首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Hilder EF  Svec F  Fréchet JM 《Electrophoresis》2002,23(22-23):3934-3953
This review summarizes the contributions of a number of groups working in the rapidly growing area of monolithic columns for capillary electrochromatography (CEC), with a focus on those prepared from synthetic polymers. Monoliths have quickly become a well-established stationary phase format in the field of CEC. The simplicity of their in situ preparation method as well as the good control over their porous properties and surface chemistries make the monolithic separation media an attractive alternative to capillary columns packed with particulate materials. A wide variety of approaches as well as materials used for the preparation of the monolithic stationary phases are detailed. Their excellent chromatographic performance is demonstrated by numerous separations of different analytes.  相似文献   

2.
This review summarizes the contributions to the rapidly growing area of monolithic columns based on both silica and synthetic polymers for capillary electrochromatography and chip electrochromatography, with a focus on those published during the year 2004. A wide variety of both modified approaches to the "old" monoliths and new monoliths have been reported despite the very short period of time covered. This demonstrates that monolithic stationary phases have become a well-established format in the field of electrochromatography. The simplicity of their preparation as well as the good control over their porous properties and surface chemistries make the monolithic separation media an attractive alternative to capillary columns packed with particulate materials.  相似文献   

3.
Monolithic materials have quickly become a well‐established stationary phase format in the field of capillary electrochromatography (CEC). Both the simplicity of their in situ preparation method and the large variety of readily available chemistries make the monolithic separation media an attractive alternative to capillary columns packed with particulate materials. This review summarizes the contributions of numerous groups working in this rapidly growing area, with a focus on monolithic capillary columns prepared from synthetic polymers. Various approaches employed for the preparation of the monoliths are detailed, and where available, the material properties of the resulting monolithic capillary columns are shown. Their chromatographic performance is demonstrated by numerous separations of different analyte mixtures in variety of modes. Although detailed studies of the effect of polymer properties on the analytical performance of monolithic capillaries remain scarce at this early stage of their development, this review also discusses some important relationships such as the effect of pore size on the separation performance in more detail.  相似文献   

4.
介绍了毛细管电色谱开管柱、填充柱和整体柱的各种制备技术及其优势与不足,特别是对于近期发展的毛细管电色谱整体柱的制备方法及其应用进行了系统综述。引用文献100篇。  相似文献   

5.
Monolithic columns for capillary electrochromatography (CEC) are receiving quite remarkable attention. Both the simplicity of the in situ preparation and the large number of readily available chemistries make the monolithic separation media a vital alternative to capillary columns packed with particulate materials. This review summarizes the current state-of-the-art in this rapidly growing area of CEC with a focus on monolithic capillary columns prepared from synthetic polymers. Recent achievements in column technologies for both high-performance liquid chromatography and capillary electrophoresis are used as the starting point to highlight the influence of these well established analytical methods on the development of monolithic capillary columns for CEC. The effects of individual variables on the separation properties of monolithic capillaries are discussed in detail. The analytical potential of these columns is demonstrated with separations involving various families of compounds in different chromatographic modes.  相似文献   

6.
Monolithic molecularly imprinted columns are a new class of column that emerged in the early 1990s. These monolithic materials are typically prepared directly inside stainless steel columns or capillary columns without the tedious procedures of grinding, sieving, and column packing. Furthermore, the preparation of this type of MIP is more cost-efficient, because the amount of template molecules required is much lower. In recent years monolithic supports as stationary phases in high-performance liquid chromatography (HPLC) and capillary electrochromatography (CEC) have attracted significant interest because of their ease of preparation, high reproducibility, versatile surface chemistry, and rapid mass transport.  相似文献   

7.
Capillary electrochromatography, which combined the high selectivity of high‐performance liquid chromatography and the high separation efficiency of capillary electrophoresis, is an attractive separation tool. In this review, the developments on monolithic and open tubular capillary electrochromatography during 2017 to August 2019 are summarized. Considering the development of novel stationary phases is the most active research field in capillary electrochromatography, monolithic capillary electrochromatography is classified according to the polymer‐based and hybrid monolithic columns, while open‐tubular capillary electrochromatography is categorized by cyclodextrin, silica, polymer, nanomaterials, microporous materials, and biomaterials‐based open tubular columns.  相似文献   

8.
Wu M  Wu R  Zhang Z  Zou H 《Electrophoresis》2011,32(1):105-115
Organic-silica hybrid monolithic columns have drawn more and more attention due to the ease of preparation and good mechanical stability in recent years. Many synthetic approaches have been developed and a variety of hybrid monolithic capillary columns have been prepared. The sol-gel process is well recognized in the fabrication of hybrid monolithic columns, which can be mainly classified as one-step, acid/base two-step procedures. The new approaches such as the "one-pot" and nano-scaled inorganic-organic hybrid reagent of polyhedral oligomeric silsesquioxane used as a cross-linker have also emerged for the preparation of hybrid monolithic columns. The applications of the organic-silica hybrid monolithic capillary columns for capillary electrochromatography, micro high-performance liquid chromatography, solid-phase micro-extraction and enzymatic reactor etc. are included in this review.  相似文献   

9.
Bedair M  El Rassi Z 《Electrophoresis》2004,25(23-24):4110-4119
This review article summarizes the advances made over the last two years in polymeric monoliths for capillary electrochromatography (CEC). It covers the scientific literature in the period extending form the second half of 2002 until the end of first half of 2004. Currently, there is an increasing interest in monolithic stationary phases in CEC as an alternative to particulate packed capillary columns due in major part to the simplicity of the in situ preparation of monolithic stationary phases and the availability of a wide chemistry for surface ligands, which allow for tailoring the chromatographic sorbent needed for solving a given separation problem(s). The various approaches, formats, and chemistries used for the preparation of monolithic stationary phases are described.  相似文献   

10.
Qin F  Xie C  Yu Z  Kong L  Ye M  Zou H 《Journal of separation science》2006,29(10):1332-1343
Monolithic materials have become a well-established format for stationary phases in the field of capillary electrochromatography. Four types of monoliths, namely particle-fixed, silica-based, polymer-based, and molecularly imprinted monoliths, have been utilized as enantiomer-selective stationary phases in CEC. This review summarizes recent developments in the area of monolithic enantiomer-selective stationary phases for CEC. The preparative procedure and the characterization of these columns are highlighted. In addition, the disadvantages and limitations of different monolithic enantiomer-selective stationary phases in CEC are briefly discussed.  相似文献   

11.
溶胶-凝胶法制备毛细管硅胶整体柱的研究进展   总被引:3,自引:0,他引:3  
陈雅顺  贾丽 《分析化学》2008,36(6):853-859
毛细管硅胶整体柱作为一种新型的分离介质,在色谱领域显示出了强大的生命力。本评述介绍了溶胶-凝胶法制备毛细管硅胶整体柱的方法,重点分析了溶胶-凝胶法制备毛细管硅胶整体柱的影响因素,总结了近几年毛细管硅胶整体柱在高效液相色谱和电色谱中的应用。  相似文献   

12.
The focus of this review is on current developments in monolithic stationary phases for the fast analysis of inorganic ions and other small molecules in ion chromatography (IC) and capillary electrochromatography (CEC), concentrating in particular on the properties of organic (polymer) monolithic materials in comparison to inorganic (silica-based) monoliths. The applicability of these materials for fast IC is discussed in the context of recent publications, including the range of synthesis and modification procedures described. While commercial monolithic silica columns already show promising results on current IC instrumentation, polymer-based monolithic stationary phases are currently predominantly used in the capillary format on modified micro-IC systems. However, they are beginning to find application in IC particularly under high pH conditions, with the potential to replace their particle-packed counterparts.  相似文献   

13.
Jin W  Fu H  Huang X  Xiao H  Zou H 《Electrophoresis》2003,24(18):3172-3180
Preparation of a poly(styrene-co-divinylbenzene-co-methacrylic acid) monolithic stationary phase for the use in capillary electrochromatography (CEC) has been improved by optimizing the polymerization conditions. It is observed that the reaction time strongly affects column efficiency, while the proportion of isooctane in porogen influences peak symmetry of some solutes seriously. The lifetime of the monolithic columns prepared mainly depends on the pH of buffers used. Reproducibility of electroosmotic flow (EOF) from batch to batch columns are lower than 2.8% relative standard deviation. Unlike other types of capillary electrochromatographic monoliths, a pH-dependent EOF was observed on this type of column. Separation of various types of compounds including aromatic hydrocarbons, hormones, anilines, basic pharmaceuticals, and peptides was achieved. The facile preparation and wide application of this monolithic column may make styrene-based polymer a potential stationary phase in CEC.  相似文献   

14.
采用溶胶-凝胶法,以四乙氧基硅烷和苯基三乙氧基硅烷作为反应单体,通过酸碱两步催化在毛细管中进行原位缩聚反应,制备了新型有机-无机杂化硅胶基质毛细管整体柱,制备过程简单。整体柱基质中均匀分布的苯基基团可直接用于反相毛细管电色谱的分离,因而不需要对基质再进行衍生化。优化了整体柱的制备条件,采用扫描电镜和压汞法对整体柱的微观结构和孔径分布进行了表征。分别考察了溶胶-凝胶初始反应液中水的用量对柱床结构的影响和两种单体的配比对材料孔径分布的影响。研究了稠环芳烃类化合物在整体柱上的保留行为,用所制备的整体柱分离了7种苯酚类化合物,平均柱效达100000塔板/m。  相似文献   

15.
This work reports the preparation of monolithic zirconia chiral columns for separation of enantiomeric compounds by capillary electrochromatography (CEC). Using sol–gel technology, a porous monolith having interconnected globular-like structure with through-pores is synthesized in the capillary column as a first step in the synthesis of monolithic zirconia chiral capillary columns. In the second step, the surface of the monolith is modified by coating with cellulose tris(3,5-dimethylphenylcarbamate) (CDMPC) as the chiral stationary phase to obtain a chiral column (CDMPCZM). The process of the preparation of the zirconia monolithic capillary column was investigated by varying the concentrations of the components of the sol solution including polyethylene glycol, water and acetic acid. CDMPCZM is mechanically stable and no bubble formation was detected with the applied current of up to 30 μA. The enantioseparation behavior of the CDMPCZM columns was investigated by separating a set of 10 representative chiral compounds by varying the applied voltage and pH and organic composition of the aqueous organic mobile phases.  相似文献   

16.
Microwave irradiation can provide a viable alternative to the traditional means such as ultraviolet light and thermal initiation for the preparation of monolithic capillary columns. Polystyrene-based monolithic stationary phases were prepared in situ in fused-silica capillaries and simultaneously in vials. The column permeability, electrophoretic and chromatographic behavior were evaluated using pressure-assisted capillary electrochromatography (pCEC), capillary electrochromatography (CEC) and low pressure liquid chromatography (LPLC). With an optimal monolithic material, the largest theoretical plates for preparing the column could be close to 18,000 plates/m for thiourea in the mode of pCEC. Furthermore, the influence of the composition of the porogenic solvents (toluene/isooctane) on the morphology of organic-based monoliths [poly(styrene-divinylbenzene-methacrylic acid)] was systematically studied with mercury intrusion porosimetry and scanning electron microscopy. The monoliths which were prepared with a high content of isooctane had a bigger pore size and better permeability, and hence resulted in a faster separation.  相似文献   

17.
采用溶胶-凝胶技术制备了丁基胺丙基硅胶毛细管整体柱,此整体固定相表面同时含有能产生阳极的电渗流的仲胺官能团和产生疏水作用的正丁基和丙基官能团。对所制备的整体柱电色谱性能进行了详细的表征和分析。考察了流动相pH值对电渗流的影响;对烷基苯同系物、有机酸酸性化合物和苯胺类碱性化合物保留行为进行了研究,并对其可能的保留机理进行了探讨。实验结果表明,对于中性化合物的保留机理主要基于反相作用;而对于酸性化合物的保留行为则是基于混合模式作用机理,即除了电泳作用外,还包括阴离子交换和疏水作用。碱性化合物在丁基胺丙基硅胶毛细管整体柱上的峰形较好,没有明显的峰拖尾现象。  相似文献   

18.
In recent years, continuous separation media have attracted considerable attention because of the advantages they offer over packed columns. This research resulted in two useful monolithic material types, the first based on modified silica gel and the second on organic polymers. This work attempts to review advances in the development, characterization, and applications of monolithic columns based on synthetic polymers in capillary chromatography, with the main focus on monolithic beds prepared from methacrylate-ester based monomers. The polymerization conditions used in the production of polymethacrylate monolithic capillary columns are surveyed, with attention being paid to the concentrations of monomers, porogen solvents, and polymerization initiators as the system variables used to control the porous and hydrodynamic properties of the monolithic media. The simplicity of their preparation as well as the possibilities of controlling of their porous properties and surface chemistries are the main benefits of the polymer monolithic capillary columns in comparison to capillary columns packed with particulate materials. The application areas considered in this review concern mainly separations in reversed-phase chromatography, ion-exchange chromatography, hydrophobic and hydrophilic interaction modes; enzyme immobilization and sample preparation in the capillary chromatography format are also addressed.  相似文献   

19.
An adamantyl (ADM)-functionalized monolithic stationary phase was newly synthesized by a single-step copolymerization of 1-adamantyl-(α-trifluoromethyl) acrylate, ethylene dimethacrylate, and 2-acrylamido-2-methyl-1-propanesulfonic acid in order to prevent the peak tailing of basic solutes in capillary electrochromatography and was compared with butyl methacrylate (BMA)-based one. The ADM structure shields the negatively charged groups on the surface of monolith from basic solutes, resulting in better peak shapes than BMA-based monolithic stationary phase. As the monomers ratio decreased, the monolithic column had lower retention and higher column efficiency which was likely due to lower phase ratio and smaller globule size of monolith, respectively. The ADM-functionalized monolithic columns exhibited a good repeatability and reproducibility of column preparation with relative standard deviation values below 9% in the studied chromatographic parameters.  相似文献   

20.
Modern rigid porous polymer monoliths were conceived as a new class of stationary phases in classical columns in the early 1990s and later extended to the capillary format. These monolithic materials are typically prepared using a simple molding process carried out within the confines of the capillary. Polymerization of a mixture comprising monomers, initiator, and porogenic solvent affords macroporous materials with large through-pores that enable applications in a rapid flow-through mode. Since all the mobile phase must flow through the monolith, convection considerably accelerates mass transport within the monolithic separation medium and improves the separations. As a result, monolithic columns perform well even at very high flow rates. Various mechanisms including thermally and UV initiated free radical polymerization as well as ring opening metathesis copolymerizations were demonstrated for the preparation of monolithic capillary columns. The versatility of these preparation techniques was demonstrated by their use with hydrophobic (styrene, divinylbenzene, butyl methacrylate, ethylene dimethacrylate), hydrophilic (2-hydroxyethyl methacrylate, methacrylamide, methylenebisacrylamide), ionizable (vinylsulfonic acid, 2-acrylamido-2-methyl-propanesulfonic acid), and tailor-made (norborn-2-ene, 1,4,4a,5,8,8a-hexahydro-1,4,5,8-exo,endo-dimethanonaphthalene) monomers. Variation of polymerization conditions enables control of the porous properties of the monolith over a broad range and mediates the hydrodynamic properties of the monolithic columns. The applications of polymer-based monolithic capillary columns are demonstrated for numerous separations in the microHPLC mode.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号