首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A liquid chromatography (LC) method and an ultraviolet (UV) spectrophotometric method were developed and validated for quantitative determination of amlodipine in tablets and compounded capsules. The isocratic LC analyses were performed on an RP18 column using a mobile phase composed of 0.1% (v/v) ortho-phosphoric acid (pH 3.0) -acetonitrile (60 + 40, v/v) at a flow rate of 1.0 mL/min. The UV spectrophotometric method was performed at 238 nm. The analytical methods were validated according to International Conference on Harmonization Guidelines. The calibration graphs were linear [correlation coefficient (r) > 0.999] in the studied concentration range of 10-30 microg/mL for LC and 10-35 microg/mL for UV spectrophotometry. The relative standard deviation values for intraday and interday precision studies were less than 2%, and the accuracy was greater than 98% for both methods. The specificity of the LC method was proved using forced degradation. Statistical analyses showed no significant difference between the results obtained by the 2 methods. The proposed methods are precise and accurate and can be applied directly and easily to the oral pharmaceutical preparations of amlodipine.  相似文献   

2.
Column high-performance liquid chromatographic (LC) and UV spectrophotometric methods for the quantitative determination of citalopram, a potent and selective serotonin reuptake inhibitor, in tablets were developed. The parameters linearity, precision, accuracy, specificity, robustness, limit of detection, and limit of quantitation were studied according to International Conference on Harmonization guidelines. Chromatography was carried out by the reversed-phase technique on an ACE C18 column with a mobile phase composed of 0.30% triethylamine solution-acetonitrile (55 + 45, v/v) adjusted to pH 6.6 with 10% ortho-phosphoric acid at a flow rate of 1.0 mL/min and 25 degrees C. The UV spectrophotometric method was performed at 239 nm. The linearity of the LC method was in the range of 10.00-70.00 microg/mL, and 2.50-17.50 microg/mL for the UV spectrophotometric method. The interday and intraday assay precision was < 1.5% (relative standard deviation) for the LC and UV spectrophotometric methods. The recoveries were in the range 100.70-101.35% for the LC method and 98.48-98.65% for the UV spectrophotometric method. Statistical analysis by Student's t-test showed no significant difference between the results obtained by the 2 methods. The proposed methods are highly sensitive, precise, and accurate and can be used for the reliable quantitation of citalopram in tablets.  相似文献   

3.
This research paper describes validated reversed-phase high-performance column liquid chromatographic (RP-HPLC) and first-derivative UV spectrophotometric methods for the estimation of voriconazole (VOR) in oral suspension powder. The RP-HPLC separation was achieved on Phenomenex C18 column (250 x 4.6 mm id, 5 microm particle size) using water-acetonitrile (40 + 60, v/v; pH adjusted to 4.5 +/- 0.02 with acetic acid) as the mobile phase at a flow rate of 1.4 mL/min and ambient temperature. Quantification was achieved with photodiode array detection at 255 nm over the concentration range of 0.1-1 microg/mL with mean recovery of 99.49 +/- 0.83% for VOR by the RP-HPLC method. Quantification was achieved with UV detection at 266 nm over the concentration range of 8-20 microg/mL with mean recovery of 99.74 +/- 0.664% for VOR by the first-derivative UV spectrophotometric method. These methods are simple, precise, and sensitive, and they are applicable for the determination of VOR in oral suspension powder.  相似文献   

4.
5.
A new RP-LC method and two new spectrophotometric methods, principal component regression (PCR) and first derivative spectrophotometry, are proposed for simultaneous determination of diflucortolone valerate (DIF) and isoconazole nitrate (ISO) in cream formulations. An isocratic system consisting of an ACE C18 column and a mobile phase composed of methanol-water (95 + 5, v/v) was used for the optimal chromatographic separation. In PCR, the concentration data matrix was prepared by using synthetic mixtures containing these drugs in methanol-water (3 + 1, v/v). The absorbance data matrix corresponding to the concentration data matrix was obtained by measuring the absorbances at 29 wavelengths in the range of 242-298 nm for DIF and ISO in the zero-order spectra of their combinations. In first derivative spectrophotometry, dA/dlambda values were measured at 247.8 nm for DIF and at 240.2 nm for ISO in first derivative spectra of the solution of DIF and ISO in methanol-water (3 + 1, v/v). The linear ranges were 4.00-48.0 microg/mL for DIF and 50.0-400 microg/mL for ISO in the LC method, and 2.40-40.0 microg/mL for DIF and 60.0-260 microg/mL for ISO in the PCR and first derivative spectrophotometric methods. These methods were validated by analyzing synthetic mixtures. These three methods were successfully applied to two pharmaceutical cream preparations.  相似文献   

6.
Reversed-phase liquid chromatography (LC) and LC/tandem mass spectrometry (LC/MS/MS) methods were developed and validated for the determination of etoricoxib in pharmaceutical dosage forms. The LC method was performed by reversed-phase chromatography on a Synergi fusion C18 column (150 x 4.6 mm id) maintained at ambient temperature. The mobile phase consisted of 0.01 M phosphoric acid, pH 3.0-acetonitrile (62 + 38, v/v) at a flow rate of 1.0 mL/min, and photodiode array detection at 234 nm was used. The chromatographic separation was obtained within 7.0 min, and calibration curves were linear in the concentration range of 0.02-150 microg/mL. The LC/MS/MS method was performed on a Luna C18 column (50 x 3.0 mm id). The mobile phase consisted of acetonitrile-water (95 + 5)-0.1% acetic acid (90 + 10, v/v). Detection was performed by positive electrospray ionization in the multiple reaction monitoring mode, monitoring the transitions 359.3 > 280.0 and 332.0 > 95.0 for etoricoxib and piroxicam (internal standard), respectively. The chromatographic separation was obtained within 2.0 min, and calibration curves were linear in the concentration range of 1-5000 ng/mL. Validation parameters, such as specificity, linearity, precision, accuracy, and robustness, were evaluated, which gave results within the acceptable range for both methods. Moreover, the proposed methods were successfully applied for routine quality control analysis of pharmaceutical products and showed significant correlation (r = 0.9999) of the results.  相似文献   

7.
An accurate, simple, reproducible, and sensitive HPLC method was developed and validated for the simultaneous determination of atorvastatin calcium, ezetimibe, and fenofibrate in a tablet formulation. The analyses were performed on an RP C18 column, 150 x 4.60 mm id, 5 pm particle size. The mobile phase methanol-acetonitrile-water (76 + 13 + 11, v/v/v), was pumped at a constant flow rate of 1 mL/min. UV detection was performed at 253 nm. Retention times of atorvastatin calcium, ezetimibe, and fenofibrate were found to be 2.25, 3.68, and 6.41 min, respectively. The method was validated in terms of linearity, precision, accuracy, LOD, LOQ, and robustness. The response was linear in the range 2-10 microg/mL (r2 = 0.998) for atorvastatin calcium, 2-10 microg/mL (r2 = 0.998) for ezetimibe, and 40-120 microg/mL (r2 = 0.998) for fenofibrate. The developed method can be used for routine quality analysis of the drugs in the tablet formulation.  相似文献   

8.
Two simple and accurate methods for analysis of nebivolol hydrochloride (NEB) and hydrochlorothiazide (HCTZ) in their combined dosage forms were developed using first-order derivative spectrophotometry and reversed-phase liquid chromatography (LC). NEB and HCTZ in their combined dosage forms (tablets) were quantified using first-derivative responses at 294.6 and 334.6 nm in the spectra of their solutions in methanol. The calibration curves were linear in the concentration range of 8-40 microg/mL for NEB and 10-60 microg/mL for HCTZ. LC analysis was performed on a Phenomenex Gemini C18 column (250 x 4.6 mm id, 5 microm particle size) in the isocratic mode with 0.05 M potassium dihydrogen phosphate-acetonitrile-methanol (30 + 20 + 50, v/v/v; pH 4) mobile phase at a flow rate of 1 mL/min. Detection was made at 220 nm. Both of the drugs and the internal standard (ezetimibe) were well resolved with retention times of 5.1 min for NEB, 2.9 min for HCTZ, and 8.2 min for ezetimibe. The calibration curves were linear in the concentration range of 1-14 microg/mL for NEB and 0.3-28 microg/mL for HCTZ. Both methods were validated and found to be accurate, precise, and specific, and results were compared statistically. Developed methods were successfully applied for the estimation of NEB and HCTZ in their combined dosage forms.  相似文献   

9.
Three simple and sensitive spectrophotometric, difference spectroscopic, and liquid chromatographic (LC) methods are described for the determination of cefixime. The first method is based on the oxidative coupling reaction of cefixime with 3-methyl-2-benzothiazolinon hydrazone HCI in presence of ferric chloride. The absorbance of reaction product was measured at the maximum absorbance wavelength (wavelength(max)), 630 nm. The difference spectroscopic method is based on the measurement of absorbance of cefixime at the absorbance maximum, 268 nm, and minimum, 237 nm. The measured value was the amplitude of maxima and minima between 2 equimolar solutions of the analyte in different chemical forms, which exhibited different spectral characteristics. The conditions were optimized, and Beer's law was obeyed for cefixime at 1 to 16 microg/mL and 10 to 50 microg/mL, respectively. The third method, high-performance LC, was developed for the determination of cefixime using 50 mM potassium dihydrogen phosphate (pH 3.0)-methanol (78 + 22, v/v) as the mobile phase and measuring the response at wavelength(max) 286 nm. The analysis was performed on a Lichrospher RPC18 column. The calibration curve was obtained for cefixime at 5 to 250 microg/mL, and the mean recovery was 99.71 +/- 0.01%. The methods were validated according to the guidelines of the U.S. Pharmacopoeia and also assessed by applying the standard addition technique. The results obtained in the analysis of dosage forms agreed well with the contents stated on the labels.  相似文献   

10.
A simple, rapid, and stability-indicating HPLC method has been developed, fully validated, and applied to the quantification of paracetamol, pseudoephedrine hydrochloride, and chlorpheniramine maleate in a pharmaceutical formulation, using hydrochlorothiazide as an internal standard. Chromatographic separation was achieved isocratically on an RP porous graphitized carbon analytical column (125 x 2.1 mm id, particle size 5 microm) using 5.0 mM ammonium acetate-acetonitrile (35 + 65, v/v) mobile phase at a flow rate of 0.50 mL/min. UV spectrophotometric detection at 220 nm was used. The method had linear calibration curves over the range of 30-70 microg/mL for paracetamol, 1.8-4.2 microg/mL for pseudoephedrine hydrochloride, and 120-280 ng/mL for chlorpheniramine maleate. The intraday and interday RSD values were less than 3.2% for all compounds, while the relative error was less than 2.9%. Accelerated stability studies performed under various stress conditions proved the selectivity of the method. The developed method was applied successfully to QC and content uniformity tests of commercial tablets.  相似文献   

11.
High-performance liquid chromatographic (LC) and ultraviolet derivative spectrophotometric (UVD) methods were developed and validated for the quantitative determination of epinastine hydrochloride in coated tablets. LC was performed on a reversed-phase RP-18 column with a mobile phase composed of 0.3% triethylamine (pH adjusted to 4.0 with 10% orthophosphoric acid)-methanol (60 + 40, v/v). The first-order derivative method was performed at 243.8 nm using HCI and methanol as the solvent. The methods were validated according to U.S. Pharmacopoeia and International Conference on Harmonization guidelines. The statistical analysis by Student's t-test showed no significant difference between the results obtained by the 2 methods. The proposed methods were found to be simple, rapid, precise, accurate, robust, and sensitive, allowing perfect interchange. The LC and UVD methods can be used in the routine quantitative determination of the epinastine hydrochloride in coated tablets.  相似文献   

12.
Four different stability-indicating procedures are described for determination of tiapride in pure form, dosage form, and human plasma. Second derivative (D2), first derivative of ratio spectra (1DD), spectrofluorimetric, and high-performance column liquid chromatographic (LC) methods are proposed for determination of tiapride in presence of its acid-induced degradation products, namely 2-methoxy-5-(methylsulfonyl) benzoic acid and 2-diethylaminoethylamine. These approaches were successfully applied to quantify tiapride using the information included in the absorption, excitation, and emission spectra of the appropriate solutions. In the D2 method, Beer's law was obeyed in the concentration range of 1.5-9 microg/mL with a mean recovery of 99.94 +/- 1.38% at 253.4 nm using absolute ethanol as a solvent. In 1DD, which is based on the simultaneous use of the first derivative of ratio spectra and measurement at 245 nm in absolute ethanolic solution, Beer's law was obeyed over a concentration range of 1.5-9 microg/mL with mean recovery 99.64 +/- 1.08%. The spectrofluorimetric method is based on the determination of tiapride native fluorescence at 339 nm emission wavelength and 230 nm excitation wavelength using water-methanol (8 + 2, v/v). The calibration curve was linear over the range of 0.2-3 microg/mL with mean recovery of 99.66 +/- 1.46%. This method was also applied for determination of tiapride in human plasma. A reversed-phase LC method performed at ambient temperature was validated for determination of tiapride using methanol-deionized water-triethylamine (107 + 93 + 0.16, v/v/v) as the mobile phase. Sulpiride was used as an internal standard at a flow rate of 1 mL/min with ultraviolet detection at 214 nm. A linear relation was obtained over a concentration range of 2-30 microg/mL with mean recovery of 99.66 +/- 0.9%. Results were statistically analyzed and compared with those obtained by applying the reference method. They proved both accuracy and precision.  相似文献   

13.
Three new, different, simple, sensitive, and accurate methods were developed for quantitative determination of nifuroxazide (I) and drotaverine hydrochloride (II) in a binary mixture. The first method was spectrophotometry, which allowed determination of I in the presence of II using a zero-order spectrum with an analytically useful maximum at 364.5 nm that obeyed Beer's law over a concentration range of 2-10 microg/mL with mean percentage recovery of 100.08 +/- 0.61. Determination of II in presence of I was obtained by second derivative spectrophotometry at 243.6 nm, which obeyed Beer's law over a concentration range of 2-10 microg/mL with mean recovery of 99.82 +/- 1.46%. The second method was spectrodensitometry, with which both drugs were separated on a silica gel plate using chloroform-acetone-methanol-glacial acetic acid (6 + 3 + 0.9 + 0.1) as the mobile phase and ultraviolet (UV) detection at 365 nm over a concentration range of 0.2-1 microg/band for both drugs, with mean recoveries of 99.99 +/- 0.15 and 100.00 +/- 0.34% for I and II, respectively. The third method was reversed-phase liquid chromatography using acetonitrile-water (40 + 60, v/v; adjusted to pH 2.55 with orthophosphoric acid) as the mobile phase and pentoxifylline as the internal standard at a flow rate of 1 mU/min with UV detection at 285 nm at ambient temperature over a concentration range of 2-10 microg/mL for both drugs, with mean recoveries of 100.24 +/- 1.51 and 100.08 +/- 0.78% for I and II, respectively. The proposed methods were checked using laboratory-prepared mixtures and were successfully applied for the analysis of pharmaceutical formulations containing the above drugs with no interference from other dosage form additives. The validity of the suggested procedures was further assessed by applying the standard addition technique which was found to be satisfactory, and the percentage recoveries obtained were in accordance with those given by the EVA Pharma reference spectrophotometric method.  相似文献   

14.
The dietary sources of CoQ10 and the evaluation of CoQ10 in dairy products were characterized. For quantitation of CoQ10 in food samples, 2 liquid chromatography (LC) methods with UV and mass spectrometry (MS) detections were developed. LC with UV detection was performed at 25 degrees C on a Hyperclone ODS 5 microm 150 x 4.6 mm column with mobile phase consisting of methanol-ethanol-2-propanol (70 + 15 + 15, v/v/v). Flow rate was 1.0 mL/min. Retention time of CoQ10 was 10.9 +/- 0.1 min. The method was sensitive [limit of detection (LOD) = 0.2 mg/kg], reproducible [relative standard deviation (RSD) = 3:0%), and linear up to 25 mg/kg (R > 0.999). LC/MS analysis was performed on a LUNA C18 3 microm, 150 x 4.6 mm column, using mobile phase consisting of ethanol-dioxane-acetic acid (9 + 1 + 0.01, v/v/v), flow rate was 0.6 mL/min, and the retention time of CoQ10 was 4.1 +/- 0.1 min. Identification and quantitation were performed with a Finnigan-LCQ mass detector in positive atmospheric pressure chemical ionization mode. Mass spectra were obtained in selected-ion monitoring mode; molecular mass (M+H)+ m/z 863.4 +/- 1 was used for quantitative determination. MS detection is more sensitive than UV detection (LOD = 0.1 mg/kg), less reproducible (RSD = 4.0%), and linear in selected range. Analytical recoveries are 75-90% and depend on the ratio between the amount of fat in the matrix and the concentration of CoQ10 in the sample. Some soybean milk products were analyzed together with different cow, goat, and sheep milk products. Concentrations obtained with LC and LC/MS were compared with a few accessible results available from the literature. Concentrations varied from 0 ppm in soybean milk to nearly 2 ppm in fresh milk from local farms.  相似文献   

15.
Cefuroxime lysine is a new second‐generation cephalosporins, which can penetrate the blood–brain barrier to cure the meningitis. In order to investigate its acute toxicokinetic study after intraperitoneal injection of 675 mg/kg cefuroxime lysine, a sensitive and clean ultra‐fast liquid chromatography–tandem mass spectrometry (UFLC‐MS/MS) method for the determination of cefuroxime lysine in microdialysate samples was developed and validated, which was compared with UFLC‐UV as a reference method. Chromatographic separation was performed on a Shim‐pack XR‐ODS C18 column (75 × 3.0 mm, 2.2 µm), with an isocratic elution of 0.1% formic acid in acetonitrile–0.1% formic acid in water (45:55, v/v) for LC‐MS and acetonitrile–20 mm potassium dihydrogen phosphate (pH 3.0,20:80, v/v) for LC‐UV. The lower limit of detection was 0.01 µg/mL for LC‐MS and 0.1 µg/mL for LC‐UV method, with the same corresponding linearity range of 0.1–50 µg/mL. The intra‐ and inter‐day precisions (relative standard deviation) for both methods were from 1.1 to 8.9%, while the accuracy was all within ±10.9%. The results of both methods were finally compared using paired t‐test; the results indicated that the concentrations measured by the two methods correlated significantly (p < 0.05), which suggested that the two methods based on LC‐MS and LC‐UV were suitable for the acute toxicokinetic study. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

16.
A fast and reliable method for the determination of repaglinide is highly desirable to support formulation screening and quality control. A first-derivative UV spectroscopic method was developed for the determination of repaglinide in tablet dosage form and for dissolution testing. First-derivative UV absorbance was measured at 253 nm. The developed method was validated for linearity, accuracy, precision, limit of detection (LOD), and limit of quantitation (LOQ) in comparison to the U.S. Pharmacopeia (USP) column high-performance liquid chromatographic (HPLC) method. The first-derivative UV spectrophotometric method showed excellent linearity [correlation coefficient (r) = 0.9999] in the concentration range of 1-35 microg/mL and precision (relative standard deviation < 1.5%). The LOD and LOQ were 0.23 and 0.72 microg/mL, respectively, and good recoveries were achieved (98-101.8%). Statistical comparison of results of the first-derivative UV spectrophotometric and the USP HPLC methods using the t-test showed that there was no significant difference between the 2 methods. Additionally, the method was successfully used for the dissolution test of repaglinide and was found to be reliable, simple, fast, and inexpensive.  相似文献   

17.
A rapid and selective HPLC‐UV method was developed for the quantification of linezolid (LNZ) in human plasma and bronchoalveolar lavage (BAL) at the concentrations associated with therapy. Plasma samples were extracted by solid‐phase extraction followed by evaporation to dryness and reconstitution in mobile phase solution. The chromatographic separation was carried out on a C18 column with an isocratic mobile phase consisting of dihydrogen phosphate buffer 50 mm (pH 3.5) and acetonitrile (60:40 v/v). The detection was performed using a photodiode array. Under these conditions, a single chromatographic run could be completed within 12 min. The method was validated by estimating the precision and the accuracy for inter‐ and intra‐day analysis in the concentration range of 25–25600 ng/mL. The method was linear over the investigated range with all the correlation coefficients R > 0.999. The intra‐ and inter‐day precision was within 8.90% and the accuracy ranged from ?4.76 to +5.20%. This rapid and sensitive method was fully validated and could be applied to pharmacokinetic study for the determination of LNZ levels in human plasma and BAL samples. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

18.
Three simple, rapid, and accurate methods, i.e., the derivative ratio spectra-zero-crossing method (method I), double divisor-ratio spectra derivative method (method II), and column reversed-phase high-performance liquid chromatographic (RP-HPLC) method (method III) were developed for the simultaneous determination of doxylamine succinate (DOX), pyridoxine hydrochloride (PYR), and folic acid (FA) in their ternary mixtures and in tablets. In methods I and II, the calibration graphs were linear in the range of 2.5-80, 1.0-40, and 1.0-30 microg/mL for DOX, PYR, and FA, respectively. In the HPLC method, the separation of these compounds was performed using mobile phase consisting of 0.05 M phosphate buffer (pH 6.3)-methanol-acetonitrile (50 + 20 + 30, v/v/v), and UV detection was performed at 263 nm. Linearity was observed between the concentrations of the analytes and peak areas [correlation coefficient (r) > or =0.9998] in the concentration range of 1.0-200, 4.0-600, and 4.0-600 microg/mL for DOX, PYR, and FA, respectively. The standard deviation of retention time in method III was 0.011, 0.015, and 0.016 for DOX, PYR, and FA, respectively. The precision studies for all of the methods gave relative standard deviation values of <2%. The results obtained from the methods were statistically compared by means of Student's t-test and the variance ratio F-test. It was concluded that all of the developed methods were equally accurate, sensitive, and precise. These methods could be applied to determine DOX, PYR, and FA in their combined dosage forms.  相似文献   

19.
This paper describes validated high-performance liquid chromatographic (LC) and high-performance thin-layer chromatographic (TLC) methods for the simultaneous estimation of olanzapine and fluoxetine in pure powder and tablet formulations. The LC separation was achieved on a Lichrospher 100 RP-180, C18 column (250 mm, 4.0 mm id, 5 microm) using 0.05 M potassium dihydrogen phosphate buffer (pH 5.6 adjusted with o-phosphoric acid)-acetonitrile (50 + 50, v/v) as the mobile phase at a flow rate of 1 mL/min and ambient temperature. The TLC separation was achieved on aluminum sheets coated with silica gel 60F254 using methanol-toluene (40 + 20, v/v) as the mobile phase. Quantitation was achieved by measuring ultraviolet absorption at 233 nm over the concentration range of 10-70 and 40-280 microg/mL with mean recovery of 99.54 +/- 0.89 and 99.73 +/- 0.58% for olanzapine and fluoxetine, respectively, by the LC method. Quantitation was achieved by measuring ultraviolet absorption at 233 nm over the concentration range of 100-800 and 400-3200 ng/spot with mean recovery of 101.53 +/- 0.06 and 101.45 +/- 0.35% for olanzapine and fluoxetine, respectively, by the TLC method with densitometry. These methods are simple, precise, and sensitive, and they are applicable for simultaneous determination of olanzapine and fluoxetine in tablet formulations.  相似文献   

20.
New, simple, rapid, and precise reversed-phase high-performance liquid chromatographic (LC) methods were developed for the simultaneous determination of chlorzoxazone (CH) and ketoprofen (KT) in binary mixtures and in ternary mixtures containing the CH degradation product, 2-amino-4-chlorophenol (CD). The analytes were separated by LC on a Lichrosphere 60 C18 column (250 x 4 mm, 5 microm). The mobile phases, methanol-water (40:60, v/v) at 1 mL/min and methanol-0.05% phosphoric acid (60:40, v/v, pH 2.81) at 1.5 mL/min, satisfactorily resolved the binary and ternary mixtures, respectively. The UV detector was operated at 280 nm for the determination of CH and at 254 nm for the determination of KT and CD. Linearity, accuracy, and precision were found to be acceptable over the concentration ranges of 20-240 and 5-60 microg/mL for CH and KT, respectively, in the binary mixtures and 50-300, 10-60, and 20-160 microg/mL for CH, KT, and CD, respectively, in the ternary mixtures. The optimized methods proved to be specific, robust, and accurate for the quality control of CH and KT in pharmaceutical preparations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号