首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The presence of trace metals in car fuels plays an important role in the engine maintenance. In addition, these metals contribute for the environmental contamination in big cities and their control is necessary. Square Wave Stripping Voltammetry (SWSV) is a very sensitive technique for elemental trace determination and was applied for ethanol fuel analysis. The first studies were done searching for the best conditions for copper determination in alcoholic medium, utilizing gold electrodes. During these studies, the possibility of the simultaneous determination of copper and lead in the same experiment was observed. Two procedures for the analysis of these metals were adopted: The direct quantification of metals in alcohol–water mixtures and a second way that involves the evaporation of the organic solvent and re-suspension of the ions with water+electrolyte. Good recovery values were obtained for synthetic samples spiked with known amounts of metals. The results obtained for the two methods were in good agreement. The detection limits for copper and lead in 75% ethanol–water ratio solution were calculated as 120 and 235 ng l−1, respectively, for 15-min deposition time.  相似文献   

2.
This work is an investigation into the utility of bismuth-film electrodes (BiFEs) for the determination of indium in the presence of cadmium and lead by square wave anodic stripping voltammetry (SWASV). The purpose of this study was to demonstrate that, after judicious choice of the associated chemical and instrumental conditions, it is possible to achieve satisfactory separation of the relevant stripping peak and, thus, to determine simultaneously trace concentrations of cadmium, lead and indium. It was conclusively demonstrated that a BiFE performed better than the equivalent mercury-film electrode (MFE) in this particular application.  相似文献   

3.
V. Meucci  S. Laschi  C. Pretti  G. Soldani 《Talanta》2009,77(3):1143-674
An optimized digestion method coupled to electrochemical detection to monitor lead, copper, cadmium and mercury in fish tissues was developed. Square wave anodic stripping voltammetry (SWASV) coupled to disposable screen-printed electrodes (SPEs) was employed as fast and sensitive electroanalytical method for heavy metals detection. Different approaches in digestion protocols were assessed. The study was focused on Atlantic hake fillets because of their wide diffusion in the human nutrition. Best results were obtained by digesting fish tissue with hydrogen peroxide/hydrochloric acid mixture coupled to solid phase (SP) purification of the digested material. This combined treatment allowed quantitative extraction from fish tissue (muscle) of the target analytes, with fast execution times, high sensitivity and avoiding organic residues eventually affecting electrochemical measurements. Finally, the method has been validated with reference standard materials such as dogfish muscle (DORM-2) and mussel tissues (NIST 2977).  相似文献   

4.
Sensitive and stable monitoring of heavy metals in seawater using screen-printed electrodes (SPE) is presented. The analytical performance of SPE coupled with square wave anodic stripping voltammetry (SWASV) for the simultaneous determination of Pb and Cd in seawater samples, in the low μg L−1 range, is evaluated. The stripping response for the heavy metals following 2 min deposition was linear over the concentration range examined (10-2000 μg L−1) with detection limits of 1.8 and 2.9 μg L−1 for Pb and Cd, respectively. The accuracy of the method was validated by analyzing metal contents in different spiked seawater samples and comparing these results to those obtained with the well-established anodic stripping voltammetry using the hanging mercury drop electrode. Moreover, a certified reference material was also used and the results obtained were satisfactory.  相似文献   

5.
Shams E  Abdollahi H  Yekehtaz M  Hajian R 《Talanta》2004,63(2):359-364
The applicability of H-point standard addition method (HPSAM) to the resolving of overlapping differential pulse anodic stripping voltammetric peaks corresponding to the oxidation of lead and tin is verified. The results show that the H-point standard addition method is suitable for the simultaneous determination of lead and tin in aqueous media. The results of applying the H-point standard addition method showed that Sn2+ and Pb2+ could be determined simultaneously with the concentration ratios of Sn2+ to Pb2+ varying from 1:5 to 10:1 in the mixed sample. The proposed method has been successfully applied to the simultaneous determination of lead in the presence of tin in some synthetic samples. Moreover, the applicability of the method was demonstrated by the recovery of lead in a canned soft drink sample.  相似文献   

6.
In the anodic stripping voltammetric speciation of copper significant errors may be introduced as a result of sorption of Cu2+ onto active surfaces of the voltammetric cell assembly. A correction method was developed based on monitoring of the total copper concentration in solution using a -radiotracer; additionally this allowed us to study sorption phenomena in the voltammetric cell assembly.For copper speciation in a fresh water sorption-corrected complexing capacity data (total natural ligand concentration and conditional stability constant of formed complex) showed considerable discrepancies with uncorrected data. From the same sorption data it could be deducted that this was accountable to the presence of two active surface sites in the voltammetric cell assembly.  相似文献   

7.
The concentration of trace metals in vegetable oils is an important criterion for the assessment of oil qualities with regard to freshness, keeping properties, storage and their influence on human nutrition and health. In this work, an effective and simple method for the determination of copper and lead in palm oil by stripping chronopotentiometry (SCP) is proposed. The metal ions were concentrated as their amalgams on the glassy carbon surface of a working electrode that was coated with a thin mercury film. An ultrasonic bath was used for the extraction of copper and lead from eleven oil samples using a 1:1 (v/v) mixture of concentrated hydrochloric acid and hydrogen peroxide. Efficient extraction of copper and lead (∼ 100%) was attained after 60 min of ultrasonic pre-treatment. A good correlation between the amount of sample and the time necessary for complete liberation of the metals was observed. The accuracy of the method was evaluated by means of a reference sample of skim milk powder containing trace elements (BCR 151). Quantitative analysis was carried out by the method of standard additions. Good linearity was obtained in the range of the concentrations examined. Detection limits of 13 and 50 ng g− 1 were found for Cu and Pb, respectively, in the palm oil samples. The average values found for the palm oil samples analyzed were in the range of < 0.013-2.67 µg g− 1 for copper and < 0.050-1.82 µg g− 1 for lead. The palm oil samples were also analyzed by graphite furnace atomic absorption spectrometry (GFAAS), demonstrating a very good correlation between the results.  相似文献   

8.
Carbon and gold microdisc electrodes (30 and 10 μm, respectively) have been tested as substrates for in situ bismuth film plating from unstirred solutions of variable acetate buffer content and were subsequently used in the anodic stripping voltammetry determination of Pb(II) and Cd(II) ions. The effects of Bi(III) concentration, analyte accumulation time, stirring as well as supporting electrolyte content have been studied. Under optimal conditions good voltammetric responses were obtained by means of square wave anodic stripping voltammetry in unstirred analyte solutions of 5 × 10−8 to 10−6 M, even in the absence of added buffer. In an indicative application, Pb(II) ion levels were determined in tap water using bismuth-plated carbon microdisc electrodes.  相似文献   

9.
The possibility of applying antimony-film modified glassy carbon electrode in sequential-injection analysis (SIA) was investigated with the objective of determining Pb(II) and Cd(II) by anodic stripping voltammetry (ASV). The conditions of antimony-film deposition concerning composition of the plating/carrier solutions, concentrations of Sb(III) and hydrochloric acid, effects of different supporting electrolyte salts, and plating potential were optimized. It was found that the antimony-film deposition on glassy carbon substrate in a sample solution consisting of 750 μg L−1 Sb(III), 0.5 mol L−1 HCl at −1.5 V (vs. Ag/AgCl/3 mol L−1 KCl) yielded a modified electrode suitable for the determination of Pb(II) and Cd(II) at the μg L−1 level. The reproducibility of the analytical signals was characterized by a relative standard deviation lower than 2.8%, and the calculated values of detection limits were 1.2 μg L−1 for Pb(II) and 1.4 μg L−1 for Cd(II). The presence of KSCN in the sample solution offers the possibility of detecting ions with more negative oxidation potentials like Zn(II), Mn(II) or Cr(III). The developed SIA-ASV procedure was compared with the commonly used batch method, and its applicability was tested on a spiked tap water sample.  相似文献   

10.
A sensitive and selective method for the simultaneous determination of copper, zinc and lead is presented. The method is based on the adsorptive accumulation of 2′,3,4′,5,7-pentahydroxyflavone (Morin) complexes of these elements onto a hanging mercury drop electrode, followed by reduction of adsorbed species by voltammetric scan using differential pulse modulation. Optimal analytical conditions were found to be Morin concentration of 2.0 μM, pH of 4.0, and an adsorption potential at −500 mV versus Ag/AgCl. With an accumulation time of 60 s, the peak currents are proportional to the concentration of copper, lead and zinc over the 1 to 60, 0.3-80 and 1-70 ng ml−1 range with detection limits of 0.06, 0.08 and 0.06 ng ml−1, respectively. The procedure was applied to the simultaneous determination of copper, lead and zinc in some real and synthetic artificial real samples with satisfactory results.  相似文献   

11.
This work addresses the simultaneous determination of copper(II) and antimony(III) in real matrices by differential pulse (DPASV) and fundamental harmonic alternating current anodic stripping voltammetry (ACASV). The voltammetric measurements were carried out using as supporting electrolyte the same acidic mixture (nitric, hydrochloric and perchloric acids) used in the dissolution of the real matrices with proper dilution. The procedure of the sample preparation is thus reduced to one step hence avoiding errors from long and complex sample handlings prior to the instrumental measurement. The results were verified by the analysis of the standard reference materials NBS-SRM 631 Spectrographic Zinc Spelter D-2 and BCS 207/2 Gunmetal. The precision, expressed as relative standard deviation, and the accuracy, expressed as relative error, were, in all cases, less than 5%; the detection limit, for each element and in the experimental conditions employed, was around 10−7 M. The standard addition technique improved the resolution of the voltammetric method, even in the case of very high metal concentration ratios.  相似文献   

12.
Jakmunee J  Junsomboon J 《Talanta》2008,77(1):172-175
An anodic stripping voltammetric method has been developed for determination of cadmium, lead, copper and zinc in acetic acid extract of glazed ceramic surfaces. An aliquot of 4% (v/v) acetic acid solution was kept in a ceramic ware for 24 h in the dark, then 10 mL of the extracted solution was placed in a voltammetric cell. The solution was purged with oxygen free nitrogen gas for 3 min before deposition of the metals was carried out by applying a constant potential of −1.20 V versus Ag/AgCl to the hanging mercury drop electrode (HMDE) for 45 s. A square wave waveform was scanned from −1.20 to 0.15 V and a voltammogram was recorded. A standard addition procedure was used for quantification. Detection limits of 0.25, 0.07, 2.7 and 0.5 μg L−1 for cadmium, lead copper and zinc, respectively, were obtained. Relative standard deviations for 11 replicate determinations of 100 μg L−1 each of all the metals were in the range of 2.8-3.6%. Percentage recoveries obtained by spiking 50 μg L−1 of each metal to the sample solution were in the range of 105-113%. The method was successfully applied to ceramic wares producing in Lampang province of Thailand. It was found that the contents of cadmium, lead, copper and zinc released from the samples were in the range of <0.01-0.16, 0.02-0.45, <0.14 and 0.28-10.36 μg dm−2, respectively, which are lower than the regulated values of the Thai industrial standard. The proposed method is simpler, more convenient and more sensitive than the standard method based on FAAS.  相似文献   

13.
Boron-doped nanocrystalline diamond thin-film electrodes were employed for the detection and quantification of Ag (I), Cu (II), Pb (II), Cd (II), and Zn (II) in several contaminated water samples using anodic stripping voltammetric (ASV). Diamond is an alternate electrode that possesses many of the same attributes as Hg and, therefore, appears to be a viable material for this electroanalytical measurement. The nanocrystalline form has been found to perform slightly better than the more conventional microcrystalline form of diamond in this application. Differential pulse voltammetry (DPASV) was used to detect these metal ions in lake water, well water, tap water, wastewater treatment sludge, and soil. The electrochemical results were compared with data from inductively coupled plasma mass spectrometric (ICP-MS) and or atomic absorption spectrometric (AAS) measurements of the same samples. Diamond is shown to function well in this electroanalytical application, providing a wide linear dynamic range, a low limit of quantitation, excellent response precision, and good response accuracy. For the analysis of Pb (II), bare diamond provided a response nearly identical to that obtained with a Hg-coated glassy carbon electrode.  相似文献   

14.
In the present work the anodic stripping voltammetric (ASV) methodology using a thin mercury film electrode in situ plated in thiocyanate media was re-assessed in order to allow the simultaneous determination of copper and lead in seawater. Under previously suggested conditions [6], i.e. using a concentration of thiocyanate of 5 mM, the ASV peaks of copper and lead overlapped due to the formation of a stable copper(I)-thiocyanate species, limiting the analytical determinations. Therefore, the best value for the thiocyanate concentration was re-evaluated: for 0.05 mM a trade-off between good resolution of the copper and lead peaks and high reproducibility of the mercury film formation/removing processes was achieved. In this media, the ASV peaks for Pb and Cu occurred, separated by 140 mV. Also, the in situ thin mercury film electrode was produced and removed with good repeatability, which was confirmed by the relative standard deviation values for the ASV determinations: 0.5% for Pb and 2.0% for Cu (10 replicate determinations in a solution with metal concentrations 1.5×10−8 M for lead and 2.2×10−8 M for copper). The optimised methodology was successfully applied to the determination of copper in the presence of lead, in certified seawater (NASS-5).  相似文献   

15.
A new automated batch method for the determination of ultratrace metals (nanogram per liter level) was developed and validated. Instrumental and chemical parameters affecting the performance of the method were carefully assessed and optimized. A wide range of voltammetric methods under different chemical conditions were tested. Cadmium, lead and copper were determined by anodic stripping voltammetry (ASV), while nickel, cobalt, rhodium and uranium by adsorptive cathodic stripping voltammetry (AdCSV). The figures of merit of all of these methods were determined: very good precision and accuracy were achieved, e.g. relative percentage standard deviation in the 4-13% for ASV and 2-5% for AdCSV.The stripping methods were applied to the determination of cadmium, lead, copper, nickel, cobalt, rhodium and uranium in lake water samples and the results were found to be comparable with ICP-MS data.  相似文献   

16.
This work reports the simultaneous determination of Cd(II), Pb(II) and Zn(II) at the low μg l−1 concentration levels by square wave anodic stripping voltammetry (SWASV) on a bismuth-film electrode (BFE) plated in situ. The metal ions and bismuth were simultaneously deposited by reduction at −1.4 V on a rotating glassy carbon disk electrode. Then, the preconcentrated metals were oxidised by scanning the potential of the electrode from −1.4 to 0 V using a square-wave waveform. The stripping current arising from the oxidation of each metal was related to the concentration of each metal in the sample. The parameters for the simultaneous determination of the three metals were investigated with the view to apply this type of voltammetric sensor to real samples containing low concentrations of metals. Using the selected conditions, the limits of detection were 0.2 μg l−1 for Cd and for Pb and 0.7 μg l−1 for Zn at a preconcentration time of 10 min. Finally, BFE's were successfully applied to the determination of Pb and Zn in tapwater and human hair and the results were in satisfactory statistical agreement with atomic absorption spectroscopy (AAS).  相似文献   

17.
Different procedures of voltammetric peak intensities determination, as well as various experimental setups were systematically tested on simulated and real experimental data in order to identify critical points in the determination of copper complexation parameters (ligand concentration and conditional stability constant) by anodic stripping voltammetry (ASV). Varieties of titration data sets (Cumeasuredvs. Cutotal) were fitted by models encompassing discrete sites distribution of one-class and two-class of binding ligands (by PROSECE software). Examination of different procedures for peak intensities determination applied on voltammograms with known preset values revealed that tangent fit (TF) routine should be avoided, as for both simulated and experimental titration data it produced an additional class of strong ligand (actually not present). Peak intensities determination by fitting of the whole voltammogram was found to be the most appropriate, as it provided most reliable complexation parameters.Tests performed on real seawater samples under different experimental conditions revealed that in addition to importance of proper peak intensities determination, an accumulation time (control of the sensitivity) and an equilibration time needed for complete complexation of added copper during titration (control of complexation kinetics) are the keypoints to obtain reliable results free of artefacts.The consequence of overestimation and underestimation of complexing parameters is supported and illustrated by the example of free copper concentrations (the most bioavailable/toxic specie) calculated for all studied cases. Errors up to 80% of underestimation of free copper concentration and almost two orders of magnitude overestimation of conditional stability constant were registered for the simulated case with two ligands.  相似文献   

18.
Flow injection (FI) and sequential injection (SI) systems with anodic stripping voltammetric detection have been exploited for simultaneous determination of some metals. A pre-plated mercury film on a glassy carbon disc electrode was used as a working electrode in both systems. The same film can be repeatedly applied for at least 50 analysis cycles, thus reducing the mercury consumption and waste. A single line FI voltammetric system using an acetate buffer as a carrier and an electrolyte solution was employed. An injected standard/sample zone was mixed with the buffer in a mixing coil before entering a flow cell. Metal ions were deposited on the working electrode by applying a potential of −1.1 V vs Ag/AgCl reference electrode. The stripping was performed by anodically scanning potential of working electrode to +0.25 V, resulting a voltammogram. Effects of acetate buffer concentration, flow rate and sample volume were investigated. Under the selected condition, detection limits of 1 μg l−1 for Cd(II), 18 μg l−1 for Cu(II), 2 μg l−1 for Pb(II) and 17 μg l−1 for Zn(II) with precisions of 2–5% (n=11) were obtained. The SI voltammetric system was similar to the FI system and using an acetate buffer as a carrier solution. The SI system was operated by a PC via in-house written software and employing an autotitrator as a syringe pump. Standard/sample was aspirated and the zone was then sent to a flow cell for measurement. Detection limits for Cd(II), Cu(II), Pb(II) and Zn(II) were 6, 3, 10 and 470 μg l−1, respectively. Applications to water samples were demonstrated. A homemade UV-digester was used for removing organic matters in the wastewater samples prior to analysis by the proposed voltammetric systems.  相似文献   

19.
The combined effects of pH, thiocyanate ion and deposition potential in the characteristics of thin mercury film electrodes plated on glassy carbon surfaces are evaluated. Charges of deposited mercury are used as an experimental parameter for the estimation of the effectiveness of the mercury deposition procedure. The sensitivity of the anodic stripping voltammetry (ASV) method for the determination of lead at in situ and at ex situ formed thin mercury films are also examined. It was concluded that, in acidic solutions (pH 2.5-5.7) and fairly negative deposition potentials, e.g. −1.3 to −1.5 V, thiocyanate ion promotes the formation of the mercury film, in respect both to the amount of deposited mercury and to the mercury deposition rate. Also, the mercury coatings produced in thiocyanate solutions are more homogeneous, as depicted by microscopic examinations. In the presence of thiocyanate there is no obvious advantage of using high concentrations of mercury and/or high deposition times for the in situ and ex situ preparation of the mercury film electrodes. The optimised thin mercury film electrode ex situ prepared in a 5.0 mM thiocyanate solution of pH 3.4 was successfully applied to the ASV determination of lead and copper in acidified seawater (pH 2). The limit of detection (3σ) was 6×10−11 M for lead and 2×10−10 M for copper for a deposition time of 5 min. Relative standard deviations (R.S.D.s) of <1.2% were obtained for determinations at the nanomolar of concentration level.  相似文献   

20.
A bismuth bulk electrode (BiBE) has been investigated as an alternative electrode for the anodic stripping voltammetric (ASV) analysis of Pb(II), Cd(II), and Zn(II). The BiBE, which is fabricated in-house, shows results comparable to those of similar analyses at other Bi-based electrodes. Metal accumulation is achieved by holding the electrode potential at −1.4 V (vs. Ag/AgCl) for 180 s followed by a square wave voltammetric stripping scan from −1.4 to −0.35 V. Calibration plots are obtained for all three metals, individually and simultaneously, in the10-100 μg L−1 range, with a detection limit of 93, 54, and 396 ng L−1 for Pb(II), Cd(II), Zn(II), respectively. A slight reduction in slope is observed for Cd(II) and Pb(II) when the three metals are calibrated simultaneously vs. individually. Comparing the sensitivities of the metals when calibrated individually vs. in a mixture reveals that Zn(II) is not affected by stripping in a mixture. However, Pb(II) and Cd(II) have decreasing sensitivities in a mixture. The optimized method has been successfully used to test contaminated river water by standard addition. The results demonstrate the ability of the BiBE as an alternative electrode material in heavy metal analysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号