首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The applicability of a beta-lactam receptor protein for detection of beta-lactam antibiotics in milk using surface plasmon resonance (SPR) biosensor technology was investigated. The advantage of using a receptor protein instead of antibodies for detection of beta-lactams is that a generic assay, specific for the active form of the beta-lactam structure, is obtained. Two assays based on the enzymatic activity of the DD-carboxypeptidase from Actinomadura R39 were developed, using a Biacore SPR biosensor. The carboxypeptidase converts a tri-peptide into a di-peptide, a reaction which is inhibited in the presence of beta-lactams. Polyclonal antibodies against the 2 peptides were developed and used to measure the amount of enzymatic product formed (di-peptide assay) or the amount of remaining enzymatic substrate (tri-peptide assay), respectively. The 2 assays showed similar performances with respect to detection limits (1.2 and 1.5 microg/kg, respectively) and precision (coefficient of variation <5%) for penicillin G in milk. Several other beta-lactams were detected at or near their respective maximum residue limit. Furthermore, the 2 peptide assays were evaluated against 5 commercial kit tests in the screening of 195 producer milk samples. The biosensor assays showed 0% false-negative and 27% false-positive results, whereas the figures were 0% false-negative and 27-53% false-positive results for other screening tests investigated.  相似文献   

2.
The β-lactam antibiotics, including penicillins, are the most important antimicrobial substances used for mastitis treatment. Consequently, this is also the most frequently occurring type of antibiotic residues in milk. Today, in addition to the traditional microbial inhibitor tests, rapid and sensitive receptor and immunoassays are used in residue control. Due to the limitations in throughput capacity of these tests, recent applications of automated biosensor technology in food analysis are of great interest.A surface plasmon resonance (SPR)-based biosensor (Biacore) was used to design an inhibition assay to detect β-lactam antibiotics in milk. A microbial receptor protein with carboxypeptidase activity was used as detection molecule. One advantage of using this receptor protein over antibodies that are more commonly used is that only the active, intact β-lactam structure is recognized, whereas most antibodies detect both active and inactive forms. In the presence of β-lactam antibiotics the formation of a stable complex between receptor protein and antibiotic inhibits the enzymatic activity of the protein. The decrease in enzymatic activity was measured using an antibody against the degraded substrate and penicillin G in milk samples was quantitatively determined. The limit of detection of the assay for penicillin G was determined to 2.6 μg kg−1 for antibiotic-free producer milk, which is below the European maximum residue limit (MRL) of 4 μg kg−1. The coefficient of variation at 4 μg kg−1 penicillin G, ranged between 7.3 and 16% on three different days.  相似文献   

3.
Beta-lactam antibiotics (penicillins, cephalosporins) are still the most commonly used antibiotics for dairy cows in Germany. In routine milk testing, according to the German milk quality regulation, a positive result obtained for bulk tank milk by microbiological inhibitor tests needs no further confirmation, but results in reduced milk payment of 0.05 euros kg(-1) for one month. In some cases, however, further identification of the causative agent can be of interest, either if antimicrobial drugs have not knowingly been used recently, or if improper use of such drugs is denied. As a service for milk producers, our laboratory offers further analyses of violative milk samples, aiming at the identification and quantification of the inhibitor(s). In this program, a panel of microbiological inhibitor tests, receptor tests, and enzyme immunoassays (EIA) is used in a step-by-step analysis, which primarily focusses on beta-lactams, but also includes other compounds such as sulfonamides or tetracyclines, respectively. Here we report results for violative milk samples (n=63) analysed between 2003 and 2005. In most cases (95%), beta-lactam antibiotics could be identified, although not always at levels exceeding the respective MRL values. Penicillin G (mostly together with benzylpenicilloyl metabolites) could be identified in 74.6% of all samples. Other compounds identified were, in decreasing order, ceftiofur (11%), ampicillin/amoxicillin (6.3%), isoxazolyl penicillins (3.2%), and sulfonamides (1.6%). The results indicate that penicillin G is still the predominant antibiotic responsible for violative bulk tank milk samples as detected during regulatory control.  相似文献   

4.
A rapid and simple method for the simultaneous determination of penicillin G (PCG), penicillin V (PCV) and ampicillin (ABPC) in milk is described. The retention behaviour of these beta-lactam antibiotics in reversed-phase liquid chromatography with mobile phases containing sodium alkylsulphonate was studied. Good separations were obtained with methanol-water-0.2 M phosphate buffer (pH 4.0) (5:13:2) containing 11 mM sodium 1-heptanesulphonate and a LiChrosorb RP-18 column. The sample was pre-treated with a Sep-Pak C18 cartridge. The peaks corresponding to each beta-lactam antibiotics can be confirmed with the treatment using penicillinase. The recoveries from milk fortified with sodium PCG, potassium PCV and ABCP at levels of 0.5 and 0.1 micrograms/g each were generally better than 87% and the relative standard deviations were 1.17-4.98%. The detection limits corresponded to 0.03 microgram/g of these beta-lactam antibiotics in milk.  相似文献   

5.
Immuno-biosensor inhibition assays for the detection of streptomycin and dihydrostreptomycin residues in whole cows' milk, honey, pig kidney and pig muscle are reported. The antibody showed high cross-reactivity with dihydrostreptomycin in various foodstuffs (buffer 103%, milk 96%, honey 84%, kidney extract 129% and muscle extract 98%). There was no significant cross-reaction with other aminoglycosides or commonly used antibiotics. A streptomycin derivative was used to prepare a stable, reusable sensor chip surface. The assay allowed the direct analysis of bovine whole milk (fat content approximately 3.5%). Honey samples required dilution with buffer, while kidney and muscle samples from pigs were homogenized in an aqueous extraction buffer and clarified by centrifugation. The limit of detection for each assay was determined from known streptomycin-free samples (n = 20; mean - (3 x standard deviation)) and the results were as follows: milk 30 microg kg(-1), honey 15 microg kg(-1), kidney 50 microg kg(-1) and muscle 70 microg kg(-1). Repeatability (or relative standard deviation) between runs were calculated (n = 3) at the respective Community maximum residue limits (MRL) and 0.5 x MRL with the exception of honey since no European MRL exists at present. Results were determined as 4.3% (200 microg kg(-1)) and 2.8% (100 microg kg(-1)) in milk, 13.3% (40 microg kg(-1)) and 9.5% (20 microg kg(-1)) in honey, 7.1% (1000 microg kg(-1)) and 7.6% (500 microg kg(-1)) in kidney and 7.1% (500 microg kg(-1)) and 11% (250 microg kg(-1)) in muscle.  相似文献   

6.
A method for the simultaneous determination of eight beta-lactam antibiotics (nafcillin, cloxacillin, oxacillin, dicloxacillin, ampicillin, amoxicillin, and penicillin G) in fortified milk samples of different origins has been proposed by using CZE with diode-array detection (CZE-DAD). Optimum separation was obtained on a 64.5 cm x 75 microm bubble cell capillary using 175 mM Tris buffer with 20% ethanol at pH 8.0. Methylparaben has been used as an internal standard (IS). Taking into account the lack of sensitivity of the UV-Vis detection, a solvent extraction/SPE method was applied for off-line preconcentration and sample cleanup, and also an on-line preconcentration methodology, such as large-volume sample stacking (LVSS) with polarity switching, was developed, providing LODs ranging from 2 to 10 microg/L. The method permits the quantification of these residues below the levels established in milk by the EU Regulation. Satisfactory recoveries ranging from 86 to 93% were also obtained in milk samples of different origins.  相似文献   

7.
Meyer UJ  Zhi ZL  Loomans E  Spener F  Meusel M 《The Analyst》1999,124(11):1605-1610
A fully automated stand-alone flow injection immunoanalysis (FIIA) device for the determination of cephalexin in milk is developed with a main focus on the investigation of the influence of the sample matrix. The system is based on principles of flow-through immunoassays and on sequential addition of the assay components to an immunoreactor. Protein G is immobilised on the surface of the immunoreactor serving as affinity matrix for the polyclonal anti-cephalexin antibodies. A cephalexin-alkaline phosphatase conjugate is mixed with the analyte-containing sample and binds in a competitve manner to the corresponding antibodies in the immunoreactor. After substrate addition enzymatically generated p-aminophenol is detected at a carbon electrode at +150 mV vs. Ag/AgCl. One assay cycle takes 16 min including regeneration of the immunoreactor. The large excess of protein G allows for more than 150 regenerations without significant loss of signal height. Due to the high specificity of the anti-cephalexin antibodies, other beta-lactam antibiotics like penicillin, amoxicillin and cloxacillin do not interfere in the measurements, even when added at 10 mg l-1. To deactivate alkaline phosphatase present in milk, samples are heat-treated for 3 min prior to measurements. Cephalexin recoveries from two milk samples are 90 and 110%. The detection limit in milk is 1 microgram l-1 (mean relative standard deviation of 3%), less than the maximum residue level of 4 micrograms per kg milk fixed for some beta-lactam antibiotics in the European Union. The device is suitable for fast quantitative data generation from consecutively measured samples and thus adds to analytical screening methods.  相似文献   

8.
The stability of five major beta-lactam antibiotics (amoxicillin, ampicillin, cloxacillin, oxacillin, and penicillin G) in fortified milk and in milk extracts prepared for LC-ESIMS/MS analysis was studied at varying cold temperatures (4, -20, and -76 degrees C). Storage of milk samples at 4 degrees C resulted in measurable losses of all beta-lactams after 6 days (>50% in most cases). Slow degradation of penicillin G, cloxacillin, and oxacillin was observed in milk stored at -20 degrees C, but no losses were recorded at -76 degrees C over 4 weeks. All antibiotics showed good stability at all temperature tested in milk extracts prepared for LC-ESIMS/MS analysis. The results of this study emphasize adherence to adequate sample handling and storage protocols as to reflect residue levels at the time of sample submission.  相似文献   

9.
Cui S  Li J  Hu C  Jin S  Ma Y 《Journal of AOAC International》2007,90(4):1128-1132
With the rapid growth of the dairy industry and the establishment of strict antimicrobial residue limits in the People's Republic of China's (PRC) milk supply, a beta-lactamase product known as "antimicrobial destroyer" was introduced into dairy production without regulatory review. We developed a method for detecting this product in milk samples based on a modified cylinder plate method. The presence of beta-lactamase is defined as a difference between the inhibitory zones of the test samples (supplemented with 25 microg/mL sulbactam plus 0.5 microg/mL penicillin G) and control samples (supplemented only with 0.5 microg/mL penicillin G) > or = 3 mm. Using this method, 77 individually packaged milk samples were randomly collected from 5 retail stores in 3 cities over a 4-month period (May to August 2006). Of the 77 samples, 49 were found to be beta-lactamase-positive. In 2 undiluted milk samples showing extremely high beta-lactamase activity, 25 microg/mL sulbactam could not inhibit penicillin G activity. Because there is a lack of safety data on beta-lactamases in milk products, these data indicated a potentially serious safety concern for the dairy industry in the PRC.  相似文献   

10.
A sensitive and reliable method using capillary zone electrophoresis with UV-diode array detection (CZE-DAD) has been developed and validated for trace determination of beta-lactam antibiotics in waste, well and river water matrices. Due to the lack of sensitivity of the UV-vis detection, a solvent extraction/solid-phase extraction (SPE) method applied for off-line preconcentration and cleanup of water samples, in combination with an on-line preconcentration methodology named large volume sample stacking (LVSS) have been applied. The analytes included nafcillin, dicloxacillin, cloxacillin, oxacillin, ampicillin, penicillin G and amoxicillin. Average recoveries for water samples fortified with the studied beta-lactams at different concentration levels (1.0, 2.0 and 4.0 microg/L) were ranging between 94 and 99%, with relative standard deviations (RSDs) lower than 10%. The precision, calculated as intra-day and inter-day standard deviations fell within acceptable ranges (3.3-7.2%). The limits of detection were estimated to range between 0.08 and 0.80 microgL(-1) for the studied compounds. All the samples analyzed were negative for all the analytes at these levels of concentration and the method showed its usefulness for the detection of these widely applied beta-lactam antibiotics in different kinds of waters.  相似文献   

11.
LacTek tests are competitive enzyme-linked immunosorbent assays intended for rapid detection of antimicrobial residues in bovine milk. In this study, the LacTek test protocol was modified for use with extracts of bovine tissue to detect beta-lactam, tetracycline, and sulfamethazine residues. Test performance characteristics--precision, accuracy, ruggedness, practicability, and analytical specificity and sensitivity--were investigated. Results suggest that LacTek tests can be easily adapted to detect antimicrobial residues in extracts of lean ground beef. However, positive samples may not contain residues at violative concentrations (i.e., Canadian maximum residue limits), and therefore, additional analysis would be required for final confirmation and quantitation (e.g., chromatography).  相似文献   

12.
Parallux, a solid-phase fluorescence immunoassay (SPFIA) developed for antibiotic residue detection in milk, was used for analysis of bovine and porcine kidney tissue. Four tetracyclines, 2 broad-spectrum cephalosporins, 3 beta-lactam antibiotics, and cephapirin were detected in one run after minimal sample preparation. This commercially available test system is designed as cartridges, each with a combination of 1-4 tests. One cartridge can be used to detect 4 analytes in the same sample, or 1 or 2 analytes in different samples. The cartridge with the combination tetracyclines-ceftiofur-penicillin-cephapirin was selected because tetracyclines, beta-lactam antibiotics as well as cephalosporins, are registered for oral or parenteral use in bovines and pigs in Europe. The test is qualitative and is recommended only for screening. Tetracycline, oxytetracycline, chlortetracycline, and doxycycline were easily detected at 300 ppb with the tetracyclines channel; ceftiofur at 1000 ppb and cefquinome at 200 ppb with the ceftiofur channel; penicillin G, ampicillin, and amoxicillin at 50 ppb with the penicillin channel; and cephapirin at 100 ppb with the cephapirin channel. These levels are equal to or lower than the corresponding maximal residue limits in kidney tissue. Cephalexin was not detected. The SPFIA test can be used as an alternative to classical inhibition tests and for post-screening inhibitor- positive kidneys, because it detects 3 specific groups of antibiotics, which enables selection of specific confirmatory methods for identification and quantification.  相似文献   

13.
A multilaboratory trial for determining ceftiofur-related residues in bovine and swine kidney and muscle, and bovine milk was conducted following regulatory guidelines of the U.S. Food and Drug Administration, Center for Veterinary Medicine. The methods convert all desfuroylceftiofur-related residues containing the intact beta-lactam ring to desfuroylceftiofur acetamide to establish ceftiofur residues in tissues. Four laboratories analyzed 5 sets of samples for each tissue. Each sample set consisted of a control/blank sample and 3 control samples fortified with ceftiofur at 0.5 Rm, Rm, and 2 Rm, respectively, where Rm is the U.S. tolerance assigned for ceftiofur residue in each tissue/matrix: 0.100 microg/mL for milk, 8.0 microg/g for kidney (both species), 1.0 microg/g for bovine muscle, and 2.0 microg/g for swine muscle. Each sample set also contained 2 samples of incurred-residue tissues (one > Rm and one < Rm) from animals treated with ceftiofur hydrochloride. All laboratories completed the method trial after a familiarization phase and test of system suitability in which they demonstrated > 80% recovery in pretrial fortified test samples. Results showed that the methods met all acceptable performance criteria for recovery, accuracy, and precision. Although sample preparation was easy, solid-phase extraction cartridge performance must be carefully evaluated before samples are processed. The liquid chromatography detection system was easily set up; however, the elution profile may require slight modifications. The procedures could clearly differentiate between violative (> Rm) and nonviolative (< Rm) ceftiofur residues. Participating laboratories found the procedures suitable for ceftiofur residue determination.  相似文献   

14.
The Charm Safe-Level beta-Lactam Test was evaluated by a U.S. Food and Drug Administration (FDA) test protocol administered by the AOAC-Research Institute. The sensitivity and selectivity of the test were evaluated with >800 negative raw commingled and drug-fortified milk samples by the manufacturer and an independent laboratory. Probit analysis by the independent laboratory determined the following 90% positive levels with 95% confidence: amoxicillin, 5.6 ppb; ampicillin, 8.5 ppb; cephapirin, 13.7 ppb; ceftiofur, 46.2 ppb; and penicillin G, 3.6 ppb. These values were within a range of +/- 20% of the manufacturer's data. Selection of negative samples met confidence specifications. Ruggedness parameters were studied and defined, and the stability of frozen milk was verified. There were no interferences from somatic cells (1,000,000 somatic cell count/mL) or bacteria (300,000 colony-forming units/mL), or from 27 other non-beta-lactam animal drugs. Test performance with raw milk samples containing incurred penicillin, ampicillin, and amoxicillin was consistent with the dose responses determined with fortified milk samples. Incurred cephalosporin in raw milk samples was detected at lower levels than was cephalosporin in fortified milk samples, presumably because of the presence of metabolite, as verified by other test methods. Quality control data support consistency in manufacture between batches and the stability of refrigerated test reagents for up to 1 year. Successful fulfillment of these criteria led to FDA certification of the test when used with a reader in U.S. milk testing programs.  相似文献   

15.
崔晓亮  邵兵  赵榕  孟娟  涂晓明 《色谱》2006,24(3):213-217
采用超高效液相色谱-串联电喷雾四极杆质谱(负离子模式)在多反应监测(MRM)模式下测定了牛奶中12种糖皮质激素的残留。试样中加入pH 5.20的醋酸盐缓冲溶液和甲醇,超声提取,以去除部分蛋白质,然后用正己烷脱脂,依次经HLB柱、硅胶柱和氨基柱等固相萃取柱浓缩和净化后,通过Waters ACQUITY UPLCTM BEH C18色谱柱分离,以甲醇和含0.1%甲酸的水为流动相进行梯度洗脱。在超高效液相色谱-质谱分析过程中以保留时间和离子对(母离子和两个碎片离子)信息比较进行定性,以母离子和响应值高的碎片离子进行定量。该法的检出限为0.02~0.38 μg/kg,最低定量限为0.07~1.27 μg/kg。添加水平为2 μg/kg和0.4 μg/kg时,12种糖皮质激素的加标回收率为69.3%~94.3%,相对标准偏差为3.5%~16.7%。  相似文献   

16.
An optical biosensor was used to develop both direct and sandwich immunoassays for the detection of proteins from milk, egg, hazelnut, peanut, shellfish, and sesame in food samples. Affinity-purified polyclonal antibodies raised against the proteins were immobilized on the biosensor chip. Food samples were injected and the proteins that bound to the antibodies on the surface were detected by a shift in the resonance angle. By adding a second antibody in a sandwich assay, matrix effects could be overcome and the sensitivity and selectivity enhanced. Detection of allergen levels down to 1-12.5 microg/g in food samples was demonstrated for the various assays. Good agreement of results was also obtained from parallel analysis with alternative immunoassays, including rocket immunoelectrophoresis, enzyme immunoassay, and immunoblotting. The present study demonstrates that the sensitivity of the described biosensor technique is comparable to the most sensitive enzymed-linked immunosorbent assays.  相似文献   

17.
High-performance liquid chromatography with diode-array detection (HPLC-DAD) was optimised and validated for the determination of tetracyclines in bovine milk and tissues. Milk and tissue samples were extracted and purified using a solid-phase extraction HLB Oasis cartridge and analysed using HPLC-DAD set at 365 nm. The analyses were carried out using the mobile phase of 0.01 M oxalic acid-acetonitrile-methanol (60:25:15, v/v/v) on a C8 column (250 x 4.6 mm I.D., 5 microm). Recoveries of tetracyclines from spiked samples at the three concentrations (0.5, 1 and 1.5) of the maximum residues limits (corresponding to 100 microg/kg for milk and the muscle) were higher than 81.1% in milk and 83.2% in muscle. The method was successfully validated for bovine milk and muscle in compliance with requirements set by draft SANCO/ 1805/ 2000 European Decision. The decision limit (CCalpha) was in the range 113.2-127.2 microg/kg and 107.7-129.9 micro/kg for all compounds in milk and muscle, respectively. The detection capability (CCbeta) was in the range 117.2-131.3 microg/kg and 114.9-133.1 microg/kg for all compounds in milk and muscle, respectively.  相似文献   

18.
Sulfonamides are commonly used for prophylactic or therapeutic purposes in veterinary medicine. A maximum residue limit (MRL) for sulfonamides has been set at 100 microg/kg in milk and muscle. A multisulfonamide antibody was used for the development of 2 different Biacore protocols, one for the screening of milk samples, the other for muscle samples. Two different Biacore systems were used: Biacore X system (milk protocol), which is considered a research and development apparatus, and Biacore 3000 system (muscle protocol), which is a completely automated system used for high-throughput screening. This report describes the validation of semiquantitative immunological methods according to the European Decision 2002/657/EC "concerning the performance of analytical methods." The different performance characteristics (detection capability CCbeta, specificity/selectivity, precision, stability, and applicability) were determined in relation to the European Union MRL of 100 microg/kg for sulfonamides. The applicability of the method to porcine, bovine, and poultry muscle was studied. The detection capabilities CCbeta were calculated to be 40 microg/L in milk and 60 microg/kg in porcine, bovine, and poultry muscles. Eight different sulfonamides, of which 3 (sulfamethazine, sulfamerazine, and sulfadiazine) are authorized in France, were detected simultaneously, at or below the MRL level, with both Biacore systems.  相似文献   

19.
A high-performance liquid chromatographic method was developed for the determination of five penicillins: penicillin G (PENG), penicillin V (PENV), oxacillin (OX), cloxacillin (CLO), and dicloxacillin (DICLO), in bovine muscle. Samples were macerated with a mixture of H(2)O/CH(3)CN (1:1) and purified using RP-8 Adsorbex SPE cartridges after centrifugation, with mean recovery from spiked samples higher than 89%. The separation of the examined penicillins was achieved on an analytical column, an Inertsil C8 5 microm, 250x4 mm(2), at ambient temperature. The mobile phase consisted of 0.1% TFA/ACN 50:50 v/v delivered isocratically at a flow rate of 1.1 mL/min. Analytes were monitored at 240 nm. The procedure was validated according to the European Union Decision 2002/657/EC by means of selectivity, stability, decision limit, detection capability, accuracy, and precision. Method's LOQ values achieved were 54 microg/kg for PENG and DICLO, 46 microg/kg for PENV, 16 microg/kg for OX, and 43 microg/kg for DICLO. The detection capabilities (CC(beta)) were 73.6 microg/kg for PENG, 29.1 microg/kg for PENV, 350.6 microg/kg for OX, 379.9 microg/kg for CLO, and 355.8 microg/kg for DICLO. The method was applied to various samples from the local market. Two penicillins were identified by photodiode array (PDA) detection and quantified.  相似文献   

20.
A liquid chromatographic method for the determination of closantel residues in milk and tissues is developed and validated. An acetonitrile-acetone solution (80:20, v/v) is used for the extraction of closantel residues from milk and animal tissues, and the extract is purified by solid-phase extraction with Oasis MAX cartridges and a mixture of formic acid-acetonitrile (5:95, v/v) as the elution solution. A C(18) bonded silica column is used for chromatographic separation. The mobile phase consists of acetonitrile-water (85:15, v/v) containing 0.05% triethylamine at pH 2.5, adjusted with phosphoric acid with the flow-rate set at 1.0 mL/min. Using the fluorescence emission of closantel at lambda(ex) = 335 nm and lambda(ex) = 510 nm, the calibration curve is linear, with a correlation coefficient of 0.9999 over the concentration range of 10-5000 microg/kg for the tissue sample and 10-5000 microg/L for the milk sample. The detection limit (s/n = 3) is 3 microg/kg for tissue sample and 3 microg/L for milk sample. The intra- and inter-day repeatabilities are between 3.35-7.66% and 4.04-8.67%, respectively. The proposed method enables the quantitative determination of closantel residues at levels as low as 10 microg/kg in animal tissue samples and 10 microg/L in milk samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号