1.
The robustness testing of a normal-phase liquid chromatographic (LC) method for the determination of R-timolol and other related substances in S-timolol maleate was performed applying a two-level Plackett-Burman design. Two qualitative and five quantitative factors were examined. Two types of responses were considered, qualitative, i.e. chromatographic performance criteria, and quantitative ones. The latter were taken into account to determine if the analytical procedure was robust. The quantitative responses were the contents of R-timolol in two S-timolol maleate samples. Even though some significant factor effects were observed on the qualitative responses, the R-timolol contents were not significantly different from those observed at nominal conditions, which demonstrated the robustness of the procedure.Since the experiments of the Plackett-Burman design can be assimilated to laboratories in an interlaboratory study, uncertainty can be evaluated using the robustness test data. The robustness test was set-up in such a way that the required variances could be estimated. It was shown that the robustness set-up allows estimating the reproducibility uncertainty without performing an interlaboratory study.  相似文献   

2.
3.
The aim of this paper is to compare the performance parameters of the Volhard method for chlorides determination obtained applying the bottom-up approach with those experimentally achieved. The method precision, trueness, detection and quantification limits and ruggedness are determined analysing various foods with different chloride contents. Otherwise, the measurement uncertainty is assessed applying the bottom-up approach using only pen and paper. The comparison between the performances established with both methods shows the validity of the metrological approach for volumetric procedures. Presented at AOAC Europe/Eurachem Symposium March 2005, Brussels, Belgium  相似文献   

4.
Erythromycin is a mixture of macrolide antibiotics produced by Saccharopolyspora erythreas during fermentation. A new method for the analysis of erythromycin by liquid chromatography has previously been developed. It makes use of an Astec C18 polymeric column. After validation in one laboratory, the method was now validated in an interlaboratory study. Validation studies are commonly used to test the fitness of the analytical method prior to its use for routine quality testing. The data derived in the interlaboratory study can be used to make an uncertainty statement as well. The relationship between validation and uncertainty statement is not clear for many analysts and there is a need to show how the existing data, derived during validation, can be used in practice. Eight laboratories participated in this interlaboratory study. The set-up allowed the determination of the repeatability variance, s(2)r and the between-laboratory variance, s(2)L. Combination of s(2)r and s(2)L results in the reproducibility variance s(2)R. It has been shown how these data can be used in future by a single laboratory that wants to make an uncertainty statement concerning the same analysis.  相似文献   

5.
6.
A rapid and simple multi-residue procedure is described for assaying eleven quinolones (cinoxacin, ciprofloxacin, danofloxacin, difloxacin, enrofloxacin, flumequine, marbofloxacin, nalidixic acid, norfloxacin, oxolinic acid and sarafloxacin) in feeds at sub-additive levels (1–5 mg kg−1). Five grams of sample were extracted by a metaphosphoric acid/acetonitrile mixture (70/30, v/v) and purified onto OASIS HLB cartridges. The determination was achieved by liquid chromatography (LC) using a GEMINI C18 analytical column both with fluorescence detection (FD) and photodiode-array (DAD). Limits of detection for each drug were in the range 0.04–0.8 mg kg−1. Above the limit of quantification (LOQ), in poultry feed the recoveries were from 69 to 98% with relative standard deviations less than or equal 10%. Finally the measurement uncertainty was estimated using the bottom-up approach.  相似文献   

7.
 Every analytical result should be expressed with some indication of its quality. The uncertainty as defined by Eurachem ("parameter associated with the result of a measurement that characterises the dispersion of the values that could reasonably be attributed to the, . . ., quantity subjected to measurement") is a good tool to accomplish this goal in quantitative analysis. Eurachem has produced a guide to the estimation of the uncertainty attached to an analytical result. Indeed, the estimation of the total uncertainty by using uncertainty propagation laws is components-dependent. The estimation of some of those components is based on subjective criteria. The identification of the uncertainty sources and of their importance, for the same method, can vary from analyst to analyst. It is important to develop tools which will support each choice and approximation. In this work, the comparison of an estimated uncertainty with an experimentally assessed one, through a variance test, is performed. This approach is applied to the determination by atomic absorption of manganese in digested samples of lettuce leaves. The total uncertainty estimation is calculated assuming 100% digestion efficiency with negligible uncertainty. This assumption was tested. Received: 3 November 1997 · Accepted: 2 January 1998  相似文献   

8.
This paper is aimed at reporting a full validation of a Cold Vapour Atomic Absorption Spectrometry (CVAAS) method for mercury determination in fishery products. Method precision, trueness, limit of detection and limit of quantification are evaluated. The uncertainty of measurement is estimated following the bottom-up approach in conjunction with the validation data as suggested for complex analysis. The precision is evaluated using a pooled relative standard deviation and the recovery is added to the measurement uncertainty budget. Uncertainties of weight of sample, dilution factor, calibration, work solution and analyte amount are also assessed. The most relevant uncertainty sources result those associated to amount of mercury determined in the final sample solution, to method precision and to recovery. The relative contributions have different weights according to the analyst decision regarding recovery correction of results. In conclusion, the adopted CVAAS method fully complies with EU requirements. Presented at AOAC Europe/Eurachem Symposium March 2005, Brussels, Belgium  相似文献   

9.
Summary A simple, rapid and accurate, routine-HPLC method is described for simultaneous determination of acetaminophen, caffeine and chlorpheniramine maleate in a new tablet formulation Chromatographic separation of the three pharmaceuticals was achieved on a Hypersil CN column (150×5.0 mm, 5 μm) using a mobile phase comprising a mixture of acetonitrile, an ion-pair solution and tetrahydrofuran (13:14:87, v/v,pH4.5). The flow-rate was changed from 1.0 mL min−1 (in 0≈7.5 min) to 1.8 mL min−1 (after 3.5 min). was complete in <10 min. The method was validated for system suitability, linearity, accuracy, precision, limits of detection and quantitation, and robustness. Linearity, accuracy and precision were found to be acceptable over the ranges 31.6≈315.8 μg mL−1 for acetaminophen, 9.5≈94.6 μg mL−1 for caffeine and 1.4≈13.8 μg mL−1 for chlorpheniramine maleate.  相似文献   

10.
This paper describes the validation of a HS-GC-FID method (based on the Pharmacopeia’s method) for the determination of ethanol content in tablets. A general view of the procedure development/optimization process is presented. The main point of this study is the calculation of validation parameters. Selectivity of the method was determined. Linearity (r > 0.997) was observed in the range from 9.0 to 3,040 μg of ethanol per sample (because the mass of the tablets used was around 200 mg, this corresponds to 45–15,200 μg g−1). The method showed good recoveries (average 99.0%), and a relative standard deviation for repeatability and intermediate precision of 4.5% and 5.5% respectively. The limit of detection was calculated to be 3.0 μg of ethanol per sample (15 μg g−1). The uncertainty budget was done according to the "Guide to the Expression of Uncertainty in Measurement" (GUM)[1], and a relative expanded uncertainty was estimated as 4.8%.  相似文献   

11.
A collaborative study applying an enantiomeric liquid chromatographic (LC) method was carried out to determine the content of the enantiomeric impurity R-timolol and other related substances in three different S-timolol maleate samples. Eight laboratories, all located in Europe, participated in the study. The quantitative results obtained were used to estimate the uncertainty on the content of the different impurities. For that purpose, a set-up was adapted from the ISO guidelines 5725-2, which allowed the estimation of the different variances, i.e. the between-laboratories (), the between-days () and the between-replicates (). The variances of repeatability () and reproducibility () were then calculated using the equations and . For the timolol impurities, it was found that the estimated uncertainty seem to be concentration-dependent. Since the LC method which combines the compendial ones for enantiomeric purity and related substances testing was applied to evaluate uncertainty in this collaborative study, it was shown how a laboratory can evaluate the uncertainty of its results when applying the method in the future.  相似文献   

12.
Rapid and practical extraction methods were developed using dichloromethane and ethyl acetate for the routine determination of 16 organochlorine pesticide residues and applied to approximately 30 fresh vegetables (tomato, cucumber and pepper) by using GC-ECD. The procedures were validated. Measurement uncertainties were calculated by applying bottom-up approach. The average recoveries obtained for each pesticide ranged between 65 and 102% at three fortification levels. The uncertainties of the analytical methods were lower than 21 and 16% with and without recovery correction, respectively. The calculated limits of detection and quantification were typically less than 1 ng g−1 that were much lower than the maximum residue levels.  相似文献   

13.
A stability-indicating reversed-phase high-performance liquid chromatography (LC) method was developed and validated for the determination of hydrochlorothiazide in an oral suspension. Isocratic chromatography was performed on a C18 column with 0.1 M sodium phosphate buffer pH 3.0/acetonitrile (70:30 v/v) as mobile phase, at a flow rate of 1.3 mL min−1, and UV detection at 254 nm. The method was linear (r 2 = 0.9998), accurate (mean recovery = 100.3%), and precise (RSD <2%). It was also validated for specificity and robustness. The method was successfully applied for the quality control analysis of a new pharmaceutical formulation of HCTZ for pediatric use.  相似文献   

14.
《Analytica chimica acta》2004,512(1):103-110
The molecular weight of biopolymers such as peptides or proteins is vital information for understanding their physical/chemical properties. The matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) and size-exclusion chromotography-multi-angle laser light scattering (SEC-MALLS) techniques each with its advantages and limitations were used for molecular weight determination of the SPf66 peptide. The precision of each method was studied using a two-factor fully-nested design with all the analyses performed by the same operator on a single instrument. The overall precision corresponded to the time-different intermediate precision (i.e. time and repeatability conditions). In the case of SEC-MALLS, all potential uncertainty components were carefully evaluated in an Ishikawa diagram, then included and mathematically combined with the uncertainty arising from the accuracy assessment to provide the overall uncertainty. In this case, the refractive-index increment with solute concentration value (dn/dc) provided the most significant contribution to the combined uncertainty. A method for its quantitation is proposed. The accuracy of method B (SEC-MALLS) against reference method A (MALDI-TOF-MS) was assessed using the interval testing hypothesis to limit the risk of unacceptable bias. The results indicate that the bias of B is higher than the limit established at 5%, and is therefore not traceable to A under the studied conditions.  相似文献   

15.
Three novel LC-UV methods for the determination of pentamidine (PTMD) and two of its new analogs in rat plasma are described. The chromatographic conditions (wavelength, acetonitrile percentage in the mobile phase, internal standard) were optimized to have an efficient selectivity. A pre-step of extraction was simultaneously developed for each compound. For PTMD, a solid phase extraction (SPE) with Oasis® HLB cartridges was selected, while for the analogs we used protein precipitation with acetonitrile. SPE for PTMD gave excellent results in terms of extraction yield (99.7 ± 2.8) whereas the recoveries for the analogs were not so high but were reproducible as well (64.6 ± 2.6 and 36.8 ± 1.6 for analog 1 and 2, respectively).By means of a recent strategy based on accuracy profiles (β-expectation tolerance interval), the methods were successfully validated. β was fixed at 95% and the acceptability limits at ±15% as recommended by the FDA. The method was successfully validated for PTMD (29.6-586.54 ng/mL), analog 1 (74.23-742.3 ng/mL) and analog 2 (178.12-890.6 ng/mL). The first concentration level tested was considered as the LLOQ (lower limit of quantification) for PTMD and analog 1 whereas for analog 2, the LLOQ was not the first level tested and was raised to 178.12 ng/mL.  相似文献   

16.
The aim of this work was to develop and validate a simple and sensitive analytical method for determining enrofloxacin (EFX) and ciprofloxacin (CFX) in equine plasma and endometrial tissue samples, as a precursor to conducting pharmacokinetic/pharmacodynamic studies on equine endometritis This was achieved in the form of a liquid chromatographic procedure, with fluorometric detection, which also gave good separation of other fluoroquinolones including marbofloxacin (MFX), danofloxacin (DFX) and ofloxacin (OFX). Analytes were separated on a C18 reversed phase column using an acidified mobile phase. The exact composition of the mobile phase differed for plasma (16% acetonitrile:methanol [13:1,v/v] 84% water containing 0.4% triethylamine and 0.4% phosphoric acid [35%]) and endometrial tissue (14% acetonitrile, 86% water, without methanol) samples. EFX and CFX were both detected at excitation and emission wavelengths of 294 and 500 nm, respectively. Prior to chromatography, EFX and CFX were purified by solid phase extraction from plasma, and a combination of solvent/solid phase extraction from endometrial tissue.

Mean absolute recoveries for EFX and CFX from plasma were 94.1 and 78.0%, respectively, and from endometrial tissue, 78.0 and 57.8%, respectively, with a percentage residual standard deviation (%R.S.D.) <10% in each case. Mean relative recoveries for EFX and CFX from plasma were 91.3 and 119.4%, respectively, and from endometrial tissue, 80.2 and 108.0%, respectively, with a %R.S.D. <20% in each case.

Standard curves constructed using blank plasma and endometrial tissue samples, spiked with authentic EFX and CFX in the ranges 0.005–10.0 μg mL−1 and 0.05–10.0 μg g−1, respectively, all showed acceptable linearity with correlation coefficients, r2 ≥ 0.977. Mean intra- and inter-day precision (expressed as %R.S.D.) was <6 and <13%, respectively, with an associated accuracy (expressed as percentage relative error, %R.E.) of <20% for both analytes in both matrices. Acceptable precision and accuracy was also demonstrated at the pre-assigned LOQs of 0.005 μg mL−1 for both EFX and CFX in plasma, and 0.05 μg g−1 for both drugs in endometrial tissue. EFX and CFX were stable in both plasma and endometrial tissue for at least 60 days at −20 °C.  相似文献   


17.
《Analytica chimica acta》2004,506(1):71-80
We describe an estimation of measurement uncertainty calculated by the “bottom-up” approach for the determination of the oestrogenic compound nonylphenol in treated water samples by solid-phase extraction (SPE) and solid-phase microextraction (SPME) procedures and GC/MS detection. The results were compared and the different contributions to the uncertainty were evaluated. A study of the linear range was established and validation was performed for both methods using statistical analysis of several indicative parameters. In terms of validation data, precision (R.S.D. values <20%) and trueness (relative error <11%) were obtained for both methods under day-to-day conditions. The results of the estimation of measurement uncertainty obtained for both methods for concentrations higher than 1 μg/l have demonstrated that the time-consuming SPE method has a lower relative uncertainty (32%) than the SPME method (42.8%). The chromatographic uncertainty value was the main factor in the SPME method whereas the recovery factor (used to calculate the concentration) was the main contribution to uncertainty in the SPE method.  相似文献   

18.
A sensitive and rapid liquid chromatographic (LC) method for the simultaneous determination of testosterone (T) and epitestosterone (E) in human urine samples has been developed and elaborated. The ratio of the both steroids (T/E) in human urine is a widely used as doping control indicator. A sample pretreatment by solid-phase extraction (SPE) after hydrolysis using 36% hydrochloric acid for determination of total level of T has been applied. Unconjugated (free) form of the both androgens were determined without hydrolysis steps, what makes novelty of the method, because simplifies the proposed procedure. In turn, the measurements of urinary free T and E provided the diagnostic information for excess adrenal production of steroids. The proposed LC assay was evaluated by analyzing a series of urine samples containing T, E and methyltestosterone (MT) as internal standard at the range of concentration 2-300 ng−1 mL of both analyzed hormones. The proposed method was fully validated for specificity, linearity, limits of detection and quantitation, precision and trueness according to the current requirements concerning analytical methods. Interestingly, the developed LC method allows to obtain a sensitive enhancement with respect to UV detection with the quantitation limit for T and E equaled 2 ng mL−1. The method was selective and reliable for identity and enable to detect changes of endogenous levels of T and E in urine independently of fluctuations characteristic for both analyzed endogenous hormone level in plasma.  相似文献   

19.
Golabi N  Tajerzadeh H  Ghassempour A 《Talanta》2003,59(6):1089-1094
A simple and highly selective isocratic reverse-phase high performance liquid chromatography (RP-LC) method at room temperature is developed in order to determination of Cyclosporine A (CyA) and its major metabolite (AM1) in serum samples of kidney transplanted patients. The method uses a phenyl column stationary phase, acetonitrile–water–methanol 47:50:3 as mobile phase and 215 nm detector wavelength, at room temperature. The solid phase extraction procedure using cyano disposable extraction column was carried out to separtate the CyA and AM1 with recovery 99±6 and 98±10, respectively. A linear correlation was found at the range of 40–1000 ng ml−1 for CyA and 25–500 ng ml−1 for AM1. The average intra and inter-day variations were 5.03 and 7.89% for CyA, 5.92 and 8.12% for AM1, respectively. The detection limit of 20 ng ml−1 was found for CyA and 12.5 ng ml−1 for AM1. Also, the clinical application of the method using serum concentration against time profile from kidney transplantated patients is reported.  相似文献   

20.
Previous publications investigated different data treatment strategies for quantification of volatile suspected allergens by GC/MS. This publication presents the validation results obtained on "ready to inject" samples under reproducibility conditions following inter-laboratory ring-testing. The approach is based on the monitoring of three selected ions per analyte using two different GC capillary columns. To aid the analysts a decisional tree is used for guidance during the interpretation of the analytical results. The method is evaluated using a fragrance oil concentrate spiked with all suspected allergens to mimic the difficulty of a real sample extract or perfume oil. At the concentrations of 10 and 100mg/kg, imposed by Directive 76/768/EEC for labeling of leave-on and rinse-off cosmetics, the mean bias is +14% and -4%, respectively. The method is linear for all analytes, and the prediction intervals for each analyte have been determined. To speed up the analyst's task, an automated data treatment is also proposed. The method mean bias is slightly shifted towards negative values, but the method prediction intervals are close to that resulting from the decisional tree.  相似文献   