首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An analytical approach is described for the molecular weight characterization of glucose oligomers from cellulose which had been decomposed by hot-compressed water (HCW). Microcrystalline cellulose was decomposed to 18% of water insoluble fraction (WI) plus 82% of water soluble fraction (WS) by HCW (295 degrees C, 10 mL/min). The glucose oligomers in the WI were analyzed by pericullar anion exchange chromatography, and oligomers longer than pentamers were detected. These results were also confirmed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). Many peaks derived from glucose oligomers with molecular weights less than 4000 Da were detected in the spectra. Mass differences between peaks were 162 Da, as expected for polymers composed of glucose units. This appears to be the first report concerning molecular weight determination of water or organic solvent insoluble compounds like glucose oligomers from cellulose using MALDI-TOFMS.  相似文献   

2.
The detection of water-soluble vitamins B(1), B(2), B(6), B(12) and C by matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry (TOFMS) was attempted by studying 17 porphyrin matrices. Comparative studies of porphyrin matrices, useful mass spectral window, matrix/analyte molar ratio (M/A), ultraviolet-visible absorption characteristics and quantitative results were made. Most porphyrin matrices provide a useful mass spectral window in the low-mass range. The optimal M/A increases with increasing molecular mass of the vitamin. Vitamin B(12) possesses the highest molecular mass and requires a higher M/A. The presence of hydroxyl or carboxyl groups in the porphyrin is an indicator of a useful MALDI matrix. Vitamins B(2) and B(6) were readily ionized upon irradiation with a 337 nm laser without the use of any porphyrin matrix. Improved linearity and sensitivity of the calibration curves were obtained with samples prepared with a constant M/A. The limits of detection and quantitation are at the picomole level. The results indicate that MALDI-TOFMS with porphyrin matrices is a rapid and viable technique for the detection of low molecular mass water-soluble vitamins.  相似文献   

3.
A novel method for acquisition and numerical analysis of matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectral data is described. The digitized ion current transient from each consecutive laser shot is first acquired and stored independently. Subsequently, statistical correlation parameters between all stored transients are computed. We illustrate the uses of this event-by-event analysis method for studies of sample surface heterogeneity as well as for elucidating the mechanisms of ion formation in MALDI. Other potential applications of the method are also outlined.  相似文献   

4.
This study reports a novel approach utilizing an octahedral CoII(HAPP)(TFA)2 reagent in the presence of H2O2 with analysis by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) to serve as an efficient probe for bulged DNA structures. Elucidation of DNA bulge-specific recognition pathways and cleavage mechanisms is demonstrated by characterization of bulge-specific cleavage products and other backbone lesion fragments. The cleavage specificity of CoII(HAPP)(TFA)2/H2O2 arises from sugar oxidative strand scission, for which the position of the abstracted hydrogen is unambiguously determined as the 4'-H of the deoxyribose moiety. Furthermore, differentiation between bulge-specific recognition and diffusion-controlled non-selective cleavage can be clarified through time-dependent MALDI-TOFMS studies. The present results demonstrate that MALDI-TOFMS can be a sensitive and efficient technique for complex mechanistic studies of this kind, providing information for future rational drug design targeting bulged DNA structures.  相似文献   

5.
We report the detection of nanoparticles formed by irradiating matrix-assisted laser desorption/ionization (MALDI) matrix samples. This is direct evidence for the ejection of large size aggregates in the MALDI process. Nanometer-size particles were generated via a tunable solid-state UV laser, irradiating a sample placed in a nitrogen atmosphere. Size distribution measurements were performed using a differential mobility analyzer and a condensation particle counter. Particles in the 10-1000 nm size range were detected. The dependence of the particle size distribution on the laser fluence, wavelength and matrix was investigated. The observed effects are discussed and related to the MALDI ablation dynamics and gas-phase processes.  相似文献   

6.
A prototype matrix-assisted laser desorption/ionization quadrupole time-of-flight (MALDI-TOF) tandem mass spectrometer was used to sequence a series of phosphotyrosine-, phosphothreonine- and phosphoserine-containing peptides. The high mass resolution and mass accuracy of the instrument allowed the localization of one, three or four phosphorylated amino acid residues in phosphopeptides up to 3.1 kDa. Tandem mass spectra of two different phosphotyrosine peptides permitted amino acid sequence determination and localization of one and three phosphorylation sites, respectively. The phosphotyrosine immonium ion at m/z 216.04 was observed in these MALDI low-energy CID tandem mass spectra. Elimination of phosphate groups was evident from the triphosphorylated peptide but not from the monophosphorylated species. The main fragmentation pathway for the synthetic phosphothreonine-containing peptide and for phosphoserine-containing peptides derived from beta-casein and ovalbumin was the beta-elimination of phosphoric acid with concomitant conversion of phosphoserine to dehydroalanine and phosphothreonine to 2-aminodehydrobutyric acid. Peptide fragment ions of the b- and y-type allowed, in all cases, the localization of phosphorylation sites. Ion signals corresponding to (b-17), (b-18) and (y-17) fragment ions were also observed. The abundant neutral loss of phosphoric acid (-98 Da) is useful for femtomole level detection of phosphoserine-peptides in crude peptide mixtures generated by gel in situ digestion of phosphoproteins.  相似文献   

7.
The identification of isoforms is one of the great challenges in proteomics due to the large number of identical amino acids preventing their separations by two-dimensional electrophoresis. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) has become a rapid and sensitive tool in proteomics, notably with the new instrumental improvements. In this study, we used several acquisition modes of MALDI-TOFMS to identify isoforms of porcine glutathiones S-transferase. The use of multiple proteases coupled to the different acquisition modes of MALDI-TOFMS (linear, reflectron, post-source decay (PSD) and in-source decay, positive and negative modes) allowed the identification of two sequences. Moreover, a third sequence is pointed out from a PSD study of a tryptic ion revealing the modification of the amino acid tyrosine 146 to phenylalanine.  相似文献   

8.
A variety of surfactants have been tested as matrix-ion suppressors for the analysis of small molecules by matrix-assisted laser desorption/ionization time-of flight mass spectrometry. Their addition to the common matrix alpha-cyano-4-hydroxycinnamic acid (CHCA) greatly reduces the presence of matrix-related ions when added at the appropriate mole ratio of CHCA/surfactant, while still allowing the analyte signal to be observed. A range of cationic quaternary ammonium surfactants, as well as a neutral and anionic surfactant, was tested for the analysis of phenolics, phenolic acids, peptides and caffeine. It was found that the cationic surfactants, particularly cetyltrimethylammonium bromide (CTAB), were suitable for the analysis of acidic analytes. The anionic surfactant, sodium dodecyl sulfate, showed promise for peptide analysis. For trialanine, the detection limit was observed to be in the 100 femtomole range. The final matrix/surfactant mole ratio was a critical parameter for matrix ion suppression and resulting intensity of analyte signal. It was also found that the mass resolution of analytes was improved by 25-75%. Depth profiling of sample spots, by varying the number of laser shots, revealed that the surfactants tend to migrate toward the top of the droplet during crystallization, and that it is likely that the analyte is also enriched in this surface region. Here, higher analyte/surfactant concentration would reduce matrix-matrix interactions (known to be a source of matrix-derived ions).  相似文献   

9.
3-Hydroxycoumarin (3-HC) was designed, synthesized, and tested as a matrix for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) analyses of a variety of synthetic oligodeoxynucleotides ranging long from three to 70 bases. Using the matrix solution of 3-HC dissolved in a mixed solvent of acetone and diammonium hydrogen citrate, DNA segments over the mass range 800 Da to 6900 Da were isotopically resolved with high signal-to-noise (S/N) ratio. The individual isotopic molecular ion peaks of a group of 23-mer mixed-base oligomers differing by one or two bases with mass differences of 9 or 7 Da were recorded. Larger oligodeoxynucleotide segments of 34-mer, 50-mer, and 70-mer have also been analyzed effectively. Less than 250 attomol of a 10-mer DNA segment was clearly detected without any fragmentation. The new matrix can be used for the analysis of DNA segments in both positive- and negative-ion modes, and the quality of all negative-ion mode spectra are as good as that obtained in positive-ion mode shown in this paper. Compared with conventional matrices of 3-hydroxypicolinic acid (3-HPA) and 6-aza-2-thiothymine (ATT), 3-HC had noticeable improvement in resolution, S/N ratio, spot-to-spot-, and sample-to-sample reproducibility for analyzed DNA segments.  相似文献   

10.
11.
A new two-component system, consisting of a matrix and an onium salt as comatrix, is described for detection of sulfo-peptides in the positive mode by matrix-assisted desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). Binary iodonium salts were superior to quaternary phosphonium salts in terms of suppression of desulfation and salt formation with the carboxyl group. Of the iodonium salts examined, bis(4-tert-butylphenyl)iodonium (BTI) hexafluorophosphate and bromide were most effective in giving intensive molecular ion signals in the form of [M(BTI)+BTI](+). The conditions optimized for O-sulfated tyrosine-containing peptides could be applicable for O-sulfated serine- and threonine-containing peptides. In the case of a phospho-peptide, a molecular ion appeared more intensively as a proton adduct than as a BTI adduct.  相似文献   

12.
13.
The detection of phospholipids (PLs) by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry was demonstrated nearly a decade ago. However, its use as a conventional tool for PL analysis has been hindered by ambiguities in peak assignments caused by spectral overlaps and difficulties in the detection of some PL classes when analytes with positively charged head groups, such as sphingomyelins (SMs) and phosphatidylcholines (PCs) are present. In this work, either a strong cation-exchange resin or CsCl crystals were added directly to the PL samples to reduce spectral complexity and enhance sensitivity. The quantitative exchange resulted in virtually only protonated or Cs+ adducts. To alleviate difficulties in the detection and identification of PL classes with ionization efficiencies lower than those of SMs and PCs, improvements in the sensitivity of negative-ion mass spectra were sought. For this purpose, several neutral and basic matrices were tried. Among them, p-nitroaniline (PNA) proved to be an advantageous alternative to the use of 2,5-dihydroxybenzoic acid (DHB), the most commonly used matrix in PL analysis. Because of its lower acidity, PNA increased the relative amount of deprotonated species and improved the sensitivity of negative-ion mass spectra. It was possible to confirm peak assignments for PL classes that normally give weak signals when DHB is used. Noteworthy is the detection (in both positive and negative modes) and conclusive identification of species in natural mixtures of phosphatidylethanolamines (PEs) and PE plasmalogens (PEps). PNA allowed the identification of PEs and PEps even in mixtures containing SMs and PCs. Although some cations related to PCs and PEs overlapped in positive-ion spectra, these interferences were eliminated in the negative mode as only the deprotonated forms of PEs and PEps were detectable and those of SMs and PCs were absent owing to their neutrality.  相似文献   

14.
The use of matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) mass spectrometry (MS) for the quantitative determination of phospholipid (PL) molecular species has been problematic, due primarily to the formation of multiple signals (corresponding to the molecular ion and other adducts) for some classes of PL. For example, analysis of phosphatidylcholine (PC) yielded signals that corresponded to protonated and sodiated molecules in the MALDI spectrum. The resulting spectral overlap among various molecular species (e.g. [PC(16:0/18:2) + Na] and [PC(18:2/18:3)]) made it impossible to ascertain their relative amounts using this technique. Other spectral ambiguities existed among different structural isomers, such as PC(18:1/18:1) and PC(18:0/18:2). We determined that molecular species could be resolved by MALDI-TOFMS by first removing the polar head (e.g. phosphocholine) from the phospholipid to effect production of only the sodiated molecules of the corresponding diacylglycerols (DAGs). Analysis of the resulting spectrum allowed unequivocal determination of the molecular species profile of PC from potato tuber and soybean. Estimation of fatty acid composition based on the molecular species determined by MALDI-TOFMS analysis agreed with that from GC-FID analysis. Post-source decay (PSD) was used to resolve standard isomers of PC (e.g. 18:1/18:1 vs. 18:0/18:2). Our results indicated that PSD is a useful approach for resolving structural isomers of PL molecular species.  相似文献   

15.
This study presents matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) as a powerful tool to analyze and characterize oligonucleotides covalently linked to a solid support during their synthesis. The analysis of the fragment ions generated either in negative or positive mode allows direct and easy access to the nucleotide sequence and identification of the internucleosidic linkage. The mechanisms of the fragmentation of the solid-supported oligonucleotides induced by MALDI-TOFMS are discussed. Copyright 2000 John Wiley & Sons, Ltd.  相似文献   

16.
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) and laser desorption/ionization (LDI-)TOFMS have been used to characterize Suwannee River humic substances, obtained from the International Humic Substances Society (IHSS), and Armadale soil fulvic acid (ASFA). An array of MALDI matrices were tested for use with humic substances, including alpha-cyano-4-hydroxycinammic acid (CHCA), 2-(4-hydroxyphenylazo)benzoic acid (HABA), 2,5-dihydroxybenzoic acid (DHBA), sinapinic acid, dithranol and norharmane. DHBA yielded the best results, exhibiting superior ionization efficiency, low noise, broad applicability to the analytes of interest, and most importantly producing an abundance of high mass ions, the highest observed being m/z 1848. A number of sample preparation modes were investigated; the overlayer method improved sample/matrix homogeneity and hence shot-to-shot reproducibility. The choice of the matrix, mass ratio of analyte to matrix, and the sample preparation protocol, were found to be the most critical factors governing the quality of the mass spectra. Matrix suppression was greatly enhanced by ensuring good mixing of matrix and analyte in the solid phase, proper optimization of the matrix/analyte ratio, and optimizing delayed extraction to ensure complete matrix-analyte reaction in the plume before ions are moved to the flight tube. A number of common features, in particular specific ions which could not be attributed to the matrices or to contaminants, were present in the spectra of all the humic substances, regardless of origin or operational definition. Additionally, a prominent repeating pattern of peaks separated by 55, 114 and 169 Da was clearly observed in both LDI and MALDI, suggesting that the humic compounds studied here may have quasi-polymeric or oligomeric features.  相似文献   

17.
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is used as an alternative method for the rapid diagnosis of albuminuria. This technique requires no further sample pretreatment than simply mixing the urine sample with a MALDI matrix and drying under ambient conditions. The resulting MALDI mass spectra reveal albumin ions having charges ranging from +1 to +5. The detection of albumin is possible using any of the three most common MALDI matrices - sinapinic acid (SA), 2,5-dihydroxybenzoic acid (2,5-DHB), or 4-hydroxy-alpha-cyanocinnamic acid (alpha-CHC). Using this analytical approach, the limit of detection for albumin in urine is 10(-6) M, approximately 5 to 10 times lower than that detectable through conventional chemical testing.  相似文献   

18.
In an effort to gain an understanding of the processes governing ultraviolet matrix-assisted laser desorption/ionization (UV-MALDI), direct comparison was made of the mass spectra of proteins, carbohydrates and synthetic polymers (polyethylene glycol, polyester and polyamide) by using pyridylindoles, pyridoindoles and pyridylpyridoindoles as UV (337 nm)-MALDI-TOFMS matrices in positive and negative ion mode. In order to study the combined effect of the indole N-H and the pyridine nitrogen of the MALDI matrix on the desorption/ionization process in MALDI, compounds were selected that include either or both of these functions in their structure. Within the compounds studied only those that possess simultaneously both functions in a 1,4-relation behave as very good matrices for proteins. These compounds also work as matrices for some carbohydrates and synthetic polymers used as analytes in the present study. Some of the compounds were also found to be useful for the post-source decay (PSD) analysis of cyclodextrins in positive and negative ion mode. In several cases we also examined the matrix behavior of the corresponding N-methylindole derivatives.  相似文献   

19.
The intact fungal spores of several strains of four Aspergillus species, Aspergillus flavus, A. oryzae, A. parasiticus, and A. sojae, were directly analyzed by matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry. Very simple MALDI mass spectra are obtained by directly mixing spores with a matrix such as alpha-cyano-4-hydroxycinnamic acid or sinapinic acid. The mass spectra are obtained from the ablation of cell walls of spores owing to the acidity of the matrix solution. The MALDI results show that aflatoxigenic strains and non-aflatoxigenic strains have different mass peak profiles. Furthermore, the MALDI results of non-aflatoxigenic A. flavus and A. parasiticus spores resemble those of the closely related A. oryzae and A. sojae spores, respectively.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏