首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A voltammetric procedure in the flow system for determination of traces of Cr(VI) in the presence of Cr(III) and humic acid is presented. The calibration graph is linear from 5×10−10 to 1×10−7 mol l−1 for an accumulation time of 120 s. The R.S.D. for 1×10−8 mol l−1 Cr(VI) is 5.3% (n=5). The detection limit estimated from 3σ for a low concentration of Cr(VI) and accumulation time of 120 s is 2×10−10 mol l−1. The method can be used for Cr(VI) determination in the presence of up to 50 mg l−1 of humic acid. The validation of the method was carried out by studying the recovery of Cr(VI) from spiked river water and by the comparison of the results of determination of Cr(VI) in a soil sample. The method cannot be used for analysis of samples containing high concentrations of chloride ions such as seawater and estuarine water.  相似文献   

2.
A series of chromium(III) complexes [Cr(bipy)(HC2O4)2]Cl·3H2O (1), [Cr(phen)(HC2O4)2]Cl·3H2O (2), [Cr(phen)2(C2O4)]ClO4 (3), [Cr2(bipy)4(C2O4)](SO4)·(bipy)0.5·H2O (4) and [Mn(phen)2(H2O)2]2[Cr(phen)(C2O4)2]3ClO4·14H2O (5) were synthesized (bipy=4,4′-bipyridine, phen=1,10-phenanthroline), while the crystal structures of 1 and 3–5 have been determined by X-ray analysis. 1 and 3 are mononuclear complexes, 4 contains binuclear chromium(III) ions and 5 is a 3D supromolecule formed by complicated hydrogen bonding. 1–3 are potential molecular bricks of chromium(III) building blocks for synthesis heterometallic complexes. When we use these molecular bricks as ligands to react with other metal salts, unexpected complexes 4 and 5 are isolated in water solution. The synthesis conditions and reaction results are also discussed.  相似文献   

3.
Summary Chromium can be present in aqueous solution as Cr(VI) or in monomeric, dimeric, trimeric and higher polymeric forms of Cr(III). Many monomeric forms of Cr(III) are possible, with the water molecules of Cr(H2O) 6 3+ substituted by anionic or neutral species. This proliferation of Cr(III) species makes the complete speciation of chromium a continuing challenge to the analyst. A simple and effective cation exchange procedure for the separation of various of these species uses a small glass column containing 1 mL of pre-treated cation exchange resin (Na+ form). Stepwise elution with solutions of perchloric acid, Ca2+ (pH=2) and La3+ (pH=2) separates Cr(VI) and seven Cr(III) species from CrX3 to tetramer. Radiometric (Cr-51), spectrophotometric and other detection methods can be employed; the use of radiochromium gives the lowest detection limit.  相似文献   

4.
Groundwater samples collected from a tannery contaminated area were analyzed for chromium species with the objective of investigating the interference of Cr(III)-organic complexes in the determination of Cr(VI) using APDC–MIBK extraction procedure. The contribution of Cr(III), Cr(VI) and Cr(III)-organic complexes towards total chromium ranged between 2 and 61%, 27 and 86%, and, 6 and 23%, respectively. The Cr(III)-organic complexes were not extractable by APDC–MIBK, however, HNO3 digestion released the organic bound Cr(III). Interference of organic bound Cr(III) in Cr(VI) determination due to MIBK soluble Cr(III) was not observed. Significant difference between total dissolved chromium determined after appropriate digestion procedure, and the sum of dissolved Cr(III) and Cr(VI) determined indicates the presence of the Cr(III)-organic complexes. MIBK extraction of samples without APDC is an useful way to check the extractability of organic bound Cr(III). The presence of soluble Cr(III)-organic complexes thus add complexity to chromium speciation analysis by APDC–MIBK procedure.  相似文献   

5.
《Analytical letters》2012,45(13-14):2877-2885
Abstract

The adsorption studies of Cr(VI) in presence of Cr(III) on the sulphide of Lead, Zinc and Copper has been studied. It has been found that in case of lead sulphide 100% adsorption of Cr(VI) took place at pH 4.0 and of Cr(III) at pH 7.0. While in case of zinc sulphide the 100% adsorption of Cr(VI) took place at pH 4.5 and of Cr(III) at pH 6.5. In case of copper sulphide 100% adsorption of Cr(VI) took place at pH 5.0 and of Cr(III) at pH 7.0. This difference in adsorption at different pH values forms the basis for the determination of these ions. The method is accurate.  相似文献   

6.
Speciation of Cr(III) and Cr(VI) can be attained by flow injection analysis with amperometric detection. Cr(VI) is reduced in an acidic medium to Cr(III) with a glassy carbon electrode at —0.1 V vs. Ag/AgCl and the current is recorded. Cr(III) is oxidised on-line to Cr(VI) with alkaline hydrogen peroxide solution. From the difference of the total chromium and Cr(VI), the amount of Cr(III) was obtained. A linear calibration curve for Cr(VI) was obtained for the concentration ranges 0.01-5.0ppm of Cr(VI) and we have calculated the limit of determination to be about 0.5ppb. We have studied the degree of reproducibility obtained using the solid electrodes under various conditions. The influence of flow rate, coil length, interfenences and the extent of reaction were studied.  相似文献   

7.
Feasibility and limitations of direct coupling of high performance liquid chromatographic (HPLC) separation to microwave induced plasma (MIP)-optical emission spectrometry (OES) for elementspecific detection was tested and compared to inductively coupled plasma (ICP)-optical emission spectrometric detection on the basis of the Cr(III)/Cr(VI) speciation analysis of water samples. Coupling was performed by a hydraulic high pressure nebulizer (HHPN) radiative-heating/watercooling interface which provides about 20 % and 80 % aerosol yield in the case of helium and argon carrier gases, respectively. Desolvation efficiency of aqueous solutions was approximately 80 %. Applying the ion-pair HPLC separation, the organic eluents and reagents in the MIP cause a 50–75 % signal suppression for Cr(VI) and 25–50 % for Cr(III). In a pure aqueous solution the MIP Cr(VI) signal was by 20 % lower than that of Cr(III). These effects were lower using the ICP source, but they cannot be neglected. Easily ionizable matrix elements (Na, Ca) can cause 70 % signal suppression in the MIP, and 20 % in the ICP. Therefore, species dependent calibration is required in both cases. In the case of HPLC detection by MIP-OES, the detection limit was 13 ng for Cr(III), and 18 ng for Cr(VI). Using the ICP-OES detection, the detection limit was 0.2 ng for Cr (III) and 0.4 ng for Cr (VI). The linear dynamic ranges in both cases were two orders of magnitude. Presented at the XVIIIth Slovak Spectroscopic Conference, Spišská Nová Ves, 15–18 October 2006.  相似文献   

8.
A simple, rapid and sensitive method for the determination of chromium(III) and total chromium using the simple dual T channels on glass chip with negative pressure pumping system and chemiluminescence (CL) detection is presented. The CL reaction was based on luminol oxidation by hydrogen peroxide in basic aqueous solution catalyzed by chromium(III). Total chromium in form of chromium(III) was achieved after chromium(VI) was completely reduced by acidic sodium hydrogen sulfite. Total chromium could then be determined with the same strategy as the chromium(III). The CL reagent was composed of 1.0 × 10−4 mol/L luminol, 1.0 × 10−2 mol/L hydrogen peroxide and 0.10 mol/L sodium bromide in 0.050 mol/L carbonate buffer (pH 11.00). The 1.0 × 10−2 mol/L ethylenediaminetetraacetic acid was added into the sample solution in order to improve the selectivity. Chromium(III) could be detected at a notably concentration of 1.6 × 10−16 mol/L and a linear calibration curve was obtained from 1.0 × 10−15 to 1.0 × 10−13 mol/L. The sample and CL reagent consumption were only 15 and 20 μL, respectively. The analysis time was less than 1 min per sample with the precision (%R.S.D.) was 4.7%. The proposed method has been applied successfully to the analysis of river water, mineral waters, drinking waters and tap water. Its performance was verified by the analysis of certified total chromium-reference materials and by recovery measurement on spiked synthetic seawater sample.  相似文献   

9.
A rapid, sensitive and selective procedure for determination of Cr(III) and Cr(VI) in environmental and industrial liquid samples via preconcentration with ammonium pyrrolidine dithiocarbamate (APDC) and determination by means of the EDXRF was described. The effect of pH in the range of 3-11 on the recovery of Cr(III) and Cr(VI) has been investigated separately and in combination of these two species. The influence of organic matter, carbonate species and elements V, Mn and Fe on the recovery of each chromium specie (separately/in combination) over whole pH range was also tested in order to simulate condition occurring in natural waters that usually contain certain amount of dissolved organic matter and carbonate ions. Cr(VI) and Cr(III) have shown different behaviors in reaction with APDC at different pH ranges and therefore it is possible to separate those two species. It was found that Cr(VI) creates complex with APDC only in the pH range from 3 to 5 with quantitative recovery (app. 98%) at pH 3, but there was no recovery of Cr(III) at that pH. On the contrary, in pH range from 6 to 11, reaction with Cr(III) and APDC reviled that the only reaction product is Cr(OH)3 instead of the expected Cr(III)-APDC complex. All reaction products were characterized by IR spectroscopy.  相似文献   

10.
The acid–base properties of analogous complex ions of chromium(III) and cobalt(III) in aqueous solution have been studied. The equilibrium constants for all metal complexes were determined by using potentiometric and spectrophotometric titration methods. First, dissociation constants for the studied complexes of Cr(III) and Co(III) were determined by means of the potentiometric titration method and using the STOICHIO computer programme. Then, pH-spectrophotometric titrations were performed and the OriginPro 7.5 computer programme was used to calculate the same constants. The measurements using both methods were carried out under the same conditions of temperature, T = 298.15 K, and over the same pH range 2.00–10.00, respectively. It turned out that the two methods used enabled us to obtain acidity constants in very good agreement.  相似文献   

11.
12.
A simple, inexpensive method based on solid-phase extraction (SPE) on sawdust from Cedrus deodera has been developed for speciation of Cr(III) and Cr(VI) in environmental water samples. Because different exchange capacities were observed for the two forms of chromium at different pH—Cr(III) was selectively retained at pH 3 to 4 whereas Cr(VI) was retained at pH 1—complete separation of the two forms of chromium is possible. Retained species were eluted with 2.5 mL 0.1 mol L−1 HCl and 0.1 mol L−1 NaOH. Detection limits of 0.05 and 0.04 μg mL−1 were achieved for Cr(III) and Cr(VI), respectively, with enrichment factors of 100 and 80. Recovery was quantitative using 250 mL sample volume for Cr(III) and 200 mL for Cr(VI). Different kinetic and thermodynamic properties that affect sorption of the chromium species on the sawdust were also determined. Metal ion concentration was measured as the Cr(VI)–diphenylcarbazide complex by UV–visible spectroscopy. The method was successfully applied for speciation of chromium in environmental and industrial water samples.  相似文献   

13.
A sensitive and selective method has been developed to determine Cr(III) and total Cr in natural water samples by ICP-AES with a Cr(III)-imprinted aminopropyl-functionalised silica gel adsorbent. The Cr(III)-imprinted and non-imprinted adsorbent were prepared by an easy one-step reaction with a surface imprinting technique. Their maximum static adsorption capacities for Cr(III) were 11.12 mg g?1 and 3.81 mg g?1, respectively. The relative selectivity factors (α r) for Cr(III)/Co(II), Cr(III)/Au(III), Cr(III)/Ni(II), Cr(III)/Cu(II), Cr(III)/Zn(II), and Cr(III)/Cr(VI), were 377, 21.4, 15.4, 27.7, 26.4, and 31.9, respectively. Under the optimal conditions, Cr(III) can be absorbed quantitatively, but Cr(VI) was not retained. Total chromium was obtained after reducing Cr(VI) to Cr(III) with hydroxyammonium chloride. The detection limit (3σ) for Cr(III) was 0.11 ng mL?1. The relative standard deviation was 1.2%. The proposed method has been validated by analysing two certified reference materials and successfully applied to the determination and speciation of chromium in natural water samples with satisfactory results.  相似文献   

14.
A method is described for the selective extraction of chromium(III) from aqueous solutions and natural water samples, based on the use of two newly synthesized solid-phase extractors via silica gel-immobilized-vanillin derivatives (I,II). Experimental conditions for effective adsorption of trace levels of Cr(III) were optimized with respect to different experimental parameters using batch and column procedures in detail. The optimum pH values for the separation of Cr(III) simultaneously on the newly sorbents were both 4.0 and complete elution of Cr(III) from the sorbents surface was carried out using 2.0 mL of 0.5 mol L− 1 HCl. The sorption capacity of phase I towards Cr(III) was found to be 0.700 mmol g− 1 where the sorption capacity of phase II was 0.538 mmol g− 1. The detection limits (3σ) of the method defined by IUPAC were found to be 0.87 and 0.64 ng mL− 1 with enrichment factors of 100 and 75 for phases I and II, respectively. The method has been applied for the determination of Cr(III) in biological materials and water samples with satisfactory results.  相似文献   

15.
Summary A method for simultaneous determination of Cr(III) and Cr(VI), using sodium diethyldithiocarbamate as chelating agent is given. At room temperature and pH 5.8 sodium diethyldithiocarbamate reacts with both Cr(III) and Cr(VI). Examination of this reaction by reversed phase high-performance liquid chromatography, makes it possible to correct for the interference between Cr(III) and Cr(VI) when determining the amount of Cr(III) present in the solution.  相似文献   

16.

Twenty-five uncultivated surface soil samples collected from the northern and southern regions of Dhaka Export Processing Zone (DEPZ), industrial area of Bangladesh, were analyzed for their contents of Y, lanthanides and natural radionuclides (Th and U) using an inductively coupled plasma mass spectrometer (ICP-MS). Analogous concentrations of the Y, lanthanides, Th and U were observed in the both regions of DEPZ around several kilometer distances. Further, the measured values showed no particular contamination. However, the concentrations of the light lanthanides (La, Ce and Nd) in the Bangladeshi soils were around twice the worldwide average value. But, the smooth curve of the chondrite normalized patterns of the lanthanides suggested that the lanthanide contents of the Bangladeshi soils in this area are the results of the natural dispersion process rather than anthropogenic activities. In addition, the relatively high Th and U concentrations and Th/U ratio were observed in Bangladeshi soils of this area, most likely due to the effect of their parent materials such as clay stones which have a high Th/U ratio. Since this is the first precise result for the Y, lanthanides, Th and U contents in Bangladeshi soils, it could be useful in understanding the background level and the characteristics of these elements in Bangladeshi soils.  相似文献   

17.
18.
A method is presented for the simultaneous determination of Cr(III) and Cr(VI) in yeast using species-specific double-spike isotope dilution (SSDSID) with anion-exchange liquid chromatography (LC) separation and sector field inductively coupled plasma mass spectrometric (SF-ICP-MS) detection. Total Cr is quantitated using ID SF-ICP-MS. Samples were digested on a hot plate at 95±2 °C for 6 h in an alkaline solution of 0.5 M NaOH and 0.28 M Na2CO3 for the determination of Cr(III) and Cr(VI), whereas microwave-assisted decomposition with HNO3 and H2O2 was used for the determination of total Cr. Concentrations of 2,014±16, 1,952±103 and 76±48 mg kg−1 (one standard deviation, n=4, 3, 3), respectively were obtained for total Cr, Cr(III) and Cr(VI) in the yeast sample. Significant oxidation of Cr(III) to Cr(VI) (24.2±7.6% Cr(III) oxidized, n=3) and reduction of Cr(VI) to Cr(III) (37.6±6.5% Cr(VI) reduced, n=3 ) occurred during alkaline extraction and subsequent chromatographic separation at pH 7. Despite this significant bidirectional redox transformation, quantitative recoveries for both Cr(III) and Cr(VI) were achieved using the SSDSID method. In addition, mass balance between total Cr and the sum of Cr(III) and Cr(VI) concentrations was achieved. Method detection limits of 0.3, 2 and 30 mg kg−1 were obtained for total Cr, Cr(VI) and Cr(III), respectively, based on a 0.2-g sub-sample.  相似文献   

19.
The use of organic solvents to increase metal ion determination sensitivity by atomic absorption spectrophotometry with flame is quite common. The most employed organic solvent is 4-methyl-2-pentanona (methylisobutylketone, MIBK) which optimizes sample vaporization and combustion. In this work, we present the use of a homogeneous mixture of water-ethanol—MIBK solvents (1:14:10 v/v, respectively), named the single-phase solution instead of employing pure organic solvents to determine chromium (III) ions by atomic absorption spectrophotometry with flame. The analytical calibration curve in single-phase solution evaluated up to 8 μg ml−1 was linear and was described as Abs=0.0048 CCr(III)-0.0010 (r2=0.9998). Stability in the measurement as well as an increase in sensitivity more than twice as high when compared to determinations exclusively made in aqueous solutions were observed. The exactness of the determinations was evaluated with the same steel standards.  相似文献   

20.
《Electroanalysis》2017,29(5):1222-1231
A microbial sensor, namely carbon paste electrode (CPE) modified with Citrobacter freundii (Cf–CPE) has been developed for the detection of hexavalent (Cr(VI)) and trivalent (Cr(III)) chromium present in aqueous samples using voltammetry, an electroanalytical technique. The biosensor developed, demonstrated about a twofold higher performance as compared to the bare CPE for the chosen ions. Using cyclic voltammetry and by employing the fabricated Cf–CPE, the lowest limit of detection (LLOD) of 1x10−4 M and 5x10−4 M for Cr(VI) and Cr(III) ions respectively could be achieved. By adopting the Differential Pulse Cathodic Stripping Voltammetric technique, the LLOD could be further improved to 1x10−9 M and 1x10−7 M for Cr(VI) and Cr(III) ions respectively using the biomodified electrodes. The reactions occurring at the electrode surface‐chromium solution interface and the mechanisms of biosorption of chromium species onto the biosensor are discussed. The stability and utility of the developed biosensor for the analysis of Cr(VI) and Cr(III) ions in chromite mine water samples has been evaluated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号