首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Melin V  Perrett D 《Electrophoresis》2004,25(10-11):1503-1510
Separations of human urine by microemulsion electrokinetic chromatography (MEEKC) and micellar electrokinetic capillary chromatography (MEKC) with respect to resolution, migration times and efficiencies were optimized and compared. The optimised MEEKC and MEKC methods were simple and fast, both of which are excellent characteristics for the complex separations required in clinical and biomedical studies. However, resolution in MEKC was significantly greater than in MEEKC although migration times were 30% faster for the optimised MEEKC method. In addition, a faster analysis method (short-end injection) specifically for routine screening purposes was also investigated. With both MEEKC and MEKC modes, this provided short separations (less than 4 min for urine) with no major compromise in resolution. In conclusion, we found that MEEKC offered no real advantage over MEKC for urine analysis.  相似文献   

2.
In this study, separation and determination of nine preservatives ranging from hydrophilic to hydrophobic properties, which are commonly used as additives in various pharmaceutical and cosmetic products, by micellar electrokinetic chromatograpy (MEKC) and microemulsion electrokinetic chromatography (MEEKC) were compared. The effect of temperature, buffer pH, and concentration of surfactant on separation were examined. In MEKC, the separation resolution of preservatives improved markedly by changing the sodium dodecyl sulfate concentration. Temperature and pH of running buffers were used mainly to shorten the magnitude of separation time. However, in order to detect all preservatives in a single run in a MEEKC system, a microemulsion of higher pH was needed. The separation resolution was improved dramatically by changing temperature, and a higher concentration of SDS was necessary for maintaining a stable microemulsion solution, therefore the separation of the nine preservatives in MEEKC took longer than in MEKC. An optimum MEKC method for separation of the nine preservatives was obtained within 9.0 min with a running buffer of pH 9.0 containing 20 mM SDS at 25 degrees C. A separation with baseline resolution was also obtained within 16 min using a microemulsion of pH 9.5 which composed of SDS, 1-butanol, and octane, and a shorter capillary column at 34 degrees C. Finally, the developed MEKC and MEEKC methods determined successfully preservatives in various cosmetic and pharmaceutical products.  相似文献   

3.
考察了用微乳液毛细管电动色谱(MEEKC)分离蛋白质时微乳液组成等不同因素对分离的影响,并与胶束电动色谱进行对比,探讨了其分离机理,为蛋白质的分离鉴定提供了一种有力的工具.  相似文献   

4.
Microemulsion EKC (MEEKC) was developed for quantitative analysis of curcuminoids, such as curcumin (C), demethoxycurcumin (D), and bis-demethoxycurcumin (B). MEEKC separation of curcuminoids was optimized, and a change in resolution was explained using a modified equation for resolution in MEEKC without electroosmosis. The suitable MEEKC conditions for separation of curcuminoids were obtained to be the microemulsion buffer containing 50 mM phosphate buffer at pH 2.5, 1.1% v/v n-octane as oil droplets, 180 mM SDS as surfactant, 890 mM 1-butanol as cosurfactant, and 25% v/v 2-propanol as organic cosolvent; applied voltage of -15 kV; and separation temperature 25 degrees C. Achieved baseline resolution of C:D and D:B was obtained with R(s) -2.4 and analysis time within 18 min. In addition, high accuracy and precision of the method were obtained. This MEEKC method was used for quantitative determination of individual curcuminoids in medicinal turmeric capsules and powdered turmeric used as coloring additive in food, with simple sample preparation such as solvent extraction, dilution, and filtration, and without cleaning up by SPE.  相似文献   

5.
Huang HY  Lien WC  Huang IY 《Electrophoresis》2006,27(16):3202-3209
In this study, anion-selective exhaustive injection-sweeping (ASEI-sweeping) technique, which is a selective on-line sample concentration technique, was first proposed in microemulsion electrokinetic chromatography (MEEKC) for analyses of eight acidic phenolic compounds. In contrast to a capillary that is typically filled with nonmicellar background solution in conventional ASEI-sweeping MEKC method, in the proposed ASEI-sweeping MEEKC method, a capillary is filled with a low pH microemulsion solution (pH 2.0), and then with a short acid plug (pH 2.0, 1.9 cm) before field-amplified sample injection. This proposed design has two functions. First, the microemulsion solution that is present at the front of capillary column is able to avoid phase separation of microemulsion solution during MEEKC separation. Second, the presence of the short acid plug would effectively limit the partition behavior of acid analytes with the oil droplets in the microemulsion during field-amplified sample injection; otherwise, the stacking effect of acid analytes would be markedly reduced. This optimal ASEI-sweeping MEEKC method afforded about 96,000-fold to 238,000-fold increases in detection sensitivity in terms of peak areas without any separation efficiency loss when compared to normal MEEKC separation. Furthermore, trace levels (about 3 ng/g) of gallic acid and catechin in foods were also detected successfully by the proposed ASEI-sweeping MEEKC technique.  相似文献   

6.
Microemulsion electrokinetic chromatography (MEEKC) has been widely used as an indirect tool to measure octanol–water partition coefficients (logP ow) of various kinds of compounds. In this paper, we present for the first time a mathematical model of the precision of logP ow (ΔlogP ow) as a function of the deviation of migration time (Δt m) in MEEKC, and more importantly evaluated the accuracy of the MEEKC. Our model shows that for a given microemulsion system, there is an interval of migration times, where a high precision in the determination of logP ow can be obtained. However, when the migration time approaches either the migration time of the electroosmotic flow or that of the microemulsion phase, the precision of logP ow deteriorates rapidly. The model was experimentally verified by the microemulsion system with migration times of 6.50 and 32.00?min for the electroosmotic flow and microemulsion phase, respectively, and we found the useful logP ow interval to be 0.50–5.50. The paper also demonstrates that the calibration constants between migration times t m and predicted logP ow values could be transferred with high accuracy from one MEEKC system to another as long as both systems are set up to use the same operational parameters.  相似文献   

7.
Based on the investigation of the effect of microemulsion charge on the chiral separation, a new chiral separation method with MEEKC employing neutral microemulsion was established. The method used a microemulsion containing 3.0% (w/v) neutral surfactant Tween 20 and 0.8% (w/v, 30 mM) dibutyl l ‐tartrate in 40 mM sodium tetraborate buffer to separate the enantiomers of β‐blockers. The effect of major parameters on the chiral separation was investigated. The applied voltage had little effect on the resolution, but the chiral separation could be improved by suppressing the EOF. Nine racemic β‐blockers obtained relatively good enantioseparation after appropriate concentrations of tetradecyl trimethyl ammonium bromide were added into the microemulsion to suppress the EOF. These results were explained based on the analysis of the separation mechanism of the method and deduced separation equations. The resolution equation of the method was further elucidated. It was found that the fourth term in the resolution equation, an additional term compared to the conventional resolution equation for column chromatography, represents the ratio of the relative movement distance between the analyte and microemulsion droplets relative to the effective capillary length. It can be regarded as a correction for the effective capillary length. These findings are significant for the development of the theory of MEEKC and the development of new chiral MEEKC method.  相似文献   

8.
The resolution (R(s)) of hydrophobic analytes in microemulsion EKC (MEEKC) and MEKC with suppressed electroosmosis was investigated using bisphenol-A-diglycidyl ether and its derivatives (BADGEs) as test analytes. Separation scales were compared using our equation for the resolution, R(s)= (square rootN/4)(alpha-1)/(1+K(2)),where k is the retention factor, alpha the selectivity (alpha = k(2)/k(1) for k(2) > or = k(1)>0), and N the average efficiency. At given concentrations of SDS and organic cosolvent in the buffer, in comparison with MEKC, MEEKC was found to provide better resolution of BADGEs, mainly due to the significantly smaller k in MEEKC, but not the greater alpha in MEEKC, while a comparable range of N. Significantly improved resolution of BADGEs was obtained with increase in the concentration of organic cosolvent in the MEEKC and MEKC buffers, while small change in R(s) with the SDS concentration in a range of 100-180 mM. In addition, a decrease in temperature or voltage resulted in slightly better R(s).  相似文献   

9.
A novel microemulsion based on sodium bis(2-ethylhexyl) sulfosuccinate (AOT) was developed for the simultaneous determination of natural and synthetic estrogens by microemulsion EKC (MEEKC). The microemulsion system consisted of 1.4% w/w AOT, 1.0% w/w octane, 7.0% w/w 1-butanol and 90.6% w/w 20 mM sodium salt of 3-(cyclohexylamino)-2-hydroxy-1-propanesulfonic acid (CAPSO) and 10 mM phosphate buffer at pH 12.5. A baseline resolution in the separation of estrone, 17beta-estradiol, estriol, estradiol 17-hemisuccinate, etinilestradiol, estradiol 3-benzoate, and estradiol 17-valerate was achieved in comparison to the traditional MEEKC system with SDS in less than 15 min. The optimized electrophoretic conditions included the use of an uncoated-silica capillary of 60 cm of total length and 75 microm id, an applied voltage of 25 kV, a temperature of 25 degrees C and 214 UV-detection. Parameters of validation such as specificity, linearity, accuracy, LOD, LOQ and robustness were evaluated according to international guidelines. Due to its simplicity, accuracy, and reliability, the proposed method can be an advantageous alternative to the traditional methodologies for the analysis of natural and synthetic estrogens in different pharmaceutical forms.  相似文献   

10.
A new hexane-in-water microemulsion was investigated as buffer in microemulsion EKC (MEEKC). At difference with other microemulsions, the addition of cosurfactant was not necessary to stabilize the microemulsion. The proposed microemulsion was successfully used to achieve electrophoretic separation of seven antibiotics including nitroimidazoles, cephapirin and tetracyclines. Selectivity and separation efficiency achieved in MEEKC were compared with MEKC. MEEKC technique proved to be more efficient than MEKC for performing the separation of the analytes and the presence of microemulsions was found to be critical to achieve the separation of tetracyclines. The proposed microemulsion also points out that solvents with high volatility, such as hexane, can be stabilized and used as a microemulsion of SDS.  相似文献   

11.
Microemulsion EKC (MEEKC) was used for the determination of ketorolac and its three impurities. The microemulsion system was optimized, for the first time in the literature, using a multivariate strategy involving a mixture design. A 13-run experimental plan covering an experimental domain defined by the components aqueous phase (10 mM borate buffer pH 9.2), oil phase (n-heptane) and surfactant/cosurfactant (SDS/n-butanol) was carried out. Good results were obtained with all microemulsions tested considering as responses analysis time and resolution, and according to the desirability function the best microemulsion system was constituted by 90.0% 10 mM borate buffer, 2.0% n-heptane, 8.0% of SDS/n-butanol in 1:2 ratio. Finally, with the aim of reducing analysis time, a response surface study was carried out in the experimental domain defined by the process variables temperature and voltage and the best values were 17 degrees C and -17 kV, respectively. Applying the optimised conditions, a complete resolution among the analytes was obtained in about 3 min using the short-end injection method. The method was validated for both drug substances and drug product and was applied to the quality control of ketorolac in coated tablets. A comparison of MEEKC, MEKC and CEC for assaying ketorolac and its related substances has been made.  相似文献   

12.
Microemulsion electrokinetic chromatography (MEEKC) has been applied to the separation of some phenolic antioxidants [Irganox 1024, Irganox 1035, Irganox 1076, Irganox 1010, Irganox 1330, Irgafos 138, Irganox 168 and 2,6-di-tert.-butyl-4-methylphenol (BHT)]. Due to the extremely hydrophobic nature of these analytes, they could not be separated using standard MEEKC conditions and two alternative approaches were investigated. Using an acidic buffer (phosphate, pH 2.5) to effectively suppress the electroosmotic flow, the addition of 2-propanol to the aqueous phase of the microemulsion buffer to improve partitioning of the analytes, and a negative separation voltage, separation of five of the analytes in under 10 min was possible. The second approach, using a basic buffer (borate, pH 9.2) and a positive separation voltage resulted in complete resolution of all eight analytes. A mixed surfactant system comprising the anionic sodium dodecyl sulfate (SDS) and neutral Brij 35 was used to reduce the overall charge and with it the mobility of the droplets, and hence the separation time. Using an optimised MEEKC buffer consisting of 2.25% (w/w) SDS, 0.75% (w/w) Brij 35, 0.8% (w/w) n-octane, 6.6% (w/w) 1-butanol, 25% (w/w) 2-propanol and 64.6% (w/w) 10 mM borate buffer (pH 9.2) the eight target analytes were baseline separated in under 25 min. For these analytes, MEEKC was found to be superior to micellar electrokinetic chromatography in every respect. Specifically, the solubility of the analytes was better, the selectivity was more favourable, the analysis time was shorter and the separation efficiency was up to 72% higher when using the MEEKC method. Detection limits from 5.4 to 26 microg/ml were obtained and the calibration plot was linear over more than one order of magnitude. The optimised method could be applied to the determination of Irganox 1330 and Irganox 1010 in polypropylene.  相似文献   

13.
Zhang Y  Li Q  Lu M  Zhang L  Chen G  Cai Z 《色谱》2011,29(8):791-797
建立了一种微乳液毛细管电动色谱(MEEKC)-场放大富集(FASI)分析尿液中多种麻醉剂(吗啡、可待因、纳洛酮、海洛因、蒂巴因、可卡因、哌替啶、芬太尼、美沙酮)的方法。考察了微乳液组成、分离电压等因素的影响,得到的最佳微乳液组成(质量分数)为0.6%十二烷基硫酸钠、1.2%正丁醇、0.6%乙酸乙酯和97.6% 10 mmol/L硼砂缓冲液(pH 9.5);分离电压为25 kV。在上述微乳体系中,9种化合物在15 min内得到了基线分离。采用场放大在线富集技术提高了分析灵敏度,检出限(S/N=3)低至0.3 μg/L。模拟尿样样品中9种麻醉剂的加标回收率介于79.4%~119.9%之间,日内相对标准偏差小于5.5%。将该方法应用于美沙酮大鼠体外代谢样品的测定,结果令人满意。  相似文献   

14.
Recent advances in the development and application of microemulsion EKC   总被引:1,自引:0,他引:1  
Microemulsion EKC (MEEKC) is an electrodriven separation technique. Separations are typically achieved using oil-in-water microemulsions, which are composed of nanometre-sized oil droplets suspended in an aqueous buffer. The droplets are stabilised by a surfactant and a cosurfactant. The novel use of water-in-oil microemulsions has also been investigated. This review summarises the advances in the development of MEEKC separations and also the different areas of application including determination of log P values, pharmaceutical applications, chiral analysis, natural products and bioanalytical separations and the use of new methods such as multiplexed MEEKC and high speed MEEKC. Recent applications (2004-2006) are tabulated for each area with microemulsion composition details.  相似文献   

15.
Microemulsion electrokinetic chromatography (MEEKC) was developed for quantitative analysis of avermectins, such as abamectin, doramectin and ivermectin, in commercial formulations, using the microemulsion buffer containing a 50 mM phosphate buffer at pH 2.5, 1.1% (v/v) n-octane as oil droplets, 180 mM sodium dodecylsulphate as surfactant, 890 mM 1-butanol as co-surfactant and 30% (v/v) ethanol as organic co-solvent. High accuracy and precision of the method were obtained. The contents of avermectins in commercial formulations determined by MEEKC were found to be insignificantly different with those determined by high performance liquid chromatography (HPLC). Therefore, MEEKC can be used an alternative method to HPLC for quantitative determination of avermectins.  相似文献   

16.
Yang X  Xia Y  Tao C  Liao Y  Zuo Y  Liu H 《Electrophoresis》2007,28(11):1744-1751
An investigation of the basic factors which govern the microemulsion EKC (MEEKC) and MEKC for the separation of four benzoylurea (BU) insecticides and their four analogs was carried out. In MEEKC, the separation of eight BU compounds was optimized by changing the microemulsion composition, such as concentration of SDS, octane, n-butanol, and isopropanol percentages, as well as capillary temperature. Separation optimization was also carried out for MEKC, showing that ACN and a high level of another additive gamma-CD were needed to achieve effective separation of these analytes. Although separation with baseline resolution was achieved by either MEEKC or MEKC methods, the separation selectivity resulting from the proposed MEEKC method was completely different from that of MEKC. In addition, analytical time in MEEKC was longer than that in MEKC, but in view of theoretical plate numbers, detection limits, and reproducibility, both methods were effective for the analysis of BU insecticides and their analogs.  相似文献   

17.
微乳液毛细管电动色谱研究   总被引:2,自引:0,他引:2  
傅小芸  吕建德  竺安 《化学学报》1997,55(5):503-507
本文研究了两组混合样的微乳液毛细管电动色谱(MEEKC)分离, 较系统地研究了微乳液的内相, 助表面活性剂及其浓度对电动分离的迁移时间、柱效及时间窗的影响, 并与胶束毛细管电动色谱(MEKC)分离进行了比较, 选用由80mmol/L正辛烷-120mmol/L十二烷基硫酸钠-900mmol/L正丁醇-10mmol/L硼砂组成的微乳液, 样品组分电动色谱迁移时间的RSD<0.8%, 峰面积RSD<3.0%.  相似文献   

18.
A rapid screening assay for the determination of octanol-water partition coefficients (log P(OW)) of pharmaceuticals was developed by using pressure-assisted microemulsion electrokinetic chromatography (MEEKC). The microemulsion system contains 50 mM sodium dodecyl sulfate, 0.87 M l-butanol, 82 mM heptane, and 50 mM borate-phosphate (2:3) at pH 10. Ten standard compounds with known log P(OW) values from -0.26 to 4.88 were used for constructing the calibration curve of log P(OW) against the MEEKC retention factor, log k. The log P(OW) values of the compounds were calculated based on the log k values measured by MEEKC and the slope and intercept of the calibration curve. For 13 literature and 32 Roche compounds, about 90% of the log P(OW) values measured by MEEKC are within 0.5 log units of the values from the literature and potentiometric titration. The throughput is about 2 samples/h using +20 kV voltage plus 5 mbar air pressure for separation. This MEEKC method is applicable for log P(OW) screening of weakly basic, weakly acidic, and neutral pharmaceuticals with log P(OW) = 0-5 and pKa < or = 10.  相似文献   

19.
Mertzman MD  Foley JP 《Electrophoresis》2004,25(9):1188-1200
Cyclodextrin (CD)-modified microemulsion electrokinetic chromatography (MEEKC) or CD-MEEKC has not previously been applied to the area of chiral separations. Herein, the results of investigations of various microemulsions with CD additives are presented. Two different microemulsions are explored: an ethyl acetate sodium dodecyl sulfate microemulsion, and a chiral dodecoxycarbonylvaline (DDCV) microemulsion. Each microemulsion is paired separately with a neutral CD (hydroxypropyl-beta-CD) and an anionic CD (sulfated-beta-CD). In addition, the chiral DDCV microemulsion is investigated in both the R- and S- form. By varying simple parameters such as buffer system, applied voltage, surfactant enantiomer, and type of cyclodextrin, dramatic improvements in the chiral separations were noted. Resolution was found to be highly dependent on buffer identity and concentration, and somewhat dependent on whether the CDs used were randomly or highly sulfated. Under optimized conditions, the resolution ranged from 0.8 to 4.8, with plate counts ranging from 4000 to 26 000. Additionally, S- and R-levetiracetam, which had never before been enantioseparated via capillary electrophoresis (CE) methodologies, were separated in less than 8 min, with a resolution of 1.1.  相似文献   

20.
A microemulsion electrokinetic chromatography (MEEKC) method was developed to analyze and detect eight food colorants (tartrazine, fast green FCF, brilliant blue FCF, allura red AC, indigo carmine, sunset yellow FCF, new coccine, and carminic acid), which are commonly used as food additives in various food products. The effects of sodium dodecyl sulfate (SDS) surfactant, organic modifier, cosurfactant, and oil were examined in order to optimize the separation. The amount of organic modifier (acetonitrile) and SDS surfactant were determined as apparent influences on the separation resolution while the type of oil and cosurfactant rarely affected the separation selectivity of the eight colorants. A highly efficient MEEKC separation method, where the eight colorants were separated with baseline resolution within 14 min, was achieved by using a microemulsion solution of pH 2.0 containing 3.31% SDS, 0.81% octane, 6.61% 1-butanol, and 10% acetonitrile. This optimal MEEKC method has a higher separation efficiency and similar detection limit when compared to conventional capillary electrophoresis (CE) method. Furthermore, a sample pretreatment is rarely needed when this MEEKC technique is used to analyze colorants in food products, whereas a suitable sample pretreatment (for example solid-phase extraction) has to be employed prior to CE separation in order to eliminate matrix interferences resulting from the constituents of the food sample.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号