首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 171 毫秒
1.
Simultaneous multicomponent analysis is usually carried out using multivariate calibration models, such as the partial least squares (PLS) one, that utilize the full spectrum. It has been shown by both experimental and theoretical considerations that better results can by obtained by proper selection of the spectral range to be included in calculations. A genetic algorithm (GA) is one of the most popular methods for selecting variables for PLS calibration of mixtures with almost identical spectra without loss of predictive capability. In this work, a simple and precise method for rapid and accurate simultaneous determination of sulfide and sulfite ions based on the addition reaction of these ions with new fuchsin at pH 8 and 25°C using PLS regression and GA for variable selection is proposed. The concentrations of sulfide ions varied between 0.05–2.50 and 0.15–2.00 μg/mL, respectively. A series of model solutions containing different concentrations of sulfide and sulfite were used to check the predictive ability of GA-PLS models. The root mean square error of prediction with PLS on the whole data set was 0.19 μg/mL for sulfide and 0.09 μg/mL for sulfite. After the application of GA, these values reduced to 0.04 and 0.03 μg/mL, respectively. The text was submitted by the authors in English.  相似文献   

2.
Simultaneous multicomponent analysis is usually carried out by multivariate calibration models such as partial least squares (PLS) that utilize the full spectrum. It has been demonstrated by both experimental and theoretical considerations that better results can be obtained by a proper selection of the spectral range to be included in calculations. A genetic algorithm is one of the most popular methods for selecting variables for PLS calibration of mixtures with almost identical spectra without loss of prediction capacity. In this work, a simple and precise method for rapid and accurate simultaneous determination of sulfide and sulfite ions based on the addition reaction of these ions with new fuchsin at pH 8 and 25°C by PLS regression and using a genetic algorithm (GA) for variable selection is proposed. The concentrations of sulfide and sulfite ions varied between 0.05–2.50 and 0.15–2.00 μg/mL, respectively. A series of synthetic solutions containing different concentrations of sulfide and sulfite were used to check the prediction ability of GA-PLS models. The root mean square error of prediction with PLS on the whole data set was 0.19 μg/mL for sulfide and 0.09 μg/mL for sulfite. After the application of GA, these values were reduced to 0.04 and 0.03 μg/mL, respectively. The text was submitted by the authors in English.  相似文献   

3.
This study investigates a new approach for the amperometric determination of sulfide using a hematoxylin multiwalled carbon nanotubes modified carbon paste electrode (HM‐MWCNTs/CPE). The experimental results show that HM‐MWCNTs/CPE significantly enhances the electrocatalytic activity towards sulfide oxidation. Cyclic voltammetric studies show that the peak potential of sulfide shifted from +400 mV at unmodified CPE to +175 mV at HM‐MWCNTs/CPE. The currents obtained from amperometric measurements at optimum conditions were linearly correlated with the concentration of sulfide. The calibration curve was obtained for sulfide concentrations in the range of 0.5–150×10?6 mol L?1. The detection limit was found to be 0.2×10?6 mol L?1 for the amperometric method. The proposed method was successfully applied to a river water sample in Pardubice, Czech Republic.  相似文献   

4.
The univariate and multivariate calibration methods were applied for the simultaneous determination of iodate and periodate in water. The method is based on the reaction of periodate and iodate with pyrogallol red in sulfuric acid media. The reaction was monitored spectrophotometrically by measuring the decrease in absorbance of pyrogallol red at 470 nm. The calibration curve was linear over the concentration ranges of 0.1-12 and 0.1-14 μg ml−1 for iodate and periodate, respectively. The experimental calibration matrix for partial least squares (PLS) and orthogonal signal correction (OSC-PLS) method was designed with 35 mixtures. The results obtained by the PLS and OSC-PLS were statistically compared. The effects of various cations and anions on iodate and periodate determination have been investigated.  相似文献   

5.
A photometric method has been developed for the determination of sulfide at 10(-5) mol dm(-3) levels, which is based on the reaction of sulfide with a given excess amount of bismuth(III) to form a precipitate of bismuth(III) sulfide and on the spectrophotometric measurement of the residual bismuth(III) at 335 nm after extracting with bismuthiol II reagent from an aqueous solution containing acetate buffer into benzene. The presence of sulfite and thiosulfate up to 0.002 mol dm(-3) did not cause any interference in the determination of sulfide, because both sulfite and thiosulfate do not produce any precipitate with bismuth(III). A linear calibration plot with a negative slope was obtained for sulfide over the range of 5.00 x 10(-7) - 3.00 x 10(-5) mol dm(-3) (16.0 - 960 ppb). An experimental calibration plot was in accord with the theoretical plot, taking into account the known excess of bismuth(III), showing that the reaction of sulfide with bismuth(III) proceeded to completion. The relative standard deviation of results from 10 replicate determinations of standard sulfide (2.00 x 10(-5) mol dm(-3)) was 0.44%. The proposed method was successfully applied to the determination of sulfide in hotspring water samples without any pretreatment.  相似文献   

6.
We report here a highly stable and sensitive chemically modified screen-printed carbon electrode (CMSPE) for sulfide analysis. The CMSPE was prepared by first ion-exchanging ferricyanide into a Tosflex anion-exchange polymer and then sealing with a tetraethyl orthosilicate sol-gel layer. The sol-gel overlayer coating was crucial to stabilize the electron mediator (i.e., Fe(CN)63−) from leaching. The strong interaction between the oxy-hydroxy functional group of sol-gel and the hydrophilic sites of Tosflex makes the composite highly rigid to trap the ferricyanide mediator. An obvious electrocatalytic sulfide oxidation current signal at ∼0.20 V versus Ag/AgCl in pH 7 phosphate buffer solution was observed at the CMSPE. A linear calibration plot over a wide range of 0.1 μM to 1 mM with a slope of 5.6 nA/μM was obtained by flow injection analysis. The detection limit (S/N = 3) was 8.9 nM (i.e., 25.6 ppt). Practical utility of the system was applied to the determination of sulfide trapped from cigarette smoke and sulfide content in hot spring water.  相似文献   

7.
A new fluorometric method for the determination of lithium based on the formation of a fluorescent species with 1,4-dihydroxyanthraquinone (Quinizarine), in acetone-water (90-10%) medium and 10−3M in NaOH is described. The fluorescent species has two excitation maxima at 560 and 596 nm and one emission maxima at 620 nm. It is stable at least 7 hr and the calibration graph is linear over the range 50–700 ppb Li. The method has a relative error over the average of measurements of 1.62%.  相似文献   

8.
《Analytical letters》2012,45(9):1643-1655
Abstract

A Kinetic spectrophotometric method for the determination of ultra-trace amounts of lead(II) is described. This method is based on the catalytic action of this ion on the reduction of resazurin by sulfide. The course of the chemical reaction is followed spectrophotometrically by the measurement of reduction in absorbance of resazurin at 605 nm. The calibration range of Pb(II) is dependent on the sulfide concentration.

With this method 1 ng m1?1 lead can be detected. The method is used for determination of Pb(II) in KNO3 (Fluka) and in water.  相似文献   

9.
The univariate and multivariate calibration methods were applied for the determination of trace amounts of palladium based on the catalytic effect on the reaction between resazurine and sulfide. The decrease in absorbance of resazurine at 602 nm over a fixed time is proportional to the concentration of palladium over the range of 10.0-160.0 ng mL(-1). The calibration matrix for partial least squares (PLS) regression was designed with 14 samples. Orthogonal signal correction (OSC) is a preprocessing technique used for removing the information unrelated to the target variables based on constrained principal component analysis. OSC is a suitable preprocessing method for PLS calibration without loss of prediction ability using spectrophotometric method. The root mean square error of prediction (RMSEP) for palladium determination with fixed-time, PLS and OSC-PLS were 3.71, 2.84 and 0.68, respectively. This procedure allows the determination of palladium in synthetic and real samples with good reliability of the determination.  相似文献   

10.
In this work, we demonstrate the feasibility of applying headspace single-drop microextraction with in-drop precipitation for the quantitative determination of the acid labile sulfide fraction (H2S, HS, and S2− (free sulfide), amorphous FeS and some metal sulfide complexes-clusters as ZnS) in aqueous samples by microvolume turbidimetry. The methodology lies in the in situ hydrogen sulfide generation and subsequent sequestration into an alkaline microdrop containing ZnO22− and exposed to the headspace above the stirred aqueous sample. The ZnS formed in the drop was then determined by microvolume turbidimetry. The optimum experimental conditions of the proposed method were: 2 μL of a microdrop containing 750 mg L−1 Zn(II) in 1 mol L−1 NaOH exposed to the headspace of a 20-mL aqueous sample stirred at 1600 rpm during 80 s after derivatization with 1 mL of 6 mol L−1 HCl. An enrichment factor of 1710 was achieved in only 80 s. The calibration graph was linear in the range of 5-100 μg L−1 with a detection limit of 0.5 μg L−1. The repeatability, expressed as relative standard deviation, was 5.8% (N = 9). Finally, the proposed methodology was successfully applied to the determination of the acid labile sulfide fraction in different natural water samples.  相似文献   

11.
Two new, simple and accurate methods for the determination of sulfide (S2−) at low levels (μg L−1) in aqueous samples were developed. The generation of hydrogen sulfide (H2S) took place in a coil where sulfide reacted with hydrochloric acid. The resulting H2S was then introduced as a vapor into an inductively coupled plasma-atomic emission spectrometer (ICP-AES) and sulfur emission intensity was measured at 180.669 nm. In comparison to when aqueous sulfide was introduced, the introduction of sulfur as H2S enhanced the sulfur signal emission. By setting a gas separator at the end of the reaction coil, reduced sulfur species in the form of H2S were removed from the water matrix, thus, interferences could be avoided. Alternatively, the gas separator was replaced by a nebulizer/spray chamber combination to introduce the sample matrix and reagents into the plasma. This methodology allowed the determination of both sulfide and sulfate in aqueous samples. For both methods the linear response was found to range from 5 μg L−1 to 25 mg L−1 of sulfide. Detection limits of 5 μg L−1 and 6 μg L−1 were obtained with and without the gas separator, respectively. These new methods were evaluated by comparison to the standard potentiometric method and were successfully applied to the analysis of reduced sulfur species in environmental waters.  相似文献   

12.
The partial least squares (PLS-1) calibration model based on spectrophotometric measurement, for the simultaneous determination of CN and SCN ions is described. The method is based on the difference in the rate of the reaction between CN and SCN ions with chloramine-T in a pH 4.0 buffer solution and at 30 °C. The produced cyanogen chloride (CNCl) reacts with pyridine and the product condenses with barbituric acid and forms a final colored product. The absorption kinetic profiles of the solutions were monitored by measuring absorbance at 578 nm in the time range 20-180 s after initiation of the reaction with 2 s intervals. The experimental calibration matrix for partial least squares (PLS-1) calibration was designed with 31 samples. The cross-validation method was used for selecting the number of factors. The results showed that simultaneous determination could be performed in the range 10.0-900.0 and 50.0-1200.0 ng mL−1 for CN and SCN ions, respectively. The proposed method was successfully applied to the simultaneous determination of cyanide and thiocyanate in water samples.  相似文献   

13.
A sensitive kinetic spectrophotometric method for the determination of ng amounts of sulfide has been developed based on the reduction of Azure A by sulfide in the presence of Brij-35 at pH 7. The decrease in absorbance of Azure A at 600 nm is proportional to the concentration of sulfide over the range 25–1400 ng mL–1. The variables affecting the rate of the reaction were investigated and the optimum conditions were established. The method is simple, rapid, precise, sensitive, and widely applicable. The limit of detection is 17 ng mL–1, and the relative standard deviation of seven determinations of 500 ng mL–1 sulfide was 2.1%. The method was applied to the determination of sulfide in spring water.  相似文献   

14.
In the present work a systematic comparison among spectrophotometric flow injection methods for sulfide determination based on phenothiazine dye production from diverse aromatic p-substituted amines were performed. The behavior of N,N-dimethylphenyl-p-diamine (DMPD), N,N-diethylphenyl-p-diamine (DEPD), phenyl-p-diamine (PPD), p-aminophenol (PAP) and other three aromatic amines was investigated and the chemical parameters of proposed flow methods were optimized by applying central composite design. For each evaluated method the concentration of amine, Fe3+ and H2SO4 was optimized and after the evaluation of reagents addition order the flow parameters were independently ascertained. Analytical signal was strongly diminished in the presence of iodide for flow methods based on the reaction of sulfide with DMPD, PPD or DEPD while fluoride was considered as an important interference for methods based on the reaction with PPD or PAP. The evaluated aromatic amines have permitted sulfide determination in a wide concentration range from 0.05 to 3.0 mg L− 1 and limits of detection (3σ) varying from 18.8 to 51.0 μg L− 1, for DEPD and PPD, respectively. The sensitivity of flow methods based on PPD and DMPD was higher even as PAP has permitted sulfide determination in a large sulfide concentration range. In addition, higher throughput was attained for DMPD method. The proposed methods were applied for sulfide determination in industrial wastewater and the obtained results were in agreement with reference method at 95% confidence level.  相似文献   

15.
Abbaspour A  Najafi M 《Talanta》2003,60(5):1079-1084
A method for simultaneous spectrophotometric determination of Sb(III) and Sb(V) using multivariate calibration method is proposed. This method is based on the development of the reaction between the analytes and pyrogallol red at pH 2.00. The selection of variables was studied. A series of synthetic solutions containing different concentrations of Sb(III) and Sb(V) were used to check the prediction ability of the partial least squares model. The calibration curves were linear over the range of 0.3-3.4 and 0.3-3.0 μg ml−1 for Sb(III) and Sb(V), respectively. The detection limits were 0.177 and 0.200 μg ml−1 for Sb(III) and Sb(V), respectively.  相似文献   

16.
A highly sensitive fluorescence quenching method has been developed for selective determination of hydrogen peroxide based on the catalytic effect of hemin on theo-hydroxyphenylfluorone (a new fluorogenic substrate) and hydrogen peroxide system. Under optimum conditions, the calibration graph was linear over the range 0–1.0 × 10−6mol/liter hydrogen peroxide, with a limit of detection of 8.0 × 10−9mol/liter in a 10-min reaction period. It can easily be incorporated into the determination of biochemical substances that produce hydrogen peroxide under catalytic oxidation by their oxidase. This possibility has been tested for the determination of glucose in human sera as an example.  相似文献   

17.
A simple, sensitive and selective method for the determination of bromide in seawater by using a flow injection/stopped-flow detection technique was examined. The detection system was developed for a new kinetic-spectrophotometric determination of bromide in the presence of chloride matrix without any extraction and/or separation. The detection was based on the kinetic effect of bromide on the oxidation of methylene blue (MB) with hydrogen peroxide in a strongly acidic solution. Large amounts of chloride could enhance the sensitivity of the method as an activator. The decolorisation of the blue color of MB was used for the spectrophotometric determination of bromide at 746 nm. A stopped-flow approach was used to improve the sensitivity of the measurement and provide good linearity of the calibration over the range of 0-3.2 μg ml−1 of bromide. The relative standard deviation was 0.74% for the determination of 2.4 μg ml−1 bromide (n = 5). The detection limit (3σ) was 0.1 μg ml−1 with a sampling frequency of 12 h−1. The influence of potential interfering ions was studied. The proposed method was applied to the determination of bromide in seawater samples and provided satisfactory results.  相似文献   

18.
A simple, rapid, and sensitive method has been developed for the determination of trace amounts of sulfide based on its reaction with thionine. The reaction is monitored spectrophotometrically by measuring the decreasing absorbance of the dyestuff at 600 nm by the fixed time method. After optimization of the measuring conditions the calibration curves were found linear up to 38.0 ppm (four regions), and the theoretical limit of detection was 0.076 ppm and the relative standard deviation for determination of 1.0 ppm sulfide (n = 10) was found to be 2.7%. The proposed method was applied successfully to the determination of sulfide in spring water and wastewater samples.  相似文献   

19.
The inclusion complex of sulphaguanidine (SGN) in β-cyclodextrin has been investigated. To avoid the problem of the low solubility of β-cyclodextrin in water, solutions of β-cyclodextrin in urea have been used. A 1:1 stoichiometry and an association constant of 450 M−1 have been established for the complex. A new spectrofluorimetric method has been developed for the determination of SGN residues in honey samples. This sulphonamide is widely employed for honey treatment. The method for the determination is based on second-order multivariate calibration, applying parallel factor analysis (PARAFAC). No previous separation or samples pre-treatment were required. The calibration solutions were prepared in water, with concentrations in the range from 0.02 to 0.20 μg mL−1 for SGN. The use of the second-order calibration method in the standard addition mode, using the excitation-emission matrices (EEMs) as analytical signal, allowed its determination in honey samples, even in the presence of interferences, with satisfactory results. The proposed procedure was validated by comparing the obtained results with a HPLC method, with satisfactory results for the assayed method.  相似文献   

20.
A new selective, sensitive, and rapid response microelectrode for microamount chromium(III) determination was developed. For the electrode preparation, fuchsin basic was electropolymerized onto a carbon microdisk electrode, and then diethylenetriamminepentaacetic acid (DTPA) was self‐assembled on the electrode surface by the reaction between DTPA and poly(fuchsin basic). The determination conditions were optimized. The electrode showed a linear response to Cr3+ ions in the concentration range of 1.0×10?6?1.0×10?4 M and exhibits a super‐Nernstian slope of 32.5±0.4 mV per decade. The detection limit is 3.6×10?7 M. The response time of the electrode is less than 10 s, and it can be used for at least 2 months with limited considerable divergences in its potentials. The proposed electrode was applied for monitoring the chromium ion level in wastewater of chromate industries.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号