based membrane that was produced for passive mode μDMFC as a proton exchange membrane. The reason for performing the fuel crossover test is to ensure the silicon opened pores along the silicon wafer and to examine the fuel permeability of the membrane. The fuel crossover test shows that the fuel cell provides energy for about 60 min with a 50 mL fuel. EIS reveals proton permeability of proton exchange membrane. The calculated value of the conductivity of the membrane is 0.0016 S/cm. OCV of the system is 0.4V, whereas values (with highest power density is 0.1 mW/cm²and with the highest current density is 0.39 mA/cm²) are low. However, porous silicon is not a natural proton conductor. Hence, these values can be increased by different ways such as porous silicon functionalized, or serial connection of fuel cells. On the other hand, the value of OCV is consistent with the previous studies. In sum, this study presents a simple, cost-effective, and short time-consuming method for the production of porous silicon as proton-conducting membrane behavior.  相似文献   

8.
A visible rectification effect on the current-voltage curves of metal/porous silicon/p-silicon has been observed by current-sensing atomic force microscopy. The current-voltage curves of porous silicon membranes with different porosities, prepared through variation of etching current density for a constant time, indicate that a higher porosity results in a higher resistance and thus a lower rectification, until the current reaches a threshold at a porosity 〉55%. We propose that the conductance mode in the porous silicon membrane with porosities 〉55% is mainly a hopping mechanism between nano-crystallites and an inverse static electric field between the porous silicon and p-Si interface blocks the electron injection from porous silicon to p-Si, but with porosities ≤55%, electron flows through a direct continuous channel between nano-crystallites.  相似文献   

9.
In this work, porous silicon (PS) films with varied porosity (68–82%) were formed on the p-type, boron-doped silicon wafer (100) by the electrochemical anodisation in an aqueous hydrofluoric acid and isopropyl alcohol solution at different current densities (I d) ranging from 20–70 mA cm?2, respectively. Biofunctionalisation of the PS surface was carried out by chemically modifying the surface of PS by the deposition of 3-aminopropyltriethoxysilane thermally leading to high density of amine groups covering the PS surface. This further promotes the immobilisation of immunoglobulin (human IgG and goat anti-human IgG binding) on to the PS surface. Formation of nanostructured PS and the attachment of antibody–antigen to its surface were characterised using photoluminescence (PL), Fourier transform infrared spectroscopy and X-ray photoelectron spectroscopy techniques, respectively. The possibility of using these structures as biosensors has been explored based on the significant changes in the PL spectra before and after exposing the PS optical structures to biomolecules. These experimental results open the possibility of developing optical biosensors based on the variation of the PL position of the PL spectra of PS-based devices.  相似文献   

10.
Abstract

This work presents on improvement in gravimetric measurement for determining the porosity and thickness of microporous silicon. Herein, the corrosion of fresh macroporous silicon (f-MPSi) in 1.0?M NaOH with different concentrations of polyethylene glycol (PEG 200/400/600) was studied by weight loss measurement and scanning electron microscopy (SEM). The results showed that the corrosion rate decreased with increasing polyethylene glycol concentration, and increased with an increase in temperature. Polyethylene glycol can inhibit the corrosion of f-MPSi in NaOH solution. Moreover, 1.0?M NaOH/PEG 600 (10%) can be used as the optimized solution to remove f-MPSi for measuring its porosity and thickness by gravimetric measurement.  相似文献   

11.
Krioukov E  Klunder D  Driessen A  Greve J  Otto C 《Talanta》2005,65(5):1086-1090
Application of an integrated optics (IO) microcavity (MC) for evanescent excitation of two-photon excited fluorescence (TPF) is demonstrated. The MC provides a high local intensity, which is required for the TPF, because of resonant enhancement of the intracavity power and a strong two-dimensional confinement of the guided mode. Numerical estimations show a large increase, by more than a factor of 104 of the TPF intensity at the MC compared to a conventional straight waveguide. This will lead to a significant improvement of the detection limits of UV-absorbing chromophores (down to 10−8 M) when using the MC as a biosensor. Feasibility of TPF excitation using an IO MC is confirmed experimentally for the first time.  相似文献   

12.
Short single-stranded DNA (ssDNA) oligonucleotides can be grown on the surface of fused silica by automated nucleic acid synthesis. The immobilized ssDNA can be deposited at a desired average density. The density of ssDNA provides a controlled parameter that in combination with temperature, ionic strength and pH, can be used to define the selectivity of hybridization. Furthermore, the density of ssDNA can be used to control the affinity of complementary DNA so that it associates with the nucleic acids on the surface rather than areas that are not coated with ssDNA. The characteristic melt temperature observed for immobilized double-stranded DNA (dsDNA) 20mer shifts by up to 10 °C when a single base pair mismatch is present in the center of a target oligonucleotide. Optimization of quantitative analysis of such single base pair mismatches requires use of select experimental conditions to maximize the formation of the fully matched target duplex while minimizing the formation of the mismatched duplex. Results based on fiber optic biosensors that are used to study binding of fluorescein-labeled complementary DNA demonstrate that it is possible to achieve a selectivity coefficient of fully matched to single base pair mismatch of approximately 85-1, while maintaining >55% of the maximum possible signal that can be obtained from the fully matched target duplex.  相似文献   

13.
Enriching the surface density of immobilized capture antibodies enhances the detection signal of antibody sandwich microarrays. In this study, we improved the detection sensitivity of our previously developed P-Si (porous silicon) antibody microarray by optimizing concentrations of the capturing antibody. We investigated immunoassays using a P-Si microarray at three different capture antibody (PSA – prostate specific antigen) concentrations, analyzing the influence of the antibody density on the assay detection sensitivity. The LOD (limit of detection) for PSA was 2.5 ng mL−1, 80 pg mL−1, and 800 fg mL−1 when arraying the PSA antibody, H117 at the concentration 15 μg mL−1, 35 μg mL−1, and 154 μg mL−1, respectively. We further investigated PSA spiked into human female serum in the range of 800 fg mL−1 to 500 ng mL−1. The microarray showed a LOD of 800 fg mL−1 and a dynamic range of 800 fg mL−1 to 80 ng mL−1 in serum spiked samples.  相似文献   

14.
An ammonia gas sensor chip was prepared by coating an electrochemically-etched porous Si rugate filter with a chitosan film that is crosslinked by glycidoxypropyltrimethoxysilane (GPTMS). The bromothylmol blue (BTB), a pH indicator, was loaded in the film as ammonia-sensing molecules. White light reflected from the porous Si has a narrow bandwidth spectrum with a peak at 610 nm. Monitoring reflective optical intensity at the peak position allows for direct, real-time observation of changes in the concentration of ammonia gas in air samples. The reflective optical intensity decreased linearly with increasing concentrations of ammonia gas over the range of 0–100 ppm. The lowest detection limit was 0.5 ppm for ammonia gas. At optimum conditions, the full response time of the ammonia gas sensor was less than 15 s. The sensor chip also exhibited a good long-term stability over 1 year. Therefore, the simple sensor design has potential application in miniaturized optical measurement for online ammonia gas detection.  相似文献   

15.
A set of permethylated 6I-(ω-alkenoyl)-6I-amino-6I-deoxy-β-cyclodextrin derivatives with different chain length of the alkenoyl group (used as a spacer) was synthesized. These derivatives were attached by photochemically activated hydrosilylation reaction to the surface of porous silicon. Photoluminescence response of the modified PS to controlled concentrations of various molecules in gas phase revealed strong host-guest interactions between β-cyclodextrin and the detected molecules. The strongest interaction was observed for aromatic molecules, which have the optimal size to fit into the β-cyclodextrin molecular cavity.  相似文献   

16.
A novel aptamer biosensor for cancer cell assay has been reported on the basis of ultrasensitive electrochemical detection. The assay uses the aptamer as a capture probe to recognize and bind the tumor marker on the surface of the cancer cells, forming an aptamer-based sandwich structure for MCF-7 cells detection. Functionalized nanoporous materials, porous graphene oxide/Au composites (GO/Au composites) and porous PtFe alloy have been introduced into the biosensor. Owing to the large surface area and versatile porous structure, the use of nanoporous materials can significantly improve the analysis performance of the biosensors by loading of large amounts of molecules and accelerating diffusion rate. Under the optimized experimental conditions, the proposed aptamer biosensor exhibited excellent analytical performance for MCF-7 cells determination, ranging from 100 to 5.0 × 107 cells mL−1 with the detection limit of 38 cells mL−1. The biosensor showed good selectivity, acceptable stability and reproducibility, and developed a highly sensitive and selective method for cancer cells detection.  相似文献   

17.
Meng Du 《Talanta》2010,81(3):1022-25
This paper described a novel electrochemical DNA biosensor for rapid specific detection of nucleic acids based on the sulfonated polyaniline (SPAN) nanofibre and cysteamine-capped gold nanoparticle (CA-GNP) layer-by-layer films. A precursor film of 3-mercaptopropionic acid (MPA) was firstly self-assembled on the Au electrode surface. CA-GNP was covalently deposited on the Au/MPA electrode to obtain a stable substrate. SPAN nanofibre and CA-GNP were alternately layer-by-layer assembled on the stable substrate by electrostatic force. Cyclic voltammetry was used to monitor the consecutive growth of the multilayer films by utilizing [Fe(CN)6]3−/4− as the redox indicator. The (CA-GNP/SPAN)n films showed satisfactory ability of electron transfer and excellent redox activity in neutral media. Negatively charged probe ssDNA was immobilized on the outer layer of the multilayer film (CA-GNP) through electrostatic affinity. Chronopotentiometry and electrochemical impedance spectroscopy were employed to obtain the direct electrochemical readout for probe ssDNA immobilization and hybridization using [Fe(CN)6]3−/4− in solution as the mediator. While electrochemical impedance spectroscopy led to the characterization of the electron-transfer resistance at the electrode, chronopotentiometry provided the total resistance at the interfaces of the modified electrodes. A good correlation between the total electrode resistances and the electron-transfer resistances at the conducting supports was found. Chronopotentiometry was suggested as a rapid transduction means (a few seconds). Based on the (CA-GNP/SPAN)n films, the target DNA with 20-base could be detected up to 2.13 × 10−13 mol/L, and the feasibility for the detection of base-mismatched DNA was also demonstrated.  相似文献   

18.
19.
Structural DNA nanotechnology, an emerging technique that utilizes the nucleic acid molecule as generic polymer to programmably assemble well-defined and nano-sized architectures, holds great promise for new material synthesis and constructing functional nanodevices for different purposes. In the past three decades, rapid development of this technique has enabled the syntheses of hundreds and thousands of DNA nanostructures with various morphologies at different scales and dimensions. Among them, discrete three-dimensional (3D) DNA nanostructures not only represent the most advances in new material design, but also can serve as an excellent platform for many important applications. With precise spatial addressability and capability of arbitrary control over size, shape, and function, these nanostructures have drawn particular interests to scientists in different research fields. In this review article, we will briefly summarize the development regarding the synthesis of discrete DNA 3D nanostructures with various size, shape, geometry, and topology, including our previous work and recent progress by other groups. In detail, three methods majorly used to synthesize the DNA 3D objects will be introduced accordingly. Additionally, the principle, design rule, as well as pros and cons of each method will be highlighted. As functions of these discrete 3D nanostructures have drawn great interests to researchers, we will further discuss their cutting-edge applications in different areas, ranging from novel material synthesis, new device fabrication, and biomedical applications, etc. Lastly, challenges and outlook of these promising nanostructures will be given based on our point of view.  相似文献   

20.
In this article, we investigated the sequence specific interaction of single (ssDNA) and double stranded (dsDNA) with silver ions (Ag+) with electrochemical methods. We, for the first time, examined the effect of base sequences, base content and physiochemical properties of different DNA sequences on interaction with Ag+ in detail. We used different base contents to show how the composition of nucleic acid influences the electrochemical signals. We first immobilized ssDNA probes on bare graphite electrodes. Then, we showed the sequence effect on oxidation signals of AgDNA complex by sensing Ag+ to the probe coated surfaces to interact with different ssDNA sequences. Furthermore, we investigated the effect of Ag+ on dsDNA. We measured the oxidation signals obtained from Ag+‐ssDNA and Ag+‐dsDNA complex at approximately 0.2 V and 1.0 V (vs Ag/AgCl), respectively with Differential Pulse Voltammetry (DPV). We showed that the oxidation signals of the AgDNA complex obtained from dsDNA‐modified electrodes is higher than the electrodes modified with ssDNA. More importantly, we showed that Ag+‐ssDNA and Ag+ ion‐dsDNA exhibit different electrochemical behaviors.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号