相似文献
 共查询到20条相似文献,搜索用时 789 毫秒
1.
This paper reviews the problems encountered in eleven studies of Sr isotope analysis using laser ablation multicollector inductively coupled plasma mass spectrometry (LA-MC-ICPMS) in the period 1995–2006. This technique has been shown to have great potential, but the accuracy and precision are limited by: (1) large instrumental mass discrimination, (2) laser-induced isotopic and elemental fractionations and (3) molecular interferences. The most important isobaric interferences are Kr and Rb, whereas Ca dimer/argides and doubly charged rare earth elements (REE) are limited to sample materials which contain substantial amounts of these elements. With modern laser (193 nm) and MC-ICPMS equipment, minerals with >500 ppm Sr content can be analysed with a precision of better than 100 ppm and a spatial resolution (spot size) of approximately 100 μm. The LA MC-ICPMS analysis of 87Sr/86Sr of both carbonate material and plagioclase is successful in all reported studies, although the higher 84Sr/86Sr ratios do suggest in some cases an influence of Ca dimer and/or argides. High Rb/Sr (>0.01) materials have been successfully analysed by carefully measuring the 85Rb/87Rb in standard material and by applying the standard-sample bracketing method for accurate Rb corrections. However, published LA-MC-ICPMS data on clinopyroxene, apatite and sphene records differences when compared with 87Sr/86Sr measured by thermal ionisation mass spectrometry (TIMS) and solution MC-ICPMS. This suggests that further studies are required to ensure that the most optimal correction methods are applied for all isobaric interferences.  相似文献   

2.
The determination of 93Zr concentration, a long-lived radionuclide present in spent nuclear fuel and in the structural components of nuclear reactors, is a major issue for nuclear waste disposal purpose and to validate neutronic calculation codes. To measure 93Zr concentration in irradiated cladding material with a high precision, an analytical method based on the use of multiple collector-inductively coupled plasma mass spectrometer (MC-ICPMS) combined to isotope dilution technique was developed. First a radiochemical separation of zirconium from a zircaloy sample (a zirconium alloy used as a cladding material for nuclear fuel elements), has allowed to obtain a very pure zirconium fraction with no potential isobaric interferences for mass spectrometric measurements. Then as the determination of all zirconium isotope ratios in the sample is necessary for the isotope dilution method, a MC-ICPMS procedure was developed to perform these precise measurements. Finally, the determination of 93Zr concentration in the same sample was performed, after preparation and calibration of a 96Zr spike solution. The uncertainties obtained on isotope ratios of zirconium by MC-ICPMS were in the order of 0.1%. The final uncertainty obtained on the 93Zr concentration in the nuclear material used and after chemical purification was lower than 0.6%.  相似文献   

3.
使用高浓缩同位素的^152Sm和^154Sm配制不同丰度的Sm基准溶液,对多接收电感耦合等离子体质谱(MC-ICPMS)的系统偏差进行校准,求出^154Sm/^152Sm的平均校准系数。采用指数函数式推算出其它同位素比的校准系数。对天然样品的测量结果进行校正,并与表面热电离质谱的测量结果进行了比较,主同位素对的丰度比误差小于0.03%。实验结果表明,MC-ICPMS测量的影响因素多,系统偏差较大,但是通过校正可以获得与表面热电离质谱一致的测量结果。通过实验,建立了MC-ICPMS的同位素丰度绝对测量方法。  相似文献   

4.
For isotope ratio applications where an internal isotope ratio precision >0.05–0.1% relative standard deviation suffices, single-collector inductively coupled plasma mass spectrometry (ICPMS) is fit-for-purpose, but for detecting more subtle variations in the natural isotopic composition of a target element, only multi-collector ICPMS (MC-ICPMS) can compete with thermal ionization mass spectrometry (TIMS). While as a result of the extensive sample preparation (analyte isolation) preceding TIMS and the "softer" ionization in vacuum, spectral interferences only seldom occur with this technique, their occurrence is recognized to be the most important drawback of ICPMS. This paper discusses high mass resolution and chemical resolution in a collision or dynamic reaction cell as powerful and versatile means to overcome spectral overlap and illustrates how their introduction has led to a substantial extension of the application range of ICPMS for isotope ratio applications. High mass resolution is the most elegant and straightforward way to overcome the problem of spectral overlap. Offering the possibility to operate the mass analyzer at a higher mass resolution, while at the same time preserving the flat-topped or trapezoidal peak shape required for highly precise isotope ratio measurements, was a challenge for the manufacturers of MC-ICPMS instrumentation. It will be discussed how these apparently contradicting requirements could be fulfilled simultaneously and an overview of the current situation will be given. Chemical resolution in a collision or dynamic reaction cell is an alternative to high mass resolution for overcoming spectral overlap. Real-life examples will be given to illustrate how also this approach can be used to advantage in isotope ratio work. Despite the greater flexibility and straightforwardness of high mass resolution, some situations will be discussed where chemical resolution is to be preferred. Finally, some desires as to future instrumentation are formulated.  相似文献   

5.
A long known way of anchoring isotope ratio values to the SI system is by means of gravimetrically prepared isotopic mixtures. Thermal ionization mass spectrometry (TIMS) is the traditionally associated measurement technique, but multi-collector double focusing inductively coupled plasma (MC-ICP)-MS now appears to be an attractive alternative. This absolute calibration strategy necessitates that mass discrimination effects remain invariant in time and across the range of isotope ratios measured. It is not the case with MC-ICPMS and the present work illustrates, in the case of Zn isotopic measurements carried out using locally produced synthetic Zn isotope mixtures (IRMM-007 series), how this calibration strategy must be adjusted. First, variation in mass discrimination effects across the measurement sequence is propagated as an uncertainty component. Second, linear proportionality during each individual measurement between normalized mass discrimination and the average mass of the isotope ratios is used to evaluate mass discrimination for the ratios involving low abundance isotopes. Third, linear proportionality between mass discrimination and the logarithm of the isotope ratio values for n(67Zn)/n(64Zn) and n(68Zn)/n(64Zn) in the mixtures is used iteratively to evaluate mass discrimination for the same ratios in the isotopically enriched materials. Fourth, ratios in natural-like materials (including IRMM-3702 and IRMM-651) are calibrated by external bracketing using the isotopic mixtures. The relative expanded uncertainty (k = 2) estimated for n(68Zn)/n(64Zn) and n(67Zn)/n(64Zn) ratio values in the synthetic isotopic mixtures and the natural-like zinc samples was in the range of 0.034 to 0.048%. The uncertainty on the weighing (0.01%, k = 1) was the largest contributor to these budgets. The agreement between these results and those obtained with a single detector TIMS and with another MC-ICPMS further validated this work. The absolute isotope ratio values found for IRMM-3702-material also proposed as "delta 0" for delta-scale isotopic measurements-are n(66Zn)/n(64Zn) = 0.56397 (30), n(67Zn)/n(64Zn) = 0.082166 (35), n(68Zn)/n(64Zn) = 0.37519 (16), and n(70Zn)/n(64Zn) = 0.012418 (23). The derived Zn atomic weight value Ar(Zn) = 65.37777 (22) differs significantly from the current IUPAC value by Chang et al. [1]. Remeasurement, with isotopic mixtures from the IRMM-007 series, of the Zn isotope ratios in the same Chang et al. [1] material have revealed large systematic differences (1.35 (27)% per atomic mass unit) that suggest unrecognized measurement biases in their results.  相似文献   

6.
In the nuclear domain, precise and accurate isotopic composition determination of elements in spent nuclear fuels is mandatory to validate neutron calculation codes and for nuclear waste disposal. The present study presents the results obtained on Cs isotope ratio by mass spectrometric measurements. Natural cesium is monoisotopic (133Cs) whereas cesium in spent fuels has 4 isotopes (133Cs, 134Cs, 135Cs, and 137Cs). As no standard reference material is available to evaluate the accuracy of Cs isotopic measurements, a comparison of cesium isotopic composition in spent nuclear fuels has been performed between Thermal Ionization Mass Spectrometry (TIMS) and a new method involving Multiple Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICPMS) measurements. For TIMS measurements, isotopic fractionation has been evaluated by studying the behavior of cesium isotope ratios (133Cs/137Cs and 135Cs/137Cs) during the analyses. For MC-ICPMS measurements, the mass bias effects have been corrected with an external mass bias correction using elements (Eu and Sb) close to cesium masses. The results obtained by the two techniques show good agreement: relative difference on 133Cs/137Cs and 135Cs/137Cs ratios for two nuclear samples, analyzed after chemical separation, ranges from 0.2% to 0.5% depending on the choice of reference value for mass bias correction by MC-ICPMS. Finally the quantification of the 135Cs/238U ratio by the isotope dilution technique is presented in the case of a MOx (mixed oxide) spent fuel sample. Evaluation of the global uncertainties shows that this ratio could be defined at an uncertainty of 0.5% (k = 2). The intercomparison between two independent mass spectrometric techniques is fundamental for the evaluation of uncertainty when no isotopic standard is available.  相似文献   

7.
8.
The precision of isotopic measurements of Pb by thermal ionization mass spectrometry (TIMS) is limited by the fact that this element does not possess an invariant isotope ratio that can be used for the correction of mass fractionation by internal normalization. Multiple-collector inductively coupled plasma mass spectrometry (MC-ICPMS) can overcome this limitation, because with plasma ionization, elements with overlapping mass ranges are thought to display identical mass discrimination. With respect to Pb, this can be exploited by the addition of Tl to the sample solutions; the mass discrimination factor obtained for Tl can then be used for the correction of the measured Pb isotope ratios. In this article we present the results of a detailed study that investigates the accuracy and precision of such an external correction technique for mass discrimination based upon the results of multiple analyses of a mixed standard solution of NIST SRM-981 Pb and SRM-997 Tl. Our data indicate that normalization of the Pb isotope ratios to the certified isotopic composition of SRM-997 Tl produces Pb isotopic results that are significantly lower than recently published reference values by TIMS. This systematic offset can be eliminated by renormalization of the Pb data to a different Tl isotopic composition to obtain an empirically determined mass discrimination factor for Pb that generates accurate results. It is furthermore shown that a linear law is least suited for the correction of mass discrimination, whereas a power or exponential law function provide significantly more accurate and precise results. In detail, it appears that a power law may provide the most appropriate correction procedure, because the corrected Pb isotope ratios display less residual correlations with mass discrimination compared to the exponentially corrected data. Using an exponential or power law correction our results, obtained over a period of over seven months, display a precision (2σ) of better than 60 parts per million (ppm) for 208Pb/206Pb and 207Pb/206Pb and of better than 350 ppm for 206Pb/204Pb, 207Pb/204Pb/204Pb, and 208Pb/204Pb. This represents a significant improvement compared to conventional TIMS techniques and demonstrates the potential of MC-ICPMS for routine, high-precision measurements of Pb isotopic compositions.  相似文献   

9.
Continuous developments in inorganic mass spectrometry techniques, including a combination of an inductively coupled plasma ion source and a magnetic sector-based mass spectrometer equipped with a multiple-collector array, have revolutionized the precision of isotope ratio measurements, and applications of inorganic mass spectrometry for biochemistry, geochemistry, and marine chemistry are beginning to appear on the horizon. Series of pioneering studies have revealed that natural stable isotope fractionations of many elements heavier than S (e.g., Fe, Cu, Zn, Sr, Ce, Nd, Mo, Cd, W, Tl, and U) are common on Earth, and it had been widely recognized that most physicochemical reactions or biochemical processes induce mass-dependent isotope fractionation. The variations in isotope ratios of the heavy elements can provide new insights into past and present biochemical and geochemical processes. To achieve this, the analytical community is actively solving problems such as spectral interference, mass discrimination drift, chemical separation and purification, and reduction of the contamination of analytes. This article describes data calibration and standardization protocols to allow interlaboratory comparisons or to maintain traceability of data, and basic principles of isotope fractionation in nature, together with high-selectivity and high-yield chemical separation and purification techniques for stable isotope studies.
Figure
Isotope ratios of the elements can vary through almost all the chemical and biochemical reactions in nature  相似文献   

10.
Symmetry-induced isotope effects in recombination and collision-induced dissociation reactions are discussed. Progress on understanding the anomalous isotope effects in ozone is reviewed. Then, calculations are performed for the simpler reaction xNe+yNe+H<-->xNeyNe+H, where x and y label either identical or different isotopes. The atomic masses in the model are chosen so that symmetry is the only difference between the systems. Starting from a single potential energy surface, the properties of the bound, quasibound, and continuum states of the neon dimer are calculated. Then, the vibration rotation infinite order sudden approximation is used to calculate cross sections for all possible inelastic and dissociative processes. A rate constant matrix that exactly satisfies detailed balance is constructed. It allows recombination to occur both via direct three-body collisions and via tunneling into the quasibound states of the energy transfer mechanism. The eigenvalue rate coefficients are determined. Significant isotope effects are clearly found, and their behavior depends on the pressure, temperature, and mechanism of the reaction. Both spin statistics and symmetry breaking produce isotope effects. Under most conditions the breaking of symmetry enhances the rates, but a wide spectrum of effects is observed; they range from isotope effects with a normal mass dependence to huge, mass-independent isotope effects to cancellation and even to reversal of the isotope effects. This is the first calculation of symmetry-induced isotope effects in recombination rates from first principles. The relevance of the present effects to ozone recombination is discussed.  相似文献   

11.
This critical review focuses on inductively coupled plasma mass spectrometry (ICP-MS) based applications for isotope abundance ratio measurements in various clinical samples relevant to monitoring occupational or environmental exposure, human provenancing and reconstruction of migration pathways as well as metabolic research. It starts with a brief overview of recent advances in ICP-MS instrumentation, followed by selected examples that cover the fields of accurate analyte quantification using isotope dilution, tracer studies in nutrition and toxicology, and areas relying upon natural or man-made variations in isotope abundance ratios (Pb, Sr, actinides and stable heavy elements). Finally, some suggestions on future developments in the field are provided.  相似文献   

12.
Since considerable time, isotopic analysis of different elements present in a sample, material or object (such as the ‘light’ elements H, C, N, O and S and ‘heavy’ elements, such as Sr and Pb), has been used in provenancing studies, as several factors — defined by “the environment” or origin of the sample — can lead to measurable differences in their isotopic composition. For the light elements, traditionally, (gas source) isotope ratio mass spectrometry (IR-MS) is used, while for a long period of time, thermal ionization mass spectrometry (TIMS) was considered as the only technique capable of detecting subtle variations in the isotopic composition of the ‘heavier’ elements. However, since the introduction of the first inductively coupled plasma mass spectrometers (ICP-MS), considerable attention has been devoted to the development of methodologies and strategies to perform isotopic analysis by means of ICP-MS. While the relatively modest isotope ratio precision offered by single-collector ICP-MS may already be fit-for-purpose under some circumstances, especially the introduction of multi-collector ICP-MS instruments, equipped with an array of Faraday detectors instead of a single electron multiplier, has lead to tremendous improvements in the field of isotopic analysis. As a result, MC-ICP-MS can be seen as a very strong competitor of TIMS nowadays, while it even provides information on the small isotopic variations shown by some elements, that are not or hardly accessible by means of TIMS (e.g., elements with a high ionization energy). Owing to these new instrumental developments, the application field of isotopic analysis by means of ICP-MS is continuously growing, also in the field of provenance determination. This paper is intended as a review of the developments in and the recent applications of isotopic analysis by means of ICP-MS in this specific research field.  相似文献   

13.
Reporting of variations in the natural isotopic composition of mercury   总被引:2,自引:0,他引:2  
High-precision measurements of natural variations in the stable isotopic composition of mercury show great promise as a new tracer of mercury sources and chemical transformations in the environment. We strongly suggest that all laboratories adopt a common means of data correction, standardization, and nomenclature in order to ensure that data from various laboratories can be easily evaluated and compared. We make suggestions for mass bias correction, reporting of mass-dependent and mass-independent isotope variations, and a standard protocol for reporting analytical uncertainties. We also present our measured values for isotope ratios in several mercury standard solutions.  相似文献   

14.
Ulfbeck D  Baker J  Waight T  Krogstad E 《Talanta》2003,59(2):365-373
A new method for rapid sample digestion and efficient chemical separation of Hf and REE from rock samples for precise isotopic analysis is presented. Samples are digested by fusion in the presence of a lithium borate flux at 1100 °C and dissolved whilst molten in dilute nitric or hydrochloric acid. Prior to chemical separation using ion exchange techniques, Li and B from the flux material and Si from the sample are separated from the remaining major elements, REE and high field strength elements (HFSE) in the sample by Fe-hydroxide co-precipitation. The chemical separation of Hf is a two-stage procedure designed to first remove the remaining matrix elements (e.g. Fe, Ba) in the sample using standard cation exchange techniques, followed by separation of Hf from the REE and HFSE on TEVA extraction chromatographic resin. Hf yields are >90% and total procedural blanks are ca. 50 pg. Hf isotope ratios of a synthetic standard solution and replicate digestions of international rock standards BHVO-1 and BCR-1 measured on multi-collector inductively coupled plasma mass spectrometer (MC-ICPMS) reproduce similarly to ≤50 ppm (2 S.D.). The following elemental ratios are routinely obtained for elements, which interfere isobarically or may affect the ionisation and/or fractionation behaviour of Hf during analysis: 176Yb/176Hf<0.0001; 176Lu/176Hf<0.00001; Ti/Hf<0.05. This technique also provides a means of separating Nd from the REE fraction for isotopic analysis and, potentially, may be adapted for measurement of Lu/Hf ratios by isotope dilution techniques.  相似文献   

15.
Results of Th isotope measurements on Harwell Uraninite (HU) solution aliquots and carbonates such as corals and speleothems using multi ion counter (MIC) procedures are presented. A multi ion counter array available for the ThermoFinnigan Neptune multi-collector inductively coupled plasma mass spectrometer (MC-ICPMS) is used for simultaneous measurements of 230Th and 229Th ion beams. A static collection of low-level ion beams improves the efficiency of isotope measurements which in turn reduces the required sample size and measurement time. The static measurement also circumvents problems with ion beam intensity fluctuations often observed with a plasma source. Instrumental bias corrections are based on a sample bracketing in-house Th standard solution. The accuracy and precision of the MIC array procedures for 230Th/229Th measurements are investigated by comparison to a MC-ICPMS peak jump procedure using just a single ion counting channel. The results show that similar precisions for 230Th/229Th measurements can be achieved using the MIC procedure with less than half total 230Th consumed compared to a peak jump routine. Thus, the MIC setup allows to use less than half the sample sizes for 230Th/U dating of carbonates compared to peak jump methods enabling higher spatial resolution sampling.  相似文献   

16.
A new, fast, continuous flow technique is described for the simultaneous determination of delta33S and delta34S using SO masses 48, 49 and 50. Analysis time is approximately 5 min/sample with measurement precision and accuracy better than +/-0.3 per thousand. This technique, which has been set up using IAEA Ag2S standards S-1, S-2 and S-3, allows for the fast determination of mass-dependent or mass-independent fractionation (MIF) effects in sulfide, organic sulfur samples and possibly sulfate. Small sample sizes can be analysed directly, without chemical pre-treatment. Robustness of the technique for natural versus artificial standards was demonstrated by analysis of a Canon Diablo troilite, which gave a delta33S of 0.04 per thousand and a delta34S of -0.06 per thousand compared to the values obtained for S-1 of 0.07 per thousand and -0.20 per thousand, respectively. Two pyrite samples from a banded-iron formation from the 3710 Ma Isua Greenstone Belt were analysed using this technique and yielded MIF (Delta33S of 2.45 and 3.31 per thousand) comparable to pyrite previously analysed by secondary ion probe.  相似文献   

17.
The study of Fe, Zn and Cd stable isotopes (δ56Fe, δ66Zn and δ114Cd) in seawater is a new field, which promises to elucidate the marine cycling of these bioactive trace metals. However, the analytical challenges posed by the low concentration of these metals in seawater has meant that previous studies have typically required large sample volumes, highly limiting data collection in the oceans. Here, we present the first simultaneous method for the determination of these three isotope systems in seawater, using Nobias PA-1 chelating resin to extract metals from seawater, purification by anion exchange chromatography, and analysis by double spike MC-ICPMS. This method is designed for use on only a single litre of seawater and has blanks of 0.3, 0.06 and <0.03 ng for Fe, Zn and Cd respectively, representing a 1–20 fold reduction in sample size and a 4–130 decrease in blank compared to previously reported methods. The procedure yields data with high precision for all three elements (typically 0.02–0.2‰; 1σ internal precision), allowing us to distinguish natural variability in the oceans, which spans 1–3‰ for all three isotope systems. Simultaneous extraction and purification of three metals makes this method ideal for high-resolution, large-scale endeavours such as the GEOTRACES program.  相似文献   

18.
The unique capabilities of multiple collector inductively coupled mass spectrometry (MC-ICP-MS) for high precision isotope ratio measurements in light elements as Li, Mg, Ca, and Cu are reviewed in this paper. These elements have been intensively studied at the Geological Survey of Israel (GSI) and other laboratories over the past few years, and the methods used to obtain high precision isotope analyses are discussed in detail. The scientific study of isotopic fractionation of these elements is significant for achieving a better understanding of geochemical and biochemical processes in nature and the environment.  相似文献   

19.
Gao B  Liu Y  Sun K  Liang X  Peng P  Sheng G  Fu J 《Analytica chimica acta》2008,612(1):114-120
A method for the accurate determination of Cd and Pb isotope compositions in sediment samples is presented. Separation of Cd and Pb was designed by using an anionic exchange chromatographic procedure. Measurements of Cd isotopic compositions were carried out by multi-collector inductively coupled plasma mass spectrometer (MC-ICPMS), by using standard-sample bracketing technology for mass bias correction and Pb isotopic ratios were determined by thermal ionization mass spectrometry (TIMS). The factors that affect the accurate and precise Cd isotope compositions analysis, such as instrumental mass fractionation and isobaric interferences, were carefully evaluated and corrected. The Cd isotopic results were reported relative to an internal Cd solution and expressed as the δ114/110Cd. Five Cd reference solutions and one Pb standard were repeatedly measured in order to assess the accuracy of the measurements. Uncertainties obtained were estimated to be lesser than 0.11‰ (2s) for the δ114/110Cd value. Analytical uncertainties in 2s for Pb isotopic ratios were better than 0.5‰. The method has been successfully applied to the investigation of Cd and Pb isotope compositions in sediment samples collected from North River in south China.  相似文献   

20.
Coprecipitation of nitrate and sulfate by barium has probably resulted in significant error in numerous studies dealing with the oxygen isotopic composition of natural sulfates using chemical/thermal conversion of BaSO(4) and analysis by isotope ratio mass spectrometry. In solutions where NO(3) (-)/SO(4) (2-) molar ratios are above 2 the amount of nitrate coprecipitated with BaSO(4) reaches a maximum of approximately 7% and decreases roughly linearly as the molar ratio decreases. The fraction of coprecipitated nitrate appears to increase with decreasing pH and is also affected by the nature of the cations in the precipitating solution. The size of the oxygen isotope artifact in sulfate depends both on the amount of coprecipitated nitrate and the delta(18)O and Delta(17)O values of the nitrate, both of which can be highly variable. The oxygen isotopic composition of sulfate extracted from atmospheric aerosols or rain waters are probably severely biased because photochemical nitrate is usually also present and it is highly enriched in (18)O (delta(18)O approximately 50-90 per thousand) and has a large mass-independent isotopic composition (Delta(17)O approximately 20-32 per thousand). The sulfate delta(18)O error can be 2-5 per thousand with Delta(17)O artifacts reaching as high as 4.0 per thousand. Copyright (c) 2008 John Wiley & Sons, Ltd.  相似文献   