首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
A simple and rapid method for the highly sensitive determination of polycyclic aromatic hydrocarbons (PAHs) in water was developed. Benzo[a]pyrene, benzo[k]fluoranthene, perylene, and pyrene in water were concentrated into sodium dodecyl sulfate (SDS)-alumina admicelles. The collection was performed by adding SDS and alumina particles into the sample solution at pH 2. After gentle mixing, the resulting suspension was passed through a membrane filter to collect the SDS admicelles containing highly concentrated PAHs. The filter was placed on a slide glass and then covered admicellar layer with a fused silica glass plate before setting in a fluorescence spectrometer. Benzo[a]pyrene, benzo[k]fluoranthene, perylene, and pyrene were selectively determined by the synchronous fluorescence scan (SFS) analysis with keeping wavelength intervals between excitation and emission to 98, 35, 29, and 45 nm, respectively. Because of the minimum spectral overlapping, 1-40 ng l−1 of benzo[a]pyrene, benzo[k]fluoranthene, and perylene as well as 10-150 ng l−1 of pyrene were selectively determined with eliminating the interferences of other 12 PAHs. The detection limits were 0.3 ng l−1 for benzo[a]pyrene, benzo[k]fluoranthene, and perylene, and 1 ng l−1 for pyrene. They were 2-3 orders of magnitude lower than the detection limits in normal aqueous micellar solutions. The application to water analysis was studied.  相似文献   

2.
A simple and rapid microwave-assisted extraction (MAE) procedure was developed and optimized for benzo[a]anthracene, benzo[e]pyrene, benzo[b]fluoranthene, benzo[k]fluoranthene and benzo[a]pyrene in wood samples. The spiked wood used was prepared 3 months before analysis to simulate weathering processes and to allow the formation of analyte-matrix interaction. The samples, immersed in acetonitrile were irradiated with microwaves in a closed-vessel system. Optimization of the method was achieved by using a factorial design approach on parameters such as extraction time, temperature and sample amount. The analysis of extracts has been carried out by reversed-phase high-performance liquid chromatography with fluorescence detection for quantification and UV-diode-array detection for confirmation. The MAE procedure yielded extracts that could be analyzed directly without any preliminary clean-up or solvent exchange steps.  相似文献   

3.
《Analytical letters》2012,45(11):1293-1306
Abstract

The amounts of five polynuclear aromatic hydrocarbons-fluoranthene, pyrene, benzo(a)anthracene, benzo(k)fluoranthene, and benzo(a)pyrene-extracted by six solvents with four extraction techniques have been determined for diesel exhaust particulate collected on Teflon-coated glass fiber filters. Samples were analyzed by high pressure liquid chromatography with fluorescence detection. Toluene and methylene chloride gave higher recoveries than methanol, isopropanol, acetonitrile, and acetone for benzo(a)anthracene, benzo(k)fluoranthene, and benzo(a)pyrene. Soxhlet extraction for two hours (approximately 48 cycles) with toluene or acetonitrile was more effective than simple mechanical agitation, ultrasonic agitation for 15 minutes or immersion in refluxing ‘solvent’ for two hours.  相似文献   

4.
An extraction/clean-up procedure by SFE was developed for isolating PAHs from liver samples for subsequent HPLC-FL determination of ten PAHs in the enriched extract. Recoveries (90-115%) and RSD % (< or =7.7) were satisfactory. When applied to 11 samples of bird of prey (Tyto alba) protected species and classified of special interest, from the Galicia (Northwest to Spain), benzo[ghi]perylene and indeno[1,2,3-cd]pyrene were undetectable; chrysene and benzo[a]pyrene are only detected in one sample; benzo[a]anthracene and benzo[k]fluoranthene are only quantified in one sample and benzo[b]fluoranthene in two samples. The other PAHs, anthracene, fluoranthene and pyrene are present in almost all the samples.  相似文献   

5.
A high-performance liquid chromatographic method for the determination of fluoranthene, benzo(b)fluoranthene, benzo(k)fluoranthene, benzo(a)pyrene, benzo(g,h,i)perylene and indeno(1,2,3-cd)pyrene in water is presented. The analytical procedure consists of on-site solid-phase extraction of the analytes on a selective sample column using a new device, transport and integration of the loaded sample column into a HPLC-system and coupled-column HPLC-analysis. The method allows reliable quantification of the PAHs at the low ng/l-level in particle-free as well as in particle-containing surface water.Dedicated to Professor Dr. Dr. h.c. mult. J. F. K. Huber on the occasion of his 70th birthday  相似文献   

6.
Supercritical fluid extraction was applied to the determination of naturally contaminated polycyclic aromatic hydrocarbons (PAHs) in bird tissue by liquid chromatography with fluorescence detection (LC-FL). Recoveries (> 90%) and relative standard deviations (< or = 7.7%) were satisfactory. The levels of 10 PAHs were analyzed in 6 classes of tissues (heart, liver, intestine, muscle, lung, and kidney) of 10 buzzards and 2 tawny owls, predatory birds from the Galicia (northwest Spain). The PAHs found most abundantly were pyrene, fluoranthene, benzo[a]anthracene, and anthracene. Chrysene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[ghi]perylene, and indeno[1,2,3-cd]pyrene were not detected. Intestine, kidney, and lung were more polluted than other tissues.  相似文献   

7.
This paper presents a trisolvent ultrasonic extraction and HPLC analysis method for the determination of 11 polycyclic aromatic hydrocarbons in air particulate collected on an air filter by a commercial high volume air sampler. A reverse phase column, Vydac 201 TP, and a gradient mobile phase, acetonitrile/water, were used. The 11 PAHs, fluoranthene, pyrene, benz[a]anthracene, chrysene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, dibenz[a, h]anthracene, benzo[ghi]perylene, indeno[1,2,3-cd]pyrene, and coronene were completely resolved under experimental conditions. All the PAHs except coronene were monitored by fluorescence with λex=270 nm, λem>389 nm. Coronene was monitored by UV with λ=300 nm. The methodology was evaluated by spiking SRM 1649 with a PAH standard and then going through different extraction procedures and analyzing the PAH concentrations without clean-up. An external standard method was used for quantitation. The recovery yields for fluoranthene, benz[a]anthracene, benzo[a]pyrene, benzo[ghi]perylene and indeno[l,2,3-cd]pyrene were above 90%. The detection limits of PAH with fluorescence at λex=270 nm, λem>389 nm ranged from 5.7 pg to 69.5 pg.  相似文献   

8.
A method capable of determining 13 PAHs (acenaphthene, anthracene, benzo[a]anthracene, benzo[a]pyrene, benzo[b]fluoranthene, benzo[k]fluoranthene, chrysene, dibenzo[ah]anthracene, fluoranthene, fluorene, indene[1,2,3-cd]pyrene, phenanthrene and pyrene) in a mixture of 16 EPA PAHs by second derivative synchronous spectrofluorometry in the constant wavelength mode was developed. It has not been possible to determine the following PAHs in the mixture: acenaphthylene, benzo[ghi]perylene and naphthalene. The approach studied allows the sensitive, rapid and inexpensive identification and quantitation of 13 PAHs in a solution of hexane. The detection limits are <1 microg L(-1) (except for chrysene and phenanthrene).  相似文献   

9.
A fast and simple preparation procedure based on the matrix solid-phase dispersion (MSPD) technique is proposed for the first time for the isolation of 16 polycyclic aromatic hydrocarbons (PAHs) from soil samples. Naphthalene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, benz[a]anthracene, chrysene, benzo[e]pyrene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, dibenzo[a,h]anthracene, benzo[g,h,i]perylene, and indeno[1,2,3-c,d]pyrene were considered in the study. Extraction and clean-up of samples were carried out in a single step. The main parameters that affect extraction yield, such as dispersant, type and amount of additives, clean-up co-sorbent and extractive solvent were evaluated and optimized. The addition of an alkali solution in MSPD was required to provide quantitative recoveries. Analytical determinations were carried out by high performance liquid chromatography (HPLC) with fluorescence detection. Quantification limits (between 0.01 and 0.6 ng g(-1) dry mass) were well below the regulatory limits for all the compounds considered. The extraction yields for the different compounds obtained by MSPD were compared with the yields obtained by microwave-assisted extraction (MAE). To test the accuracy of the MSPD technique, the optimized methodology was applied to the analysis of standard reference material BCR-524 (contaminated industrial soil), with excellent results.  相似文献   

10.
The use of derivative constant-wavelength synchronous scan fluorimetry is reported for the determination of three polycyclic aromatic hydrocarbon pollutants in drinking water (linearity range 0.4-4 mug 1(-1)). The limits of detection (LD) and quantification (LQ) (mug 1(-1)) are 0.01 and 0.07 for benzo[b]fluoranthene, 0.03 and 0.12 for benzo[a]pyrene and 0.19 and 0.57 for indeno[1,2,3-cd]pyrene in the presence of three other pollutants, benzo[k]fluoranthene, benzo[ghi]perylene and fluoranthene. The precision (RSD /= 85%) were satisfactory.  相似文献   

11.
《Analytical letters》2012,45(12):1051-1062
Abstract

Ultrasonic extraction of airborne particulate material on Hi-Vol filters is described. Almost all of the polar compounds are removed during the extraction by adsorption on the surface of the shredded glass fibers and controlled pore glass powder (CPG). The non-polar polynuclear aromatic hydrocarbons (PAH) in the extract are separated at room temperature by high pressure liquid chromatography (HPLC) on reverse phase Vydac using acetonitrile:water (70:30 v/v) as the chromatographic solvent. There is baseline separation of benzo(a)pyrene (BaP), benzo(k)fluoranthene (BkFt) and of benzo(e)pyrene (BeP), benzo(b)fluoranthene and perylene, the latter three present in one band. Extracts of airborne particulates show the same peaks. BaP elutes in approximately 14 minutes. Precision and accuracy measurements indicate full recovery of PAH and good extraction reproducibility. The detection limit of BaP at F 290/389 is less than 10 pg. Total analysis time is approximately 1 1/2 hr, most of which is waiting time.  相似文献   

12.
An interpretative strategy (factorial design experimentation+total resolution analysis+chromatogram simulation) was employed to optimize the separation of 16 polycyclic aromatic hydrocarbons (PAHs) (naphthalene, acenaphthylene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, chrysene, benzo(a)anthracene, benzo(k)fluoranthene, benzo(b)fluoranthene, benzo(a)pyrene, indeno(1,2,3-c,d)pyrene, dibenzo(a,h)anthracene, benzo(g,h,i)perylene) in temperature-programmed gas chromatography (GC). Also, the retention behavior of PAHs in the same GC system was studied by a feed-forward artificial neural network (ANN). GC separation was investigated as a function of one (linear temperature ramp) or two (linear temperature ramp+the final hold temperature) variables. The applied interpretative approach resulted in rather good agreement between the measured and the predicted retention times for PAHs in both one and two variable modeling. The ANN model, strongly affected by the number of input experiments, was shown to be less effective for one variable used, but quite successful when two input variables were used. All PAHs, including difficult to separate peak pairs (benzo(k)fluoranthene/benzo(b)fluoranthene and indeno(1,2,3-c,d)pyrene/dibenzo(a,h)anthracene), were separated in a standard (5% phenyl-95% dimethylpolysiloxane) capillary column at an optimum temperature ramp of 8.0 degrees C/min and final hold temperature in the range of 260-320 degrees C.  相似文献   

13.
A sensitive and reliable analytical method was developed for the simultaneous extraction of PAHs and total fats and their determination in the human milk. The method involved a liquid-liquid extraction of PAHs and fats, followed by the gravimetric determination of the latter. PAHs were separated from lipids by size exclusion chromatography eluting with methylene chloride and analysed by gaschromatography coupled with mass spectrometry (GC/MS). The recovery of analytes was in the range of 42-101% and agreed well with their boiling temperatures (R2=0.779). Precision of the method was found between 7.6 and 19%. Quantification and detection limits for individual PAHs ranged from 0.011 to 0.032 and from 0.006 to 0.022 microg/Kg milk (wet weight), respectively. Quantification limit for the total fat determination was 0.26 g/Kg milk (wet weight). This procedure, applied to milk samples of ten healthy, non-smoking, Italian primiparae, living in rural or low-traffic zones, allowed for the identification and quantitative determination of naphthalene, acenaphthylene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, benzo(a)anthracene, benzo(b)fluoranthene and benzo(k)fluoranthene in the mean concentration range 0.114-6.95 microg/Kg milk (wet weight). The most volatile compounds, which were not investigated elsewhere, were found at much higher concentrations than those observed for the others. No relation was found between PAH and total fat concentrations.  相似文献   

14.
The copper(II) isonicotinate (Cu(4-C5H4N-COO)2(H2O)4) coordination polymer was prepared, characterized and explored as sorbent for flow injection solid-phase extraction on-line coupled with high-performance liquid chromatography (HPLC) for determination of trace polycyclic aromatic hydrocarbons (PAHs) in environmental matrices. Naphthalene, phenanthrene, anthracene, fluoranthene, benzo(b)fluoranthene, benzo(k)fluoranthene, benzo(a)pyrene and benzo(ghi)perylene with various shape, size and hydrophobicity were used as model analytes. The porosity of the coordination polymer allows these guest PAHs molecules to diffuse into the buck structure, and the shape and size of the pores lead to shape- and size-selectivity over the guests. The precolumn packed with the coordination polymer was shown to be promising for solid-phase extraction of PAHs in environmental samples with subsequent HPLC separation and UV detection. With extraction of 50 ml of sample solution, the enhancement factors for the PAHs studied ranged from 200 to 2337, depending on the shape, size and hydrophobic property of the PAHs. The detection limits (S/N = 3) of 2-14 ng l(-1) and the sample throughput of 3 samples h(-1) were obtained. The developed method was applied to the determination of trace PAHs in a certified reference material (coal fly ash) and local water samples.  相似文献   

15.
In the present study, the solid–liquid extraction with low temperature purification was validated for the determination of 16 polycyclic aromatic hydrocarbons from sewage sludge by gas chromatography-mass spectrometry. Recoveries ranged 70–114% for naphthalene, acenaphthylene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, benzo[a]anthracene and chrysene, while the compounds benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, indeno[1,2,3-cd]pyrene, dibenzo[a,h]anthracene and benzo[g,h,i]perylene showed recoveries of between 40 and 70%. The relative standard deviation was less than 13% for all of the compounds. Negative matrix effect was observed on the 10 compounds with less retention time in the chromatographic analysis and positive matrix effect noticed on the others. The limits of quantification were from 2 to 20 μg kg?1, about 30 times less than the maximum residue limit allowed in sludge by the European Union. The validated method produced quantification of 11 PAHs in one sludge sample at concentrations ranging 20–2000 μg kg?1.  相似文献   

16.
戴雪伟  卫碧文  望秀丽  于文佳  徐永威 《色谱》2015,33(10):1059-1064
建立了一种超高效合相色谱-二极管阵列检测器快速分析塑料制品中萘、苊烯、苊、芴、菲、蒽、荧蒽、芘、苯并(a)蒽、(屈艹) 、苯并(b)荧蒽、苯并(k)荧蒽、苯并(j)荧蒽、苯并(e)芘、苯并(a)芘、茚并(1,2,3-cd)芘、二苯并(a,h)蒽、苯并(g,h,i)苝(二萘嵌苯)的方法。以甲苯为溶剂,超声萃取实际塑料制品中的多环芳烃,经超高效合相色谱分析。采用Daicel IB-3手性色谱柱,以CO2为流动相,甲醇/乙腈(25:75, v/v)为流动相助溶剂,在柱温为40 ℃,背压为15.17 MPa的条件下,18种多环芳烃在8.5 min之内实现基线分离。18种多环芳烃的线性范围为0.05~50 mg/L(r≥0.9995),定量限(S/N> 10)为0.05 mg/L。加标回收率为78.3%~117.6%,相对标准偏差(RSD, n=5)小于5%。该方法具有分析速度快、分离效率高、节约有机溶剂的优点。  相似文献   

17.
The determination of 15 polycyclic aromatic hydrocarbons (PAHs) in olive oil samples has been improved in order to obtain a fast methodology with a low limit of detection through the combination of liquid-liquid extraction with acetonitrile and preparative gel permeation chromatography (GPC) prior to the injection of purified extracts into a C18 column. Acetonitrile-water was used as the mobile phase with a gradient from 50 to 95%, w/w, acetonitrile in 30 min. The oven temperature was maintained at 15 degrees C, and fluorometric detection was made at a fixed excitation wavelength of 264 nm and variable, optimal emission wavelength for each analyte ranging from 352 nm for 11-H-benzo(b)fluorene to 500 nm for indeno(1,2,3-cd)pyrene. Recovery for all the compounds studied varied from 75 to 111%, and limit of detection values from 0.05 ng/g for benzo(k)fluoranthene to 0.48 ng/g for indeno(1,2,3-cd)pyrene, corresponding to 0.09 ng/g benzo(a)pyrene. Results were compared with those obtained by liquid-liquid extraction followed by a cleanup on silica and a direct GPC treatment of oil samples diluted in dichloromethane, 2 other methodologies that are appropriate for quantifying PAHs in olive oils. However, the proposed method improves the determination limits, reduces the time of analysis, and provides a highly stable baseline for sample chromatograms.  相似文献   

18.
Hagestuen ED  Campiglia AD 《Talanta》1999,49(3):547-560
For the first time, solid-phase extraction (SPE) has been combined to room-temperature phosphorimetry (RTP) to determine the 16 polycylic aromatic hydrocarbons related as major pollutants by the US Environmental Protection Agency (EPA). These include naphthalene, anthracene, acenaphthylene, acenaphthene, fluorene, fluoranthene, benzo(a)anthracene, benzo(k)fluoranthene, benzo(b)fluoranthene, benzo(a)pyrene, indeno(1,2,3-cd)pyrene, pyrene, chrysene, phenanthrene, benzo(g,h,i)perylene and dibenzo(a,h)anthracene. The pre-concentration factor obtained by SPE, combined with the sensitivity of RTP, resulted in calibration curves with linear dynamic ranges at the parts-per-billion level (ng ml(-1)). The limits of detection were estimated at the parts-per-trillion level (pg ml(-1)). Several pollutants usually encountered in water samples were tested for interference. These included polychlorinated biphenyls, pesticides, and volatile organic compounds. As a result of the appropriate combination of excitation wavelength (330 nm) and phosphorescence enhancers (0.1 M TlNO(3) and 0.05 M sodium dodecyl sulfate, SDS), no interference was observed. The results demonstrate the potential of SPE-RTP for screening polycyclic aromatic hydrocarbons (PAHs) in environmental waters.  相似文献   

19.
刘颖  陈玲  唐银健  黄清辉  赵建夫 《色谱》2007,25(3):356-361
建立了高效液相色谱-二极管阵列检测器(PDA)测定上海市黄浦江表层沉积物中16种多环芳烃(PAHs)的方法。在保留时间定性分析的基础上,利用PDA获取的紫外扫描光谱图对目标组分进行了准确的定性,并通过异构体紫外光谱图中特征峰的差异有效地识别了样品中的4种异构体,即苯并[b]荧蒽、 苯并[k]荧蒽、 苯并[a]芘和苯并[e]芘。通过检测波长的优化,减少了干扰物的影响,提高了检测灵敏度;针对分离度较差的两种目标组分(苯并[b]荧蒽和苯并[k]荧蒽)的定量进行了分析讨论。该方法对16种PAHs的检出限(以干基计)介于1.1~18.3 ng/g之间,具有较高的方法灵敏度。黄浦江表层沉积物测定结果表明,除二氢苊外的15种PAHs都被检出,含量为10.1~253.0 ng/g。  相似文献   

20.
张小涛  张丽  阮艺斌  王维维  姬厚伟  万强  林福呈  刘剑 《色谱》2017,35(10):1105-1110
建立了气相色谱-串联质谱同时检测卷烟滤嘴中15种多环芳烃的方法。卷烟滤嘴用二氯甲烷振荡萃取后,经0.22μm有机相滤膜过滤,采用DB-5MS色谱柱(30 m×0.25 mm,0.25μm)进行分离,电子轰击源、正离子模式下以多反应监测模式进行检测,内标法进行定量。15种多环芳烃(苊烯、苊、芴、菲、蒽、荧蒽、芘、苯并[a]蒽、屈、苯并[b]荧蒽、苯并[k]荧蒽、苯并[a]芘、二苯并[a,h]蒽、苯并[g,h,i]苝和茚并[1,2,3-c,d]芘)的线性关系良好,相关系数(R~2)为0.991 4~0.999 9。15种多环芳烃在低、中、高3个添加水平下的平均回收率为81.6%~111.2%;除了芴在低添加水平时相对标准偏差为19.2%外,其他相对标准偏差均小于16%。15种多环芳烃的检出限为0.02~0.24 ng/滤嘴,定量限为0.04~0.80 ng/滤嘴。方法前处理简便,具有快速、准确、灵敏度高及重复性好的优点,适用于卷烟滤嘴中多环芳烃的分析。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号