首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
Quantitative determination of tertatolol concentrations in plasma and urine was performed by gas chromatography-mass spectrometry in the chemical-ionization mode with ammonia after successive extractions of the beta-blocking drug in alkaline, acid and final alkaline medium. [2H9]Tertatolol, isotopically stable under the operating conditions employed, was used as an internal standard, thus allowing quantities of 1 ng/ml to be specifically determined. Overall analytical error was less than 10%. Prior to isothermal chromatography at 240 degrees C on a column packed with 3% SE-30, both compounds were silylated with bis(trimethylsilyl)trifluoroacetamide. Detection was performed by monitoring the quasimolecular ions of tertatolol, m/z 368 and m/z 377, for the [2H9]tertatolol in the chemical-ionization mode with ammonia. The calibration curves obtained had linear characteristics for the concentration range 1-1125 ng/ml.  相似文献   

3.
A sensitive method for the determination of captopril in blood and urine by gas chromatography-mass spectrometry is described. In order to prevent oxidative degradation of captopril, its sulph-hydryl group was immediately protected by treatment with N-ethylmaleimide (NEM), and the resulting NEM adduct was then converted into the bis(pentafluorobenzyl) derivative. Derivatized captopril was separated on a 2% OV-1 column, exhibiting a single peak of the correct theoretical shape. The detection limit was estimated to be 100 pg by using S-benzylcaptopril as an internal standard. The blood level and urinary excretion of unchanged captopril orally administered to dogs were determined by the proposed method. In addition, epimerization of the proline moiety and formation of the sulphoxide or sulphone through the esterification step are also described.  相似文献   

4.
Lorazepam and oxazepam in plasma and urine were measured by gas chromatography-mass spectrometry. Oxazepam was used as an internal standard in the assay of lorazepam and vice versa. After removal of interfering substances with n-hexane, the drugs were extracted with benzene and converted to N1,O3-bistrimethylsilyl derivatives. Glucuronide forms of the drugs were extracted after hydrolysis with beta-glucuronidase. A common fragment ion at m/e 429 was used to monitor the two drugs. The sensitivity was 2 ng/ml for both drugs, which was sufficient to determine plasma and urine concentrations after therapeutic doses to humans.  相似文献   

5.
The dioxopiperazine metabolites of quinapril in plasma and urine were extracted with hexane-dichloroethane (1:1) under acidic conditions. Following derivatization with pentafluorobenzyl bromide and purification of the desired reaction products using a column packed with silica gel, the metabolites were analysed separately by capillary column gas chromatography-electron-impact mass spectrometry with selected-ion monitoring. The limits of quantitation for the metabolites were 0.2 ng/ml in plasma and 1 ng/ml in urine. The limits of detection were 0.1 ng/ml in plasma and 0.5 ng/ml in urine, at a single-to-noise ratio of greater than 3 and greater than 5, respectively. The proposed method is applicable to pharmacokinetic studies.  相似文献   

6.
Identification and quantitation of trace amounts of trenbolone in bovine tissue by capillary gas chromatography-mass spectrometry-selected-ion monitoring (GC-MS-SIM) has been developed. Three-phase liquid-liquid extraction using a mixture of water-acetonitrile-dichloromethane-hexane was utilized for the sample extraction from tissue. Target compounds were extracted from the tissue into the acetonitrile layer. The residue from this extraction was then subjected to solid-phase extraction by C18 and silica gel disposable cartridges using methanol-water and benzene-acetone as eluents. To overcome extensive matrix interferences, preparative reversed-phase high-performance liquid chromatographic separation was used with an octadecyl-bonded column using methanol-water as mobile phase for sample clean-up prior to GC-MS analysis. A structural analogue of trenbolone, 19-nortestosterone, was chosen as the internal standard for quantitation by GC-MS. The sample was co-injected with N,O-bis (trimethylsilyl) trifluoroacetamide-1-(trimethylsilyl) imidazole (95:5, v/v) for flash heater derivation. Identification and quantitation were simultaneously carried out by SIM of characteristic ions of the trimethylsilyl derivatives of trenbolone and 19-nortestosterone. The limit of detection for trenbolone and epitrenbolone was 0.5 ppb in muscle and liver tissue. A comparison of sensitivity and specificity between GC-MS under electron ionization in addition to positive- and negative-ion chemical ionization conditions using methane reagent gas is also discussed.  相似文献   

7.
8.
A sensitive and selective method for the determination of cotinine in plasma and urine is presented. Quantitation is effected by capillary gas chromatography-mass spectrometry after liquid--liquid extraction of 0.25-1 ml of biological specimens with a trideuterated cotinine internal standard. The procedure is linear and has acceptable precision over the range of concentrations encountered in pharmacokinetic studies of nicotine or cotinine. The suitability of the assay is shown by a number of plasma concentration--time curves after a single oral or intravenous administration of cotinine to a human volunteer and after multiple-dose intravenous administration of nicotine.  相似文献   

9.
气相色谱-质谱法同时快速测定血清中5种剧毒灭鼠剂   总被引:1,自引:0,他引:1  
黄会秋  黄逊  余惊笋 《色谱》2015,33(3):323-328
建立了同时快速测定血清样品中毒鼠强、氟乙酰胺、氟乙酸钠、甘氟Ⅰ与甘氟Ⅱ 5种灭鼠剂的气相色谱-质谱联用法。在pH 2.0条件下,以N,N-二乙基对苯二胺为衍生剂,N,N'-二环己基碳二亚胺为催化剂,氟乙酸钠在室温下振荡衍生5 min,衍生物与毒鼠强、氟乙酰胺、甘氟Ⅰ、甘氟Ⅱ一并被乙酸乙酯萃取,经50 ℃下氮吹浓缩后用气相色谱-质谱同时测定,采用选择离子监测(SIM)模式,基质标准外标法定量。方法选用SLB-IL59离子液体毛细管柱(30 m×0.25 mm×0.20 μm,最高温度:300 ℃),流速1.0 mL/min,经程序升温在15 min内成功地分离了5种灭鼠剂。结果显示,血清中氟乙酰胺的线性范围为0.02~2.0 mg/L,毒鼠强的线性范围为0.02~10 mg/L,其他目标物的线性范围为0.01~1.0 mg/L;检出限为0.001~0.002 mg/L (S/N=3),相关系数R2>0.995。在3个加标水平下,方法加标回收率介于84.0%和110.0%之间,相对标准偏差(n=6)介于2.9%和7.5%之间。方法操作简便、准确,灵敏度高,适于中毒病人的快速诊断检测。  相似文献   

10.
Buspirone and a buspirone metabolite, 1-(2-pyrimidinyl)piperazine (1-PP), are extracted from matrix using C18 extraction columns. The metabolite and its internal standard (d4-1-PP) are derivatized with pentafluorobenzoyl chloride to the corresponding amides. The 1-PP derivatives, buspirone and the buspirone internal standard (5-fluorobuspirone) are co-chromatographed. Chromatography and detection are performed using capillary gas chromatography with a fused-silica column and selected-ion monitoring-mass spectrometry. Linear range of the standard curves in plasma is 0.1-14 ng/ml for buspirone and 0.2-25 ng/ml for 1-PP with lower limits of quantitation of 0.1 and 0.2 ng/ml, respectively. In urine the linear range of the standard curves is 0.2-14 ng/ml for buspirone and 8-500 ng/ml for 1-PP with lower limits of quantitation of 0.2 and 8.0 ng/ml, respectively. Intra-assay accuracies were within 14% for buspirone and 1-PP in plasma and urine. Intra-assay precision was within 12% for both compounds in both matrices.  相似文献   

11.
Sildenafil analogues have been found adulterated in herbal preparations and food products that claim to have natural aphrodisiacs. In this study, a gas chromatography-mass spectrometry (GC-MS) assay was developed for the screening and identification of thioketone analogues of sildenafil. Thiopyrazolopyrimidine, a precursor or a cleavage product of thioketone analogue, exhibited characteristic fragment ions of m/z 328 and m/z 299 was found to be the best marker to screen the presence of general thioketone analogues. Identification by GC-MS assay was rapid and specific as all the studied thioketones showed characteristic mass fragmentations including their intact molecular ions. The developed GC-MS assay had successfully identified thiosildenafil, thiohomosildenafil and thiodimethylsildenafil in herbal preparation and food products.  相似文献   

12.
This paper deals with the different GC-MS analytical conditions adopted by four laboratories in an attempt to confirm the accuracy of the GC-electron-capture detection (ECD) analytical results during the international collaborative study for the establishment of the AOAC Official Method 998. 01. What is especially noted is that two laboratories have conducted comparative analysis of the respective 12 blind samples with both methods of GC-ECD and GC-MS, and the analytical results of the two methods turn out to be basically identical. This fully demonstrates that GC-MS is not only an effective confirmation tool in the analysis of the pyrethroid residues but also of sufficient sensitivity regarding the maximum residue limit of determination prescribed by FAO/WHO. Moreover, its selectivity is better than GC-ECD.  相似文献   

13.
14.
A novel method has been developed to simultaneously determine and quantify seven organic UV filters employing liquid (solid)-liquid extraction, derivatization with N-methyl-N-(trimethylsilyl) trifluoroacetamide (MSTFA) and gas chromatography with mass spectrometric detection in various environmental matrices. The UV filters determined were: benzophenone (BP), benzhydrol (BH), 4-hydroxybenzophenone (HBP), 2-hydroxy-4-methoxybenzophenone (HMB), 2,4-dihydroxybenzophenone (DHB), 2,2'-dihydroxy-4-methoxybenzophenone (DHMB) and 2,3,4-trihydroxylbenzophenone (THB). Under optimal conditions, the analysis required 23 min and good linearity over the range of 10-2,500 ng/L in water and 100-25,000 ng/kg in soil for each UV filter obtained. The high recovery (62-114% and 60-125% for water and soil samples, respectively) and the low RSD values (less than 13.9 and 17.2% for water and soil samples, respectively) indicated the high performance of this method. The method detection limits (MDLs) were relatively low, ranging from 5 to 100 ng/L or kg and quantification limits ranged between 25 and 500 ng/L or kg for all test compounds. This validated method was applied in the analysis of seven BP-type UV filters collecting water and soil samples in Korea, between April and May 2003. The overall concentration of UV filters in the soil sample (500-18,380 ng/kg) was highly distributed in water sample (27-204 ng/L). The established method was successfully applied to monitor the residue measurement of the BP-type UV filters in environmental water and soil samples.  相似文献   

15.
An efficient and sensitive method for simultaneous determination of 118 pesticide residues in teas has been established and validated. A multi-residue analysis of pesticides in tea involved extraction with ethyl acetate-hexane, clean-up using gel permeation chromatography (GPC) and solidphase extraction (SPE), and subsequent identification and quantification of the selected pesticides by gas chromatography-mass spectrometry (GC-MS). For most of the target analytes, optimized pretreatment processes led to no significant interference with analysis of sample matrix, and the determination of 118 compounds was achieved in about 60 min. In the linear range of each pesticide, the correlation coefficient was R 2 ≥ 0.99. At the low, medium and high three fortification levels of 0.05–2.5 mg kg−1, 118 pesticides average recoveries range from 61 % to 121 % and relative standard deviations (RSD) were in the range of 0.6–9.2 % for all analytes. The limits of detection for the method were 0.00030-0.36 mg kg−1, depending on each pesticide.  相似文献   

16.
The gas chromatography/mass spectrometric assay method was developed for the determination of 13 non‐steroidal anti‐inflammatory drugs (NSAIDs) in river water. Extraction was achieved by a liquid‐phase extraction procedure using methylene chloride. The extract was reacted for 30 min at 80°C based on the formation of methyl ester with 1.0 M HCl in methanol and extraction of the derivative with ethyl acetate, which was then measured by gas chromatography‐mass spectrometry. The limit of quantification of NSAIDs was 1.0–60 ng/L and the calibration curve showed linearity being greater than r=0.997. The method was used to analyze ten river water samples from various regions in Korea. Diclofenac, indoprofen, ketoprofen and loxoprofen were detected at concentration of up to 1.29 μg/L in river water. The developed method may prove valuable for use in the national monitoring project of NSAIDs in surface water.  相似文献   

17.
A simple and effective method has been developed to simultaneously determine endocrine-disrupting phenolic xenoestrogens and steroid estrogens in sediment by using ultra-sonicated extraction in combination with silica gel fractionation, derivatization with pentafluropropionic anhydride, and gas chromatography-mass spectrometry (GC-MS) in selected ion monitoring mode (SIM). Satisfactory recoveries have been obtained for phenolic xenoestrogens and steroid estrogens. The method enables the determination of targets at concentrations of lower nanogram-per-gram in sediments. The method has been successfully applied to the sediments collected from Pearl River Estuary (PRE), South China Sea, China. Nonylphenol and bisphenol-A (BPA) were detected in the range from 204.2 to 664.5 ng/g and 0.6 to 4.0 ng/g, respectively. None of the estrogens were found in the sediment samples.  相似文献   

18.
A capillary column gas chromatography--mass fragmentographic method for metapramine and its three major demethylated metabolites is described. Compounds are extracted from plasma using a double-extraction procedure and transformed into N-trifluoroacetyl derivatives. The detection is performed by monitoring specific ions for metapramine and for its metabolites with a mass detector. In spite of extensive metabolism in the liver and rapid elimination of metapramine, plasma concentrations of both metapramine and its metabolites can be simultaneously followed over 24 h after a single 150-mg oral dose, because of the sensitivity and selectivity of the method. This method has been successfully applied to the analysis of samples obtained from patients who were at steady state with metapramine and to a pharmacokinetic study in a healthy volunteer.  相似文献   

19.
We developed a liquid chromatography/electrospray ionization tandem mass spectrometry method for the simultaneous quantitative determination of C18 sphingosine (Sph), C18 dihydrosphingosine (dhSph), C18 phytosphingosine (pSph), C18 sphingosine-1-phosphate (S1P), C18 dihydrosphingosine-1-phosphate (dhS1P), and C18 phytosphingosine-1-phosphate (pS1P). Samples were prepared by simple methanol deproteinization and analyzed in selected reaction monitoring modes. No peak tailing was observed on the chromatograms using a Capcell Pak ACR column (1.5 mm i.d. × 250 mm, 3 μm, Shiseido). The calibration curves of the sphingoids showed good linearity (r > 0.996) over the range of 0.050-5.00 pmol per injection. The accuracy and precision of this method were demonstrated using four representative biological samples (serum, brain, liver, and spleen) from mice that contained known amounts of the sphingoids. Samples of mice tissue such as plasma, brain, eye, testis, liver, kidney, lung, spleen, lymph node, and thymus were examined for their Sph, dhSph, pSph, S1P, dhS1P, and pS1P composition. The results confirmed the usefulness of this method for the physiological and pathological analysis of the composition of important sphingoids.  相似文献   

20.
曾凯  刘峙嵘  宁雅君  李金林  唐俊  张敏 《色谱》2013,31(5):477-480
建立了同时测定乳制品中三聚氰胺及肌酐的气相色谱-质谱联用方法。样品经1%三氯乙酸溶液萃取,混合型阳离子交换固相萃取净化,提取液用氮气吹干后加入N,O-双(三甲基硅基)三氟乙酰胺-三甲基氯硅烷(BSTFA-TMCS)硅烷化试剂,于75 ℃下衍生60 min,最后采用选择离子模式下的气相色谱-质谱测定。三聚氰胺和肌酐的定量限分别为0.10 mg/kg和0.20 mg/kg;在0.1~50 mg/L范围内的线性相关系数均大于0.99。实际样品中,肌酐在10~100 mg/kg和三聚氰胺在0.1~5.0 mg/kg添加范围内的回收率分别为80.7%~116.8%和77.6%~107.5%,相对标准偏差分别小于9.4%和8.5%。该方法能有效除去干扰,灵敏度高,回收率较好,可用于乳制品中三聚氰胺和肌酐的同时测定。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号