首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Zhang L  Zhang W  Ping G  Zhang Y  Kettrup A 《Electrophoresis》2002,23(15):2417-2423
A theoretical study on the velocity of electroosmotic flow (EOF) and the retention times of neutral solutes under multiple-step gradient of capillary electrochromatography (CEC) was carried out, focusing on that with three kinds of mobile phases. Through the model computations, the detaining time of the second kind of mobile phase in the column was proved to play an important role in affecting EOF. The variation speed of EOF was shown to be determined by the differences among dead times in different steps. In addition, the prediction of the retention times of 13 aromatic compounds under gradient mode was performed with the deduced equations. A relative error below 3.3% between the calculated and experimental values was obtained, which demonstrated the rationality of the theoretical deduction. Our study could not only improve the comprehension of stepwise gradient elution, but also be of significance for the further optimization of separation conditions in the analysis of complex samples.  相似文献   

2.
尤慧艳  张维冰  阎超  张玉奎 《色谱》2002,20(3):237-240
 对中性溶质在氰基柱上的毛细管电色谱(CEC)分离特征进行了研究 ,讨论了流动相中有机调节剂种类及其体积分数、缓冲液种类等对溶质迁移速率的影响。通过对样品在氰基柱上的分离行为与其在反相ODS柱和正相SI柱上的分离行为的比较 ,说明中性溶质在氰基柱上的分离机理既具有部分反相特征又具有部分正相特征。受两种机理的影响 ,在不同的操作条件下极性不同的中性溶质在氰基柱上的迁移速率差别很大 ,较一般的正相和反相电中更易出现出峰顺序变化的现象 ,也说明这种分离模式更易于进行分离选择性调节。  相似文献   

3.
A neutral octadecyl monolithic (ODM) column for RP capillary electrochromatography (RP-CEC) has been developed. The ODM column was prepared by the in situ polymerization of octadecyl acrylate (ODA) as the monomer and trimethylolpropanetrimethacrylate (TRIM) as the crosslinker, in a ternary porogenic solvent containing cyclohexanol, ethylene glycol, and water. The ODM column exhibited cathodal EOF over a wide range of pH and ACN concentration in the mobile phase despite the fact that it was devoid of any fixed charges. It is believed that the EOF is due to the adsorption of ions from the mobile phase onto the surface of the monolith thus imparting to the neutral ODM column the zeta potential necessary to support the EOF required for mass transport across the monolithic column. Furthermore, the adsorption of mobile phase ions to the neutral monolith modulated solute retention and affected the separation selectivity. The wide applications of the neutral ODM column were demonstrated by its ability to separate a wide range of small and large solutes, both neutral and charged. While the separation of the neutral solutes was based on RP retention mechanism, the charged solutes were separated on the basis of their electrophoretic mobility and hydrophobic interaction with the C18 ligands of the stationary phase. As a typical result, the neutral monolithic column was able to separate peptides quite rapidly with a separation efficiency of nearly 200,000 plates/m, and this efficiency was exploited in tryptic peptide mapping of standard proteins, e. g., lysozyme and cytochrome C, by isocratic elution.  相似文献   

4.
Mixed packing capillary electrochromatography (MP CEC) with the stationary phase comprising a physical mixture of strong cation exchange (SCX) phase and octadecysilyl (ODS) phase was developed. With the existence of a sulfonic acid group on the surface of SCX, not only could the electroosmotic flow (EOF) remain high at low pH, but also the hydrophilicity of the stationary phase was increased greatly, leading to broad adaptable ranges of both pH and organic modifier concentration in the mobile phase. At the same time, with the coexistence of C18 on the surface of ODS, both the retention and the resolution of samples were improved. Accordingly, MP CEC combined the advantages of both SCX and ODS columns. Effects of operation parameters on EOF and the capacity factors of solutes as well as the retention mechanism of such a column were studied systematically. In addition, MP CEC columns were used in the analysis of strong polar solutes as well as for the high speed separation of acidic, basic, and neutral compounds in a single run.  相似文献   

5.
A new kind of monolithic capillary electrochromatography column with poly(styrene‐co‐divinylbenzene‐co‐methacrylic acid) as the stationary phase has been developed. The stationary phase was found to be porous by scanning electron microscopy and the composition of the continuous bed was proved by IR spectroscopy to be the ternary polymer of styrene, divinylbenzene, and methacrylic acid. The effects of operating parameters, such as voltage, electrolyte, and organic modifier concentration in the mobile phase on electroosmotic flow were studied systematically. The retention mechanism of neutral solutes on such a column proved to be similar to that of reversed‐phase high performance liquid chromatography. In addition, fast analyses of phenols, chlorobenzenes, anilines, isomeric compounds of phenylenediamine and alkylbenzenes within 4.5 min were achieved.  相似文献   

6.
A neutral, nonpolar monolithic capillary column was evaluated as a hydrophobic stationary phase in pressurized CEC system for neutral, acidic and basic solutes. The monolith was prepared by in situ copolymerization of octadecyl methacrylate and ethylene dimethacrylate in a binary porogenic solvent consisting of cyclohexanol/1,4‐butanediol. EOF in this hydrophobic monolithic column was poor; even the pH value of the mobile phase was high. Because of the absence of fixed charges, the monolithic capillary column was free of electrostatic interactions with charged solutes. Separations of neutral solutes were based on the hydrophobic mechanism with the pressure as the driving force. The acidic and basic solutes were separated under pressurized CEC mode with the pressure and electrophoretic mobility as the driving force. The separation selectivity of charged solutes were based on their differences in electrophoretic mobility and hydrophobic interaction with the stationary phase, and no obvious peak tailing for basic analytes was observed. Effects of the mobile phase compositions on the retention of acidic compounds were also investigated. Under optimized conditions, high plate counts reaching 82 000 plates/m for neutral compounds, 134 000 plates/m for acid compounds and 150 000 plates/m for basic compounds were readily obtained.  相似文献   

7.
Lü H  Wang J  Wang X  Wu X  Lin X  Xie Z 《Journal of separation science》2007,30(17):2993-2999
A monolithic stationary phase was prepared in a single step by in situ copolymerization of iso-butyl methacrylate (IBMA), ethylene dimethacrylate (EDMA), and N,N-dimethylallylamine (DMAA) in a binary porogenic solvent consisting of N,N-dimethylformamide (DMF) and 1,4-butanediol. As the frame structures of monoliths, the amino groups are linked to support the EOF necessary for driving the mobile phase through the monolithic capillary, while the hydrophobic groups are introduced to provide the nonpolar sites for the chromatographic retention. To evaluate the column performance, separations of typical kinds of neutral or charged homologs, such as alkylbenzenes, phenols (including isomeric compounds of hydroquinone, resorcin, and catechol), and anilines (including isomeric compounds of o-phenylenediamine and 1,4-phenylenediamine), were performed, respectively on the prepared column under the mode of pressurized pCEC. Effects of the buffer pH and the mobile phase composition on the linear velocity of mobile phase and the retention factors of these compounds were investigated. It was found that the retention mechanism of charged solutes could be attributed to a mixed mode of hydrophobic interaction and electrophoresis, while an RP chromatographic behavior on the monolithic stationary phases was exhibited for neutral solutes. Especially, basic compounds such as anilines were well separated on the monolithic columns in the "counterdirectional mode," which effectively eliminated the electrostatic adsorption of basic analytes on the charged surface of the stationary phases.  相似文献   

8.
Summary Acidic and neutral compounds have been separated by strong anion-exchange capillary electrochromatography (SAXCEC) dynamically modified by addition of sodium dodecylsulfate (SDS). It was found that separation of neutral solutes by SAXCEC without addition of SDS is difficult because of the weak interaction of the solutes with the hydrophilic packing surface. The hydrophobicity of the packing surface increases on addition of SDS to the mobile phase, however, and the capacity of separating neutral solutes increases. Acidic solutes are retained, mainly because of the ion-exchange properties of this system. The influence of mobile phase composition, e.g. SDS concentration, ionic strength, and organic modifier fraction, on the retention of acidic and neutral solutes was investigated. Three acids and five neutral solutes were separated in only 5 min under optimized conditions, because the direction of the strong electroosmotic flow (EOF) was the same as that of electrophoretic migration of the acids under the conditions used. The repeatability of this system in terms of migration time relative standard deviation (RSD) is good—less than 0.48% for 10 consecutive runs of all the solutes tested. Column efficiencies for acids were > 125000 plates m−1; those for neutral solutes varied from 25000 to 100000 plates m−1.  相似文献   

9.
 采用原位聚合的方法在毛细管中合成了非电荷型连续床电色谱原位柱 ,通过在电色谱流动相中加入阴离子表面活性剂十二烷基硫酸钠 (SDS)进行动态改性使其产生电渗流 ,考察了SDS浓度及有机改性剂浓度等因素对电渗流的影响。此类连续床柱制备容易 ,柱效可达 14万理论塔板 /m ,在不同的操作条件下有良好的稳定性 ,连续 10次运行 ,其死时间t0 与保留时间的精密度分别为 0 .2 2 %和 <0 .5 6 %。  相似文献   

10.
Bedair M  El Rassi Z 《Electrophoresis》2002,23(17):2938-2948
A novel monolithic stationary phase having long alkyl chain ligands (C17) was introduced and evaluated in capillary electrochromatography (CEC) of small neutral and charged species. The monolithic stationary phase was prepared by the in situ copolymerization of pentaerythritol diacrylate monostearate (PEDAS) and 2-acrylamido-2-methyl-1-propanesulfonic acid (AMPS) in a ternary porogenic solvent consisting of cyclohexanol/ethylene-glycol/water. While AMPS was meant to support the electroosmotic flow (EOF) necessary for transporting the mobile phase through the monolithic capillary, the PEDAS was introduced to provide the nonpolar sites for chromatographic retention. Monolithic columns at various EOF velocities were readily prepared by conveniently adjusting the amount of AMPS in the polymerization solution as well as the composition of the porogenic solvent. The monolithic stationary phases thus obtained exhibited reversed-phase chromatography behavior toward neutral solutes and yielded a relatively strong EOF. For charged solutes (e.g., dansyl amino acids), nonpolar as well as electrostatic interaction/repulsion with the monoliths were observed in addition to electrophoretic migration. Therefore, for charged solutes, selectivity and migration can be readily manipulated by changing various parameters including the nature of the monolith and the composition of the mobile phase (e.g., pH, ionic strength and organic modifier). Ultrafast separation on the time scale of seconds of 17 different charged and neutral pesticides and metabolites were performed using short capillary columns of 8.5 cm x 100 microm ID.  相似文献   

11.
Ye F  Xie Z  Wu X  Lin X  Chen G 《Journal of chromatography. A》2006,1117(2):170-175
A novel stationary phase phenylaminopropyl silica (PhA-silica) monolith was successfully prepared for pressure assisted capillary electrochromatography (pCEC). The monolithic silica matrix from a sol-gel process was chemically modified by using [3-(phenylamino)propyl]trimethoxysilane as surface modification reagent to produce the phenylaminoporpyl function. The secondary amino groups on the surface of the monolithic stationary phase contributed to the generation of anodic electroosmotic flow (EOF) under acidic conditions. The phenyl group together with the spacer (-(CH(2))(3)-) in PhA-silica provides sufficient hydrophobic properties. To evaluate the column performance, effects of buffer pH and mobile phase composition on the mobile phase linear velocity and the retention factors of alkylbenzenes, phenols and anilines were investigated in pCEC mode. The monolithic stationary phases exhibit typical reversed-phase (RP) electrochromatographic behavior toward neutral solutes. Hydrophobic as well as electrophoretic migration process within the monoliths was observed for the separation of basic solutes such as anilines without peak tailing.  相似文献   

12.
Xu L  Sun Y 《Journal of chromatography. A》2008,1183(1-2):129-134
The use of a phenylalanine (Phe) functionalized tentacle-type polymer coated capillary column for protein separation by open tubular capillary electrochromatography (OTCEC) was demonstrated in this work. The tentacle-type stationary phase was prepared from silanized fused-silica capillaries of 50 microm I.D. by glycidyl methacrylate graft polymerization and subsequent Phe functionalization. Due to the amphoteric functional groups of the Phe bonded on the tentacle-type polymer stationary phase, protein separation in the prepared column can be performed under both cathodic and anodic electroosmotic flow (EOF) by varying the pH values of the mobile phase. Model proteins including ribonuclease A (RNase A), myoglobin, transferrin, insulin were baseline separated under cathodic EOF with a mobile phase of pH 8.8. Comparison between the separation result of the four proteins under conditions of OTCEC and capillary zone electrophoresis indicates that the migration behavior of the four proteins in the prepared column was the result of the interplay of chromatographic retention and electrophoretic migration. Besides, three basic proteins including RNase A, cytochrome c (Cyt-c) and lysozyme (Lys) were fully resolved under anodic EOF with an acidic running buffer (pH 2.5). The elution order was the same as the isoelectric point values of the proteins (RNase A相似文献   

13.
A neutral naphthyl methacrylate‐based monolith (NMM) was introduced for RP‐CEC of various aromatic compounds via hydrophobic and π interactions. It was characterized over a wide range of elution conditions to gain insight into its RP retention mechanism toward the various solute probes under investigation. First, the NMM column exhibited cathodal EOF at various mobile phase compositions and pH suggesting that although the NMM column is void of fixed charges, it acquires a negative zeta potential. It is believed that the negative zeta potential is imparted by the adsorption of mobile phase ions to the NMM surface. The NMM column exhibited π–π interactions in addition to hydrophobic interactions due to the aromatic and nonpolar nature of its naphthyl ligands. In all cases, the retention of the various aromatic test solutes including PAHs, benzene derivatives, toluene derivatives, anilines and toluidine, tolunitrile and nitrotoluene positional isomers on the NMM column were compared to their retention on an octadecyl acrylate‐based monolithic column. Not only were the values of the retention factors of the various solutes on the NMM column higher than those obtained on the octadecyl acrylate‐based monolithic column under otherwise the same CEC conditions, but the elution orders were also different on both columns with a superior and unique selectivity exhibited by the NMM column.  相似文献   

14.
单亦初  张玉奎  赵瑞环 《色谱》2002,20(4):289-294
 根据溶质在柱内的迁移规律 ,建立了一种利用线性梯度实验快速获得溶质保留值方程系数 ,然后以串行响应函数为优化指标进行多台阶梯度分离条件优化的方法。与利用等度实验获得保留值方程的方法相比 ,该法可以大大缩短优化时间。通过该方法对芳香胺和衍生化氨基酸样品进行了分离 ,获得了满意的分离度 ,表明该方法的预测精度很好。  相似文献   

15.
A novel silica monolithic stationary phase functionalized with 3-(2-aminoethylamino)propyl ligands for pressurized CEC has been presented. The monolithic capillary columns were prepared by a sol-gel process in 75 microm id fused-silica capillaries and followed by a chemical modification. The diamino groups on the surface of the stationary phase are meant to generate the chromatographic surface and a substantial anodic EOF as well as to provide electrostatic interaction sites for charged solutes. The electrochromatographic characterization and column performance were evaluated by a variety of neutral and charged solutes. It was observed that the anodic EOF for the diamine-bonded monolith was greatly affected by the reaction time with 3-(2-aminoethylamino)propyltrimethoxysilane and the PEG amount in the sol-gel reaction mixture in addition to the mobile phase conditions. The monolithic stationary phase exhibited hydrophilic interaction chromatographic behavior toward neutral solutes. Good separations of various solutes including phenols, nucleic acid bases, nucleosides and nucleotides were achieved under different experimental conditions. Fast and efficient separations were obtained with high plate counts reaching more than 130,000 plates/m.  相似文献   

16.
Molecular species of neutral phospholipids, phosphatidylcholine (PC) and phosphatidylethanolamine (PE), were resolved by reversed-phase high-performance liquid chromatography (HPLC) using mobile phases of acetonitrile-methanol-water containing tetraalkylammonium phosphates (TAAPs). Competitive interactions of TAAPs and analyte solutes with a reversed-phase HPLC column resulted in reduced retention of PC or PE with concomitant increase in detection sensitivity. The chromatographic data for PC and PE were distinctly different from those for negatively charged phospholipids where ion-pair retention mechanisms prevailed. While PC (or PE) components eluted at longer retention times with a larger size of TAAP, an increase in the TAAP concentration invariably caused a decrease in phospholipid retention times. Optimization of HPLC conditions by using high concentrations (25-100 mM) of tetramethylammonium phosphate in acetonitrile-methanol-water (70:22:8) facilitated elution of components with improved peak symmetry. HPLC separations of neutral phospholipids derived from animal sources were more complex than those from soybeans.  相似文献   

17.
溶质在动态改性氧化锆液相色谱柱上的保留行为   总被引:3,自引:2,他引:1  
张庆合  冯钰  严俐  达世禄 《色谱》1999,17(3):229-231
分别采用硬脂酸、环糊精和十二烷基磺酸钠动态改性自制的ZrO2微球,研究了流动相中甲醇和改性剂浓度对苯酚及苯甲酸的衍生物、苯胺衍生物及芳香烃类化合物的色谱保留行为的影响。中性及碱性化合物的保留时间较短,色谱峰对称;酸性化合物保留时间较长,色谱峰拖尾较严重。改性氧化锆表现出反相色谱性能。  相似文献   

18.
The influence of several experimental parameters (pH, ionic strength, organic modifier content of hydro‐organic buffer) upon EOF, migration time, and retention factor has been studied in CEC with a phenyl‐bonded silica column on a model mixture of five nucleosides. This paper illustrates the current interest in CEC as a method of resolving complex mixtures of neutral and ionic solutes and demonstrates the potential of the short‐end injection method as a means of reducing analysis time.  相似文献   

19.
Wu R  Zou H  Ye M  Lei Z  Ni J 《Electrophoresis》2001,22(3):544-551
A mode of capillary electrochromatography (CEC), based on the dynamical adsorption of surfactants on the uncharged monolithic stationary phases has been developed. The monolithic stationary phase, obtained by the in situ polymerization of butyl methacrylate with ethylene dimethacrylate, was dynamically modified with an ionic surfactant such as the long-chain quaternary ammonium salt of cetyltrimethylammonium bromide (CTAB) and long-chain sodium sulfate of sodium dodecyl sulfate (SDS). The ionic surfactant was adsorbed on the surface of polymeric monolith by hydrophobic interaction, and the ionic groups used to generate the electroosmotic flow (EOF). The electroosmotic mobility through these capillary columns increased with increasing the content of ionic surfactants in the mobile phase. In this way, the synthesis of the monolithic stationary phase with binary monomers can be controlled more easily than that with ternary monomers, one of which should be an ionic monomer to generate EOF. Furthermore, it is more convenient to change the direction and magnitude of EOF by changing the concentration of cationic or anionic surfactants in this system. An efficiency of monolithic capillary columns with more than 140000 plates per meter for neutral compounds has been obtained, and the relative standard deviations observed for to and retention factors of neutral solutes were about 0.22% and less than 0.56% for ten consecutive runs, respectively. Effects of mobile phase composition on the EOF of the column and the retention values of the neutral solutes were investigated. Simultaneous separation of basic, neutral and acidic compounds has been achieved.  相似文献   

20.
Karenga S  El Rassi Z 《Electrophoresis》2010,31(19):3200-3206
A neutral naphthyl methacrylate-phenylene diacrylate-based monolith (NPM) was introduced for RP-CEC of various neutral and charged solute probes via hydrophobic and π interactions. The NPM column was prepared by the in situ polymerization of naphthyl methacrylate as the functional monomer and 1,4-phenylene diacrylate (PDA) as the crosslinker in a ternary porogenic solvent containing cyclohexanol, dodecanol and water. The NPM column exhibited cathodal EOF despite the fact that it was devoid of any fixed charges. NPM exhibited stronger EOF than its counterpart naphthyl methacrylate monolith (NMM) made from the in situ polymerization of naphthyl methacrylate and trimethylolpropane trimethacrylate (TRIM). As for NMM, it is believed that the EOF arises from the adsorption of mobile phase ions onto the monolith surface. The higher EOF exhibited by NPM may be attributed to the acrylate nature of PDA as compared to the methacrylate nature of TRIM, and therefore PDA has a higher binding capacity for mobile phase ions due to its higher polarity than TRIM. The adsorption of mobile phase ions together with the additional π interactions offered by the aromatic rings of the NPM matrix modulated solute retention and separation selectivity. The applications of NPM were demonstrated by the separation of a wide range of small and large solutes including peptides, tryptic peptide maps and proteins.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号