首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The electroanalysis of -penicillamine in 0.1 phosphate buffer (pH 7) was studied at a boron-doped diamond thin film (BDD) electrode using cyclic voltammetry as a function of concentration of analyte and pH of analyte solution. Comparison experiments were performing using a glassy carbon (GC) electrode. The BDD electrode exhibited a well-resolved and irreversible oxidation voltammogram, but the GC electrode provided only an ill-defined response. The BDD electrode provided a linear dynamic range from 0.5 to 10 mM and a detection limit of 25 μM (S/B≥3) in voltammetric measurement. It was also found that the peak potentials were decreased when the pH of the analyte solution was increased. In addition, penicillamine has been studied by hydrodynamic voltammetry and flow injection analysis with amperometric detection using the BDD electrode. The flow injection analysis results at the diamond electrode indicated a linear dynamic range from 0.5 to 50 μM and a detection limit of 10 nM (S/N≈4). The proposed method was applied to determine -penicillamine in dosage form (capsules), the results obtained in the recovery study (255±2.50 mg per tablet) were comparable to those labeled (250 mg per tablet).  相似文献   

2.
Sulfonamides (SAs) were electrochemically investigated using cyclic voltammetry at a boron-doped diamond (BDD) electrode. Comparison experiments were carried out using a glassy carbon electrode. The BDD electrode provided well-resolved oxidation, irreversible cyclic voltammograms and higher current signals when compared to the glassy carbon electrode. Results obtained from using the BDD electrode in a flow injection system coupled with amperometric detection were illustrated. The optimum potential from a hydrodynamic voltammogram was found to be 1100 mV versus Ag/AgCl, which was chosen for the HPLC-amperometric system. Excellent results of linear range and detection limit were obtained. This method was also used for determination of sulfonamides in egg samples. The standard solutions of 5, 10, and 15 ppm were spiked in a real sample, and percentage of recoveries was found to be between 90.0 and 107.7.  相似文献   

3.
A method using flow injection (FI) with amperometric detection at anodized boron-doped diamond (BDD) thin films has been developed and applied for the determination of tetracycline antibiotics (tetracycline, chlortetracycline, oxytetracycline and doxycycline). The electrochemical oxidation of the tetracycline antibiotics was studied at various carbon electrodes including glassy carbon (GC), as-deposited BDD and anodized BDD electrodes using cyclic voltammetry. The anodized BDD electrode exhibited well-defined irreversible cyclic voltammograms for the oxidation of tetracycline antibiotics with the highest current signals compared to the as-deposited BDD and glassy carbon electrodes. Low detection limit of 10 nM (signal-to-noise RATIO = 3) was achieved for each drug when using flow injection analysis with amperometric detection at anodized BDD electrodes. Linear calibrations were obtained from 0.1 to 50 mM for tetracycline and 0.5–50 mM for chlortetracycline, oxytetracycline and doxycycline. The proposed method has been successfully applied to determine the tetracycline antibiotics in some drug formulations. The results obtained in percent found (99.50–103.01%) were comparable to dose labeled.  相似文献   

4.
Barek J  Jandová K  Pecková K  Zima J 《Talanta》2007,74(3):421-426
Voltammetric behavior of 2-aminobiphenyl, 3-aminobiphenyl, and 4-aminobiphenyl at a boron-doped nanocrystalline diamond film electrode was investigated using cyclic voltammetry and differential pulse voltammetry. Optimum conditions have been found for the determination of those genotoxic substances by differential pulse voltammetry at the above given electrode in the concentration range of 2 × 10−7 to 1 × 10−5 mol/L.  相似文献   

5.
A simple, fast and sensitive HPLC method with electrochemical detection employing boron-doped diamond electrode (BDD) for the determination of sildenafil (Viagra™), vardenafil (Levitra™) and their main metabolites, N-desmethyl sildenafil and N-desethyl vardenafil in human plasma is presented. The assay involved drug extraction by tert-butyl methyl ether and isocratic reversed-phase liquid chromatography with amperometric detection. Complete separation of all analytes was achieved within 12 min. The mobile phase consisted of 20 mM sodium dihydrogen phosphate with 40 mM sodium perchlorate/acetonitrile (70:30, v/v), pH 3.5. The electrode working potential was +1520 mV (vs. Pd/H2). Calibration curves were linear over the concentration range of 10–400 ng mL−1. Phloretin was used as an internal standard. The limits of detection (LOD) and quantification (LOQ) for the studied analytes were within the range of 2–4 ng mL−1 and 7.0–13.4 ng mL−1, respectively. The developed method was applied to human plasma samples spiked with analytes at therapeutic concentrations. The study confirms the method's suitability for both pharmacokinetic studies and therapeutic monitoring.  相似文献   

6.
The boron-doped diamond (BDD) presents attractive electrochemical sensing characteristics that are useful in analytical applications based on voltammetry and amperometry. It has a wide potential window in aqueous solutions enabling the quantification of the fungicide trifloxystrobin, measured at +1744 mV (versus Ag/AgCl), by square-wave anodic voltammetry in a Britton–Robinson (BR) buffer (0.04 mol L?1; pH 4.00)/acetonitrile 70/30% v/v. The activation of the electrode was made using galvanostatic chronopotentiometry and cyclic voltammetry (CV). The linear analyte addition curve, Ip (µA) = (1.0 × 10–1 ± 4.8 × 10–6) C (mol L?1) + (8.8 × 10–2 ± 1.1 × 10–3); R2 = 0.997, was obtained using amplitude of 40 mV, frequency of 30 Hz, step potential of 20 mV. The instrumental limit of detection (LOD) was 1.4 × 10–7 mol L?1 (0.058 mg L?1) and the dynamic linear range covered three decades (up to 1 × 10–5 mol L?1 or 4.1 mg L?1). The samples were analysed with recoveries about 80% in orange juice samples and from 92.4% to 104.0% in water samples. A study to evaluate potential interferences was made in the presence of other fungicides. Diagnostic studies indicated that oxidation of trifloxystrobin in aqueous medium at the surface of the BDD is irreversible, involving two steps, each one with two electrons. The UV degradation of trifloxystrobin was evaluated using the proposed electrochemical method and the kinetics of degradation established with half-life of 1.07 min.  相似文献   

7.
ABSTRACT

In the present study, a simple, cheap and sensitive electrochemical method based on a cathodically pretreated boron-doped diamond (CPT-BDD) electrode is described for the detection of triclosan with the cationic surfactant (cetyltrimethylammonium bromide, CTAB) media. The oxidation of triclosan was irreversible and exhibited an adsorption controlled process. The sensitivity of the adsorptive stripping voltammetric measurements was significantly improved with addition of CTAB. Using square-wave stripping mode, a linear response was obtained for triclosan determination in Britton-Robinson buffer solution at pH 9.0 containing 2.5 × 10?4 M CTAB at around + 0.67 V (vs. Ag/AgCl) (after 30 s accumulation at open-circuit condition). The method could be used in the range of 0.01–1.0 μg mL?1 (3.5 × 10?8–3.5 × 10?6 M), with a detection limit of 0.0023 μg mL?1 (7.9 × 10?9 M). The feasibility of the proposed method for the determination of triclosan in water samples was checked in spiked tap water.  相似文献   

8.
The electrochemical behavior of myoglobin (Mb) and hemoglobin (Hb) was investigated with a boron-doped diamond (BDD) electrode by cyclic voltammetry. In acetate buffer solutions, the oxygen reduction at the BDD electrode showed a very high overpotential while the reduction of Mb or Hb was observed in the more positive potential region. Owing to the electrocatalytic reaction of O2 and the participation of H+ following the electrochemical reduction of ferric proteins, the voltammetric responses for Mb and Hb on the BDD electrode in the negative going scans became remarkable in acidic buffer solutions in air. The peak current was linearly proportional to the concentration of Mb in the range 1×10−6–2×10−5 M or the concentration of Hb from 1×10−6 to 1×10−5 M.  相似文献   

9.
A self-assembled sensor based on a boron-doped diamond was investigated as a sensitive tool for voltammetric analysis of a member of a pyridine herbicide family - picloram. A cyclic voltammetry and a differential pulse voltammetry were applied for investigation of the voltammetric behaviour and quantification of this herbicide. Picloram yielded one well-developed irreversible oxidation signal at a very positive potential about +1.5 V vs. Ag/AgCl/3 mol L?1 KCl electrode in an acidic medium and 1 mol L?1 H2SO4 was chosen as a suitable supporting electrolyte. Operating parameters of differential pulse voltammetry were optimized and the proposed voltammetric method provided a high repeatability (a relative standard deviation of 20 repeated measurements at a concentration level of picloram of 50 µmol L?1 equaled to 2.58%), a linear concentration range from 2.5 to 90.9 µmol L?1 and a low limit of detection (LD = 1.64 µmol L?1). Practical usefulness of the ‘environmentally-green’ electrochemical sensor was verified by an analysis of spiked water samples with satisfactory recoveries.  相似文献   

10.
The electrochemical determination of iodide was studied at boron-doped diamond thin film electrodes (BDD) using cyclic voltammetry (CV) and flow-injection (FI) analysis, with amperometric detection. Cyclic voltammetry of iodide was conducted in a phosphate buffer pH 5. Experiments were performed using glassy carbon (GC) electrode as a comparison. Well-defined oxidation waves of the quasi-reversible cyclic voltammograms were observed at both electrodes. Voltammetric signal-to-background ratios (S/B) were comparable. However, the GC electrode gives much greater in the background current as usual. The potential sweep rate dependence exhibited that the peak current of iodide oxidation at 1 mM varied linearly (r2 = 0.998) with the square root of the scan rate, from 0.01 to 0.30 V s−1. This result indicates that the reaction is a diffusion-controlled process with negligible adsorption on BDD surface, at this iodide concentration. Results of the flow-injection analysis show a highly reproducible amperometric response. The linear working range was observed up to 200 μM (r2 = 0.999). The detection limit, as low as 0.01 μM (3σ of blank), was obtained. This method was successfully applied for quantification of iodide contents in nuclear emergency tablets.  相似文献   

11.
The electrochemical oxidation of ascorbic acid (AA) and serotonin (5-HT) at a boron-doped diamond (BDD) electrode modified with poly(N,N-dimethylaniline) (PDMA) has been studied. The oxidation potentials of 5-HT and AA overlapped after mixing of the two chemicals, due to interference of AA at the bare BDD electrode. However, after modifying the BDD electrode with a cationic polymer (PDMA), the oxidation peaks of 5-HT and AA were separated. PDMA-coated BDD electrodes can be used for simultaneous detection of these species.  相似文献   

12.
The electrochemical behavior of a glassy carbon electrode is investigated towards the oxidation of enrofloxacin in aqueous solutions of different pH. Two oxidative waves are observed at a potential range from 0.70 V to 1.20 V (vs. SCE), the intensity of each depending on the pH of the solution. These results are used to set the parameters for the amperometric detection of enrofloxacin in HPLC analysis. A wide linear range and high sensitivity are obtained for a calibration plot using the optimized experimental conditions. The limit of detection (S/N=3) obtained using those conditions is approximately 0.2 pmol. The applicability of the methodology is demonstrated in the analysis of enrofloxacin in fortified milk samples.  相似文献   

13.
A mediator-free glucose biosensor, termed a “third-generation biosensor,” was fabricated by immobilizing glucose oxidase (GOD) directly onto an oxidized boron-doped diamond (BDD) electrode. The surface of the oxidized BDD electrode possesses carboxyl groups (as shown by Raman spectra) which covalently cross-link with GOD through glutaraldehyde. Glucose was determined in the absence of a mediator used to transfer electrons between the electrode and enzyme. O2 has no effect on the electron transfer. The effects of experimental variables (applied potential, pH and cross-link time) were investigated in order to optimize the analytical performance of the amperometric detection method. The resulting biosensor exhibited fast amperometric response (less than 5 s) to glucose. The biosensor provided a linear response to glucose over the range 6.67×10−5 to 2×10−3 mol/L, with a detection limit of 2.31×10−5 mol/L. The lifetime, reproducibility and measurement repeatability were evaluated and satisfactory results were obtained.  相似文献   

14.
The electrochemical behaviors of native and thermally denatured fish DNA was investigated using boron-doped diamond (BDD) film electrode by cyclic voltammetry. The BDD electrode afforded us to measure weak current less than muA for the DNA solution in 100 microl. The mixture of acetic acid and sodium acetate solution (0.2 M) was used as a supporting electrolyte. Two oxidation peaks were observed at about +1.1 V and +1.3 V at pH 4.6 for thermally denatured fish DNA. This is due to the oxidation of guanine and adenine in the denatured fish DNA, respectively. In contrast, the native fish DNA showed ill-defined peaks at +1.1 V. Furthermore, the electrochemical behaviors of thermally denatured fish DNA were studied in the presence of cytosine, cytidine, cytidine-5-monophosphate, tetrakis(1-methypyridinium-4-yl)porphyrin (H(2)(TMPyP)(4+)) and Ru(II)(TMPyP)(4+). The oxidation peak intensity at +1.1 V gradually decreased with the increase of the concentrations of the above compounds. Based on the above studies, electrochemical behaviors of the thermally denatured fish DNA at BDD electrode is discussed.  相似文献   

15.
A novel paper-based analytical device (PAD) coupled with a silver nanoparticle-modified boron-doped diamond (AgNP/BDD) electrode was first developed as a cholesterol sensor. The AgNP/BDD electrode was used as working electrode after modification by AgNPs using an electrodeposition method. Wax printing was used to define the hydrophilic and hydrophobic areas on filter paper, and then counter and reference electrodes were fabricated on the hydrophilic area by screen-printing in house. For the amperometric detection, cholesterol and cholesterol oxidase (ChOx) were directly drop-cast onto the hydrophilic area, and H2O2 produced from the enzymatic reaction was monitored. The fabricated device demonstrated a good linearity (0.39 mg dL−1 to 270.69 mg dL−1), low detection limit (0.25 mg dL−1), and high sensitivity (49.61 μA mM−1 cm−2). The precision value for ten replicates was 3.76% RSD for 1 mM H2O2. In addition, this biosensor exhibited very high selectivity for cholesterol detection and excellent recoveries for bovine serum analysis (in the range of 99.6–100.8%). The results showed that this new sensing platform will be an alternative tool for cholesterol detection in routine diagnosis and offers the advantages of low sample/reagent consumption, low cost, portability, and short analysis time.  相似文献   

16.
The influence of the boron-doping levels in boron-doped diamond film electrodes on the electrochemical response of nitrofurantoin (NFT) and the development of an electroanalytical procedure for NFT determination were investigated. The investigations were carried out using the techniques of cyclic voltammetry and square wave voltammetry on diamond film electrodes with different boron-doping levels (i.e., 5000, 10,000 and 20,000 mg L−1). The level of boron-doping in the diamond film electrodes influenced the electrochemical reduction of NFT. The appropriate cyclic voltammetric response of NFT was obtained with Britton-Robinson buffer at pH 4 and for diamond films doped with 10,000 and 20,000 mg L−1 of boron. These two films were selected for the development of the electroanalytical procedure. The use of square wave voltammetry with the optimized parameters demonstrated a good linear relationship between the peak current and the NFT concentration for a wide range of concentration. The lower limit of detection for the electrodes doped with 10,000 and 20,000 mg L−1 of boron were 2.69 × 10−8 mol L−1 (6.40 μg L−1) and 8.15 × 10−9 mol L−1 (1.94 μg L−1), respectively, while the lower limits of quantification were 8.96 × 10−8 mol L−1 (21.33 μg L−1) and 2.72 × 10−8 mol L−1 (6.47 μg L−1), respectively. The applicability of the proposed procedure was tested using a commercial pharmaceutical formulation of NFT, and the results were compared with the procedure recommended by the British Pharmacopeia. The proposed procedure was sensitive, accurate and precise for analysis of NFT and did not require complex preparations or renovations of the electrode surface. This presents the advantage of eliminating mercury waste and minimizing the adsorptive problems related to the use of other electrodic solid surfaces.  相似文献   

17.
Methylparaben (MePa), ethylparaben (EtPa) and propylparaben (PrPa) have been widely used, among others, as chemical preservatives in cosmetics, drugs and foods. As these compounds are linked with allergies, dermatitis and estrogenic properties, it is necessary to control the concentration of these substances in different matrices. The aim of this paper are: to evaluate the electrochemical behavior of parabens on the boron-doped diamond (BDD) electrode and the development of a chromatographic method, with electrochemical detection (HPLC-ED), for determination of parabens in shampoo. A BDD (8000 ppm) electrode was adapted in a thin layer mode analytical cell consisting of a stainless steel and a platinum wire as reference and auxiliary electrodes, respectively. Chromatographic separations were obtained with a reversed phase C8 analytical column and a mobile phase of 0.025 mol L−1 disodium phosphate, pH 7.0, and acetonitrile (40:60, v/v), delivered at a flow rate of 1.0 mL min−1. Sample preparation was performed by solid phase extraction using C18 cartridges and acetonitrile for elution. Benzylparaben was employed as internal standard. The HPLC-ED method developed, using the BDD electrode, was validated for the determination of parabens in shampoos and presented adequate linearity (>0.999), in the range of 0.0125-0.500% (w/w), detectability 0.01% (w/w), precision (RSD of 2.3-9.8%) and accuracy (93.1-104.4%) and could be applied for routine quality control of shampoos containing MePa, EtPa and PrPa.  相似文献   

18.
A simple and highly selective electrochemical method was developed for the single or simultaneous determination of paracetamol (N-acetyl-p-aminophenol, acetaminophen) and caffeine (3,7-dihydro-1,3,7-trimethyl-1H-purine-2,6-dione) in aqueous media (acetate buffer, pH 4.5) on a boron-doped diamond (BDD) electrode using square wave voltammetry (SWV) or differential pulse voltammetry (DPV). Using DPV with the cathodically pre-treated BDD electrode, a separation of about 550 mV between the peak oxidation potentials of paracetamol and caffeine present in binary mixtures was obtained. The calibration curves for the simultaneous determination of paracetamol and caffeine showed an excellent linear response, ranging from 5.0 × 10−7 mol L−1 to 8.3 × 10−5 mol L−1 for both compounds. The detection limits for the simultaneous determination of paracetamol and caffeine were 4.9 × 10−7 mol L−1 and 3.5 × 10−8 mol L−1, respectively. The proposed method was successfully applied in the simultaneous determination of paracetamol and caffeine in several pharmaceutical formulations (tablets), with results similar to those obtained using a high-performance liquid chromatography method (at 95% confidence level).  相似文献   

19.
The development and validation of a multidimensional HPLC method using an on-line clean-up column coupled with amperometric detection employing a boron-doped diamond (BDD) electrode for the simultaneous determination of sulfamethoxazole (SMX) and trimethoprim (TMP) in bovine milk are presented. Aliquots of pre-prepared skim-milk samples were directly injected into a RAM octyl-BSA column in order to remove proteins that otherwise would interfere with milk analysis. After exclusion of the milk proteins, SMX and TMP were transferred to the analytical column (an octyl column) and the separation of the compounds from one another and from other endogenous milk components was achieved. SMX and TMP were detected amperometrically at 1.25 V vs. Ag/AgCl (3.0 mol L−1 KCl). Results with good linearity in the concentration ranges 50-800 and 25-400 μg L−1 for SMX and TMP, respectively, were obtained and no fouling of the BDD electrode was observed within the experimental period of several hours. The intra- and inter-assay coefficients of variation were less than 10% for both drugs and the obtained LOD values for SMX and TMP were 25.0 and 15.0 μg L−1, respectively.  相似文献   

20.
The electroanalysis of d-penicillamine in 0.1 phosphate buffer (pH 7) was studied at a boron-doped diamond thin film (BDD) electrode using cyclic voltammetry as a function of concentration of analyte and pH of analyte solution. Comparison experiments were performing using a glassy carbon (GC) electrode. The BDD electrode exhibited a well-resolved and irreversible oxidation voltammogram, but the GC electrode provided only an ill-defined response. The BDD electrode provided a linear dynamic range from 0.5 to 10 mM and a detection limit of 25 muM (S/B>/=3) in voltammetric measurement. It was also found that the peak potentials were decreased when the pH of the analyte solution was increased. In addition, penicillamine has been studied by hydrodynamic voltammetry and flow injection analysis with amperometric detection using the BDD electrode. The flow injection analysis results at the diamond electrode indicated a linear dynamic range from 0.5 to 50 muM and a detection limit of 10 nM (S/N approximately 4). The proposed method was applied to determine d-penicillamine in dosage form (capsules), the results obtained in the recovery study (255+/-2.50 mg per tablet) were comparable to those labeled (250 mg per tablet).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号