首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
The feasibility of using ethyl acetate for the desorption of trace pollutants from a liquid chromatographic precolumn on-line into a diphenyltetramethyldisilazane-deactivated retention gap and, subsequently analysis by means of capillary gas chromatography has been demonstrated. First 5% of methanol are added to the water sample to prevent sorption of analytes onto parts of the preconcentration system. About 1 ml of this aqueous sample is injected onto a precolumn containing a polymeric stationary phase, using water–methanol (95:5, v/v) for transport and clean-up. The precolumn is desorbed with ethyl acetate and a fraction of 75 μl is injected on-line into the retention gap; separation is then achieved on a capillary CP Sil 19 column. No breakthrough of the test compounds was observed in the preconcentration step. The recovery was quantitative and the response obtained with flame ionization detection was linear in the range 0.1–100 ng/ml. The effect of varying the sorption flow rate on the recovery was studied. The system was applied to the analysis of river water.  相似文献   

3.
基于原煤和有机溶剂抽余物的等温吸附实验结果,对比分析溶剂极性与其煤抽余物吸附甲烷能力变化关系,探讨抽提溶剂极性差异对煤抽余物吸附甲烷能力控制的地球化学机理。结果表明,煤溶剂抽余物等温吸附甲烷曲线都遵循Langmuir方程,且二硫化碳(CS2)和苯(C6H6)溶剂抽提作用增大了煤吸附甲烷量,四氢呋喃(THF)和丙酮溶剂抽提作用减小了煤吸附甲烷量。实验发现,煤抽余物吸附甲烷能力变化与抽提溶剂极性成负相关关系,该现象可用相似相容原理解释:CS2和C6H6溶剂极性较弱,抽提出较多具有非极性结构(-CH3和-CH2-)的烷烃和芳烃,为甲烷在煤表面吸附增多了吸附位而增强了抽余物吸附甲烷能力,THF和丙酮溶剂极性较强,抽提出较多具有极性结构(-CHO、-OH、和-COOH)的非烃和沥青质,减少了吸附位而降低煤抽余物的甲烷吸附能力。  相似文献   

4.
Coupling column liquid chromatography and gas chromatography on-line is becoming more important in analytical chemistry. Especially when large amounts of polar solvents can be introduced into the gas chromatograph without any problem, the technique will offer new possibilities. With a DPTMDS retention gap, evaporation rates and flooded zones of some solvents have been determined. Two modes of operation using partially concurrent solvent evaporation conditions are discussed: (1) injecting a sample via a loop of an LC valve followed by introduction into the gas chromatograph with an LC pump; (2) trace enrichment on a precolumn followed by on-line desorption with n-propanol into the gas chromatograph. Preliminary results for a splitter system, inserted between the retention gap and the analytical column which allows a considerable increase of the evaporation rate are also presented.  相似文献   

5.
A high temperature gas chromatograph has been developed which is capable of operating at column oven temperatures up to 500°C. In addition, the detector can operate at temperatures up to 500°C, and the injector up to 450°C. The injector on this instrument is a temperature programmable direct injector, designed specifically to introduce labile or high molecular weight samples into the GC without molecular weight discrimination. The design of this GC and injector will be described, and high temperature applications will be discussed.  相似文献   

6.
楼佳 《化学研究》2011,22(2):65-67
采用快速溶剂萃取-气相色谱/质谱联用法(ASE-GC/MS)和超声波萃取-气相色谱/质谱联用法(USE-GC/MS)测定了塑料桌布中的邻苯二甲酸酯.结果表明:ASE-GC/MS的测量精度优于USE-GC/MS,后者测量值大约为前者的五分之四;ASE-GC/MS的回收率为89.0%~95.5%,相对标准偏差为4.3%~1...  相似文献   

7.
This paper presents a new sample preparation procedure for determination of selected acidic pharmaceuticals (ibuprofen, naproxen, ketoprofen, and diclofenac) in sewage sludge using microwave assisted solvent extraction, dispersive matrix extraction (DME) followed by the conventionally applied solid phase extraction (SPE), derivatization, and gas chromatography-mass spectrometry. The recoveries calculated from analytical data of spiked sludge samples changed in the range of 80-105% ± 15% for the four pharmaceuticals in mixed and activated sludge depending on the efficiency of the clean-up procedure. The measured concentration values of ibuprofen and naproxen were identical in the mixed and the activated sludge samples. However, ketoprofen and diclofenac showed about twice as high concentration in activated sludge than in the mixed one independently of the applied extraction method. The typical concentration ranges of ibuprofen, naproxen, ketoprofen and diclofenac in sewage sludge were 10-30 ng/g, 30-50 ng/g, 50-130 ng/g, and 50-140 ng/g respectively.  相似文献   

8.
Gonçalves C  Alpendurada MF 《Talanta》2005,65(5):1179-1189
In order to reduce the amount of sample to be collected and the time consumed in the analytical process, a broad range of analytes should be preferably considered in the same analytical procedure. A suitable methodology for pesticide residue analysis in soil samples was developed based on ultrasonic extraction (USE) and gas chromatography–mass spectrometry (GC–MS). For this study, different classes of pesticides were selected, both recent and old persistent molecules: parent compounds and degradation products, namely organochlorine, organophosphorous and pyrethroid insecticides, triazine and acetanilide herbicides and other miscellaneous pesticides. Pesticide residues could be detected in the low- to sub-ppb range (0.05–7.0 μg kg−1) with good precision (7.5–20.5%, average 13.7% R.S.D.) and extraction efficiency (69–118%, average 88%) for the great majority of analytes. This methodology has been applied in a monitoring program of soil samples from an intensive horticulture area in Póvoa de Varzim, North of Portugal. The pesticides detected in four sampling programs (2001/2002) were the following: lindane, dieldrin, endosulfan, endosulfan sulfate, 4,4′-DDE, 4,4′-DDD, atrazine, desethylatrazine, alachlor, dimethoate, chlorpyrifos, pendimethalin, procymidone and chlorfenvinphos. Pesticide contamination was investigated at three depths and in different soil and crop types to assess the influence of soil characteristics and trends over time.  相似文献   

9.
A simple microwave-assisted extraction and partitioning method (MAEP) using water-acetonitrile and n-hexane for desorption and simultaneous partitioning, respectively, together with gas chromatography (GC) was studied to determine representative pesticides (trifluralin, metolachlor, chlorpyriphos and triadimefon) with a broad range of physico-chemical properties in agricultural soils. Three points were considered crucial in this study: instrumental and sample-associated factors affecting extraction of the target compounds were studied through experimental design; the spiking procedure at trace levels was carried out to reproduce the solute-soil sorption taking place in the environment as closely as possible; and results were analyzed taking into account the adsorption behaviour of the compounds on different kinds of soils. The complete analytical procedure proposed consisted of the MAEP of pesticides from 1.0 g of soil with 1 mL of 1:1 water/acetonitrile mixture, and 5 mL of hexane for trapping. The microwave heating program applied was 2 min at 250 W and 10 min at 900 W, and 130 °C maximum temperature. After extraction, the hexane layer was evaporated to dryness; the residue was re-dissolved and directly analyzed by gas chromatography electron capture detection (GC-ECD). Clean chromatograms were obtained without any additional cleanup step. Besides the four pesticides used to optimise MAEP, the method was applied to determine an additional group of pesticides (triallate, acetochlor, alachlor, endosulphan I and II, endrin, methoxychlor and tetradifon) in different soils. Most of the compounds studied were recovered in good yields with relative standard deviations (R.S.D.s) below 9% and detection limits ranged from 0.004 to 0.036 μg g−1. The described method is efficient and fast to determine hydrophobic pesticides at ng g−1 level in soil with different clay-to-organic matter ratios.  相似文献   

10.
A novel solid-phase extraction element is developed for sorptive enrichment of dilute analytes from liquid samples with high extraction efficiencies due to its larger amounts of polydimethylsiloxane (PDMS) absorbent than the conventional syringe type of solid-phase microextraction (SPME). The extraction element is made of titanium (Ti) open tubular tube (30 mm x 1.2 mm i.d. x 1.6 mm o.d.) coated with a chemically bonded layer of PDMS (500 microm in thickness). The extraction element combined with thermal desorption-gas chromatography-mass spectrometry using a pyrolysis-gas chromatography-mass spectrometry system was used to extract and analyze a typical herbicide, bethrodine in water samples over a concentration range from 2.5 to 2.5 x 10(4) ng/l. Thus obtained calibration curve showed good linearity for the tested whole concentration range with regression coefficient of 0.992. Detection limit of 0.5 ng/l level was achieved and the reproducibility of the measurements for bethrodine at 10 ng/l level was found to be fairly good with relative standard deviation below 7.5%.  相似文献   

11.
A sensitive and selective gas chromatography with mass spectrometry method was developed for the simultaneous determination of three organophosphorus pesticides, namely, chlorpyrifos, malathion, and diazinon in three different food commodities (milk, apples, and drinking water) employing solid‐phase extraction for sample pretreatment. Pesticide extraction from different sample matrices was carried out on Chromabond C18 cartridges using 3.0 mL of methanol and 3.0 mL of a mixture of dichloromethane/acetonitrile (1:1 v/v) as the eluting solvent. Analysis was carried out by gas chromatography coupled with mass spectrometry using selected‐ion monitoring mode. Good linear relationships were obtained in the range of 0.1–50 μg/L for chlorpyrifos, and 0.05–50 μg/L for both malathion and diazinon pesticides. Good repeatability and recoveries were obtained in the range of 78.54–86.73% for three pesticides under the optimized experimental conditions. The limit of detection ranged from 0.02 to 0.03 μg/L, and the limit of quantification ranged from 0.05 to 0.1 μg/L for all three pesticides. Finally, the developed method was successfully applied for the determination of three targeted pesticides in milk, apples, and drinking water samples each in triplicate. No pesticide was found in apple and milk samples, but chlorpyrifos was found in one drinking water sample below the quantification level.  相似文献   

12.
This study describes an SPE coupled with large volume injection (LVI) analytical method for the analysis of organochlorine pesticides, BHC (alpha, beta, delta), aldrin, endosulfan (alpha, beta), endrin, dieldrin, and DDT, from aqueous samples. Determination was carried out by GC with MS. The LODs of organochlorine pesticides were determined at 10 ng/L concentration levels, and the results show that SPE-LVI-GC/MS has the potential to accurately determine organochlorine pesticides in water, as it avoids analyte classes in the various steps of a typical extraction procedure.  相似文献   

13.
A new gas chromatographic (GC) retention index based on a homologous series of tri-n-alkylamines is proposed for use in the detection of pesticides and related compounds because the standard n-paraffin hydrocarbons used for the Kovats index do not show up well on the nitrogen-phosphorus detectors commonly used in pesticide analysis. Using fused silica bonded phase capillary columns (DB-1 or DB-5), the trialkylamine indices of 106 selected pesticides and related compounds were measured and their relationship to the Kovats index determined.  相似文献   

14.
ABSTRACT

A multi-residue method using selected ion monitoring mode GC-MSD has been developed for the quantitative analysis of 30 widely used pesticides in fresh peaches produced in Swat Malakand, Pakistan. The planned methodology involved a sample extraction procedure using liquid-liquid partition with acetonitrile followed by a clean-up step based on solid-phase extraction (SPE). Method validation was performed in accordance with European Union guidelines. The European Union criteria (recovery 70–120%, RSD <20%) were met for majority of pesticides. For most of the pesticides, signal-to-noise ratios were good and background-corrected mass spectra often contained sufficient diagnostic to enable identity and confirmation. The limits of quantification (LOQs) were in the range 0.01–1.0 mg/kg. The above method was successfully applied to the analysis of peach samples (n = 30) from the field. Pesticide concentration in real peach samples was compared with the maximum residue levels (MRLs). Pesticide residues were detected in 73% of the peach samples. Most frequent residues were metalaxyl, α-cypermethrin, azoxystrobin, dimethoate, tebuconazol, λ-cyhalothrin and spiromesifin in peach samples.  相似文献   

15.
A novel device, membrane extraction with a sorbent interface (MESI) coupled with a portable gas chromatograph (GC) system, has been developed. The main components of this system include a membrane module, a microtrap, and a control unit for the heater and cooler. The membrane module, as an on-line sample-introduction device for this system, can be manipulated in different configurations, allowing for the selective permeation of analytes across the membrane into the carrier/stripping gas. The analytes are trapped and concentrated onto a microtrap, which serves as an injector for gas chromatography separation. A concentration pulse of the trapped analytes is generated through direct electrical heating of the microtrap. The characteristics of this system have been explored, and its applicability and effectiveness have been demonstrated in field monitoring applications including the analysis of toluene in wastewater, Volatile organic compounds (VOCs) in laboratory air, and chloroform in swimming-pool water. This system is very promising, as it is a simple, fast, and portable tool for on-site process environmental monitoring.  相似文献   

16.
Giordano A  Richter P  Ahumada I 《Talanta》2011,85(5):2425-2429
The rotating disk sorptive extraction (RDSE) technique was applied to the determination of pesticides in aqueous samples. Pesticides of different polarities were considered in this study: chlorpyrifos, diazinon, fenvalarate, cyhalothrin, cypermethrin, lindane and malathion. The sorptive/desorptive behavior of the pesticides was studied using a rotating disk containing a polydimethylsiloxane (PDMS) phase on one of its surfaces. The analyte polarity was a significant factor in the extraction time; shorter extraction times were required for the more apolar pesticides. The optimum variables for the extraction of all analytes were: extraction time of 3 h, sample volume of 25 mL, rotational velocity of the disk 1250 rpm, desorption time of 30 min using methanol. For pesticides with values of Log Kow > 4, the extraction time can be reduced to 30 min for a quantitative extraction. Under these conditions, recoveries between 76% and 101% were obtained for the target pesticides, and the repeatability of the methodology, expressed as relative standard deviation, was determined to be between 10% and 20%. Additionally, the limits of detection of the analytes were lower than 3.1 μg L−1. The extraction method developed using the RDSE was compared to a stir bar sorptive extraction (SBSE) under the same conditions. It can be observed that the extraction using the rotating disk offers higher recoveries because of its higher PDMS volume and its higher surface area to volume ratio that allows for improved mass transfer.  相似文献   

17.
Two isothermal soot oxidation protocols were tested in a Perkin-Elmer TGA6: (1) the sample was heated under N2 and then the reaction gas was introduced and (2) the sample was introduced after the empty furnace was heated under the reaction gas. The first protocol is common in soot oxidation studies, it gives a measure of the volatiles and is easier to handle, but as it is shown the determined reaction rate may be falsified by the O2 concentration. Using gas analysis it was found that ∼2000 s are necessary for the complete gas change in the instrument. An instrument specific correction function involving the O2 concentration and reaction order n with respect to O2 was developed which allowed the correlation of the rates measured with both protocols.  相似文献   

18.
Miniaturised ultrasonic solvent extraction procedure was developed for the determination of selected polychlorinated biphenyls (PCBs) in soil samples by gas chromatography-mass-selective detection by using 23 factorial experimental design. Recoveries of PCBs from fortified soil samples are over 90% for three different fortification levels between 40 and 120 μg kg−1, and relative standard deviations of the recoveries are below 7%. The limits of detection (LODs) ranged from 0.003 to 0.006 μg kg−1. The performance of the proposed method was compared to traditional shake flask extraction method on the spiked real soil sample and extraction methods showed comparable efficiencies. Proposed miniaturised ultrasonic solvent extraction offers several advantages, i.e., reducing sample requirement for measurement of target compound, less solvent consumption and reducing the costs associated with solvent purchase and waste disposal.  相似文献   

19.
A multiresidue method for the determination of more than 80 pesticides in water has been developed and validated. The proposed method is based on SPE followed by GC coupled to MS/MS. Different variables affecting SPE procedure, such as cartridges, sample volume and solvents were studied, and mass spectrometric conditions were optimised in order to increase selectivity and sensitivity. Calibration curves were linear over the range of 0.03-0.5 microg/L. Recoveries were in the range of 70-110% and repeatability was below 20% for the lowest calibration point. LODs ranged from 0.001 to 0.025 microg/L and LOQs from 0.003 to 0.076 microg/L. Finally, the method was successfully applied to the analysis of water samples from southeast of Spain.  相似文献   

20.
Zhang Y  Yang J  Shi R  Su Q  Yao L  Li P 《Journal of separation science》2011,34(14):1675-1682
A method was developed to determine eight acetanilide herbicides from cereal crops based on accelerated solvent extraction (ASE) and solid-phase extraction (SPE) followed by gas chromatography-electron capture detector (GC-ECD) analysis. During the ASE process, the effect of four parameters (temperature, static time, static cycles and solvent) on the extraction efficiency was considered and compared with shake-flask extraction method. After extraction with ASE, four SPE tubes (graphitic carbon black/primary secondary amine (GCB/PSA), GCB, Florisil and alumina-N) were assayed for comparison to obtain the best clean-up efficiency. The results show that GCB/PSA cartridge gave the best recoveries and cleanest chromatograms. The analytical process was validated by the analysis of spiked blank samples. Performance characteristics such as linearity, limit of detection (LOD), limit of quantitation (LOQ), precision and recovery were studied. At 0.05 mg/kg spiked level, recoveries and precision values for rice, wheat and maize were 82.3-115.8 and 1.1-13.6%, respectively. For all the herbicides, LOD and LOQ ranged from 0.8 to 1.7 μg/kg and from 2.4 to 5.3 μg/kg, respectively. The proposed analytical methodology was applied for the analysis of the targets in samples; only three herbicides, propyzamid, metolachlor and diflufenican, were detected in two samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号