首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The Lewis x structure [Lex, Galbeta1-4(Fucalpha1-3)GlcNAc] motif is one of the tumor antigens and plays an important role in oncogenesis, development, cellular differentiation and adhesion. The detection of Lex-carbohydrates and their structural analysis are necessary to clarify the role of Lex in several biological events. Mass spectrometry has been preferably used for the structural analysis of carbohydrates. Especially, collision-induced dissociation (CID) tandem mass spectrometry (MS/MS), which causes a glycosidic bond cleavage, is used for carbohydrate sequencing. However, Lex cannot be identified by MS/MS due to the existence of the positional isomers, such as Lewis a [Galbeta1-3(alpha1-4Fuc)GlcNAc]. In the present study, we demonstrate the specific detection of Lex-carbohydrates in a biological sample by using multiple-stage MS/MS (MSn). Using pyridylaminated oligosaccharides bearing Lex, we found that the Lex-motif yields a cross-ring fragment by the cleavage of a bond between C-3 and C-4 of GlcNAc in Gal(Fuc)GlcNAc. The Lex-specific cross-ring fragment ion at m/z 259 was effectively detected by sequential scans, consisting of a full MS1 scan, data-dependent CID MS2 scan, MS3 of [Gal(Fuc)GlcNAc+Na]+ at m/z 534, and MS4 of [GalGlcNAc+Na]+ at m/z 388. The sequential scan was applied to N-linked oligosaccharide profiling using a LC/ESI-MSn system equipped with a graphitized carbon column. We successfully detected the Lex-motif and elucidated the structures of several Lex and Lewis y [(Fucalpha1-2)Galbeta1-4(Fucalpha1-3)GlcNAc] oligosaccharides in the murine kidney used as a model tissue. Our method is expected to be a powerful tool for the specific detection of the Lex-motif, and structural elucidation of Lex-carbohydrates in biological samples.  相似文献   

2.
Negative ion nano-liquid chromatography/mass spectrometry (nano-LC/MS) and tandem mass spectrometry (nano-LC/MS(2)), using graphitised carbon as separating medium, were explored for analysing neutral and acidic O-linked and N-linked oligosaccharide alditols. Compared to the sensitivity of capillary LC/MS (flow rate of 6 microL/min) coupled with a conventional electrospray ionisation source, the nano-LC/MS (flow rate of 0.6 microL/min) with a nanoflow ion source was shown to increase the sensitivity ten-fold with a detection limit in the low-femtomole range. The absolute signals for the [M-nH](n-) ions of the oligosaccharides were increased 100-fold, enabling accumulation of high-quality fragmentation data in MS(2) mode, in which detection of low abundant sequence ions is necessary for characterisation of highly sialylated N-linked oligosaccharides. Oligosaccharides with high numbers of sialic acid residues gave dominant fragments arising from the loss of sialic acid, and less abundant fragments from cleavage of other glycosidic bonds. Enzymatic off-line desialylation of oligosaccharides in the low-femtomole range prior to MS(2) analysis was shown to increase the quality of the spectra. Automated glycofragment mass fingerprinting using the GlycosidIQ software confirmed the oligosaccharide sequence for both neutral desialylated as well as sialylated structures. Furthermore, the use of graphitised carbon nano-LC/MS enabled the detection of four sialylated O-linked oligosaccharides on membrane proteins from ovarian tissue (5 microg of total amount of protein).  相似文献   

3.
Recent advancements in mass spectrometry including data-dependent scanning and high-resolution mass spectrometry have aided metabolite profiling for non-radiolabeled xenobiotics. However, narrowing down a site of metabolism is often limited by the quality of the collision-induced dissociation (CID)-based precursor ion fragmentation. An alternative dissociation technique, higher energy collisional dissociation (HCD), enriches compound fragmentation and yields 'triple-quadrupole-like fragmentation'. Applying HCD along with CID and data-dependent scanning could enhance structural elucidation for small molecules. Liquid chromatography/multi-stage mass spectrometry (LC/MS(n) ) experiments with CID and HCD fragmentation were carried out for commercially available compounds on a hybrid linear ion trap orbital trap mass spectrometer equipped with accurate mass measurement capability. The developed method included stepped normalized collision energy (SNCE) parameters to enhance MS fragmentation without tuning for individual compounds. All the evaluated compounds demonstrated improved fragmentation under HCD as compared with CID. The results suggest that an LC/MS(n) method that incorporated both SNCE HCD- and CID-enabled precursor ion fragmentation afforded comprehensive structural information for the compounds under investigation. A dual collision cell approach was remarkably better than one with only CID MS(n) in an orbital trap. It is evident that such an acquisition method can augment the identification of unknown metabolites in drug discovery by improving fragmentation efficiency of both the parent compound and its putative metabolite(s).  相似文献   

4.
The use of electrospray ionization (ESI) quadrupole ion trap mass spectrometry and reversed-phase high-performance liquid chromatography (HPLC) for the characterization of 2-aminobenzamide (2AB)-labeled oligosaccharides and N-linked protein oligosaccharide mixtures is described. The major signals were obtained under these conditions from the [M+Na]+ ions for all 2AB-derivatized oligosaccharides. Under collision-induced dissociation, sodiated molecular species generated in the ESI mode yield simple and predictable mass spectra. Tandem mass spectrometry (MS/MS) experiments with orders higher than two offer a number of ways to enhance MS/MS spectra and to derive information not present in MS and MS2 spectra. Information on composition, sequence, branching and, to some extent, interglycosidic linkages can be deduced from fragments resulting from the cleavage of glycosidic bonds and from weak cross-ring cleavage products. Reversed-phase HPLC and derivatization by reductive amination using 2-aminobenzamide were finally applied to characterize a glycan pool enzymatically released from glycoproteins.  相似文献   

5.
We developed an efficient and convenient strategy for protein identification and glycosylation analysis of a small amount of unknown glycoprotein in a biological sample. The procedure involves isolation of proteins by electrophoresis and mass spectrometric peptide/glycopeptide mapping by LC/ion trap mass spectrometer. For the complete glycosylation analysis, proteins were extracted in intact form from the gel, and proteinase-digested glycoproteins were then subjected to LC/multistage tandem MS (MSn) incorporating a full mass scan, in-source collision-induced dissociation (CID), and data-dependent MSn. The glycopeptides were localized in the peptide/glycopeptide map by using oxonium ions such as HexNAc+ and NeuAc+, generated by in-source CID, and neutral loss by CID-MS/MS. We conducted the search analysis for the glycopeptide identification using search parameters containing a possible glycosylation at the Asn residue with N-acetylglucosamine (203 Da). We were able to identify the glycopeptides resulting from predictable digestion with proteinase. The glycopeptides caused by irregular cleavages were not identified by the database search analysis, but their elution positions were localized using oxonium ions produced by in-source CID, and neutral loss by the data-dependent MSn. Then, all glycopeptides could be identified based on the product ion spectra which were sorted from data-dependent CID-MSn spectra acquired around localized positions. Using this strategy, we successfully elucidated site-specific glycosylation of Thy-1, glycosylphosphatidylinositol (GPI)-anchored proteins glycosylated at Asn23, 74, and 98, and at Cys111. High-mannose-type, complex-type, and hybrid-type oligosaccharides were all found to be attached to Asn23, 74 and 98, and four GPI structures could be characterized. Our method is simple, rapid and useful for the characterization of unknown glycoproteins in a complex mixture of proteins.  相似文献   

6.
Differential mobility spectrometry (DMS), also commonly referred to as high field asymmetric waveform ion mobility spectrometry (FAIMS) is a rapidly advancing technology for gas-phase ion separation. The interfacing of DMS with mass spectrometry (MS) offers potential advantages over the use of mass spectrometry alone. Such advantages include improvements to mass spectral signal/noise, orthogonal/complementary ion separation to mass spectrometry, enhanced ion and complexation structural analysis, and the potential for rapid analyte quantitation. In this report, we demonstrate the successful use of our nanoESI-DMS-MS system, with a methanol drift gas modifier, for the separation of oligosaccharides. The tendency for ESI to form oligosaccharide aggregate ions and the negative impact this has on nanoESI-DMS-MS oligosaccharide analysis is described. In addition, we demonstrate the importance of sample solvent selection for controlling nanoESI oligosaccharide aggregate ion formation and its effect on glycan ionization and DMS separation. The successful use of a tetrachloroethane/methanol solvent solution to reduce ESI oligosaccharide aggregate ion formation while efficiently forming a dominant MH(+) molecular ion is presented. By reducing aggregate ion formation in favor of a dominant MH(+) ion, DMS selectivity and specificity is improved. In addition to DMS, we would expect the reduction in aggregate ion complexity to be beneficial to the analysis of oligosaccharides for other post-ESI separation techniques such as mass spectrometry and ion mobility. The solvent selected control over MH(+) molecular ion formation, offered by the use of the tetrachloroethane/methanol solvent, also holds promise for enhancing MS/MS structural characterization analysis of glycans.  相似文献   

7.
Searchable libraries of MS/MS spectra, obtained using liquid chromatography/tandem mass spectrometry (LC/MS/MS) with data-dependent scan mode switching on both quadrupole ion trap and triple-quadrupole mass spectrometers in conjunction with electrospray ionization, are presented. The effects on library search scores of changing the parameters for producing collision-induced dissociation (CID) on both instrument types are systematically evaluated. These observations serve as a basis for determining a universal set of conditions for building MS/MS libraries. A group of 19 closely related steroids was used. The ability to obtain library-searchable spectra at low concentrations is demonstrated for the analysis of a sample of progesterone spiked with hydroxyprogesterone impurities at 0.1 and 0.01%.  相似文献   

8.
An ion source incorporating a fibre optic interface has been constructed for atmospheric pressure matrix-assisted laser desorption/ionisation quadrupole ion trap mass spectrometry. The configuration has been applied to the study of linear and complex oligosaccharides. Multi-stage tandem mass spectrometry (MSn, n = 2-4) experiments carried out in the ion trap enable extended fragmentation pathways to be investigated that yield structural information. Collisional activation of sodiated oligosaccharides, as demonstrated on the model compound maltoheptaose, produces primarily B and Y fragments resulting from cleavage of glycosidic bonds; fragments from cross-ring cleavages are also observed following further stages of tandem mass spectrometry, providing additional linkage information. The analyses of mixtures of complex oligosaccharides are demonstrated for N-linked glycans from chicken egg glycoproteins and a ribonuclease glycan mixture. Mass spectrometric and tandem mass spectrometric data for sugars with molecular weights up to 4000 Da is shown for mixtures of linear dextrans and N-linked glycans. The use of MSn (n = 3, 4) on these complex molecules enabled structural information to be elucidated that confirms data observed in the MS/MS spectra.  相似文献   

9.
Total N-linked oligosaccharide profiling method for recombinant monoclonal antibody (rmAb) using capillary electrophoresis with laser-induced fluorescence detection (CE-LIF) and an approach for detailed structural analysis of N-linked oligosaccharide were developed. A CE-LIF method using 2-aminobenzoic acid (2-AA) as a fluorogenic reagent allowed sensitive detection of several minor peaks besides typical asialo-biantennary complex type oligosaccharides in the analysis of N-linked oligosaccharide from a commercial rmAb pharmaceutical, rituximab. These minor peaks were successfully assigned as sialo-biantennary complex type and high-mannose type oligosaccharides by comparison with the migration times of 2-AA derivatized oligosaccharides which were separately fractionated and determined by high-performance liquid chromatography (HPLC) and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). In development of biopharmaceuticals, it is important to evaluate these minor oligosaccharides, because some of these minor glycans are likely to influence immunogenicity and clearance rate in vivo. The repetitive analysis using CE-LIF showed excellent precision in relative corrected peak areas. These results demonstrate that the present CE-LIF method is applicable for both structural characterization and quantitative profiling of N-linked oligosaccharides derived from rmAb pharmaceuticals. The present method will be a powerful tool for rapid, quantitative and exhaustive evaluation of N-linked oligosaccharides in various stages of rmAb pharmaceutical development such as clone selection, bioprocess control, and routine lot release testing to ensure product efficacy and consistency.  相似文献   

10.
We report herein, facile metabolite identification workflow on the anti-depressant nefazodone, which is derived from accurate mass measurements based on a single run/experimental analysis. A hybrid LTQ/orbitrap mass spectrometer was used to obtain accurate mass full scan MS and MS/MS in a data-dependent fashion to eliminate the reliance on a parent mass list. Initial screening utilized a high mass tolerance ( approximately 10 ppm) to filter the full scan MS data for previously reported nefazodone metabolites. The tight mass tolerance reduces or eliminates background chemical noise, dramatically increasing sensitivity for confirming or eliminating the presence of metabolites as well as isobaric forms. The full scan accurate mass analysis of suspected metabolites can be confirmed or refuted using three primary tools: (1) predictive chemical formula and corresponding mass error analysis, (2) rings-plus-double bonds, and (3) accurate mass product ion spectra of parent and suspected metabolites. Accurate mass characterization of the parent ion structure provided the basis for assessing structural assignment for metabolites. Metabolites were also characterized using parent product ion m/z values to filter all tandem mass spectra for identification of precursor ions yielding similar product ions. Identified metabolite parent masses were subjected to chemical formula calculator based on accurate mass as well as bond saturation. Further analysis of potential nefazodone metabolites was executed using accurate mass product ion spectra. Reported mass measurement errors for all full scan MS and MS/MS spectra was <3 ppm, regardless of relative ion abundance, which enabled the use of predictive software in determining product ion structure. The ability to conduct biotransformation profiling via tandem mass spectrometry coupled with accurate mass measurements, all in a single experimental run, is clearly one of the most attractive features of this methodology.  相似文献   

11.
An analog of aildenafil, which is a potent and highly selective inhibitor of phosphodiesterase 5, was found in a dietary supplement marketed for enhancement of sexual function. The compound was isolated by silica gel column chromatography, and its structure was identified by means of 13C-NMR spectrometry, 1H-NMR spectrometry, high-resolution MS, and X-ray structure determination. The compound was identified to be sulfoaildenafil (other names: thioaildenafil, dimethyl sildenafil thione, and thiomethisosildenafil). Sulfoaildenafil is very similar to the compound thiohomosildenafil. As it is difficult to distinguish between them by LC-photodiode array detector analysis, ultra-performance LC (UPLC)/MS, ion trap LC/MS/MS (LC/IT-MS/MS), and GC/MS were performed. The mass spectra of thiohomosildenafil by UPLC/MS and LC/IT-MS/MS showed mass fragments of m/z 58, 72, and 355, and the mass spectrum by GC/MS showed mass fragments of m/z 56, 72, and 420. Some of these fragments had low intensities, but they were useful for distinguishing between the two compounds. The relationship between aildenafil (other names: dimethylsildenafil and methisosildenafil) and homosildenafil is similar to that between sulfoaildenafil and thiohomosildenafil. Therefore, these compounds were also examined.  相似文献   

12.
We have previously demonstrated that liquid chromatography/mass spectrometry equipped with a graphitized carbon column (GCC-LC/MS) is useful for the structural analysis of carbohydrates in a glycoprotein. Here, we studied the monosaccharide composition analysis and quantitative oligosaccharide profiling by GCC-LC/MS. Monosaccharides were labeled with 2-aminopyridine and then separated and monitored by GCC-LC/MS in the selective ion mode. The use of tetradeuterium-labeled pyridylamino (d4-PA) monosaccharides as internal standards, which were prepared by the tagging of standard monosaccharides with hexadeuterium-labeled 2-aminopyridine (d6-AP), afforded a good linearity and reproducibility in ESIMS analysis. This method was successfully applied to the monosaccharide composition analysis of model glycoproteins, fetuin, and erythropoietin. For quantitative oligosaccharide profiling, oligosaccharides released from an analyte and a standard glycoprotein were tagged with d0- and d6-AP, respectively, and an equal amount of d0- and d4-PA oligosaccharides were coinjected into GCC-LC/MS. In this procedure, the oligosaccharides that existed in either analyte or a standard glycoprotein appeared as single ions, and the oligosaccharides that existed in both analyte and a standard glycoprotein were detected as paired ions. The relative amount of analyte oligosaccharides could be determined on the basis of the analyte/internal standard ion-pair intensity ratio. The quantitative oligosaccharide profiling enabled us to make a quantitative and qualitative comparison of glycosylation between the analyte and standard glycoproteins. The isotope tag method can be applicable for quality control and comparability assessment of glycoprotein products as well as the analysis of glycan alteration in some diseases.  相似文献   

13.
The use of the recently introduced Q-Trap mass spectrometer in the study of protein glycosylation is described. The combined ion trap and triple quadrupole scan functions make it a powerful system in both oligosaccharide and glycopeptide analysis. Several oligosaccharides, both linear and branched, were analyzed to obtain information on sequence, linkage, and branching. Quadrupole like MS/MS spectra with ion trap sensitivity but without the typical ion trap low mass cut-off were obtained. To determine the origin of fragments and to reveal the existence of new ions, the MS(3) capabilities of the system proved to be useful. Glycopeptides were selectively detected in peptide mixtures using the triple quadrupole precursor ion scan function, either in off-line experiments or during LC/MS using information dependent acquisition (IDA).  相似文献   

14.
Liquid chromatography mass spectrometry (LC-MS) peptide mapping can be a versatile technique for characterizing protein glycosylation sites without the need to remove the attached glycans as in conventional oligosaccharide mapping methods. In this way, both N-linked and O-linked sites of glycosylation can each be directly identified, characterized, and quantified by LC-MS as intact glycopeptides in a single experiment. LC-MS peptide mapping of the individual glycosylation sites avoids many of the limitations of preparing and analyzing an entire pool of released N-linked oligosaccharides from all sites mixed together. In this study, LC interfaced to a linear ion trap mass spectrometer (ESI-LIT-MS) were used to characterize the glycosylation of a recombinant IgG1 monoclonal antibody and a CTLA4-Ig fusion protein with multiple sites of N-and O-glycosylation. Samples were reduced, S-carboxyamidomethylated, and cleaved with either trypsin or endoproteinase Asp-N. Enhanced detection for minor IgG1 glycoforms (~0.1 to 1.0 mol% level) was obtained by LC-MS of the longer 32-residue Asp-N glycopeptide (4+ protonated ion) compared to the 9-residue tryptic glycopeptide (2+ ion). LC-MS peptide mapping was run according to a general procedure: (1) Locate N-linked and/or O-linked sites of glycosylation by selected-ion-monitoring of carbohydrate oxonium fragment ions generated by ESI in-source collision-induced dissociation (CID), i.e. 204, 366, and 292 Da marker ions for HexNAc, HexNAc-Hex, and NeuAc, respectively; (2) Characterize oligosaccharides at each site via MS and MSMS. Use selected ion currents (SIC) to estimate relative amounts of each glycoform; and (3) Measure the percentage of site-occupancy by searching for any corresponding nonglycosylated peptide.  相似文献   

15.
Gas chromatography/mass spectrometry (GC/MS) is applied to the analysis of volatile and thermally stable compounds, while liquid chromatography/atmospheric pressure chemical ionization mass spectrometry (LC/APCI‐MS) and liquid chromatography/electrospray ionization mass spectrometry (LC/ESI‐MS) are preferred for the analysis of compounds with solution acid‐base chemistry. Because organic explosives are compounds with low polarity and some of them are thermally labile, they have not been very well analyzed by GC/MS, LC/APCI‐MS and LC/ESI‐MS. Herein, we demonstrate liquid chromatography/negative ion atmospheric pressure photoionization mass spectrometry (LC/NI‐APPI‐MS) as a novel and highly sensitive method for their analysis. Using LC/NI‐APPI‐MS, limits of quantification (LOQs) of nitroaromatics and nitramines down to the middle pg range have been achieved in full MS scan mode, which are approximately one order to two orders magnitude lower than those previously reported using GC/MS or LC/APCI‐MS. The calibration dynamic ranges achieved by LC/NI‐APPI‐MS are also wider than those using GC/MS and LC/APCI‐MS. The reproducibility of LC/NI‐APPI‐MS is also very reliable, with the intraday and interday variabilities by coefficient of variation (CV) of 0.2–3.4% and 0.6–1.9% for 2,4,6‐trinitrotoluene (2,4,6‐TNT). Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

16.
The identification and structure elucidation of drug metabolites is one of the main objectives in in vitro ADME studies. Typical modern methodologies involve incubation of the drug with subcellular fractions to simulate metabolism followed by LC-MS/MS or LC-MS(n) analysis and chemometric approaches for the extraction of the metabolites. The objective of this work was the software-guided identification and structure elucidation of major and minor buspirone metabolites using capillary LC as a separation technique and ion trap MS(n) as well as electrospray ionization orthogonal acceleration time-of-flight (ESI oaTOF) mass spectrometry as detection techniques.Buspirone mainly underwent hydroxylation, dihydroxylation and N-oxidation in S9 fractions in the presence of phase I co-factors and the corresponding glucuronides were detected in the presence of phase II co-factors. The use of automated ion trap MS/MS data-dependent acquisition combined with a chemometric tool allowed the detection of five small chromatographic peaks of unexpected metabolites that co-eluted with the larger chromatographic peaks of expected metabolites. Using automatic assignment of ion trap MS/MS fragments as well as accurate mass measurements from an ESI oaTOF mass spectrometer, possible structures were postulated for these metabolites that were previously not reported in the literature.  相似文献   

17.
A method based on sequential degradation, p-aminobenzoic ethyl ester (ABEE) closed-ring labeling, and negative ion electrospray ionization tandem mass spectrometry is presented for the study of linkage and branch determination for N-linked oligosaccharides. Closed-ring labeling provides greater linkage information than the more popular open-ring reductive amination approach. In addition, after high-performance liquid chromatography (HPLC) separation, closed-ring labeling allows for regeneration of the underivatized oligosaccharide, a requirement for alkaline sequential degradation. The analytical scheme presented here uses HPLC separation of closed-ring labeled oligosaccharides to resolve the mixture into individual forms that undergo subsequent structural analysis by negative ion tandem mass spectrometry. To facilitate complete structural analysis, particularly for larger sugars, the closed-ring labels are removed and the sugars are sequentially degraded by controlled alkaline hydrolysis. It is noteworthy that for sugars containing sialic acid moieties, a protecting group must be used to stabilize sialic acid groups during sequential alkaline degradation. This described approach was applied to two high mannose oligosaccharides M5G2, M6G2 cleaved from the ribonuclease B and a complex oligosaccharide A2 cleaved from transferrin.  相似文献   

18.
Targeted tandem mass spectrometry (MS/MS) is an attractive proteomic approach that allows selective identification of peptides exhibiting abundance differences, e.g., between culture conditions and/or diseased states. Herein, we report on a targeted LC-MS/MS capability realized with a hybrid quadrupole-7 tesla Fourier transform ion cyclotron resonance (FTICR) mass spectrometer that provides data-dependent ion selection, accumulation, and dissociation external to the ICR trap, and a control software that directs intelligent MS/MS target selection based on LC elution time and m/z ratio. We show that the continuous on-the-fly alignment of the LC elution time during the targeted LC-MS/MS experiment, combined with the high mass resolution of FTICR MS, is crucial for accurate selection of targets, whereas high mass measurement accuracy MS/MS data facilitate unambiguous peptide identifications. Identification of a subset of differentially abundant proteins from Shewanella oneidensis grown under suboxic versus aerobic conditions demonstrates the feasibility of such approach.  相似文献   

19.
Combining source collision-induced dissociation (CID) and tandem mass spectral acquisition in a pseudo-MS(3) experiment using a linear ion trap results in a highly selective and sensitive approach to identifying glycopeptide elution from a protein digest. The increased sensitivity is partially attributed to the nonselective nature of source CID, which allows simultaneous activation of all charge states and coeluting glycoforms generating greater ion abundance for the mass-to-charge (m/z) 204 and/or 366 oxonium ions. Unlike source CID alone, a pseudo-MS(3) approach adds selectivity while improving sensitivity by eliminating chemical noise during the tandem mass spectral acquisition of the oxonium ions in the linear ion trap. Performing the experiments in the hybrid linear ion trap/Fourier transform-ion cyclotron resonance (FT-ICR) enables subsequent high-resolution/high-mass accuracy full-scan mass spectra (MS) and parallel acquisition of MS/MS in the linear ion trap to be completed in 2 s directly following the pseudo-MS(3) scan to collate identification and characterization of glycopeptides in one experimental scan cycle. Analysis of bovine fetuin digest using the combined pseudo-MS(3), high-resolution MS, and data-dependent MS/MS events resulted in identification of four N-linked and two O-linked glycopeptides without enzymatic cleavage of the sugar moiety or release of the sialic acids before analysis. In addition, over 95% of the total protein sequence was identified in one analytical run.  相似文献   

20.
A novel LC/MS/MS method that uses multiple ion monitoring (MIM) as a survey scan to trigger the acquisition of enhanced product ions (EPI) on a hybrid quadrupole-linear ion trap mass spectrometer (Q TRAP) was developed for drug metabolite identification. In the MIM experiment, multiple predicted metabolite ions were monitored in both Q1 and Q3. The collision energy in Q2 was set to a low value to minimize fragmentation. Results from analyzing ritonavir metabolites in rat hepatocytes demonstrate that MIM-EPI was capable of targeting a larger number of metabolites regardless of their fragmentation and retained sensitivity and duty cycle similar to multiple reaction monitoring (MRM)-EPI. MIM-based scanning methods were shown to be particularly useful in several applications. First, MIM-EPI enabled the sensitive detection and MS/MS acquisition of up to 100 predicted metabolites. Second, MIM-MRM-EPI was better than MRM-EPI in the analysis of metabolites that undergo either predictable or unpredictable fragmentation pathways. Finally, a combination of MIM-EPI and full-scan MS (EMS), as an alternative to EMS-EPI, was well suited for routine in vitro metabolite profiling. Overall, MIM-EPI significantly enhanced the metabolite identification capability of the hybrid triple quadrupole-linear ion trap LC/MS.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号