共查询到20条相似文献,搜索用时 15 毫秒
1.
The robustness testing of a normal-phase liquid chromatographic (LC) method for the determination of R-timolol and other related substances in S-timolol maleate was performed applying a two-level Plackett-Burman design. Two qualitative and five quantitative factors were examined. Two types of responses were considered, qualitative, i.e. chromatographic performance criteria, and quantitative ones. The latter were taken into account to determine if the analytical procedure was robust. The quantitative responses were the contents of R-timolol in two S-timolol maleate samples. Even though some significant factor effects were observed on the qualitative responses, the R-timolol contents were not significantly different from those observed at nominal conditions, which demonstrated the robustness of the procedure.Since the experiments of the Plackett-Burman design can be assimilated to laboratories in an interlaboratory study, uncertainty can be evaluated using the robustness test data. The robustness test was set-up in such a way that the required variances could be estimated. It was shown that the robustness set-up allows estimating the reproducibility uncertainty without performing an interlaboratory study. 相似文献
2.
Marini RD Groom C Doucet FR Hawari J Bitar Y Holzgrabe U Gotti R Schappler J Rudaz S Veuthey JL Mol R Somsen GW de Jong GJ Ha PT Zhang J Van Schepdael A Hoogmartens J Briône W Ceccato A Boulanger B Mangelings D Vander Heyden Y Van Ael W Jimidar I Pedrini M Servais AC Fillet M Crommen J Rozet E Hubert P 《Electrophoresis》2006,27(12):2386-2399
3.
Dunge Ashenafi Ann Verbeek Jos Hoogmartens Erwin Adams 《Journal of separation science》2009,32(11):1823-1830
A robust, precise, sensitive, linear, and simple RP LC method coupled with UV for the determination of emtricitabine or 2′,3′‐dideoxy‐5‐fluoro‐3′‐thiacytidine (FTC) and its related substances is described. The method uses an RP C18 column (25 cm×4.6 mm i.d.), 5 μm kept at a temperature of 35°C. The mobile phases for gradient elution consist of ACN, phosphate buffer (pH 4.4), and water. The flow rate is 1.0 mL/min and UV detection is performed at 280 nm. A system suitability test (SST) was developed to verify the adequate performance of the chromatographic system. The developed method was further validated with respect to robustness, precision, sensitivity, and linearity. A central composite design was applied to examine the robustness of the method. The method shows good precision, sensitivity, linearity, and robustness. Three commercial FTC samples were examined using this method. This method is suitable to be used for the determination of related substances and assay of FTC. 相似文献
4.
M. Naceur Haouet M. Serena Altissimi Marisa Framboas Roberta Galarini 《Accreditation and quality assurance》2006,11(1-2):23-28
The aim of this paper is to compare the performance parameters of the Volhard method for chlorides determination obtained
applying the bottom-up approach with those experimentally achieved. The method precision, trueness, detection and quantification
limits and ruggedness are determined analysing various foods with different chloride contents. Otherwise, the measurement
uncertainty is assessed applying the bottom-up approach using only pen and paper. The comparison between the performances
established with both methods shows the validity of the metrological approach for volumetric procedures.
Presented at AOAC Europe/Eurachem Symposium March 2005, Brussels, Belgium 相似文献
5.
Dalmora SL Sangoi Mda S da Silva LM Macedo RO Barth T 《Journal of separation science》2008,31(1):169-176
A CZE method was developed and validated for the analysis of etoricoxib in pharmaceutical dosage forms, using prilocaine as an internal standard. The CZE method was carried out on a fused-silica capillary (50 microm id, effective length 40 cm). The BGE consisted of 25 mM tris-phosphate solution at pH 2.5. The capillary temperature was maintained at 35 degrees C, the applied voltage was 25 kV, the injection was performed using the pressure mode at 50 mbar for 5 s, with detection at 234 nm using a photodiode array detector. The method was linear in the range of 2-150 microg/mL (r(2) = 0.9999). The specificity and stability-indicating capability were proven through the degradation studies and showing also that there was no interference of the excipients of the formulation. The accuracy was 99.49% with RSD of 0.66%. The limits of quantitation and detection were 2 and 0.58 microg/mL, respectively. Moreover, method validation demonstrated acceptable results for the precision, sensitivity, and robustness. The proposed method was successfully applied for the quantitative analysis of etoricoxib pharmaceutical formulations, and the results compared to the HPLC and LC-MS/MS methods, showing nonsignificant difference (p >0.05). 相似文献
6.
Dehouck P Vander Heyden Y Smeyers-Verbeke J Massart DL Marini RD Chiap P Hubert P Crommen J Van de Wauw W De Beer J Cox R Mathieu G Reepmeyer JC Voigt B Estevenon O Nicolas A Van Schepdael A Adams E Hoogmartens J 《Journal of chromatography. A》2003,1010(1):63-74
Erythromycin is a mixture of macrolide antibiotics produced by Saccharopolyspora erythreas during fermentation. A new method for the analysis of erythromycin by liquid chromatography has previously been developed. It makes use of an Astec C18 polymeric column. After validation in one laboratory, the method was now validated in an interlaboratory study. Validation studies are commonly used to test the fitness of the analytical method prior to its use for routine quality testing. The data derived in the interlaboratory study can be used to make an uncertainty statement as well. The relationship between validation and uncertainty statement is not clear for many analysts and there is a need to show how the existing data, derived during validation, can be used in practice. Eight laboratories participated in this interlaboratory study. The set-up allowed the determination of the repeatability variance, s(2)r and the between-laboratory variance, s(2)L. Combination of s(2)r and s(2)L results in the reproducibility variance s(2)R. It has been shown how these data can be used in future by a single laboratory that wants to make an uncertainty statement concerning the same analysis. 相似文献
7.
8.
Roberta Galarini Laura FioroniFederico Angelucci Gloria R. TovoElisa Cristofani 《Journal of chromatography. A》2009,1216(46):8158-8164
A rapid and simple multi-residue procedure is described for assaying eleven quinolones (cinoxacin, ciprofloxacin, danofloxacin, difloxacin, enrofloxacin, flumequine, marbofloxacin, nalidixic acid, norfloxacin, oxolinic acid and sarafloxacin) in feeds at sub-additive levels (1–5 mg kg−1). Five grams of sample were extracted by a metaphosphoric acid/acetonitrile mixture (70/30, v/v) and purified onto OASIS HLB cartridges. The determination was achieved by liquid chromatography (LC) using a GEMINI C18 analytical column both with fluorescence detection (FD) and photodiode-array (DAD). Limits of detection for each drug were in the range 0.04–0.8 mg kg−1. Above the limit of quantification (LOQ), in poultry feed the recoveries were from 69 to 98% with relative standard deviations less than or equal 10%. Finally the measurement uncertainty was estimated using the bottom-up approach. 相似文献
9.
R. J. N. Bettencourt da Silva M. Filomena G. F. C. Camões João Seabra e Barros 《Accreditation and quality assurance》1998,3(4):155-160
Every analytical result should be expressed with some indication of its quality. The uncertainty as defined by Eurachem ("parameter
associated with the result of a measurement that characterises the dispersion of the values that could reasonably be attributed
to the, . . ., quantity subjected to measurement") is a good tool to accomplish this goal in quantitative analysis. Eurachem
has produced a guide to the estimation of the uncertainty attached to an analytical result. Indeed, the estimation of the
total uncertainty by using uncertainty propagation laws is components-dependent. The estimation of some of those components
is based on subjective criteria. The identification of the uncertainty sources and of their importance, for the same method,
can vary from analyst to analyst. It is important to develop tools which will support each choice and approximation. In this
work, the comparison of an estimated uncertainty with an experimentally assessed one, through a variance test, is performed.
This approach is applied to the determination by atomic absorption of manganese in digested samples of lettuce leaves. The
total uncertainty estimation is calculated assuming 100% digestion efficiency with negligible uncertainty. This assumption
was tested.
Received: 3 November 1997 · Accepted: 2 January 1998 相似文献
10.
M. Naceur Haouet Giannina Chessa Laura Fioroni Roberta Galarini 《Accreditation and quality assurance》2006,11(1-2):17-22
This paper is aimed at reporting a full validation of a Cold Vapour Atomic Absorption Spectrometry (CVAAS) method for mercury
determination in fishery products. Method precision, trueness, limit of detection and limit of quantification are evaluated.
The uncertainty of measurement is estimated following the bottom-up approach in conjunction with the validation data as suggested
for complex analysis.
The precision is evaluated using a pooled relative standard deviation and the recovery is added to the measurement uncertainty
budget. Uncertainties of weight of sample, dilution factor, calibration, work solution and analyte amount are also assessed.
The most relevant uncertainty sources result those associated to amount of mercury determined in the final sample solution,
to method precision and to recovery. The relative contributions have different weights according to the analyst decision regarding
recovery correction of results. In conclusion, the adopted CVAAS method fully complies with EU requirements.
Presented at AOAC Europe/Eurachem Symposium March 2005, Brussels, Belgium 相似文献
11.
Summary A simple, rapid and accurate, routine-HPLC method is described for simultaneous determination of acetaminophen, caffeine and
chlorpheniramine maleate in a new tablet formulation Chromatographic separation of the three pharmaceuticals was achieved
on a Hypersil CN column (150×5.0 mm, 5 μm) using a mobile phase comprising a mixture of acetonitrile, an ion-pair solution
and tetrahydrofuran (13:14:87, v/v,pH4.5). The flow-rate was changed from 1.0 mL min−1 (in 0≈7.5 min) to 1.8 mL min−1 (after 3.5 min). was complete in <10 min. The method was validated for system suitability, linearity, accuracy, precision,
limits of detection and quantitation, and robustness. Linearity, accuracy and precision were found to be acceptable over the
ranges 31.6≈315.8 μg mL−1 for acetaminophen, 9.5≈94.6 μg mL−1 for caffeine and 1.4≈13.8 μg mL−1 for chlorpheniramine maleate. 相似文献
12.
Magdalena Michulec Piotr Konieczka Jacek Namieśnik 《Accreditation and quality assurance》2007,12(5):257-262
This paper describes the validation of a HS-GC-FID method (based on the Pharmacopeia’s method) for the determination of ethanol
content in tablets. A general view of the procedure development/optimization process is presented. The main point of this
study is the calculation of validation parameters. Selectivity of the method was determined. Linearity (r > 0.997) was observed in the range from 9.0 to 3,040 μg of ethanol per sample (because the mass of the tablets used was around
200 mg, this corresponds to 45–15,200 μg g−1). The method showed good recoveries (average 99.0%), and a relative standard deviation for repeatability and intermediate
precision of 4.5% and 5.5% respectively. The limit of detection was calculated to be 3.0 μg of ethanol per sample (15 μg g−1). The uncertainty budget was done according to the "Guide to the Expression of Uncertainty in Measurement" (GUM)[1], and a relative expanded uncertainty was estimated as 4.8%. 相似文献
13.
Dunge Ashenafi Varalaxmi Chintam Daisy van Veghel Sanja Dragovic Jos Hoogmartens Erwin Adams 《Journal of separation science》2010,33(12):1708-1716
The present study describes the development and validation of a selective liquid chromatographic (LC) method for the analysis of tenofovir disoproxil fumarate (TDF) and its related substances. The gradient method uses a base deactivated C18 column (Hypersil BDS column; 25 cm×4.6 mm I.D.) maintained at a temperature of 30°C. The mobile phases consist of acetonitrile, tetrabutylammonium/phosphate buffer pH 6.0 and water: (A; 2:20:78 v/v/v) and (B; 65:20:15 v/v/v). The flow rate is 1.0 mL/min and UV detection is performed at 260 nm. Good separation of TDF and 21 impurities was achieved. A system suitability test (SST) to check the quality of separation is also specified. The developed method was further validated with respect to robustness, precision, sensitivity and linearity. The method is proved to be robust, precise, sensitive and linear between 0.1 μg/mL and 0.15 mg/mL. The limit of detection and limit of quantification are 0.03 and 0.1 μg/mL, respectively. The method was successfully applied to the quantification of related substances and assay of commercial TDF samples (bulk substances and tablets). 相似文献
14.
R.D. Marini N. Matthijs J. Smeyers-Verbeke J. Hoogmartens A. Ceccato Ph. Goedert C. Herbots R. Herráez-Hernández P. Campíns-falcó J. De Beer P. Chiap Ph. Hubert 《Analytica chimica acta》2005,546(2):182-192
A collaborative study applying an enantiomeric liquid chromatographic (LC) method was carried out to determine the content of the enantiomeric impurity R-timolol and other related substances in three different S-timolol maleate samples. Eight laboratories, all located in Europe, participated in the study. The quantitative results obtained were used to estimate the uncertainty on the content of the different impurities. For that purpose, a set-up was adapted from the ISO guidelines 5725-2, which allowed the estimation of the different variances, i.e. the between-laboratories (), the between-days () and the between-replicates (). The variances of repeatability () and reproducibility () were then calculated using the equations and . For the timolol impurities, it was found that the estimated uncertainty seem to be concentration-dependent. Since the LC method which combines the compendial ones for enantiomeric purity and related substances testing was applied to evaluate uncertainty in this collaborative study, it was shown how a laboratory can evaluate the uncertainty of its results when applying the method in the future. 相似文献
15.
A rapid and reliable high‐performance liquid chromatographic method for resolution of enantiomers of adrafinil [(±)‐ADL], a novel vigilance promoting agent, and its synthetic intermediates was developed. The separation was carried out on a Chiralcel OJ‐H using n‐hexane–ethanol (62:38 v/v) as a mobile phase. The detection was carried out at 225 nm using a photodiode array (PDA) detector. The optical rotation and order of elution of enantiomers were assigned. The method is suitable not only for process development of ADL but also for quality assurance of bulk drugs and pharmaceuticals. Copyright © 2010 John Wiley & Sons, Ltd. 相似文献
16.
Yenisoy-Karakaş S 《Analytica chimica acta》2006,571(2):298-307
Rapid and practical extraction methods were developed using dichloromethane and ethyl acetate for the routine determination of 16 organochlorine pesticide residues and applied to approximately 30 fresh vegetables (tomato, cucumber and pepper) by using GC-ECD. The procedures were validated. Measurement uncertainties were calculated by applying bottom-up approach. The average recoveries obtained for each pesticide ranged between 65 and 102% at three fortification levels. The uncertainties of the analytical methods were lower than 21 and 16% with and without recovery correction, respectively. The calculated limits of detection and quantification were typically less than 1 ng g−1 that were much lower than the maximum residue levels. 相似文献
17.
Monika Piazzon Tagliari Hellen Karine Stulzer Fabio Seigi Murakami Gislaine Kuminek Bruno Valente Paulo Renato Oliveira Marcos Antonio Segatto Silva 《Chromatographia》2008,67(7-8):647-652
A stability-indicating reversed-phase high-performance liquid chromatography (LC) method was developed and validated for the
determination of hydrochlorothiazide in an oral suspension. Isocratic chromatography was performed on a C18 column with 0.1 M sodium phosphate buffer pH 3.0/acetonitrile (70:30 v/v) as mobile phase, at a flow rate of 1.3 mL min−1, and UV detection at 254 nm. The method was linear (r
2 = 0.9998), accurate (mean recovery = 100.3%), and precise (RSD <2%). It was also validated for specificity and robustness.
The method was successfully applied for the quality control analysis of a new pharmaceutical formulation of HCTZ for pediatric
use. 相似文献
18.
Ascorbic acid (AA), also known as vitamin C, is a very popular skin-whitening agent used in cosmetics. However, the use of AA (and also its sodium or magnesium salts) in cosmetic products is limited owing to its labile oxidative properties. In order to avoid its early degradation, different derivatives have been designed, such as ascorbyl phosphate (APH; as magnesium or sodium salts) and ascorbyl palmitate (AP), and more recently the ascorbyl glucoside (AG). Bearing in mind that all these chemicals in skin-whitening cosmetic products must be determined in order to control the efficacy of such products, this paper focuses on developing a wide-ranging LC analytical method able to determine the above-mentioned compounds simultaneously in cosmetic products. The chromatographic variables were studied and selected in order to achieve the total separation and subsequent determination of all the analytes involved. Thus, an octadecylsilica (C(18)) stationary phase and a mobile phase gradient of ethanol: 50 mM phosphate buffer at different pHs (containing 0.1 M NaCl) were used. Detection was carried out with a UV/visible spectrometry detector set at different wavelengths. The LOD ranged from 2 to 6 microg/mL depending on the analyte. The proposed method was validated by analysing a laboratory-made and six commercial skin-whitening cosmetic samples. The method allows any mixture of the four skin-whitening agents studied to be both separated at good resolution and determined without interferences from samples, and moreover it does not require the use of either highly toxic organic solvents or hazardous chemicals. 相似文献
19.
《Analytica chimica acta》2004,512(1):103-110
The molecular weight of biopolymers such as peptides or proteins is vital information for understanding their physical/chemical properties. The matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) and size-exclusion chromotography-multi-angle laser light scattering (SEC-MALLS) techniques each with its advantages and limitations were used for molecular weight determination of the SPf66 peptide. The precision of each method was studied using a two-factor fully-nested design with all the analyses performed by the same operator on a single instrument. The overall precision corresponded to the time-different intermediate precision (i.e. time and repeatability conditions). In the case of SEC-MALLS, all potential uncertainty components were carefully evaluated in an Ishikawa diagram, then included and mathematically combined with the uncertainty arising from the accuracy assessment to provide the overall uncertainty. In this case, the refractive-index increment with solute concentration value (dn/dc) provided the most significant contribution to the combined uncertainty. A method for its quantitation is proposed. The accuracy of method B (SEC-MALLS) against reference method A (MALDI-TOF-MS) was assessed using the interval testing hypothesis to limit the risk of unacceptable bias. The results indicate that the bias of B is higher than the limit established at 5%, and is therefore not traceable to A under the studied conditions. 相似文献
20.
S. HambÿeD. Stanicki J.-M. ColetE.M. Aliouat J.J. Vanden EyndeB. Blankert 《Talanta》2011,83(3):832-839
Three novel LC-UV methods for the determination of pentamidine (PTMD) and two of its new analogs in rat plasma are described. The chromatographic conditions (wavelength, acetonitrile percentage in the mobile phase, internal standard) were optimized to have an efficient selectivity. A pre-step of extraction was simultaneously developed for each compound. For PTMD, a solid phase extraction (SPE) with Oasis® HLB cartridges was selected, while for the analogs we used protein precipitation with acetonitrile. SPE for PTMD gave excellent results in terms of extraction yield (99.7 ± 2.8) whereas the recoveries for the analogs were not so high but were reproducible as well (64.6 ± 2.6 and 36.8 ± 1.6 for analog 1 and 2, respectively).By means of a recent strategy based on accuracy profiles (β-expectation tolerance interval), the methods were successfully validated. β was fixed at 95% and the acceptability limits at ±15% as recommended by the FDA. The method was successfully validated for PTMD (29.6-586.54 ng/mL), analog 1 (74.23-742.3 ng/mL) and analog 2 (178.12-890.6 ng/mL). The first concentration level tested was considered as the LLOQ (lower limit of quantification) for PTMD and analog 1 whereas for analog 2, the LLOQ was not the first level tested and was raised to 178.12 ng/mL. 相似文献