首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The retention behaviour of four membrane-associated peptides and proteins with an immobilized phosphatidic acid (PA) stationary phase was evaluated. The solutes included the cytolytic peptides gramicidin A and melittin, the integral membrane protein bacteriorhodpsin and cytochrome c, a peripheral membrane protein. Gramicidin has no nett charge and exhibited normal reversed phase-like behaviour which was largely independent of mobile phase pH. In contrast, melittin, which has a positively charged C-terminal tail, exhibited reversed phase like retention at pH 5.4 and 7.4, and was not retained at pH 3 reflecting the influence of electrostatic interactions with the negatively charged phosphatidic acid ligand. Bacteriorhodpsin was eluted at high acetonitrile concentrations at pH 3 and 5.4 and cytochrome c was only eluted at pH 3. Moreover, cytochrome c eluted in the breakthrough peak between 0 and 100% acetonitrile, demonstrating the role of electrostatic interactions with the PA surface. Overall, the results demonstrate that pH can be used to optimize the fractionation and separation of membrane proteins with immobilized lipid stationary phases.  相似文献   

2.
A new stationary phase which contains both negatively charged phosphate groups and positively charged amino groups was successfully synthesized by modification of amino-functionalized silica particles with trichlorophosphine oxide (POCl3) for hydrophilic interaction chromatography (HILIC). The composition of the surface grafts was determined by Fourier transform infrared spectroscopy and elemental analysis. Various parameters, such as column temperature, water content, pH values and ionic strength of the mobile phase were investigated to study the retention mechanism. The results demonstrated that the stationary phase involved a complex retention process including surface adsorption, partitioning and electrostatic interactions. Under optimized conditions, the separation of nucleobases and nucleosides, water-soluble vitamins, organic acids on the novel stationary phase could be achieved in the HILIC mode.  相似文献   

3.
Cheng  Xiao-Dong  Peng  Xi-Tian  Yu  Qiong-Wei  Yuan  Bi-Feng  Feng  Yu-Qi 《Chromatographia》2013,76(23):1569-1576

A new stationary phase which contains both negatively charged phosphate groups and positively charged amino groups was successfully synthesized by modification of amino-functionalized silica particles with trichlorophosphine oxide (POCl3) for hydrophilic interaction chromatography (HILIC). The composition of the surface grafts was determined by Fourier transform infrared spectroscopy and elemental analysis. Various parameters, such as column temperature, water content, pH values and ionic strength of the mobile phase were investigated to study the retention mechanism. The results demonstrated that the stationary phase involved a complex retention process including surface adsorption, partitioning and electrostatic interactions. Under optimized conditions, the separation of nucleobases and nucleosides, water-soluble vitamins, organic acids on the novel stationary phase could be achieved in the HILIC mode.

  相似文献   

4.
Fu H  Jin W  Xiao H  Huang H  Zou H 《Electrophoresis》2003,24(12-13):2084-2091
Separation of small peptides by hydrophilic interaction capillary electrochromatography (HI-CEC) has been investigated. The negative surface charge of a hydrophilic, strong-cation-exchange stationary phase (PolySULFOETHYL A) provided a substantial cathodic electroosmotic flow (EOF). The influence of acetonitrile content, ionic strength, mobile phase pH as well as applied voltage on the migration of the peptides was studied. Possible retention mechanisms of the peptides in HI-CEC were discussed. It was found that hydrophilic interaction between the solutes and the stationary phase played a major role in this system, especially when mobile phases with high acetonitrile content were used. However, an ion-exchange mechanism and electrophoretic mobility also affect the migration of the peptides in HI-CEC. Elution order and selectivity was proved to be different in HI-CEC and capillary zone electrophoresis (CZE), thus revealing the potential of HI-CEC as a complementary technique to CZE for the separation of peptides. Efficiency and selectivity of HI-CEC for the separation of peptides were demonstrated by baseline separating nine peptides in 6 min.  相似文献   

5.
The separation of several insect oostatic peptides (IOPs) was achieved by using CEC with a strong-cation-exchange (SCX) stationary phase in the fused-silica capillary column of 75 microm id. The effect of organic modifier, ionic strength, buffer pH, applied voltage, and temperature on peptides' resolution was evaluated. Baseline separation of the studied IOPs was achieved using a mobile phase containing 100 mM pH 2.3 sodium phosphate buffer/water/ACN (10:20:70 v/v/v). In order to reduce the analysis time, experiments were performed in the short side mode where the stationary phase was packed for 7 cm only. The selection of the experimental parameters strongly influenced the retention time, resolution, and retention factor. An acidic pH was selected in order to positively charge the analyzed peptides, the pI's of which are about 3 in water buffer solutions. A good selectivity and resolution was achieved at pH <2.8; at higher pH the three parameters decreased due to reduced or even zero charge of peptides. The increase in the ionic strength of the buffer present in the mobile phase caused a decrease in retention factor for all the studied compounds due to the decreased interaction between analytes and stationary phase. Raising the ACN concentration in the mobile phase in the range 40-80% v/v caused an increase in both retention factor, retention time, and resolution due to the hydrophilic interactions of IOPs with free silanols and sulfonic groups of the stationary phase.  相似文献   

6.
Capillary-channeled polymer (C-CP) fibers extruded from nylon-6 are used as the stationary phase for the ion-exchange/reversed-phase mixed-mode chromatographic separation of a three protein mixture. The nylon-6 C-CP fibers are packed collinearly in a 250 x 1.5-mm i.d. column with an interstitial fraction of approximately 0.6. The effects of four displacing salts at three different pHs are studied with regards to protein retention time, peak width, selectivity, and resolution for a synthetic mixture consisting of myoglobin, ribonuclease A, and lysozyme to determine the optimum mobile phase conditions. The net charge model is found to be inadequate in fully explaining the retention behavior, as the proteins are retained by anion and cation-exchange interactions, as well as hydrophobic interactions with the stationary phase. It is found that pH and displacing salt strength had a significant influence on the retention properties and resolution of the proteins.  相似文献   

7.
8.
《Analytical letters》2012,45(14):2761-2774
ABSTRACT

The high-performance liquid chromatographic behavior of some bases and nucleosides was studied on a new reversed-phase stationary phase, alkylphosphonate-modified magnesia-zirconia. The effect of mobile phase variable such as methanol content, ionic strength and pH on their behavior was investigated. It was found that the retention behavior of the bases and nucleosides on the new stationary phase is similar to that on ODS stationary phase. The retention mechanism on the new stationary phase was also discussed. The separation of some bases and nucleosides was accomplished on the new stationary phase.  相似文献   

9.
Summary Several mobile phase parameters were investigated for controlling enantioselective retention and resolution on a chiral stationary phase made in-house. The chiral selector was the enzyme amyloglucosidase, which was immobilized onto a silica support via reductive amination. The influences of the mobile phase pH, concentration and type of uncharged organic modifier, ionic strength and column temperature on enantios-electivity were studied. The analysis time for resolving enantiomers could be adjusted with only a minor decrease in enantioselectivity by using a high ionic strength mobile phase buffer. This indicated a retention mechanism involving ion-exchange interactions. It was further confirmed by the decreasing enantioselectivity of amines when using a mobile phase pH below the isoelectric point of the native protein. Interesting effects were observed when the organic modifier concentration was increased and also when the column temperature was raised. Both retention and enantioselectivity increased with increasing concentration of 2-propanol in the mobile phase. Examples are given where both enantioselectivity and retention increased with increasing column temperature. Thermodynamic studies were performed to calculate the entropy and enthalpy constants. The results showed that, depending on mobile phase composition, the enantioselective retention may be caused by differences in entropy or enthalpy.  相似文献   

10.
王晓欢  陈磊 《色谱》2018,36(9):850-857
混合模式色谱(MMC)在复杂样品的分离分析方面具有独到的优势,相比于单一模式色谱,MMC受到多种作用控制,保留机理更为复杂。利用巯基-烯点击化学方法分别制备了单配体和双配体两种硫醚嵌入苯磺酸硅胶固定相,通过改变pH、离子强度和有机溶剂强度等流动相条件,以4种碱性药物为模型,对其保留机理进行了探讨。结果表明,两种固定相都具有反相和离子交换的混合保留机理。通过改变流动相中盐浓度、考察溶质保留因子与盐浓度倒数的关系,证明了反相、单纯离子交换和反相协同离子交换三种作用形式的保留模型更为合理。定量研究表明,在两个固定相上,由单纯离子交换和反相协同离子交换构成的总离子交换作用占主导,各作用占比与溶质、流动相组成、固定相配体的类型及其比例等密切相关,并且协同作用对溶质的保留和分离选择性影响很大。混合模式色谱保留机理的研究对于新型固定相设计和复杂体系的分离优化具有重要理论指导意义。  相似文献   

11.
A novel phosphorylcholine type zwitterionic stationary phase was synthesized by graft polymerization of 2-methacryloyloxyethyl phosphorylcholine onto the surface of porous silica particles. The resulting material possesses both negatively charged phosphoric acid and positively charged quaternary ammonium groups, which renders it a low net charge over a wide pH range. The composition of the surface grafts were determined by elemental analysis and solid state NMR, and the surface charge (zeta-potential) in different buffer solutions were measured using photon correlation spectroscopy. Separation of several peptides was investigated on packed columns in the hydrophilic interaction liquid chromatography (HILIC) separation mode. It was shown that small peptides can be separated based on hydrophilic interaction and ionic interaction between the stationary phase and analyte. The organic solvent composition, the pH and the salt concentration of the eluent have strong effects on the retention time. Compared to native silica before grafting, the newly synthesized zwitterionic material gave more stable retention times for basic peptides over pH range 3-7 due to elimination of the dissociation of silanol groups.  相似文献   

12.
The effect of mobile-phase constituents (pH and ionic strength) and chromatographic behaviour of ten aminoglycosides (streptomycin, dihydrostreptomycin, spectinomycin, apramycin, paramomycin, kanamycin A, gentamycin C1, gentamycin C2/C2a, gentamycin C1a and neomycin) in the bare silica, amino, amide and zwitterionic phases of hydrophilic interaction chromatography (HILIC) were studied systematically. Among the stationary phases studied, the zwitterionic phase provided the best separation of aminoglycosides. The effect of pH, ionic concentration and column temperature on retention time, peak shape and sensitivity was studied using a central composite design. pH affected sensitivity of the detection of analytes but not the retention time. High ionic strength in the mobile phase was necessary to control the ionic interactions between ionised aminoglycosides and the hydrophilic phase, thereby influencing peak shape and retention time. Column temperature affected sensitivity of the detection but not the retention time. During method development, crosstalk between the MS/MS channels of the analytes was observed and resolved.  相似文献   

13.
研究了一些芳胺类化合物在1-萘甲膦酸改性氧化锆固定相上的色谱行为。分别考察了流动相中甲醇含量、缓冲液pH值和离子强度等对芳胺类化合物色谱保留的影响,并对这类化合物在该固定相上的保留机理进行了探讨。研究结果表明,芳胺类化合物在该固定相上表现出反相和阳离子交换的混合保留模式。以pH 10.1的Tris-甲醇(60/40,V/V)溶液为流动相,在1-萘甲膦酸改性氧化锆固定相上成功分离了间苯二胺、邻甲苯胺、N-甲苯胺、对硝基苯胺、邻硝基苯胺和α-甲萘胺6种芳胺类化合物。  相似文献   

14.
The high-performance liquid chromatographic behavior of some basic drugs was studied on a n-octadecylphosphonic acid modified magnesia-zirconia (C18PZM) stationary phase. The effect of mobile phase variables such as methanol content, ionic strength, and pH on their chromatographic behavior was investigated. The retention mechanism of basic drugs on the stationary phase was elucidated. The results indicate that both hydrophobic and cation-exchange interactions contribute to solute retention under most chromatographic conditions. The inherent Br?nsted-acid sites and also the adsorbed Lewis base anionic buffer constituents on accessible ZM surface Lewis acid sites play a role in the retention of ionized solutes by cation-exchange interaction. However, especially at high mobile phase pH, the retention of basic drugs depends mainly on hydrophobic interactions between solutes and support. Separations of the basic drugs on the C18PZM phase by a predominantly reversed-phase retention mode were very promising. The mixed-mode retention feature on this phase, as a result of the adsorbed Lewis base anionic buffer constituents acting as sites for cation-exchange, could also be very useful, e.g. for enhancing the chromatographic selectivity of such analytes. The C18PZM seems to be an excellent alternative to silica-based reversed-phase stationary phase for the separation of strongly basic solutes.  相似文献   

15.
A number of different stationary phases designed for hydrophobic interaction chromatography have been examined to assess their efficiency and resolving capability with respect to protein and peptide mixtures. A packing with an ether-bonded phase was substantially less hydrophobic than those with propyl- or phenyl-bonded surface chemistry. While the overall efficiencies of most columns were broadly similar with respect to most proteins, some proteins did chromatograph with enhanced efficiency on specific packings. The elution order of individual proteins was, with one or two exceptions, similar for all columns tested using comparable mobile phases. It differed, however, substantially from orders obtained with conventional reversed-phase alkyl-bonded phases and from the elution orders obtained when the hydrophobic packings were used in a reversed-phase mode, i.e. with an organic modifier gradient. Varying the salt used in the mobile phase and its pH under hydrophobic interaction conditions (high ionic strength) changed overall retentivities and also altered specific retention orders, thus offering possibilities of selective resolution of some mixtures.  相似文献   

16.
Li LS  Liu M  Da SL  Feng YQ 《Talanta》2004,63(2):433-441
The chromatographic behavior of some nucleosides, pyrimidines and purines on a new p-tert-butyl-calix[8]arene-bonded silica gel stationary phase (CABS) were studied by high performance liquid chromatography. Their retention behavior on CABS were compared with those on ODS. The influence of mobile phase variables, such as methanol content, pH and ionic strength on the retention behavior were studied. Some nucleosides, pyrimidines and purines on CABS were successfully separated. The results show that the calix[8]arene-bonded phase exhibits high selectivities for the above analytes in high aqueous mobile phases. According to the chromatographic data, it is indicated that hydrophobic interaction, hydrogen-bonding interaction, and dipole-dipole interaction are mainly responsible for the retention behavior. In addition, in some extent, the vertical stacking action of the analytes on CABS can also change the retention behavior. CABS was superior to ODS in the routine fast separation of nucleosides and bases.  相似文献   

17.
We investigated the mechanisms involved in the retention of various peptides on a stationary phase embedded with a quaternary ammonium group (BS C23), by high-performance liquid chromatography. This was compared with peptide retention on a conventional reversed-phase C18 (RP C18) column under isocratic conditions, to understand better the various mechanisms involved. Chromatographic characterization of the two stationary phases with “model” compounds showed that BS C23 is less hydrophobic than RP C18 and induces electrostatic interaction (attraction or repulsion) with ionized compounds. If reversed-phase partitioning was the predominant retention phenomenon, for both stationary phases, the retention mechanisms in BS C23 provided different selectivity to that of RP C18. Electrostatic attraction or repulsion was clearly observed between peptides and the permanent positively charged group embedded in BS C23 depending on the pH. For most of the peptides, a weak anion-exchange mechanism was observed on the quaternary ammonium-embedded stationary phase if mobile phases at neutral pH and low ionic strengths were employed.  相似文献   

18.
A new zirconia-based stationary phase (DPZ) was prepared by modifying zirconia with dodecylamine-N,N-dimethylenephosphonic acid (DDPA). DDPA was adsorbed on zirconia with only one phosphonic group, with the other being free. Besides the hydrophobic interaction provided by nonpolar dodecyl, DPZ also has dipolar interaction, ion-exchange or electrostatic repellent interaction provided by the free phosphonic group and amino group at different conditions. Separation of bases on this stationary phase was achieved with satisfaction owing to the various retention mechanisms. The influence of methanol content, pH value, ion types, and ionic strength of mobile phase are studied in detail. Translated from Chinese Journal of Chromatography, 2005, 23(1) (in Chinese)  相似文献   

19.
张淑琼  邹凤平  李烃 《化学学报》2009,67(22):2619-2623
合成了分离蛋白质的乙二醇-磷霉素钠改性氧化锆高效液相色谱固定相, 通过漫反射红外光谱、元素分析等分析方法对该固定相进行了表征. 以溶菌酶、核糖核酸酶A、细胞色素C和糜蛋白酶四种标准碱性蛋白质为探针, 系统地考察了固定相的疏水相互作用色谱性能. 结果表明, 乙二醇-磷霉素改性氧化锆固定相对蛋白质有一定的保留, 表现出较高的分离选择性.  相似文献   

20.
对蛋白质在离子交换柱上选择民性和非吸附特性进行了研究。蛋白质在有机磷酸锆阳离子色谱柱上,其保留作用随流动相pH值在离子强度的增加而减小;蛋白质在强阳离子和强阴离子色谱柱上的保留作用,即是流动相中的pH值等于蛋白质的等当点,其净电荷为零。不册蛋白质仍有不同程度的保留,这主要是由于蛋白质的三维结构使电荷 密度的大小和分布的不均匀以及离子交换填料表面性质的影响。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号