首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 250 毫秒
1.
We constructed a preparative instrumentation and developed the methods that are based on separation of the samples by bidirectional isotachophoresis/moving boundary electrophoresis in continuous divergent flow. The described instrumentation can be used for a variety of the samples, however, it can be easily optimized and tailored for the specific sample. The trapezoid separation bed from nonwoven textile exhibited minimum adsorption effect for sample and it can be used repeatedly. By the addition of different spacers via separation space inlets, the sections of pH gradient can be modified to enhance the separation. The liquid flow from two inlets positioned on each side of the sample inlet prevented the contact of the sample with anolyte and catholyte at the analysis beginning. One pair of thin electrodes (graphite and stainless-steel) was placed at the separation space output. The electrode products were washed out into drains without disturbing the focusing process. The influence of EOF was managed by tilting the separation bed in the direction from cathodic to anodic side. The components of spirulina supernatant and color pI markers were separated in the pH gradient from 3.9 to 10.1. pH gradient was stable for at least 4.5 h and spirulina supernatant from about 0.12 g of dry powder was processed. Compared to other preparative methods used for spirulina separation, the presented method/instrumentation working with a continuous divergent flow had essential advantages. The efficient separation was fast, and no intermediate steps were necessary to obtain liquid fractions with separated components compatible with further biological experiments.  相似文献   

2.
毛细管等电聚焦和电渗泵驱动聚焦区带分离蛋白质   总被引:4,自引:0,他引:4  
建立了一种利用电渗泵驱动毛细管内的聚焦区带,实现毛细管电泳等电聚焦分离蛋白质的方法。通过控制电压来调节泵的输出流量,从而调节聚焦区带的迁移速度。适用于毛细管电泳等电聚焦两步法分离蛋白质等两性物质。考察了对牛血清白蛋白和溶菌酶两种粗提蛋白质混合物的分离,迁移时间的RSD分别为1.6%和1.3%,峰面积的RSD均为1.6%,证明方法可行。  相似文献   

3.
This study concentrates on development of instrumentation for focusing and separation of analytes in continuous flow. It is based on bidirectional ITP working in wide pH range with separation space of closed void channel of trapezoidal shape and continuous supply of sample. The novel instrumentation is working with electrolyte system formulated previously and on the contrary to devices currently available, it allows preparative separation and concentration of cationic, anionic, and amphoteric analytes simultaneously and in wide pH range. The formation of sharp edges at zone boundaries as well as low conductivity zones are avoided in suggested system and thus, local overheating is eliminated allowing for high current densities at initial stages of focusing. This results in high focusing speed and reduction of analysis time, which is particularly advantageous for separations performed in continuous flow systems. The closed void channel is designed to avoid basic obstacles related to liquid leakage, bubbles formation, contacts with electrodes, channel height and complicated assembling. The performance of designed instrumentation and focusing dynamics were tested by using colored low molecular mass pH indicators for local pH determination, focusing pattern, and completion. In addition, feasibility and separation efficiency were demonstrated by focusing of cytochrome C and myoglobin. The collection of fractions at instrument output allows for subsequent analysis and identification of sample components that are concentrated and conveniently in form of solution for further processing. Since the instrumentation operates with commercially available simple defined buffers and compounds without need of carrier ampholytes background, it is economically favorable.  相似文献   

4.
This paper describes a microfabricated free-flow electrophoresis device with integrated ion permeable membranes. In order to obtain continuous lanes of separated components an electrical field is applied perpendicular to the sample flow direction. This sample stream is sandwiched between two sheath flow streams, by hydrodynamic focusing. The separation chamber has two open side beds with inserted electrodes to allow ventilation of gas generated during electrolysis. To hydrodynamically isolate the separation compartment from the side electrodes, a photo-polymerizable monomer solution is exposed to UV light through a slit mask for in situ membrane formation. These so-called salt-bridges resist the pressure driven fluid, but allow ion transport to enable electrical connection. In earlier devices the same was achieved by using open side channel arrays. However, only a small fraction of the applied voltage was effectively utilized across the separation chamber during free-flow electrophoresis and free-flow isoelectric focusing. Furthermore, the spreading of the carrier ampholytes into the side channels resulted in a very restricted pH gradient inside the separation chamber. The chip presented here allows at least 10 times more efficient use of the applied potential and a nearly linear pH gradient from pH 3 to 10 during free-flow isoelectric focusing could be established. Furthermore, the application of hydrodynamic focusing in combination with free-flow electrophoresis can be used for guiding the separated components to specific chip outlets. As a demonstration, several standard fluorescent markers were separated and focused by free-flow zone electrophoresis and by free-flow isoelectric focusing employing a transversal voltage of up to 150 V across the separation chamber.  相似文献   

5.
液固流化床内床层动态特性的CFD模拟   总被引:1,自引:0,他引:1  
在对液固流化床内流动特性进行理论分析的基础上,采用多相流CFD方法模拟了二维矩形流化床内水和玻璃球体系的流体动力学特性。实验结果表明,流体速度突变后,液固流化床从一个平衡状态向另一个平衡状态过渡。当液体速度减小时,床层表面及分隔界面的变化与理论模型预测一致;由于重力不稳定性的影响,当液体速度增大时,床层表面稳定上升但与时间不呈线性关系,且分隔界面难以分辨。进而膨胀后停留时间的长短对收缩过程的影响也可以忽略。尽管床层收缩时间明显小于实际膨胀时间,但是与预报的理想膨胀时间比较接近。模拟结果与前人的实验研究和理论分析相吻合,表明多相流CFD模拟可以很好地预测液固流化床的床层动态行为。  相似文献   

6.
Immunoglobulins in bovine colostrum were separated and fractionated from other proteins using the method and instrumentation developed in our laboratory. The proposed separation was based on bidirectional isotachophoresis/moving boundary electrophoresis with electrofocusing of the analytes in a pH gradient from 3.9 to 10.1. The preparative instrumentation included the trapezoidal non-woven fabric that served as separation space with divergent continuous flow. The defatted and casein precipitate-free colostrum supernatant was loaded directly into the instrument without any additional colostrum pre-preparation. Immunoglobulin G was fractionated from other immune proteins such as bovine serum albumin, β-lactoglobulin, and α-lactalbumin, and was continuously collected in separated fractions over 3 h. The fractions were further processed, and isolated immunoglobulin G in the liquid fractions was confirmed by sodium dodecyl sulfate-polyacrylamide gel electrophoresis and by re-focusing in gel isoelectric focusing. Separated immunoglobulin G was detected in seven fractions by sodium dodecyl sulfate-polyacrylamide gel electrophoresis with a gradually decreased concentration in the fractions. Re-focusing of the proteins in the fractions by gel isoelectric focusing revealed multiple separated zones of immunoglobulin G with the isoelectric point values covering the range from 5.4 to 7.2. Each fraction contained distinct zones with gradually increased isoelectric point values and decreased concentrations from fraction to fraction.  相似文献   

7.
Electromobility focusing (EMF) is a relatively new protein separation technique that utilizes an electric field gradient and a hydrodynamic flow. Proteins are focused in order of electrophoretic mobility at points where their electrophoretic migration velocities balance the hydrodynamic flow velocity. Steady state bands are formed along the separation channel when equilibrium is reached. Further separation and detection can be easily achieved by changing the electric field profile. In this paper. we describe an EMF system with on-line UV absorption detection in which the electric field gradient was formed using a dialysis hollow fiber. Protein focusing and preconcentration were performed with this system. Voltage-controlled separation was demonstrated using bovine serum albumin and myoglobin as model proteins. The limitations of the current method are discussed, and possible solutions are proposed.  相似文献   

8.
Graphene oxide nanosheets often bear a wide size distribution. However, it is critical to have nanosheets with narrow size distribution for their unique size‐dependent physiochemical properties, and nanosheets with a narrow size distribution are the cornerstones for application. Therefore, efficient separation methods of graphene nanosheets have been given considerable attention in many scientific areas recently. Free‐flow electrophoresis is extensively used in the separation and purification of biological molecules with continuous flow separation. The charged graphene oxide nanosheets to some extent are very close in size to biological molecules and share similarity in motion behavior in an electric field. Thus, in the present work, we present a new and simple means to separate graphene oxide nanosheets into more mono‐dispersed size groups by using the free‐flow electrophoresis technique. By optimizing the separation conditions, we were able to obtain graphene oxide sheets with narrow size distribution. The separated samples were characterized by atomic force microscopy, and the size measurements were made by using the software “Image Pro Plus.” In addition, a brief discussion is also given into the theoretic background of the separation of graphene oxide according to the size by the technique of preparative free‐flow electrophoresis.  相似文献   

9.
新型毛细管等电聚焦驱动方法的建立及其应用   总被引:2,自引:0,他引:2  
毛细管等电聚焦(CIEF)在生物分离分析领域中的发展迅速.CIEF可分为两步法聚焦和一步法聚焦.电渗流(EOF)可作为一种新的驱动力.Rassi等根据串连体系中电渗流速率将被平均化的原理,将未涂层毛细管与聚乙二醇涂层的毛细管通过聚四氟乙烯管耦合起来,成功地利用毛细管区带电泳快速分离蛋白.此外,利用电渗流输液原理设计的电渗泵还可用作流动注射和微柱液相色谱的驱动系统。  相似文献   

10.
11.
12.
陈东英  林华水 《电化学》1997,3(2):139-142
基于电迁移率差异而分离的新型聚焦电泳技术①陈东英林华水周勇亮毛秉伟谢兆雄卓向东田昭武*(固体表面物理化学国家重点实验室及化学系厦门大学厦门361005)毛细管区带电泳已成为十几年来发展最快的分离分析技术.Hjertén于1967年在玻璃管中进行了自由...  相似文献   

13.
新型固定化pH梯度毛细管等电聚焦方法用于蛋白分离   总被引:1,自引:0,他引:1  
通过化学键合建立一种固定化pH梯度的方法,用于毛细管等电聚焦分离蛋白质.采用微流控泵驱动毛细管内的聚焦区带,通过调节泵的流量,从而调节聚焦区带的迁移速度.该方法避免了自由溶液聚焦时两性电解质所带来的影响,实现了高灵敏度及检测波长自由选择等优点,适用于两步法毛细管电泳等电聚焦分离蛋白质等两性电解质.本文考察了对牛血清白蛋白和血红蛋白两种蛋白质混合物的分离,证明了该方法可行.  相似文献   

14.
Stastná M  Slais K 《Electrophoresis》2005,26(18):3586-3591
Two-dimensional gel isoelectric focusing (2-D gel IEF) is presented as the combination of the same separation method used consecutively in two directions of the same gel. In this new method, after completion of IEF process in the first dimension the gel was cut into the separate strips, each containing selected analytes together with the appropriate part of the original broad pH gradient, and the strips were rotated by 90 degrees (with regard to the first IEF) and left to diffuse overnight. After diffusion the strips were subjected to the second IEF. During the second IEF, the corresponding narrow part of pH gradient in each strip was restored again, however, now along the strip. The progress of the separation process can be monitored visually by using colored low-molecular-weight isoelectric point (pI) markers loaded into the gel simultaneously with proteins. The unique properties of IEF, focusing and resolution power were enhanced by using the same technique twice. Two forms of beta-lactoglobulin (pI values 5.14 and 5.31, respectively) non-separated in the first IEF were successfully separated in the second dimension at relatively low voltage (330 V) with the resolution power comparable to the high-resolution gels requiring the high voltage during the run and long separation time. Glucose oxidase loaded as diluted solution into ten positions across the gel was finally focused into a single band during 2-D gel IEF. Since the first and second IEF are carried out on the same gel, no losses and contamination of analyte occur. The suggested method can be used for separation/fractionation of complex biological mixtures, similarly as other multidimensional separation techniques applied in proteomics, and can be followed by further processing, e.g., mass spectrometry analysis. The focusing properties of IEF could be useful especially in separation of mixtures, where components are at low concentration levels.  相似文献   

15.
Simulated moving bed (SMB) chromatography combines high productivity and high purities with reduced buffer consumption. We have developed a laboratory scale single column SMB (SC-SMB) unit with all four separation zones in one column. Distributors embedded within the chromatographic medium allow introduction and withdrawal of liquid between the zones. This single column unit exhibits homogenous packing in all zones, reduced headspace, less complex tubing, fewer valves, and almost undisturbed plug flow between the separation zones. The separation performance of the column was investigated with two different binary model mixtures. Furthermore, the SC-SMB unit is operated with a modified AKTA Explorer workstation, which has been specifically developed for the handling of biological fluids.  相似文献   

16.
A two-dimensional capillary electrophoresis platform, combining isoelectric focusing (IEF) and capillary zone electrophoresis (CZE), was established on a microchip with the channel width and depth as 100 mum and 40 mum, respectively. With polyacrylamide as permanent coating, EOF in the microchannel, which could impair the separation, was decreased to 3.4x10(-9)m(2).V(-1).s(-1), about 1/10 of that obtained in the uncoated set-up. During the separation, peptides were first focused by IEF in the first dimensional channel, and then directly driven into the perpendicular channel by controlling the applied voltages, and separated by CZE. Effects of various experimental parameters, including the electric field strength, channel length, and injection frequency from the first to the second dimensional separation channel, were studied. Under optimized condition, the digests of BSA and proteins extracted from E. coli were separated, and a peak capacity of 540 was obtained, which was far greater than that obtained by each single dimensional separation. All these results showed the promise of multidimensional separation on a microchip for the high-throughput and high-resolution analysis of complex samples.  相似文献   

17.
王蕾  何友昭  王晓葵  邓宁  付国妮  高勇 《分析化学》2006,34(10):1426-1428
建立了一种基于增压电渗泵驱动、整体柱分离和紫外检测相结合的电动流动分析系统。研究了载流溶液中甲醇的体积分数对电渗泵空载流量、输出压强、移动相流量和分离度的影响。在4950V的外加电压下,以含0.5mmol/L六亚甲基四胺的45%甲醇溶液为泵载流,电渗泵的流量和输出压强分别为0.58mL/min和0.79MPa,以泵载流为流动相,该系统对苯和萘进行了反相色谱分离。电动流动分析系统设备简单、操作方便、功能多样。对苯和萘的分离结果表明,电动流动分析系统可用于样品的色谱分离。  相似文献   

18.
Abstract

It is demonstrated that mixtures containing few compounds can be applied as wide zones on the edge of the thin layer using a sandwich tank with glass distributor. The mixture is partially separated during application (frontal chromatography) so that subsequent elution accomplishes complete separation. Using 5 × 20 cm plates of silica, 0.5 mm thick, 1 - 3 ml samples were separated easily which permitted elution of 3 - 9 of separated compounds from a single plate.  相似文献   

19.
Huang T  Pawliszyn J 《Electrophoresis》2002,23(20):3504-3510
A simple microfabrication technique for the preparation of a tapered microchannel for thermally generated pH gradient isoelectric focusing (IEF) has been demonstrated. The tapered channel was cut into a plastic sheet (thickness was 120 microm), and the channel was closed by sandwiching the plastic sheet between two glass microscope slides. The length of the microchannel was 5 cm. The width of the separation channel was 0.4 mm at the narrow end and 4 mm at the wide end. The channel was coated with polyacrylamide to prevent electroosmotic flow (EOF) during focusing. Two electrolyte vials were mounted on top of each end of the channel with the wide end of the channel connected to the cathodic vial and the narrow to the anodic vial. The feasibility of the thermally generated pH gradient in a tapered channel was demonstrated. Important parameters that determined the feasibility of using a thermally generated pH gradient in a tapered channel were analyzed. Parameters to be optimized were control of EOF and hydrodynamic flow, selection of power supply mode and prevention of local overheating and air bubble formation. Tris-HCl buffer, which has a high pK(a) dependence with temperature, was used both to dissolve proteins and as the electrolyte. The thermally generated pH gradient separation of proteins was tested by focusing dog, cat and human hemoglobins with a whole column detection capillary IEF (CIEF) system.  相似文献   

20.
Choi S  Park JK 《Lab on a chip》2005,5(10):1161-1167
This paper presents a novel microfluidic device for dielectrophoretic separation based on a trapezoidal electrode array (TEA). In this method, particles with different dielectric properties are separated by the device composed of the TEA for the dielectrophoretic deflection of particles under negative dielectrophoresis (DEP) and poly(dimethylsiloxane)(PDMS) microfluidic channel with a sinuous and expanded region. Polystyrene microparticles are exposed to an electric field generated from the TEA in the microfluidic channel and are dielectrophoretically focused to make all of them line up to one sidewall. When these particles arrive at the region of another TEA for dielectrophoretic separation, they are separated having different positions along the perpendicular direction to the fluid flow due to their different dielectrophoretic velocities. To evaluate the separation process and performance, both the effect of the flow rate on dielectrophoretic focusing and the influence of the number of trapezoidal electrodes on dielectrophoretic separation are investigated. Now that this method utilizes the TEA as a source of negative DEP, non-specific particle adhering to the electrode surface can be prevented; conventional separation approaches depending on the positive DEP force suffer from this problem. In addition, since various particle types are continuously separated, this method can be easily applicable to the separation and analysis of various dielectric particles with high particle recovery and selectivity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号