首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This work investigates the effects of ionic strength and protein characteristics on adsorption and transport of lysozyme, BSA, and IgG in agarose-based cation exchangers with short ligand chemistry and with charged dextran grafts. In all cases, the adsorption equilibrium capacity decreased with increasing salt. However, the adsorption kinetics was strongly influenced by the adsorbent structure and protein characteristics. For the smaller and positively charged lysozyme, the effective pore diffusivity was only weakly dependent on salt for the dextran-free media, but declined sharply with salt for the dextran-grafted materials. For this protein, the dextran grafts enhanced the adsorption kinetics at low salt, but the enhancement vanished at higher salt concentrations. For BSA, which was near its isoelectric point for the experimental conditions studied, the effective diffusivity was low for all materials and almost independent of salt. Finally, for the larger and positively charged IgG, the effective diffusivity varied with salt, reaching an apparent maximum at intermediate concentrations for both dextran-free and dextran-grafted media with the kinetics substantially enhanced by the dextran grafts for these conditions. Microscopic observations of the particles during protein adsorption at low ionic strengths showed transient patterns characterized by sharp adsorption fronts for all materials. A theory taking into account surface or adsorbed phase diffusion with electrostatic coupling of diffusion fluxes is introduced to explain the mechanism for the enhanced adsorption kinetics observed for the positively charged proteins.  相似文献   

2.
There is continued interest in the development of stationary phases for protein chromatography that can provide high resolution at elevated flow rates of the mobile phase. When using porous particles, resolution and dynamic binding capacity decline rapidly as the flow rate is increased. Monolithic columns have been developed to overcome these limitations. However, there are difficulties in manufacturing homogeneous larger scale monoliths. In this paper we investigate the morphology and performance characteristics of columns based on new ion exchangers obtained by mechanically disrupting continuous beds of acrylamido-based polymeric media. Near colloidal suspensions of loose particles obtained with this procedure can be flow-packed in ordinary chromatography columns resulting in beds of unexpectedly high hydraulic permeability. Columns up to 2.2 cm in diameter were studied with both Q and S functionalized media. The hydraulic permeability and interparticle porosity of these columns were rather high. The permeabilities of the S and Q media were 1.5 x 10(-13) and 2.4 x 10(-13) m2, respectively, while the corresponding porosities were 60 and 70%. These porosity values are similar to those of monoliths, suggesting that these particles assemble under flow to give high-porosity bridged structures. The structure of these packed beds was further characterized by embedding small packed columns in resins and obtaining sections for microscopic observation. The sections reveal the presence of small aggregates of non-porous 1-3 microm particles, surrounded by flow channels several micrometers in size. The height equivalent to a theoretical plate under isocratic and gradient elution conditions and the dynamic binding capacity were determined for several proteins and were found to be virtually independent of flow.  相似文献   

3.
The thermodynamic modeling of protein adsorption on mixed-mode adsorbents functionalized with ligands carrying both hydrophobic and electrostatic groups was undertaken. The developed mixed mode isotherm was fitted with protein adsorption data obtained for five different proteins on four different mixed mode adsorbents by 96-well microtitre plate high throughput batch experiments on a robotic workstation. The developed mixed mode isotherm was capable of describing the adsorption isotherms of all five proteins (having widely different molecular masses and iso-electric points) on the four mixed mode adsorbents and over a wide range of salt concentrations and solution pH, and provided a unique set of physically meaningful parameters for each resin-protein-pH combination. The model could capture the typically observed minimum in mixed mode protein adsorption and predict the precise salt concentration at which this minimum occurs. The possibility of predicting the salt concentration at which minimum protein binding occurs presents new opportunities for designing better elution strategies in mixed mode protein chromatography. Salt-protein interactions were shown to have important consequences on mixed mode protein adsorption when they occur. Finally, the mixed mode isotherm also gave very good fit with literature data of BSA adsorption on a different mixed mode adsorbent not examined in this study. Hence, the mixed mode isotherm formalism presented in this study can be used with any mixed mode adsorbent having the hydrophobic and electrostatic functional groups. It also provides the basis for detailed modeling and optimization of mixed mode chromatographic separation of proteins.  相似文献   

4.
Custom-synthesized variants of the commercial Capto S resin were used to examine the effects of resin charge density and dextran content on protein adsorption and intraparticle uptake. For the small protein lysozyme, resin charge density had the greatest effect on equilibrium capacity, consistent with calculations suggesting that lysozyme capacity should be limited by the available charge on the resin. Isocratic retention data and confocal microscopy imaging for this protein revealed a consistent ordering of the resins linking stronger protein-resin interactions with higher static capacities but slower intraparticle uptake rates over the range of properties studied. For the larger protein lactoferrin, it was found that increasing dextran content led to increased protein exclusion from the dextran layer, but that increasing resin charge density helped overcome the exclusion, presumably due to the increased electrostatic attraction between the resin and protein. Collectively examining the lysozyme and lactoferrin data along with information from previous studies suggests that a trade-off in maximizing dynamic capacities should exist between static capacities that increase to a finite extent with increased resin charge density and uptake rates that decrease with increased charge density. Column breakthrough data for lysozyme and lactoferrin appear to support the hypothesis, though it appears that whether a resin charge density is low or high must be considered in relation to the protein charge density. Using these trends, this work could be useful in guiding resin selection or design.  相似文献   

5.
A type of mixed‐mode chromatography was integrated with high‐performance liquid chromatography for protein analysis and separation. The chromatographic behavior was tested using bovine serum albumin and lysozyme as model proteins. For the mixed‐mode column, the silica beads were activated with γ‐(2,3‐epoxypropoxy)‐propytrimethoxysilane and coupled with 4‐mercaptopyridine as the functional ligand. The effects of pH, salt, and the organic solvent conditions of the mobile phase on the retention behavior were studied, which provided valuable clues for separation strategy. When eluted with a suitable pH gradient, salt concentration gradient, and acetonitrile content gradient, the separation behavior of bovine serum albumin and lysozyme could be controlled by altering the conditions of the mobile phase. The results indicated this type of chromatography might be a useful method for protein analysis and separation.  相似文献   

6.
The control of aggregate levels in recombinant protein based drugs is a primary concern during process development and manufacture. In recent years, a novel class of dextran-grafted ion exchange matrices has gained popularity for process scale protein purification due to increased mass transfer rates and higher dynamic binding capacity compared to conventional matrices. Using bovine serum albumin and a monoclonal antibody as model proteins, we studied Sepharose FF and Sepharose XL ion exchangers for the separation of protein aggregates. Experimental results comparing linear gradient elution, stepwise elution, and flow-through chromatography for aggregate separation are described. Differences in performance for the various ion exchangers are discussed and modeled. Strategies for the optimization of protein aggregate separation are provided.  相似文献   

7.
This article describes the synthesis, chromatographic characterization, and performance evaluation of analytical (100 x 4.6 mm id) and semipreparative (100 x 10 mm id) monolithic silica columns with mixed-mode RP/weak anion-exchange (RP/WAX) surface modification. The monolithic RP/WAX columns were obtained by immobilization of N-(10-undecenoyl)-3-aminoquinuclidine onto thiol-modified monolithic silica columns (Chromolith) by a radical addition reaction. Their chromatographic characterization by Engelhardt and Tanaka tests revealed slightly lower hydrophobic selectivities than C-8 phases, as well as higher polarity and also improved shape selectivity than RP-18e silica rods. The surface modification enabled separation by both RP and anion-exchange chromatography principles, and thus showed complementary selectivities to the RP-18e monoliths. The mixed-mode monoliths have been tested for the separation of peptides and turned out to be particularly useful for hydrophilic acidic peptides, which are usually insufficiently retained on RP-18e monolithic columns. Compared to a corresponding particulate RP/WAX column (5 microm, 10 nm pore diameter), the analytical RP/WAX monolith caused lower system pressure drops and showed, as expected, higher efficiency (e.g. by a factor of about 2.5 lower C-term for a tetrapeptide). The upscaling from the analytical to semipreparative column dimension was also successful.  相似文献   

8.
In this study, 3‐diethylamino‐1‐propyne was covalently bonded to the azide‐silica by a click reaction to obtain a novel dual‐function mixed‐mode chromatography stationary phase for protein separation with a ligand containing tertiary amine and two ethyl groups capable of electrostatic and hydrophobic interaction functionalities, which can display hydrophobic interaction chromatography character in a high‐salt‐concentration mobile phase and weak anion exchange character in a low‐salt‐concentration mobile phase employed for protein separation. As a result, it can be employed to separate proteins with weak anion exchange and hydrophobic interaction modes, respectively. The resolution and selectivity of the stationary phase were evaluated in both hydrophobic interaction and ion exchange modes with standard proteins, respectively, which can be comparable to that of conventional weak anion exchange and hydrophobic interaction chromatography columns. Therefore, the synthesized weak anion exchange/hydrophobic interaction dual‐function mixed‐mode chromatography column can be used to replace two corresponding conventional weak anion exchange and hydrophobic interaction chromatography columns to separate proteins. Based on this mixed‐mode chromatography stationary phase, a new off‐line two‐dimensional liquid chromatography technology using only a single dual‐function mixed‐mode chromatography column was developed. Nine kinds of tested proteins can be separated completely using the developed method within 2.0 h.  相似文献   

9.
To separate proteins with a wide distribution of pIs under the conditions compatible to online tryptic digestion (with preferable pH=8.0), weak anion and cation exchange chromatography (WAX/WCX) mixed‐bed microcolumn has been developed. With a mixture of five proteins with pIs ranging from 4.2 to 11.4, the effect of WAX/WCX ratio on the separation performance was investigated, and an optimum packing ratio of 1:1 w/w was obtained. Moreover, the undesirable hydrophobic interaction between the proteins and the stationary phase was suppressed with 10% ACN v/v added in the mobile phases. Under the optimized conditions compatible to tryptic digestion, basic and acidic proteins were resolved simultaneously, with RSDs of relative retention time on six columns less than 6%, indicating the good resolution and packing reproducibility. Furthermore, one RPLC fraction of proteins extracted from rat middle brain and the whole protein mixture extracted from rat liver were analyzed, respectively. The results demonstrated better separation performance on WAX/WCX microcolumns than that on both weak anion exchange chromatography and weak cation exchange chromatography at pH ~8. We anticipate that WAX/WCX microcolumns are promising for the integration of protein separation and tryptic digestion aiming at high‐throughput proteome study.  相似文献   

10.
A novel organic‐silica hybrid monolith was prepared through the binding of histidine onto the surface of monolithic matrix for mixed‐mode per aqueous and ion‐exchange capillary electrochromatography. The imidazolium and amino groups on the surface of the monolithic stationary phase were used to generate an anodic electro‐osmotic flow as well as to provide electrostatic interaction sites for the charged compounds at low pH. Typical per aqueous chromatographic behavior was observed in water‐rich mobile phases. Various polar and hydrophilic analytes were selected to evaluate the characteristics and chromatographic performance of the obtained monolith. Under per aqueous conditions, the mixed‐mode mechanism of hydrophobic and ion‐exchange interactions was observed and the resultant monolithic column proved to be very versatile for the efficient separations of these polar and hydrophilic compounds (including amides, nucleosides and nucleotide bases, benzoic acid derivatives, and amino acids) in highly aqueous mobile phases. The successful applications suggested that the histidine‐modified organic‐silica hybrid monolithic column could offer a wide range of retention behaviors and flexible selectivities toward polar and hydrophilic compounds.  相似文献   

11.
Phosphorylated carbohydrates are important intracellular metabolites and thus of prime interest in metabolomics research. Complications in their analysis arise from the existence of structural isomers that do have similar fragmentation patterns in MS/MS and are hard to resolve chromatographically. Herein, we present selective methods for the liquid chromatographic separation of sugar phosphates, such as hexose and pentose phosphates, 2‐ and 3‐phosphoglycerate, dihydroxyacetone phosphate and glyceraldehyde 3‐phosphate, as well as glucosamine 1‐ and 6‐phosphate utilizing mixed‐mode chromatography with reversed‐phase/weak anion‐exchangers and a charged aerosol detector. The best results were obtained when the reversed‐phase/weak anion‐exchanger column was operated under hydrophilic interaction liquid chromatography elution conditions. The effects of various chromatographic parameters were examined and are discussed on the basis of a simple stoichiometric displacement model for explaining ion‐exchange processes. Employed acidic conditions have led to the complete separation of α‐ and β‐anomers of glucose 6‐phosphate at low temperature. The anomers coeluted in a single peak at elevated temperatures (>40°C) (peak coalescence), while at intermediate temperatures on‐column interconversion with a plateau in‐between resolved anomer peaks was observed with apparent reaction rate constants between 0.1 and 27.8×10?4 s?1. Dynamic HPLC under specified conditions enabled to investigate mutarotation of phosphorylated carbohydrates, their interconversion kinetics, and energy barriers for interconversion. A complex mixture of six hexose phosphate structural isomers could be resolved almost completely.  相似文献   

12.
Three commercially available chiral capillary columns, Chirasil-Dex, BGB-176SE, and BGB-172, have been evaluated for the separation into enantiomers of the 19 chiral polychlorinated biphenyls (PCB) congeners stable at room temperature. The enantiomers of 15 chiral PCBs were, at least to some extent, separated using these beta-cyclodextrin based columns. Multidimensional techniques, such as heart-cut multi-dimensional gas chromatography (heart-cut MDGC) and comprehensive two-dimensional gas chromatography (GC x GC), were investigated for their ability to solve coelution problems with other PCBs present in commercial mixtures and real-life samples. Heart-cut MDGC improved the separation as compared to one-dimensional GC, and enantiomeric fractions of the investigated chiral PCBs could be determined free from interferences. However, limitations on the number of target compounds that can be transferred to the second column in a single run and, therefore, the time consumption, have led to the evaluation of GC x GC as an alternative for this type of analysis. With GC x GC, two column set-ups were tested, both having a chiral column as first-dimension column, and two different polar stationary phase columns in the second dimension. On using both column combinations, congeners 84, 91, 95, 132, 135, 136, 149, 174, and 176 could be determined free from coelutions with other PCBs. Results on the application of heart-cut MDGC to food samples such as milk and cheese are given, as well as the first results on the application of GC x GC to this type of samples.  相似文献   

13.
The analysis of peptides and proteins by CE is often desirable due to low sample consumption and possibilities for nondenaturing yet highly effective separations. However, adsorption to the inner surfaces of fused-silica capillaries often is detrimental to such analyses. This phenomenon is especially pronounced in the analysis of basic proteins and proteins containing exposed positively charged patches. To avoid wall interactions numerous buffer additives and static and dynamic wall coating principles have been devised. We previously showed (J. Chromatogr. A 2004, 1059, 215-222) that CE of the basic protein beta2-glycoprotein was rendered possible by an acidic pretreatment step, and we attributed this observation to the so-called pH hysteresis effect that influences the time for pH equilibration of the capillary wall and thus the effective wall charge and the electroosmotic mobility. We here investigate the effects of different pretreatment techniques on EOF values and on the rate of the deprotonation of silanol groups when performing the electrophoresis at neutral pH. We show the utility of this simple approach for the CE analysis of a number of basic proteins in plain silica capillaries at physiological pH.  相似文献   

14.
Dynamic binding capacity (DBC) of a monoclonal antibody on agarose based strong cation exchange resins is determined as a function of resin ligand density, apparent pore size of the base matrix, and protein charge. The maximum DBC is found to be unaffected by resin ligand density, apparent pore size, or protein charge within the tested range. The critical conductivity (conductivity at maximum DBC) is seen to vary with ligand density. It is hypothesized that the maximum DBC is determined by the effective size of the proteins and the proximity to which they can approach one another. Once a certain minimum resin ligand density is supplied, additional ligand is not beneficial in terms of resin capacity. Additional ligand can provide flexibility in designing ion exchange resins for a particular application as the critical conductivity could be matched to the feedstock conductivity and it may also affect the selectivity.  相似文献   

15.
A sensitive and specific LC-MS/MS assay for the determination of paclitaxel and its 3'p- and 6-alpha-hydroxy metabolites is presented. A 200 microL plasma aliquot was spiked with a 13C6-labeled paclitaxel internal standard and extracted with 1.0 mL tert-butylmethylether. Dried extracts were reconstituted in 0.1 M ammonium acetate-acetonitrile (1:1, v/v) and 25 microL volumes were injected onto the HPLC system. Separation was performed on a 150 x 2.1 mm C18 column using an alkaline eluent (10 mm ammonium hydroxide-methanol, 30:70, v/v). Detection was performed by positive ion electrospray followed by tandem mass spectrometry. The assay quantifies a range for paclitaxel from 0.25 to 1000 ng/mL and metabolites from 0.25 to 100 ng/mL using 200 microL human plasma samples. Validation results demonstrate that paclitaxel and metabolite concentrations can be accurately and precisely quantified in human plasma. This assay is now used to support clinical pharmacologic studies with paclitaxel.  相似文献   

16.
The effect of pH on the static adsorption capacity of immunoglobulin G, human serum albumin, and equine myoglobin was investigated for a set of five strong cation exchangers with the grafted tentacle layer having a different ligand density. A sharp maximum of adsorption capacity with pH was observed for adsorbents with a high ligand density. The results were elucidated using the protein structure and calculations of pK(a) of ionizable groups of surface basic residues. Inverse size-exclusion experiments were carried out to understand the relation between the adsorption capacity and pore accessibility of the investigated proteins.  相似文献   

17.
Casein is well known as a good protein emulsifier and beta-casein is the major component of casein and commercial sodium caseinate. Dye affinity adsorption is increasingly used for protein separation. beta-Casein adsorption onto Reactive Red 120 attached magnetic poly(2-hydroxyethyl methacrylate) (m-PHEMA) beads was investigated in this work. m-PHEMA beads (80-120 microm in diameter) were produced by dispersion polymerization. The dichlorotriazine dye Reactive Red 120 was attached covalently as a ligand. The dye attached beads, having a swelling ratio of 55% (w/w) and carrying different amounts of Reactive Red 120 (9.2 micromol . g(-1)-39.8 micromol . g(-1)), were used in beta-casein adsorption studies. The effects of the initial concentration, pH, ionic strength and temperature on the adsorption efficiency of dye attached beads were studied in a batch reactor. The non-specific adsorption on the m-PHEMA beads was 1.4 mg . g(-1). Reactive Red 120 attachment significantly increased the beta-casein adsorption up to 37.3 mg . g(-1). More than 95.4% of the adsorbed beta-casein was desorbed in 1 h in a desorption medium containing 1.0 M KSCN at pH 8.0. We concluded that Reactive Red 120 attached m-PHEMA beads can be applied for beta-casein adsorption without significant losses in the adsorption capacities.  相似文献   

18.
In this study, two mixed‐mode chromatography stationary phases (C8SAX and C8SCX) were evaluated and used to establish a two‐dimensional liquid chromatography system for the separation of traditional Chinese medicine. The chromatographic properties of the mixed‐mode columns were systematically evaluated by comparing with other three columns of C8, strong anion exchanger, and strong cation exchanger. The result showed that C8SAX and C8SCX had a mixed‐mode retention mechanism including electrostatic interaction and hydrophobic interaction. Especially, they were suitable for separating acidic and/or basic compounds and their separation selectivities could be easily adjusted by changing pH value. Then, several off‐line 2D‐LC systems based on the C8SAX in the first dimension and C8SAX, C8SCX, or C8 columns in the second dimension were developed to analyze a traditional Chinese medicine—Uncaria rhynchophylla. The two‐dimensional liquid chromatography system of C8SAX (pH 3.0) × C8SAX (pH 6.0) exhibited the most effective peak distribution. Finally, fractions of U. rhynchophylla prepared from the first dimension were successfully separated on the C8SAX column with a gradient pH. Thus, the mixed‐mode stationary phase could provide a platform to separate the traditional Chinese medicine in practical applications.  相似文献   

19.
The tandem use of hydrophilic interaction LC columns with RP columns in series configuration has resulted in the retention of both polar and nonpolar components in complex biological samples (mouse serum) in a single analysis. This approach successfully coupled various columns with orthogonal separation characteristics, employed a single solvent gradient program compatible with the two columns and used ESI coupled to a TOF mass spectrometer for detection. Ion suppression, a common problem in ESI, was virtually eliminated for components eluting with apparent capacity factors >0.7. Retention time reproducibility with the tandem columns performed over three days with over 100 injections was comparable to that observed for single columns alone. This method was applied to the analysis of a pooled mouse serum sample and afforded highly reproducible data for up to 3000 mass spectral features. This approach was implemented with a conventional LC–MS system and should find broad applicability in the comprehensive analysis of complex mixtures containing a wide range of compound polarities.  相似文献   

20.
A procedure for the preparation of a monolithic column for weak cation exchange chromatography was presented. The structure of the monolithic column was evaluated by mercury intrusion. The hydrodynamic and chromatographic properties of the monolithic column--such as back pressures at different flow rates, effects of pH on protein retention, dynamic loading capacity, recovery, and stability--were determined under conditions typical for ion-exchange chromatography. The prepared monolithic column might be used in a relatively broad pH range from 4.0 to 12.0 and exhibited an excellent separation to five proteins at the flow rates of both 1.0 and 8.0 mL/min, respectively. In addition, the prepared column was first used in the purification and simultaneous renaturation of recombinant human interferon gamma (rhIFN-gamma) in the extract solution with 7.0 mol/L guanidine hydrochloride. The purity and specific bioactivity of the purified rhIFN-gamma in only one chromatographic step were obtained to be 93% and 7.8 x 10(7) IU/mg, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号