共查询到20条相似文献,搜索用时 0 毫秒
1.
Jiangman Liu 《Analytical letters》2013,46(11):1804-1815
A sensitive method for the determination of total chromium in real samples by flow injection–chemiluminescence (FI–CL) analysis was proposed. It was found that the CL intensity from luminol–lysozyme reaction could be markedly quenched, and the decrease of CL intensity was linear with the logarithm of Cr(III) concentrations over the range of 5.0 to 4000 pg mL?1 with a detection limit of 2.0 pg mL?1 (3σ) and relative standard deviations (RSDs) of 3.0, 2.6, and 2.0% for 10, 100, and 1000 pg mL?1 Cr(III) (n = 7), respectively. At a flow rate of 2.0 mL min?1, the whole process including sampling and washing could be accomplished within 36 s. The proposed CL method was successfully applied to the determination of total chromium in pharmaceutical capsules, a dietary supplement, and spiked human serum samples, with recoveries from 92.2 to 108.4% and RSDs of less than 4.0%. Using the homemade FI–CL model, the binding constant (K = 4.38 × 106 L mol?1) and the binding sites (n ≈ 1) of Cr(III) to lysozyme were given. 相似文献
2.
A simple, rapid and sensitive method for the determination of chromium(III) and total chromium using the simple dual T channels on glass chip with negative pressure pumping system and chemiluminescence (CL) detection is presented. The CL reaction was based on luminol oxidation by hydrogen peroxide in basic aqueous solution catalyzed by chromium(III). Total chromium in form of chromium(III) was achieved after chromium(VI) was completely reduced by acidic sodium hydrogen sulfite. Total chromium could then be determined with the same strategy as the chromium(III). The CL reagent was composed of 1.0 × 10−4 mol/L luminol, 1.0 × 10−2 mol/L hydrogen peroxide and 0.10 mol/L sodium bromide in 0.050 mol/L carbonate buffer (pH 11.00). The 1.0 × 10−2 mol/L ethylenediaminetetraacetic acid was added into the sample solution in order to improve the selectivity. Chromium(III) could be detected at a notably concentration of 1.6 × 10−16 mol/L and a linear calibration curve was obtained from 1.0 × 10−15 to 1.0 × 10−13 mol/L. The sample and CL reagent consumption were only 15 and 20 μL, respectively. The analysis time was less than 1 min per sample with the precision (%R.S.D.) was 4.7%. The proposed method has been applied successfully to the analysis of river water, mineral waters, drinking waters and tap water. Its performance was verified by the analysis of certified total chromium-reference materials and by recovery measurement on spiked synthetic seawater sample. 相似文献
3.
Zi Gang XU* Xian Hong WEN Qing Zhou WU Center of Analysis & Testing Zhejiang University Hangzhou 《中国化学快报》2001,(7)
There is little conclusive evidence of the toxic effects of Cr(III) so far, but Cr(VI) has carcinogenic activity, so the analysis of the chromine ions is very important in environmental research and the quality control of industry products. Usually Cr(III) and Cr(VI) interfere with each other in the species analysis, the measurement of Cr(VI) of numerous previous papers is related to the Cr(VI) samples, which contain a little Cr(III). When the amount of trivalent chromine exceeds ten … 相似文献
4.
《Electroanalysis》2003,15(19):1513-1521
The complexation of Cr(III) and Cr(VI) with diethylenetriaminepentaacetic acid (DTPA), the redox behavior of these complexes and their adsorption on the mercury electrode surface were investigated by a combination of electrochemical techniques and UV/vis spectroscopy. A homogenous two‐step reaction was observed when mixing Cr(III), present as hexaquo complex, with DTPA. The first reaction product, the electroactive 1 : 1 complex, turns into an electroinactive form in the second step. The results indicate that the second reaction product is presumably a 1 : 2 Cr(III)/DTPA complex. The electroreduction of the DTPA‐Cr(III) complex to Cr(II) was found to be diffusion rather than adsorption controlled.The Cr(III) ion, generated in‐situ from Cr(VI) at the mercury electrode at about ?50 mV (vs. Ag|AgCl) (3 mol L?1 KCl), was found to form instantly an electroactive and adsorbable complex with DTPA. By means of electrocapillary measurements its surface activity was shown to be 30 times higher than that of the complex built by homogenous reaction of DTPA with the hydrated Cr(III). Both components, DTPA and the in‐situ built complex Cr(III) ion were found to adsorb on the mercury electrode.The effect of nitrate, used as catalytic oxidant in the voltammetric determination method, on the complexation reaction and on the adsorption processes was found to be negligible.The proposed complex structures and an overall reaction scheme are shown. 相似文献
5.
《Analytical letters》2012,45(8):1366-1374
Abstract Chemiluminescence reaction of the system containing europium(III) ion, KMnO4, Na2SO3, and ibuprofen was investigated for the determination of ibuprofen. The introduction of Eu(III) ion into the system of KMnO4-Na2SO3-ibuprofen caused a significant increase in the chemiluminescence signal. The increment of the chemiluminescence signal is proportional to ibuprofen concentration in the range of 5.0 × 10?8–5.0 × 10?6 g/ml with a detection limit of 1 × 10?8 g/ml. The relative standard deviation for 1.0 × 10?7 g/ml ibuprofen solution was 1.7% (n = 11). The proposed method was successfully applied to determine ibuprofen in tablets and human plasma. 相似文献
6.
Summary A method for simultaneous determination of Cr(III) and Cr(VI), using sodium diethyldithiocarbamate as chelating agent is given. At room temperature and pH 5.8 sodium diethyldithiocarbamate reacts with both Cr(III) and Cr(VI). Examination of this reaction by reversed phase high-performance liquid chromatography, makes it possible to correct for the interference between Cr(III) and Cr(VI) when determining the amount of Cr(III) present in the solution. 相似文献
7.
Raúl A. Sánchez-Moreno Ma Teresa Sevilla Jesús R. Procopio 《Analytica chimica acta》2009,634(1):68-74
A new and easy device for direct detection of chromium(III) in batch and flow analysis without previous oxidation/reduction or preconcentration steps of samples is designed and evaluated. For this purpose a potentiometric sensor with solid state membrane based on carbon paste matrix is developed. The sensor is modified with di(2-hydroxyphenylimino)ethane and the principal analytical parameters of the potentiometric response in batch and flow analysis are optimized and calculated. Optimal detection limits (1.4 × 10−7 M in static mode and 5.4 × 10−7 M in on-line analysis) and selectivity to trivalent chromium are obtained in both analysis modes. The use of this device to direct detection of chromium(III) in real samples is tested using a sediment Certified Reference Material. Chromium(III) determination is also carried out with successful results in environmental samples such as extracts from soils used as barriers in landfills and industrial samples such as waste waters from electroplating industries. 相似文献
8.
Determination of bisphenol A based on chemiluminescence from gold(III)-peroxymonocarbonate 总被引:1,自引:0,他引:1
Peroxymonocarbonate (HCO4−) was produced by the online reaction of bicarbonate with hydrogen peroxide. A strong chemiluminescence (CL) was observed when HCO4− reacted with AuCl4− without any special CL reagent. When bisphenol A (BPA) was added to AuCl4−-HCO4− CL system, the CL emission was inhibited significantly. This new CL system was developed as a flow-injection method for the determination of BPA. Under the optimum experimental conditions, the inhibited CL intensity was linearly related to the concentration of BPA from 0.3 to 80 μM (R = 0.9958). The detection limit of BPA was 0.08 μM. The relative standard deviation for 12 repeated measurements of 1.0 μM BPA was 2.9%. The interferences of some cationic ions can be removed by an online cation-exchange column. The applicability of the present CL system was demonstrated for the sensitive and selective determination of BPA in real samples (mineral water bottle, baby bottle, beverage bottle and polycarbonate container). Based on the CL spectrum, UV-visible adsorption spectra, and the quenching effect of reactive oxygen species scavengers, a possible CL mechanism was proposed. 相似文献
9.
《Journal of Coordination Chemistry》2012,65(22):2471-2483
The kinetics of oxidation of the chromium(III) complexes, [Cr(Ino)(H2O)5]3+ and [Cr(Ino)(Gly)(H2O)3]2+ (Ino?=?Inosine and Gly?=?Glycine) involving a ligands of biological significance by N-bromosuccinimide (NBS) in aqueous solution to chromium(VI) have been studied spectrophotometrically over the 25–45°C range. The reaction is first order with respect to both [NBS] and [Cr], and increases with pH over the 6.64–7.73 range in both cases. The experimental rate law is consistent with a mechanism in which the hydroxy complexes [Cr(Ino)(H2O)4(OH)]2+ and [Cr(Ino)(Gly)(H2O)2(OH)]+ are significantly more reactive than their conjugate acids. The value of the intramolecular electron transfer rate constant, k 1, for the oxidation of the [Cr(Ino)(H2O)5]3+ (6.90?×?10?4?s?1) is lower than the value of k 2 (9.66?×?10?2?s?1) for the oxidation of [Cr(Ino)(Gly)(H2O)2]2+ at 35°C and I?=?0.2?mol?dm?3. The activation parameters have been calculated. Electron transfer apparently takes place via an inner-sphere mechanism. 相似文献
10.
Sibel Yalçin 《Analytica chimica acta》2004,505(1):25-35
Chromium may exist in environmental waters as Cr(III) and Cr(IV), the latter being the toxic and carcinogenic form. Since atomic absorption spectrometry (AAS) and inductively coupled plasma atomic emission spectrometry can only yield information on total Cr concentration, a polymer resin bearing O,O-donor chelating groups such as the maleic acid-functionalized XAD(CO)CHCHCOOH resin was synthesized to selectively retain Cr(III) at pH 4.0-5.5. The dynamic breakthrough capacity of the resin for Cr(III) at pH 5.0 was 7.52 mg g−1, and the preconcentration factor extended to 250-300. Chromium(III) in the presence of 250-fold Cr(VI)—which was not retained—could be effectively preconcentrated on the NH4+-form of the resin and determined by AAS or diphenylcarbazide (DPC) spectrophotometry. When Cr(VI) was reduced to Cr(III) with Na2SO3 solution brought to pH 1 by the addition of 1 M H2SO4, and preconcentrated on the resin, total Cr could be determined. The developed method was validated with a blended coal sample CRM-1632. Since the adsorption behavior as a function of pH of possible interferent metal ions, e.g. Ni(II), Co(II), Cu(II), Cd(II), Zn(II), Pb(II) and Fe(III), was similar to that of Cr(III), selective elution of Cr(III) from the resin was realized using a mixture of 1 wt.% H2O2+1 M NH3. The eluate containing Cr as chromate could be directly analyzed by diphenyl carbazide spectrophotometry without any adverse effect from the common interferents of this method, i.e. Fe(III), Cu(II) Hg(II), VO3−, MoO42− and WO42−. Various synthetic waste solutions typical of electroplating bath effluents containing Cr, Cu, Ni, Zn, Na, Ca, cyanide (and chemical oxidation demand (COD), achieved by glucose addition) were subjected to pretreatment procedures such as hypochlorite oxidation (of cyanide) and catalytic oxidation (of COD) with peroxodisulfate. Chromium determination gave satisfactory results. The combined column preconcentration—selective elution—diphenylcarbazide spectrophotometric determination was also successfully applied to the determination of Cr in artificial and real seawater. 相似文献
11.
《Analytical letters》2012,45(3):605-612
Abstract Chromium (VI) can oxidize and decolor three colour reagents, i.e. 1,8-dihydroxy-2-(4′-chloro-2′-phosphonophenylazo)-7-(6″.8″-disulfonaphthylazo)-3,6-disulfonaphthalene (RI): 1,8-dihydroxy-2-(4′-chloro-2′-phosphonophenylazo)-7-(4″-sulfonamidephenylazo)-3,6-disulfonaphthalene (RII): and 1,8-dihydroxy-2-(4′-chloro-2′-phosphonophenylazo)-7-(p-hippuric acid azo)-3,6-disulfonaphthalene (RIII). Loss of absorbance of three colour reagents at maximum absorption wavelengths is proportional to the concentration of chromium (VI) in solution. We have made use of the decolorization reactions between chromium (VI) and three colour reagents to determine chromium in steel by flow injection analysis, and relative error in sample determination is less than 5.0%. Response is linear from 0.84 to 6.72 μg/mL and optimum measuring acidity is 1.3–1.7 mol/L H2SO4 in three systems. The effect of interference ions on determination has been studied. 相似文献
12.
AHMED Khan MUHAMMAD Asghar MOHAMMED Yaqoob MASOOD Ahmed Siddiqui SAMAR Ali 《高等学校化学研究》2021,37(3):629-638
Asensitive and selective method employing chemiluminescence(CL) coupled with flow injection(FI) is reported for nalbuphine hydrochloride(NAL) assay in pharmaceutical formulations. The enhancement effect of NAL on the CL reaction between tris(2,2'-bipyridyl)ruthenium(II) chloride-diperiodatocuprate(III) {Ru[(bpy)3]2+-Cu(III) complex} in acidic medium is used as analytical measurement. The optimal conditions of the CL reaction were sulfuric acid 1.0×10-3 mol/L, Ru[(bpy)3]2+ 7.5×10-5 mol/L, Cu(III)/Ag(III) complexes 4.0×10-4/5.0×10-4 mol/L, sample loop volume of 120 μL and flow rate of 2.5 mL/min. The sensitivities of the method in terms of detection(S/N=3) and quantification(S/N=10) limits are 5×10-4 and 0.001 ppm(1 ppm=1 mg/L), respectively. The linear response of the instrument in the form of CL intensity with respect to NAL concentration is over the range 0.001-15.0 ppm(R2=0.9999) with relative standard deviation from 0.8% to 3.2% and injection throughput of 120 injection/h. The applications of the method include the quantitative analysis of NAL in pharmaceutical injection samples. Variations and the average results of the proposed method are not signi-ficantly different from the results of a reported method by applying F- and paired student t-test. The most likely CL reaction mechanism is written in accordance with spectrophotometric and CL studies. 相似文献
13.
神经生长因子的化学发光标记与检测 总被引:1,自引:0,他引:1
以辣根过氧化物酶(HRP)和吖啶酯(AE)为化学发光标记试剂分别标记神经生长因子(NGF)单克隆抗体,经分离纯化制成标记抗体(HRP-Ab,AE-Ab),采用化学发光免疫分析法(CLIA)对NGF进行检测,其检出限为0.5ng/mL,线性范围为2~128ng/mL.10例样本分别用CLIA和RIA进行检测,其结果无显著性差异. 相似文献
14.
A poly(vinyl chloride) membrane based on glyoxal bis(2-hydroxyanil) as membrane carrier was prepared and investigated as a Cr(III)-selective electrode. The electrode has a linear dynamic range of 3.0×10−6-1.0×10−2 mol l−1, with a Nernstian slope of 19.8±0.5 mV per decade and a detection limit of 6.3×10−7 mol l−1. It has a fast response time of <20 s and can be used for at least 3 months without any considerable divergence in potential. The proposed electrode revealed good sensitivities for Cr(III) over a wide variety of metal ions and could be used in a pH range of 2.7-6.5. Above all, the membrane sensor has been used very successfully for the analysis of some food materials and alloys for the determination of Cr(III) ion. 相似文献
15.
Summary. A new selective, sensitive, and simple kinetic method is developed for the determination of trace amounts of chromium (VI). The method is based on the catalytic effect of Cr(VI) on the reaction of sodium pyrogallol-5-sulphonate (PS) with hydrogen peroxide. The reaction is followed spectrophotometrically by tracing the oxidation product at 437nm within 1min after addition of H2O2. The optimum reaction conditions are PS (1.32·10–3mol·dm–3), H2O2 (0.32mol·dm–3), HClO4 (2.6·10–3mol·dm–3) at 25°C. Following this procedure, chromium (VI) can be determined with a linear calibration graph up to 0.25ng·cm–3 and a detection limit of 0.024ng·cm–3, based on the 3 criterion. The interference effect of several species was also investigated and it was found that the most common cations and anions do not interfere with the determination. The developed procedure was successfully applied to the determination of Cr(VI) and total Cr in river waters and total Cr in herbal samples. 相似文献
16.
Electromembrane extraction (EME) is a powerful extraction and preconcentration technique for ionizable species. However, the ionic contents in the sample can influence the extraction efficiency and system stability due to electrolysis. In this work, the electromembrane extraction of chromium(VI) was developed using various levels of ionic samples. 2-Nitrophenyl octyl ether was the most suitable supported liquid membrane that delayed the electrolytic occurrence of air bubbles at the electrodes due to its high viscosity and high dielectric constant properties. The electromembrane extraction method was optimized using 5?mM NaCl (630?µS?cm?1); the applied potential was 100?V and the extraction time was 15?min. The enrichment factor of 80 was obtained over a linear working range of 10.0–80.0?µg?L?1. The method performance was tested using mineral water, drinking water, tap water, and surface water. The method recoveries based on matrix-matched calibration were 95–125% with standard deviations within 15%. 相似文献
17.
Speciation of Cr(III) and Cr(VI) can be attained by flow injection analysis with amperometric detection. Cr(VI) is reduced in an acidic medium to Cr(III) with a glassy carbon electrode at —0.1 V vs. Ag/AgCl and the current is recorded. Cr(III) is oxidised on-line to Cr(VI) with alkaline hydrogen peroxide solution. From the difference of the total chromium and Cr(VI), the amount of Cr(III) was obtained. A linear calibration curve for Cr(VI) was obtained for the concentration ranges 0.01-5.0ppm of Cr(VI) and we have calculated the limit of determination to be about 0.5ppb. We have studied the degree of reproducibility obtained using the solid electrodes under various conditions. The influence of flow rate, coil length, interfenences and the extent of reaction were studied. 相似文献
18.
Mono- and Dinuclear Fluoro Complexes of Titanium (III), Chromium (III), and Iron(III). Syntheses and Structures of (NMe4) (Ti(H2O)4F2)TiF6 · H2O, (NMe4)3Cr2F9, and (NMe4)3Fe2F9 The title compounds have been prepared by reaction of MCl3 (M = Ti, Cr, Fe) with NMe4F in dimethylformamide. (NMe4)3Cr2F9 and (NMe4)3Fe2F9 contain the face-sharing biocathedral M2F93? unit. The M…M distances are 277.1(1) and 289.8(3) pm in (NMe4)3Cr2F9 and (NMe4)Fe2F9, respectively. (NMe4)(Ti(H2O)4F2)TiF6 · H2O contains trans-TiIII(H2O)4F2+ cations and TiIVF62? anions. Crystal data: (NMe4)3Cr2F9: hexagonal, space group P63/m, a = 804.1(3), c = 1857.5(4) pm, Z = 2, 529 reflections, R = 0.049; (NMe4)3Fe2F9: hexagonal, space group P63/m, a = 804.7(5), c = 1 861.6(5) pm, Z = 2, 635 reflections, R = 0,046; (NMe4)(Ti(H2O)4F2)TiF6 · H2O: orthorhombic, space group Pbca, a = 776.9(2), b = 1 616.3(3), c = 2 428.6(7) pm, Z = 8, 2 784 reflections, R = 0,056. 相似文献
19.
A facile, reliable and reproducible method for speciation and determination of the traces amounts of chromium(III) in waste water has been developed. The method was based on complex formation on the surface of the ENVI‐18 DSK? disks followed by stripping of the retained species by minimum amounts of appropriate organic solvents. The elution was efficient and quantitative. The effects of potential interfering ions, pH, ligand amount, stripping solvent, and sample flow rate were also investigated. Under the optimal experimental conditions, the break‐through volume was found to be about 1500 mL providing a preconcentration factor of 300. The maximum capacity of the disks was found to be 225 ± 3.9 μg for Cr3+. A limit of detection of 0.02 ng.mL ?1 was obtained, and the method was applied for determination of chromium in electroplating industries waste water located in the eastern regions of Tehran. 相似文献
20.
Wei DENG Wei Ping YANG Zhu Jun ZHANG* Xiao Rong LI College of Chemistry Materials Science Shaanxi Normal University Xi抋n 《中国化学快报》2003,14(3)
Chromiumexistsindifferentoxidationstatesingroundwater,industrialwastewater,seawater,andsoilofourenvironment1,2.Chromium(III)isanessentialtraceelementforhumans,requiredforthemaintenanceofnormalglucose,cholesterol,andfattyacidmetabolism.Ontheotherhand,watersolublechromium(VI),intheformCr2O72-orCrO42-,ishighlyirritatingandtoxictohumansandanimals3.Itsacutetoxiceffectsincludeanimmediatecardiovascularshockandlatereffectsonkidney,liver,andblood-formingorgans.Therefore,itisnecessaryforriskassessme… 相似文献