首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Analysis in a single particle mode of gold colloids in water has been performed by inductively coupled plasma-mass spectrometry (ICP-MS). The signal induced by the flash of ions due to the ionization of a colloid in the plasma torch can be measured for the ions 197Au+ by the mass spectrometer without interferences. The intensity of the MS signal is recorded in time scan. The recorded peak distributions were analysed as a function of the colloid size for five monodisperse colloids (80-250 nm). This study describes the experimental conditions to analyse gold colloids in a single particle mode. The size detection limit is around 25 nm corresponding to 0.15 fg colloids and one particle per ml may be detected during a 1 min time scan within standard procedure.  相似文献   

2.
Degueldre C  Favarger PY 《Talanta》2004,62(5):1051-1054
Thorium colloid analysis in water has been carried out by a single particle mode using inductively coupled plasma mass spectrometry (ICP-MS). The flash of ions due to the ionisation of a thorium colloidal particle in the plasma torch can be detected and measured in a time scan for 232Th+ or 248[ThO]+ according to the sensitivity required by the mass spectrometer. The peaks of the recorded intensity of the MS signal can be analysed as a function of the particle size or fraction of the studied element in the colloid phase. The frequency of the flashes is directly proportional to the concentration of particles in the colloidal suspension. After discussing Th colloid detection, on the basis of the intensity of the ion flashes generated in the plasma torch, tests were performed on thorium dioxide colloidal particles. This feasibility study also describes the experimental conditions and the limitation of the plasma design to detect thorium colloids in a single particle analysis mode down to about 10 fg.  相似文献   

3.
At present there is an increasing concern as regards the release of potentially toxic metals into the environment. Volcanic eruptions are a natural source of metals and metalloids in the atmosphere. Toxic trace elements ejected during an eruptive episode may produce hazardous effects for people and the environment in areas close to the volcano. In this context, a study was undertaken to investigate the concentration of metal and metalloids in ashes ejected from Copahue volcano, Neuquén, Argentina. Two samples (A and B) of deposited particles were collected one day after the first eruption and size-fractionated in four sub-samples (S1, S2, S3 and S4). Analysis was performed by inductively coupled plasma-mass spectrometry (ICP-MS) and the accuracy for the entire analytical procedure was performed by means of the certified reference material CRM GBW 07105 Rocks (NRCCRM, China). The elements considered were: As, Cd, Cr, Cu, Hg, Ni, Pb, Sb, U, V and Zn. The adverse effect of potentially interfering species on the mass-spectrometric determination of these elements was also taken into account. The concentration intervals found in the four fractions are as follows (in μg g−1): As, 6.0-2.6; Cd, 0.71-0.36; Cr, 29.5-54.0; Cu, 132-49.0; Hg, 0.020-0.007; Ni, 36.0-26.0; Pb, 15.5-2.55; Sb, 1.07-0.30; U, 2.57-1.94; V, 152-106; Zn, 85.5-55.0. The elements with the highest concentrations were: Cu, V and Zn. All fractions, in both samples, were found to be enriched in some toxic trace elements in the following order Sb>Cd>As. On the contrary, samples were depleted in Ni, Cr and Hg. Lead was the element that exhibits a noticeable difference in concentration between the finer and coarser fractions.  相似文献   

4.
5.
An inductively coupled plasma mass spectrometry (ICPMS) coupled with gas to particle conversion-gas exchange technique was applied to the direct analysis of ultra-trace semiconductor gas in ambient air. The ultra-trace semiconductor gases such as arsine (AsH3) and phosphine (PH3) were converted to particles by reaction with ozone (O3) and ammonia (NH3) gases within a gas to particle conversion device (GPD). The converted particles were directly introduced and measured by ICPMS through a gas exchange device (GED), which could penetrate the particles as well as exchange to Ar from either non-reacted gases such as an air or remaining gases of O3 and NH3. The particle size distribution of converted particles was measured by scanning mobility particle sizer (SMPS) and the results supported the elucidation of particle agglomeration between the particle converted from semiconductor gas and the particle of ammonium nitrate (NH4NO3) which was produced as major particle in GPD. Stable time-resolved signals from AsH3 and PH3 in air were obtained by GPD-GED-ICPMS with continuous gas introduction; however, the slightly larger fluctuation, which could be due to the ionization fluctuation of particles in ICP, was observed compared to that of metal carbonyl gas in Ar introduced directly into ICPMS. The linear regression lines were obtained and the limits of detection (LODs) of 1.5 pL L−1 and 2.4 nL L−1 for AsH3 and PH3, respectively, were estimated. Since these LODs revealed sufficiently lower values than the measurement concentrations required from semiconductor industry such as 0.5 nL L−1 and 30 nL L−1 for AsH3 and PH3, respectively, the GPD-GED-ICPMS could be useful for direct and high sensitive analysis of ultra-trace semiconductor gas in air.  相似文献   

6.
The paper describes the application of laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) for the isotopic analysis of individual uranium-oxide particles. The procedure developed is suitable for the accurate measurement of 234U, 235U, 236U and 238U isotopes in single actinide particles with lateral dimensions down to 10 μm. The 235U/238U isotope ratios can be obtained with a precision of a few percent relative standard deviation using a single collector ICP-MS instrument. The precision could be improved by the use of slow ablation and by taking several LA-ICP-MS replicate spectra on the same particle investigated. For the minor isotopes use of higher mass resolution (R = 4000) was necessary in some cases to avoid spectral interferences. The technique developed offers a rapid and accurate possibility for the isotopic composition determination of uranium-containing individual particles in environmental and safeguards samples.  相似文献   

7.
电感耦合等离子质谱法测定染铅猪仔的血铅、尿铅含量   总被引:1,自引:0,他引:1  
利用电感耦合等离子质谱法测定染铅猪仔的血铅、尿铅含量.铅元素校正曲线的相关系数达到0.9999,方法检出限为0.08 μg/L.用冻干牛血铅、镉成分分析标准物质和冻干人尿铅成分分析标准物质验证了方法的准确性和重复性,分析结果表明,测定值与标准值基本吻合,测定值的相对标准偏差<3.4%.用此方法分析了染铅猪仔不同时段的血...  相似文献   

8.
Liu R  Xing Z  Lv Y  Zhang S  Zhang X 《Talanta》2010,83(1):48-54
A sensitive sandwich type immunoassay has been proposed with the detection by inductively coupled plasma mass spectrometry (ICP-MS) in a single particle mode (time resolved analysis). The signal induced by the flash of ions (197Au+) due to the ionization of single Au-nanoparticle (Au-NP) label in the plasma torch can be measured by the mass spectrometer. The frequency of the transient signals is proportional to the concentration of Au-NPs labels. Characteristics of the signals obtained from Au-NPs of 20, 45 and 80 nm in diameters were discussed. The analytical figures for the determination of Au-labeled IgG using ICP-MS in conventional integral mode and single particle mode were compared in detail. Rabbit-anti-human IgG was used as a model analyte in the sandwich immunoassay. A detection limit (3σ) of 0.1 ng mL−1 was obtained for rabbit-anti-human IgG after immunoreactions, with a linear range of 0.3-10 ng mL−1 and a RSD of 8.1% (2.0 ng mL−1). Finally, the proposed method was successfully applied to spiked rabbit-anti-human IgG samples and rabbit-anti-human serum samples. The method resulted to be a highly sensitive ICP-MS based sandwich type immunoassay.  相似文献   

9.
研究了在电感耦合等离子体质谱分析中雾室温度对仪器分析性能的影响情况。在实验中选取半导体对雾室进行制冷,结果表明随着半导体制冷温度升高,进入等离子体水蒸气和分析元素气溶胶的量增加,但水蒸气引入量的增加幅度明显大于气溶胶,温度每增加1℃,等离子体中水的负载量增加2 3%,而气溶胶则只增加0.35%。同时随着半导体制冷温度的升高,分析元素的灵敏度下降,氧化物干扰增强,但氧化物的计数并未增加。根据元素灵敏度和氧化物干扰随半导体制冷温度变化的差异性,对人工模拟高纯Sm2O3中杂质稀土元素Dy、Ho、Er、Yb的量进行了计算,通过与模拟加入量比较,证明使用这种方法可对高纯稀土中某些受基体元素氧化物离子严重干扰的稀土元素进行快速定量分析,分析结果的偏差小于20%。  相似文献   

10.
An analytical procedure for selenium speciation of analysis of selenourea (SeU), selenoethionine (SeE), selenomethionine (SeM), Se(VI), Se(IV), dimethylselenide (dMeSe) and dimethyldiselenide (dMedSe) was developed, based on two complementary liquid chromatography (LC) techniques coupled with inductively coupled plasma-mass spectrometry (ICP-MS). Specifically, strong anion exchange (SAX) chromatography coupled with ICP-MS was used for the separation and quantification of all the earlier mentioned Se compounds, except for the two methyl selenides, which could be separated and determined by reversed phase chromatography coupled with ICP-MS. This procedure was applied to a soil sample from the warm springs area of Thermopyles (Greece). For leaching the Se species from the soil sample, four extraction methods, using water at ambient temperature, hot water, methanol and 0.5 M HCl, were tested for their efficiency of extracting the different Se species. The speciation results obtained by the LC-ICP-MS methods were compared with those obtained by voltammetric techniques. The determination of total selenium in the sample was achieved by graphite furnace atomic absorption spectrometry, as well as by ICP-atomic emission spectrometry, after suitable digestion of the sediment sample.  相似文献   

11.
A chitosan resin derivatized with 3,4-dihydroxybenzoic acid moiety (CCTS-DHBA resin) was newly synthesized for the collection/concentration of trace uranium by using cross-linked chitosan (CCTS) as base material, and the adsorption behavior of uranium as well as 60 elements on the resin was examined by passing the sample solutions through a mini-column packed with the resin. After the elution of the collected elements on the resin with 1 M HNO3, the eluates were measured by inductively coupled plasma-mass spectrometry (ICP-MS).The CCTS-DHBA resin can adsorb several metal cations and several oxoanionic elements at appropriate pH. Among these metal ions, uranium shows an excellent adsorption behavior on this resin. Uranium as UO22+ species can be adsorbed on the resin by chelating mechanism with adsorption capacity of 330 mg g−1 resin. Through the column treatment, the complete removal of large amounts of alkali and alkaline earth matrices without any loss of adsorption efficiency over prolonged usage were achieved with this resin.The CCTS-DHBA resin was applied to the adsorption/collection of uranium in tap water, river water and seawater samples with satisfactory results. The validation of the proposed method was carried out by analyzing uranium in the standard reference materials of SLRS-4, CASS-4, and NASS-5 after passing through the CCTS-DHBA resin, and the results showed good agreement with the certified values.  相似文献   

12.
A new method using microwave digestion combined with inductively coupled plasma-mass spectrometry (ICP-MS) was studied to analyze the elemental composition of a variety of komatiites samples. Microwave digestion consisted in two-stage heating and pressurizing acid treatments for maximum dissolution of the samples. We report here different quality control measurements (external and internal calibration, monitoring of reference materials) which involve standard deviation calculations and recovery examinations in order to test the precision and accuracy of the analytical procedure. Data for 17 elements (Na, P, K, T, V Cr, Mn, Co, Ni, Cu, Zn, Zr, Pb, Al, F, Ca and Mg) in eight komatiite samples and two USGS basalt reference samples (BCR-2 and BHVO-2) are presented. We evaluate our new digestion and instrumental procedure. The element concentration obtained for BCR-2 and BHVO-2 agreed well with the certified values, the relative standard deviations were lower than 5% and recoveries were good. Our analytical results demonstrate that it reproduces accurately the concentrations of minor and trace elements in komatiites. The ease of digestion of the samples and the speed (less than 12 h) to digest the komatiite material makes this technique an efficient method to be used easily and routinely for preparing and analyzing komatiites samples for multiple elements determination.  相似文献   

13.
Different collision gases (H2, He and premixed 7% H2 in He) used in the hexapole collision cell of an inductively coupled plasma-mass spectrometer (ICP-MS) were compared, and the gas-flow rates were optimized for the determination of arsenic (), iron () and selenium (). The study showed that the argon-based interferences at mass-to-charge ratios (m/z) of 56, 75 and 80 can be overcome by the optimized gas flows (7.5 ml min−1 premixed 7% H2 in He and 2 ml min−1 H2) in the hexapole collision cell. Detection limits of 15.5 ng l−1 for iron () and 29 ng l−1 for selenium () in 2% (v/v) HNO3 were obtained under optimized collision cell conditions. The detection limit for arsenic () obtained in difficult hydrochloride acid matrix (5% HCl (v/v)) was 153 ng l−1. The accuracy of the optimized method was confirmed by analyzing two moss reference materials. The results obtained by ICP-MS for arsenic, selenium and iron from both moss reference samples were, in most cases, in good agreement with the certified values.  相似文献   

14.
A method was developed to improve the precision of inductively coupled plasma quadrupole mass spectrometry (ICP-QMS) for the determination of boron isotope ratios (11B/10B) in various environmental materials including seawater. This approach is based on the common analyte internal standardization (CAIS) chemometric algorithm. The sample solution obtained after digestion is spiked with lithium, and both 7Li/6Li and 11B/10B values are measured using long-counting periods (20 min). The CAIS algorithm corrects the measured 11B/10B values for (a) statistical fluctuations resulting from short-term noise; (b) drift in 11B-to-10B ratio as a result of long-term deviation in instrumental parameters likely to occur during long counting times; (c) change in 11B-to-10B ratio caused by variation in matrix elements concentrations; and (d) drift in mass bias correction factor. Comparing boron isotopic ratios in seawater measured by conventional and the new isotope ratio methods validates the procedure. A synthetic isotopic mixture of boron SRM 951 and enriched 10B SRM 952 also was examined. The CAIS method provided a measured boron isotopic ratio precision of 0.05% R.S.D. while eliminating 5.1% matrix concentration error and 0.25% instrumental drift error.  相似文献   

15.
The suitability of the semi-quantitative mode of analysis of a Perkin-Elmer inductively coupled plasma quadrupole-mass spectrometer for multi-element characterization of fortified and table wines was tested. The samples, embracing red and white table, and Port wines, were first submitted to an UV-irradiation pre-treatment. The same samples were analysed, in parallel, by using the quantitative mode of the same equipment, and the results were compared. External calibration with aqueous standards was used in the quantitative mode and calibration with only one aqueous multi-element standard was used in the semi-quantitative mode. Thirty elements, including major, minor and trace elements (Al, Ba, Cd, Co, Cr, Cu, Fe, Ga, Li, Mn, Ni, Pb, Rb, Sr, V, Zn and the rare earth elements (REEs) La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu) were measured by the two modes of analysis. For most elements the semi-quantitative mode provided two to six times higher limits of detection than those obtained by the quantitative mode. The precision of the results were similar for both modes, with relative standards deviation between 0.5 and 5%, in many cases. Comparable values of concentration (differences <20%) were obtained by the two methodologies, except for Cd, Ga, Li and the REEs. A linear least-squares adjustment of the two global sets of results (semi-quantitative mode (y-axis) versus quantitative mode (x-axis)) yielded the equation: y=(0.93±0.01)x+(1±11) with a very high correlation coefficient of 0.9992 (n=40). Although the results obtained by the semi-quantitative mode were, on average, slightly lower than those given by the quantitative mode (slope <1), semi-quantitative analysis can be an important tool for comparison of elemental compositions of wines, including fortified wines. It gives rapid information about the concentration levels of a large number of elements, and presents some economic advantages relatively to the quantitative mode: it is faster and requires fewer reagents.  相似文献   

16.
建立了铀颗粒物中铀全同位素比值的分析方法,采用双面胶带装载铀颗粒物样品,优化激光烧蚀-多接收电感耦合等离子体质谱的运行参数,用标准样品交叉法校正质量分馏和探测器检测效率,测定了粒径几十微米的铀标准物质CRM124-1、GBW04234和GBW04238中铀全同位素比值.本方法对铀颗粒物中235U/238U、234 U/235U和236 U/235U测量的相对实验标准不确定度分别小于0.050%,1.7%和1.8%,测量结果与参考值在不确定度范围内符合.研究表明,本方法可快速、准确、高精度地测定铀颗粒物中铀全同位素比值.  相似文献   

17.
The analysis of some Italian mineral waters by ICP-MS has revealed errors in the determination of As and Cr in natural effervescent or carbonated waters due to the presence of dissolved inorganic carbon (DIC). This leads to overestimate As and Cr in 1% (v/v) HNO3 acidified samples, analysed within 1-2 h after the acidification. The overestimation of As concentration is caused by matrix interferences producing a signal enhancement due to the presence of dissolved inorganic carbon. This effect is analogous to that observed in the presence of organic carbon and occurs at millimolar DIC levels. The overestimation of Cr concentration is due to the 40Ar12C+ species interfering with 52Cr+ despite the use of the octopole reaction system. The optimization of the He flow in the collision cell can solve the latter problem, but the required increase in the flow rate decreases the sensitivity of the ICP-MS technique. The observed effects in CO2 rich mineral waters and artificial NaHCO3 solutions suggest that 5-10 mM DIC levels may affect the determination of As and Cr concentration in thermal waters, rivers, lakes and groundwaters.  相似文献   

18.
电感耦合等离子体质谱技术最新进展   总被引:22,自引:0,他引:22  
李冰  杨红霞 《分析试验室》2003,22(1):94-100
对1998年以来电感耦合等离子体质谱技术(ICP-MS)的最新进展作一简要回顾。内容包括同位素比值分析、双聚焦扇形磁场高分辨ICP-MS、多接收器磁扇形等离子体质谱仪(MC-ICP-MS)、飞行时间等离子体质谱仪(ICP-TOF-MS)、“冷”等离子体及屏蔽炬技术以及动态碰撞/反应池技术等进展。  相似文献   

19.
The feasibility of microwave energy to assist the solubilisation of edible seaweed samples by tetramethylammonium hydroxide (TMAH) has been investigated to extract iodine and bromine. Inductively coupled plasma-mass spectrometry (ICP-MS) has been used as a multi-element detector. Variables affecting the microwave assisted extraction/solubilisation (temperature, TMAH volume, ramp time and hold time) were firstly screened by applying a fractional factorial design (25-1 + 2), resolution V and 2 centre points. When extracting both halogens, results showed statistical significance (confidence interval of 95%) for TMAH volume and temperature, and also for the two order interaction between both variables. Therefore, these two variables were finally optimized by a 22 + star orthogonal central composite design with 5 centre points and 2 replicates, and optimum values of 200 °C and 10 mL for temperature and TMAH volume, respectively, were found. The extraction time (ramp and hold times) was found statistically non-significant, and values of 10 and 5 min were chosen for the ramp time and the hold time, respectively. This means a fast microwave heating cycle. Repeatability of the over-all procedure has been found to be 6% for both elements, while iodine and bromine concentrations of 24.6 and 19.9 ng g−1, respectively, were established for the limit of detection. Accuracy of the method was assessed by analyzing the NIES-09 (Sargasso, Sargassum fulvellum) certified reference material (CRM) and the iodine and bromine concentrations found have been in good agreement with the indicative values for this CRM. Finally, the method was applied to several edible dried and canned seaweed samples.  相似文献   

20.
The impact of brominated flame retardants (BFRs) on the environment and their potential risk in animal and human health is a present concern. Therefore, existing legislation in the European Union demands that polymers with BFRs are identified and eliminated from the recycling process due to their potential health hazard.In this work, a flow-injection (FI) system coupled to inductively coupled plasma-mass spectrometry (ICP-MS) was optimized for the detection of traces of bromine in polymers, plastic paints and enamels containing BFRs. Sample preparation requires a microwave-assisted digestion in order to transfer bromine in polymeric samples to solution. After appropriate optimization of the digestion procedure and the ICP-MS detection, a detection limit (DL) of 4.2 mg kg−1 was obtained for synthesized polyurethane standards containing known concentrations of bromine. The precision of the proposed method, evaluated as the R.S.D. of signals obtained for three replicates of polymeric standard BFRs at the normative EU level, was as low as 3.6%.This simple developed methodology was characterized for the screening of bromine in polymeric matrices. The proposed system provides rapid binary yes/no overall responses, being appropriate for the screening of bromine above a pre-set concentration threshold. The unreliability region (UR), given by the probability of false positives and false negatives (set at 5% in both cases), was in the range between 442 and 678 mg kg−1 of bromine (at a cut-off level of 0.1% in BFRs by weight of homogeneous material fixed by the EU normative). Finally, the applicability of the proposed screening system was tested for the reliable control of bromine in different commercial samples including flame-retardant paints and enamels.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号