1.

Background and Purpose

Fluid-sensitive MR imaging in postoperative evaluation is important, however, metallic artifacts is inevitable. The purpose is to investigate the feasibility of fat-saturated slice encoding for metal artifact correction (SEMAC)-corrected T2-weighted magnetic resonance (MR) at 3T in patients with spinal prostheses.

Methods

Following institutional review board approval, 27 SEMAC-encoded spinal MRs between September 2012 and October 2013 in patients with spinal metallic prostheses were analyzed. The MR images were scanned on a 3T MR system including SEMAC-corrected and uncorrected fast spin echo (FSE) T2-weighted MR images with fat-saturation. Two musculoskeletal radiologists compared the image sets and qualitatively analyzed the images using a five-point scale in terms of artifact reduction around the prosthesis, visualization of the prosthesis and pedicle, and intervertebral neural foramina. Quantitative assessments were performed by calculating the ratio of signal intensity from the fixated vertebra and that from upper level vertebra. For statistical analyses, paired t-test was used.

Results

Fat-saturated SEMAC-corrected T2-weighted MR images enabled significantly improved metallic artifact reduction (P < 0.05). Quantitative evaluation of the signal intensity ratio of screw-fixated vertebra and upper level vertebra showed a significantly lower ratio on fat-saturated SEMAC images (P < 0.05), however, the high signal intensity of signal pile-up could be not completely corrected.

Conclusion

SEMAC correction in fat-suppressed T2-weighted MR images can overcome the signal loss of metallic artifacts and provide improved delineation of the pedicle screw and peri-prosthetic region. Signal pile-up, however, could not be corrected completely, therefore readers should be cautious in the evaluation of marrow around the prosthesis.  相似文献   

2.
When studying water diffusion in biological systems, any specific signal attenuation curve may be reproduced by a broad range of mathematical functions. Our goals were to quantify the diffusion and T2 relaxation properties of water in a simple biological system and to study the changes that occur in osmotically stressed cells.  相似文献   

3.
Rationale and objectivesIn magnetic resonance (MR) fetal imaging, the image quality acquired by the traditional Cartesian-sampled breath-hold T1-weighted (T1W) sequence may be degraded by motion artifacts arising from both mother and fetus. The radial VIBE sequence is reported to be a viable alternative to conventional Cartesian acquisition for both pediatric and adult MR, yielding better image quality. This study evaluated the role of radial VIBE in fetal MR imaging and compared its image quality and motion artifacts with those of the Cartesian T1W sequence.Materials and methodsWe included 246 pregnant women with 50 lesions on 1.5-T MR imaging. Image quality and lesion conspicuity were evaluated by two radiologists, blinded to the acquisition schemes used, using a five-point scale, where a higher score indicated a better trajectory method. Mixed-model analysis of variance and interobserver variability assessment were performed.ResultsThe radial VIBE sequence showed a significantly better performance than conventional T1W imaging in the head and neck, fetal body, and placenta region: 3.92 ± 0.88 vs 3 ± 0.74, p < 0.001, 3.8 ± 0.94 vs 3.15 ± 0.87, p < 0.001, and 4.17 ± 0.63 vs 3.12 ± 0.72, p < 0.001, respectively. Additionally, fewer motion artifacts were observed in all regions with the radial VIBE sequence (p < 0.01). Of 50 lesions, 49 presented better lesion conspicuity on radial VIBE images than on T1W images (4.34 ± 0.91 vs 3.48 ± 1.46, p < 0.001).ConclusionFor fetal imaging, the radial VIBE sequences yielded better image quality and lesion conspicuity, with fewer motion artifacts, than conventional breath-hold Cartesian-sampled T1W sequences.  相似文献   

4.

Purpose

The purpose of the study was to assess the usefulness of slice encoding for metal artifact correction (SEMAC) in 3.0-T magnetic resonance (MR) in minimizing metallic artifacts in patients with spinal prostheses.

Materials and Methods

Institutional review board approval and informed consent were obtained for this study. Twenty-seven spine MR scans were performed with metal artifact reduction SEMAC between May 2011 and July 2012 in patients with metallic devices. The MR scans were performed on a 3-T MR system (Achieva; Philips Healthcare, Best, the Netherlands) including SEMAC-corrected T2-weighted axial/sagittal images and two-dimensional fast spin echo (FSE) axial/sagittal images. The SEMAC-corrected images were compared to conventional T2-weighted FSE images. Two musculoskeletal radiologists qualitatively analyzed the images in terms of visualization of the pedicle, vertebral body, dural sac, intervertebral disc, intervertebral neural foramina, screws and metallic artifacts. The paired images were rated using a 5-point scale. P values less than .05 were considered to indicate statistically significant differences.

Results

The SEMAC-corrected MR images significantly reduced the metal-related artifacts. The T2-weighted images with SEMAC sequences enabled significantly improved periprosthetic visualizations of the pedicle, vertebral body, dural sac and neural foramina, with the exception of the intervertebral disc (P < .05). In addition, there was significant improvement in prosthesis visualization (P < .05).

Conclusion

MR images with SEMAC can reduce metal-related artifacts, providing improved delineation of the prosthesis and periprosthetic region. However, for the evaluation of the intervertebral disc, the SEMAC-corrected MR images showed no significant benefits.  相似文献   

5.
The purpose of this study was to evaluate the magnetic resonance (MR) cerebral venography findings of a three-dimensional phase contrast MR sequence with zero filling interpolation of the data in the slice encoding direction. Fifty volunteers were enrolled in the study. Images were obtained on a 1.5 MR imaging system with acquisition time of 12 min. MIP images were reconstructed throughout the entire imaging volume. A grading scale system was used to assess dural venous sinuses, major deep veins, cortical, and cortical eponymic veins. Inferior group of dural venous sinuses, inferior sagittal sinus, and cortical eponymic veins were poorly demonstrated. Score of the superior sagittal sinus, the straight sinus, the confluence of the superior sinus group, the right transverse and sigmoid sinuses, the internal veins, and the vein of Galen was excellent. The score of the left transverse and sigmoid sinuses was good. In conclusion, when using zero filling interpolation of the data in a three-dimensional phase contrast MR cerebral venography sequence, the superior group of dural venous sinuses and main major deep veins are demonstrated with good conspicuity.  相似文献   

6.
The purpose of this study was to evaluate the ability of three dimensional T1-weighted multi-shot Echo Planar Imaging (3D T1w EPI) MR pulse sequence to provide comparable to T1w Spin Echo (SE) results in various diseases of the brain, during shorter acquisition times. Thirty-six patients (aged 30-74 years) with various indications were included in the study. All examinations were performed with a 1T MR scanner with a maximum gradient strength of 15 mT/m. The SE sequence lasted 3 min 50s and the 3D T1w EPI 59s. The quantitative analysis included number of enhancing lesions, signal-to-noise ratio of the enhancing lesions and contrast-to-noise ratio (CNR) between enhancing lesions and white matter in both sequences before and after i.v. administration of 0.1 mmol/kg gadopentetate dimeglumine. In addition, the percentage increase of enhancement was measured in each lesion of each sequence. The qualitative analysis included a) conspicuity of the lesions and b) presence of artifacts. The T1w SE sequence was significantly better compared to 3D T1w EPI in all quantitative measurements with the exception of CNR of enhancing lesions before contrast administration and the percentage enhancement. The conspicuity of the lesions did not differ between the two sequences. The EPI sequence presented with significantly more artifacts. We conclude that the 3D T1w EPI sequence could not be used instead of the conventional T1w SE, in routine imaging of the brain. Its overall diagnostic capability, could be useful only in uncooperative patients.  相似文献   

7.
The aim of our study was to determine whether T2-weighted (T2w) MRI of the brain could be performed immediately after the administration of gadopentetate dimeglumine (gadolinium DTPA) in patients with multiple sclerosis (MS) without a loss in image quality or diagnostic reliability. Sixteen patients with clinically diagnosed MS were included in the study. Twenty-four patients with various cerebral pathologies (14 patients with multiple lacunar lesions) were examined in order to exclude masking of T2 hyperintense lesions other than MS lesions. Images of 10 patients without pathological changes served as a control condition for the qualitative analysis. In these 50 patients, T1w and T2w MRI was performed before and after the administration of gadolinium DTPA. Signal intensities were measured within T2 hyperintense cerebral lesions, in T1-enhancing lesions and in normal appearing brain tissue on T2w turbo spin-echo (TSE) sequences. Both quantitative and qualitative analysis did not show significant differences between T2w pre- and postcontrast series. T2w MRI performed prior to and after the administration of gadolinium DTPA provides similar information in patients with MS. With a TR of 3.2 s, not a single lesion was obscured on T2w postcontrast series. Acquisition of T2w MR images immediately after the administration of gadolinium DTPA allows for shorter examination time and assures sufficient time for contrast enhancement in cerebral lesions with a disrupted blood-brain barrier.  相似文献   

8.
Dynamic contrast-enhanced (DCE) T(1)-weighted magnetic resonance imaging (MRI) is a powerful tool capable of providing quantitative assessment of contrast uptake and characterization of microvascular structure in human gliomas. The kinetics of the bolus injection doped with increasing concentrations of gadopentate dimeglumine (Gd-DTPA) depends on tissue as well as pulse sequence parameters. A simple method is described that overcomes the limitation of relative signal increase measurement and may lead to improved accuracy in quantification of perfusion indices of glioma. Based on an analysis of the contrast behavior of spoiled gradient-recalled echo sequence; a parameter K with arbitrary unit 5.0 is introduced, which provides a better approximation to the differential T(1) relaxation rate. DCE-MRI measurements of relative cerebral blood volume (rCBV) and cerebral blood flow (rCBF) were calculated in 25 patients with brain tumors (15=high-grade glioma, 10=low-grade glioma). The mean rCBV was 6.46 +/- 2.45 in high-grade glioma and 2.89 +/- 1.47 in the low-grade glioma. The rCBF was 3.94 +/- 1.47 in high-grade glioma while 2.25 +/- 0.87 in low-grade glioma. A significant difference in rCBF and rCBV was found between high- and low-grade gliomas. This simple and robust technique reveals the complexity of tumor vasculature and heterogeneity that may aid in therapeutic management especially in nonenhancing high-grade gliomas. We conclude that the precontrast medium steady-state residue parameter K may be useful in improved quantification of perfusion indices in human glioma using T(1)-weighted DCE-MRI.  相似文献   

9.
Recently, a method based on intermolecular multiple quantum coherences (iMQCs) has been proposed to obtain high-resolution 2D COSY spectra in inhomogeneous fields via 3D acquisitions. However, the very long acquisition time prevents its practical application. To overcome this shortage, the Hadamard technique was applied for the iMQC method in this paper. For the new pulse sequence, the direct frequency-domain excitation is used in the first indirect detection dimension, so the 3D acquisition was replaced by an array of 2D acquisitions. The acquisition time can be reduced to 10 min. The resulting spectra retain useful structural information including chemical shifts and multiplet patterns of J coupling even when the inhomogeneous line broadening leads to overlap of neighboring diagonal resonances in the conventional COSY spectrum. The experimental results are consistent with the theoretical predictions and computer simulations. The new sequence may provide a time-efficient way for the studies of chemical solution in inhomogeneous fields.  相似文献   

10.
A fast spin echo two-point Dixon (fast 2PD) technique was developed for efficient T2-weighted imaging with uniform water and fat separation. The technique acquires two interleaved fast spin echo images with water and fat in-phase and 180° out-of-phase, respectively, and generates automatically separate water and fat images for each slice. The image reconstruction algorithm uses an improved and robust region-growing scheme for phase correction and achieves consistency in water and fat identification between different slices by exploiting the intrinsic correlation between the complex images from two neighboring slices. To further lower the acquisition time to that of a regular fast spin echo acquisition with a single signal average, we combined the fast 2PD technique with sensitivity encoding (SENSE). Phantom experiments show that the fast 2PD and SENSE are complementary in scan efficiency and signal-to-noise ratio (SNR). In vivo data from scanning of clinical patients demonstrate that T2-weighted imaging with uniform and consistent fat separation, including breath-hold abdominal examinations, can be readily performed with the fast 2PD technique or its combination with SENSE.  相似文献   

11.
In (3)He magnetic resonance images of pulmonary air spaces, the confining architecture of the parenchymal tissue results in a non-Gaussian distribution of signal phase that non-exponentially attenuates image intensity as diffusion weighting is increased. Here, two approaches previously used for the analysis of non-Gaussian effects in the lung are compared and related using diffusion-weighted (3)He MR images of mechanically ventilated rats. One approach is model-based and was presented by Yablonskiy et al., while the other approach utilizes the second order decay contribution that is predicted from the cumulant expansion theorem. Total lung coverage is achieved using a hybrid 3D pulse sequence that combines conventional phase encoding with sparse radial sampling for efficient gas usage. This enables the acquisition of nine 3D images using a total of only approximately 1 L of hyperpolarized (3)He gas. Diffusion weighting ranges from 0 s/cm(2) to 40 s/cm(2). Results show that the non-Gaussian effects of (3)He gas diffusion in healthy rat lungs are directly attributed to the anisotropic geometry of lung microstructure as predicted by the Yablonskiy model, and that quantitative analysis over the entire lung can be reliably repeated in time-course studies of the same animal.  相似文献   

12.
An approach has been recently introduced for acquiring two-dimensional (2D) nuclear magnetic resonance images in a single scan, based on the spatial encoding of the spin interactions. This article explores the potential of integrating this spatial encoding together with conventional temporal encoding principles, to produce 2D single-shot images with moderate field of views. The resulting “hybrid” imaging scheme is shown to be superior to traditional schemes in non-homogeneous magnetic field environments. An enhancement of previously discussed pulse sequences is also proposed, whereby distortions affecting the image along the spatially encoded axis are eliminated. This new variant is also characterized by a refocusing of T2* effects, leading to a restoration of high-definition images for regions which would otherwise be highly dephased and thus not visible. These single-scan 2D images are characterized by improved signal-to-noise ratios and a genuine T2 contrast, albeit not free from inhomogeneity distortions. Simple postprocessing algorithms relying on inhomogeneity phase maps of the imaged object can successfully remove most of these residual distortions. Initial results suggest that this acquisition scheme has the potential to overcome strong field inhomogeneities acting over extended acquisition durations, exceeding 100 ms for a single-shot image.  相似文献   

13.
14.
Diffusion- and T2-weighted MRI were used to evaluate changes in brain water characteristics following closed-head injury in rats. Images were collected within the first 2 h and at 24 h and 7 days following the traumatic event and then compared with histology. The ratios between the apparent diffusion coefficients (ADCs) of the traumatized tissues and normal brain tissues were significantly different from unity and were found to be 0.79 ± 0.25 (p < 0.01), 0.49 ± 0.33 (p < 0.0002), and 3.47 ± 1.36 (p < 10−6) at 1–2 h, 24 h, and 1 week after the trauma, respectively. In severe trauma, areas of hyperintensity which were not apparent on the T2-weighted images could be detected on the diffusion-weighted images within 1–2 h after the trauma. At 24 h following the traumatic event, large areas of hyperintensity are observed in both types of images. One week following the trauma, the ADCs of the traumatized tissues (1.84 ± 0.69 × 10−5 cm2/s) are much larger than those of normal brain (0.57 ± 0.19 × 10−5 cm2/s) and approach the value of free water. At 7 days, the areas of hyperintensity in the T2-weighted images seem to underestimate the injured areas found by histology. At this time point a good correlation is obtained between the areas of hypointensity observed on the diffusion-weighted images and the infarct areas obtained by histology (r = 0.88).  相似文献   

15.
This paper presents a method to correct intensity nonuniformity in spin-echo T(1)-weighted images and particularly the inhomogeneities due to RF transmission imperfections which have tissue-dependent effects through the T(1) relaxation times. This method is based on the use of a uniform phantom, first for classic normalization by division by the phantom images, and second for T(1)-correction using the RF transmitted cartography. We present experimental results from a bi-phasic (oil/water) phantom and from a salmon with a 0.2 T imager. The results demonstrate the efficiency of the method in the two cases and its ability to cope with partial volume effect.  相似文献   

16.
The purpose of this study was to develop a multi-shot dual-echo breathhold fast spin echo technique (DFSE) and compare it with conventional spin echo (T2SE) for T(2)-weighted MR imaging of liver lesions. The DFSE acquisition (EffTE1/EffTE2/TR = 66/143/2100 ms) imaged 5 sections per 17 s breathhold. T2SE imaging (TE1/TE2/TR = 60/120/2500 ms) required 16:55 (min:s) for 14 sections. Both techniques used a receive-only phased-array abdominal multicoil and provided 192 x 256 effective resolution. The results showed first and second echo relative DFSE/T2SE contrast values for 27 representative lesions (15 consecutive patients) were 1.08 +/- 0.05 and 1.16 +/- 0.09 (mean +/- STD mean), respectively. Corresponding CNR values were 1.12 +/- 0.09 and 0.97 +/- 0.12. Overall DFSE was comparable-to-superior to T2SE for lesion sizing and image artifact. DFSE lesion detection was inferior to T2SE's in several patient studies because of decreased conspicuity of lesions located near multicoil edges and because of poor breathhold-to-breathhold reproducibility and lack of breathholding. However both DFSE (and T2SE) provided lesion detection rated to be of diagnostic quality for all patient studies. In conclusion, we found that DFSE provides diagnostically useful dual-echo T(2)-weighted MR liver images in a greatly decreased acquisition time.  相似文献   

17.
Significant artifacts arise in T(1rho)-weighted imaging when nutation angles suffer small deviations from their expected values. These artifacts vary with spin-locking time and amplitude, severely limiting attempts to perform quantitative imaging or measurement of T(1rho) relaxation times. A theoretical model explaining the origin of these artifacts is presented in the context of a T(1rho)-prepared fast spin-echo imaging sequence. Experimentally obtained artifacts are compared to those predicted by theory and related to B(1) inhomogeneity. Finally, a "self-compensating" spin-locking preparatory pulse cluster is presented, in which the second half of the spin-locking pulse is phase-shifted by 180 degrees. Use of this pulse sequence maintains relatively uniform signal intensity despite large variations in flip angle, greatly reducing artifacts in T(1rho)-weighted imaging.  相似文献   

18.
The purpose of this study was to quantitatively evaluate in a phantom model the practical impact of alteration of key imaging parameters on image quality and artifacts for the most commonly used fast T(2)-weighted MR sequences. These include fast spin-echo (FSE), single shot fast spin-echo (SSFSE), and spin-echo echo-planar imaging (EPI) pulse sequences. We developed a composite phantom with different T1 and T2 values, which was evaluated while stationary as well as during periodic motion. Experiments involved controlled variations in key parameters including effective TE, TR, echo spacing (ESP), receive bandwidth (BW), echo train length (ETL), and shot number (SN). Quantitative analysis consisted of signal-to-noise ratio (SNR), image nonuniformity, full-width-at-half-maximum (i.e., blurring or geometric distortion) and ghosting ratio. Among the fast T(2)-weighted sequences, EPI was most sensitive to alterations in imaging parameters. Among imaging parameters that we tested, effective TE, ETL, and shot number most prominently affected image quality and artifacts. Short T(2) objects were more sensitive to alterations in imaging parameters in terms of image quality and artifacts. Optimal clinical application of these fast T(2)-weighted imaging pulse sequences requires careful attention to selection of imaging parameters.  相似文献   

19.
在多通道量子亏损理论框架下,利用相对论多通道理论,分别在冻结实近似和考虑偶极极化下计算钪原子的Jπ=(3/2)-,(5/2)-的三个收敛于[Ar]3d4s(1D2)的自电离里德伯系列的能级.对3d4s(1D2)np2D3/2和3d4s(1D2)nf2F5/2这两个系列,计算结果表明,考虑偶极极化效应后,理论计算和实验测量的量子数亏损之差普遍小于0.01.而对3d4s(1D2)nf2D3/2系列,考虑偶极极化效应后的结果和仅考虑冻结实的结果比较接近,理论计算和实验测量的量子数亏损之差普遍在0.04左右.  相似文献   

20.
The (29)Si spin-lattice relaxation in porous silica-based material 1, doped by ions Mn(2+) at a Si/Mn ratio of 3.5, is non-exponential, independent of magic-angle spinning (MAS) rates and governed by direct dipolar coupling between electron and nucleus where an electron relaxation time is estimated to be about 10(-8)s. In the absence of mutual energy-conserving spin flips (spin diffusion) in 1, the (29)Si T(2) time increases linearly with spinning rates. None was observed in diamagnetic porous system 2. The unexpected (29)Si T(2) dependence has been interpreted in terms of the large bulk magnetic susceptibility (BMS) effects. It has been shown that editing the (29)Si Hahn-echo MAS NMR spectra eliminates wide lines, belonging to (29)Si nuclei in the proximity of paramagnetic centers, and reduces the BMS broadenings in sideband patterns for nuclei remote from these centers.  相似文献   