首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
固相萃取-高效液相色谱法测定环境水样中的三嗪类化合物   总被引:17,自引:0,他引:17  
李竺  陈玲  郜洪文  董丽娴  赵建夫 《色谱》2006,24(3):267-270
建立了固相萃取-高效液相色谱法(SPE-HPLC)测定地表水中三嗪类化合物的方法。考察了4种不同固相萃取柱对三嗪类化合物的吸附效果,最终选择ENVI-18固相萃取柱用于萃取地表水中的三嗪类化合物;系统研究了环境水样中三嗪类化合物的最佳固相萃取条件,选择洗脱溶剂为甲醇,洗脱溶剂用量5 mL,水样在萃取前不需要添加甲醇,不调节pH值。测定了方法的检测限,结果表明,扑草净、莠去津、西玛津、脱乙基莠去津、羟基化莠去津和脱异丙基莠去津的最低检测限依次为0.14 μg/L,0.12 μg/L,0.08 μg/L,0.08 μg/L,0.10 μg/L和0.18 μg/L。将该法应用于实际环境水样的分析测定,结果表明某湖水中扑草净的含量为(9.33±0.27) μg/L,某江水中莠去津和扑草净的含量分别为(5.28±0.43) μg/L和(7.12±0.54) μg/L。  相似文献   

2.
The need for highly reliable methods for the determination of trace and ultratrace elements has been recognized in analytical chemistry and environmental science. A simple and powerful microextraction technique was used for the detection of the lead ultratrace amounts in water samples using the dispersive liquid-liquid microextraction (DLLME), followed by the electrothermal atomic absorption spectrometry (ET AAS). In this microextraction technique, a mixture of 0.50 mL acetone (disperser solvent), containing 35 microL carbon tetrachloride (extraction solvent) and 5 microL diethyldithiophosphoric acid (chelating agent), was rapidly injected by syringe into the 5.00 mL water sample, spiked with lead. In this process, the lead ions reacted with the chelating agent and were extracted into the fine droplets of CCl(4). After centrifugation (2 min at 5000 rpm), the fine CCl4 droplets were sedimented at the bottom of the conical test tube (25+/-1 microL). Then, 20 microL from the sedimented phase, containing the enriched analyte, was determined by ET AAS. The next step was the optimization of various experimental conditions, affecting DLLME, such as the type and the volume of the extraction solvent, the type and the volume of the disperser solvent, the extraction time, the salt effect, pH and the chelating agent amount. Moreover, the effect of the interfering ions on the analytes recovery was also investigated. Under the optimum conditions, the enrichment factor of 150 was obtained from only a 5.00 mL water sample. The calibration graph was linear in the range of 0.05-1 microg L(-1) with the detection limit of 0.02 microg L(-1). The relative standard deviation (R.S.D.) for seven replicate measurements of 0.50 microg L(-1) of lead was 2.5%. The relative lead recoveries in mineral, tap, well and sea water samples at the spiking level of 0.20 and 0.40 microg L(-1) varied from 93.5 to 105.0. The characteristics of the proposed method were compared with the cloud point extraction (CPE), the liquid-liquid extraction, the solid phase extraction (SPE), the on-line solid phase extraction (SPE) and the co-precipitation, based on bibliographic data. The main DLLME advantages combined with ET AAS were simplicity of operation, rapidity, low cost, high-enrichment factor, good repeatability, low consumption of extraction solvent, requiring a low sample volume (5.00 mL).  相似文献   

3.
A novel and simple flow injection chemiluminescence method is reported for the determination of simetryn, a common herbicide. The method is based on the direct oxidation of luminol by the photoproducts of the simetryn in alkaline medium in the absence of catalyst/oxidant. The linear concentration range was 0.01 - 2 microg mL(-1) simetryn with a correlation coefficient (r(2)) of 0.9997 and relative standard deviations (RSD; n = 4) in the range of 0.9 - 2.3%. The limit of detection (S/N = 3) was 7.5 ng mL(-1) with a sample throughput of 100 h(-1). The proposed method has been applied to determine simetryn in natural waters using Sep-Pak C(18) cartridges for solid phase extraction (SPE) procedure. The recoveries were in the range of 97 +/- 1 to 104 +/- 2%. The mechanism of chemiluminescence reaction has also been discussed briefly.  相似文献   

4.
A new method for determination of volatile terpenoids in wine is proposed. An off-line solid phase extraction—gas chromatographic method has been used for the determination. The influence of several extraction variables was studied, including the solid phase employed (C-18 versus divinylbenzene-based), eluting solvent (n-pentane, dichloromethane, ethanol and methanol), volume of eluting solvent (1-4 ml) and drying time (0-20 min). Complete recovery of volatile terpenoids from several kinds of wines was obtained under the optimized conditions.  相似文献   

5.
固相萃取-离子色谱法测定地下水中痕量高氯酸根离子   总被引:1,自引:0,他引:1  
Ye L  You H  Yao J  Su H 《色谱》2012,30(1):76-79
建立了测定地下水中痕量高氯酸根(ClO~4)的固相萃取-离子色谱(SPE-IC)分析方法。0.7 L水样经预处理降低主要干扰离子Cl~、CO2~3和SO2~4的干扰后,使用Cleanert PWAX弱阴离子交换固相萃取小柱对地下水中痕量(μg/L级)的ClO~4进行富集,用6 mL 1%NaOH溶液洗脱,富集液经0.45 μm水膜过滤后,用IonPac AS20阴离子分离柱、50 μL进样环、40 mmol/L KOH溶液淋洗、抑制电导检测分离分析。结果表明,地下水样品中ClO~4的方法检出限和测定下限分别为0.15 μg/L和0.60 μg/L,进样质量浓度在1~15 μg/L范围内有很好的线性关系,线性相关系数为0.9992,回收率为99.7%~100.5%;该方法经济有效,可用于地下水中痕量ClO~4的检测。利用该方法测定了哈尔滨周边部分地区地下水中ClO~4浓度,检测结果与离子色谱-质谱联用法的检测结果的相对误差为1.85%~9.24%。  相似文献   

6.
A method for the simultaneous determination of seven preservatives - sorbic acid, benzoic acid, and p-hydroxybenzoic acid ethyl, isopropyl, propyl, isobutyl, and butyl esters - in beverages, vinegar, aqueous sauces, and quasi-drug drinks has been developed using the stir-bar sorptive extraction technique then thermal desorption GC-MS analysis. The extraction conditions - pH, sample volume, extraction temperature, salt addition, and extraction time - were examined. d5-Benzoic acid and p-hydroxybenzoic acid sec-butyl ester were added as surrogate internal standards to compensate for the effect of sample matrix and coexisting analytes on the sorptive extraction. The linearity of the method was good over the concentration range from 1 to 1000 microg mL(-1) for sorbic acid, 10-1000 microg mL(-1) for benzoic acid, and 0.1-100 microg mL(-1) for p-hydroxybenzoic acid ethyl, isopropyl, propyl, isobutyl, and butyl esters, and the correlation coefficients were higher than 0.9984. The limit of detection ranged from 0.015 to 3.3 microg mL(-1). The recoveries (95-105%) and precision (RSD: 0.86-6.0%) of the method were examined by analyzing a sparkling soft drink, white wine, red wine, balsamic vinegar, soy sauce, and quasi-drug drink samples fortified at the 5 to 50 microg mL(-1) level.  相似文献   

7.
The simultaneous determination of amphetamine and methadone was carried out by magnetic graphene oxide nanoparticles, a magnetic solid‐phase extraction adsorbent, as a new sample treatment technique. The main factors (the amounts of sample volume, amount of adsorbent, type and amount of extraction organic solvent, time of extraction and desorption, pH, the ionic strength of extraction medium, and agitation rate) influencing the extraction efficiency were investigated and optimized. Under the optimized conditions, good linearity was observed in the range of 100–1500 ng/mL for amphetamine and 100–1000 ng/mL for methadone. The method was evaluated for determination of AM and methadone in positive urine samples, satisfactory results were obtained, therefore magnetic solid‐phase extraction can be applied as a novel method for the determination of drugs of abuse in forensic laboratories.  相似文献   

8.
A novel method using a micro-column packed with active alumina as solid phase was proposed for separation of trace lithium from uranium compounds prior to determination. The method is based on a preliminary chromatographic separation of the total amount of uranium. This separation involves passing the solution containing sodium carbonate through active alumina and then eluting the trace lithium retained by the solid phase with a solution of sulfuric acid. Two modes, off-line and on-line micro-column preconcentration, were performed. In conjunction with atomic absorption spectrometry, this on-line preconcentration technique allows a determination of lithium at 10(-9) level. Both off-line and on-line mode operation conditions were investigated in separation and determination of trace lithium by micro-column method (length of column bed, flow rate, etc.). The adsorption capacity of activated alumina was found to be 343 microg g(-1) for lithium. Under the optimal operation condition, the detection limit (DL) of on-line preconcentration corresponding to three times the standard deviation of the blank (S/N = 3) was found to be 1.3 ng mL(-1) and the RSD of this method is 3.32% (n = 5). The on-line calibration graph was linear over the range 20 - 200 ng mL(-1). A good preconcentration factor 820 was achieved by experiment under the on-line mode. The developed method was applied to the analysis of trace lithium in nuclear grade uranium compounds.  相似文献   

9.
A new chromogenic reagent, 5-(2-hydroxy-5-nitrophenylazo)thiorhodanine (HNATR) was synthesized. A highly sensitive, selective and rapid method for the determination microg l(-1) level of Au(III) based on the rapid reaction of Au(III) with HNATR and the solid phase extraction of the colored complex with a reversed phase polymer-based C(18) cartridge have been developed. The HNATR reacted with Au(III) to form a red complex of a molar ratio 1:2 (Au(III) to HNATR) in the presence of 0.05 - 0.5 mol l(-1) of phosphoric acid solution and emulsifier-OP medium. This complex was enriched by the solid phase extraction with a polymer-based C(18) cartridge. The enrichment factor of 100 was achieved. The molar absorptivity of the complex is 1.37 x 10(5) l mol(-1) cm(-1) at 520 nm in the measured solution. The system obeys Beer's law in the range of 0.01 - 3 microg ml(-1). The relative standard deviation for eleven replicates sample of 0.5 microg l(-1) level is 2.18%. The detection limit, based on the three times of standard deviation is 0.02 microg l(-1) in the original sample. This method was applied to the determination of gold in water and ore with good results.  相似文献   

10.
A new, simple and sensitive kinetic spectrophotometric method with no need for removing of interfering substances is proposed for the determination of thiocyanate ion in biological and water samples. The procedure is based on the inhibiting effect of thiocyanate on the sodium periodate-potassium bromide-meta cresol purple (MCP) system in acidic media. The induction period of the reaction is proportional to the SCN- concentration. The decolorization of meta cresol purple by the reaction products was used to monitor the reaction spectrophotometrically at 525 nm. Under optimum conditions, thiocyanate can be determined in the range of 0.02-0.8 microg ml(-1) with a 3sigma detection limit of 5 ng ml(-1). The relative standard deviations for 10 replicate determinations of 0.060, 0.10 and 0.50 microg ml(-1) thiocyanate are 3.7, 2.4 and 1.0%, respectively. This method has been successfully used to the determination of thiocyanate content in smokers and non-smokers saliva and spiked water sample.  相似文献   

11.
A novel method for the non-derivatization liquid chromatographic determination of streptomycin (STR) and dihydrostreptomycin (DHSTR) was developed and validated based on evaporative light scattering detection (ELSD). Utilizing a ThermoHypersil BetaBasic C18 analytical column, evaporation temperature of 50 degrees C and pressure of nebulizing gas (nitrogen) of 3.5 bar, the optimized mobile phase was 1.25 mL L(-1) TFA aqueous solution, in an isocratic mode at a rate of 1.0 mL min(-1). STR was eluted at 5.6 min and DHSTR at 7.8 min with a resolution of 4.4. Linear calibration curves were obtained from 2 to 120 microg mL(-1) (r > 0.9990) for STR and 2-75 microg mL(-1) (r > 0.9994) for DHSTR, with a LOD equal to 0.7 and 0.5 microg mL(-1), respectively. The developed method was applied for the assay of STR and DHSTR (sulfate) in pharmaceutical raw materials and formulations, while the simultaneous direct determination of sulfate was feasible (tR = 2.5 min, LOD = 1.4 microg mL(-1), double logarithmic calibration curve in the range of 4-50 microg mL(-1), r > 0.9998). Modified isocratic mobile phase (H2O-ACN, 90:10, v/v, containing 1.25 mL L(-1) TFA), was used for the determination of streptomycin B impurity in STR sulfate raw material and a gradient mobile phase (H2O-ACN containing TFA) was used for the determination of DHSTR in the presence of penicillinG procaine. The developed method was also applied for the assay of commercial formulations (STR powder and DHSTR injection solution and suspension) (%recovery 98-102, %RSD < 1.3, n = 3 x 3), for the determination of STR in bacteria culture medium (%recovery 99.6, %RSD = 0.8, n = 3 x 3), and for the determination of DHSTR in human plasma (2.0-23.0 microg mL(-1)) after solid phase extraction using carboxylate cartridges (%recovery 98.4-101.8, %RSD = 3.2, n = 3 x 3).  相似文献   

12.
A highly selective, sensitive and rapid method for the determination of trace amounts of inorganic mercury based on the reaction of Hg (II) with 6-mercaptopurine and the solid phase extraction of the complex on C18 membrane disks was developed. The 6-mercaptopurine selectively reacts with Hg (II) to form a complex in the pH range of 5-8. This complex was preconcentrated by solid phase extraction with C18 disks. An enrichment factor of 100 was achieved. The molar absorptivity of the complex is 0.26 x 10(-6) L. mol(-1) cm(-1) measured at 315 nm. The Beer's law is obeyed in the concentration range of 0.002-0.048 microg mL(-1). The relative standard deviation for eleven-replicated measurement of 0.04 microg mL(-1) is 1.5 %. The detection limit is 0.001 microg mL(-1) in the water samples. The advantage of the method is that the determination of Hg (II) is free from interference of almost all the cations and anions found in environment and wastewater samples. The determination of Hg (II) in water samples of different origins and marine sediment were carried out by the present method and cold vapor atomic absorption spectrometry (CVAAS). Also the method's accuracy was investigated by using SRM 2709. The obtained results by the present procedure were in good agreement with those of the CVAAS and certified value, so that the applicability of the proposed method was confirmed for the real samples.  相似文献   

13.
A new method involving matrix solid-phase dispersion (MSPD) extraction and hydrophilic interaction ultra-high-pressure liquid chromatography (HILIC-UHPLC) with photodiode array detection was developed for the determination of carbadox and olaquindox in feed. Separation of carbadox and olaquindox was achieved within 1 min on the 1.7 microm Acquity UPLC BEH HILIC column by using isocratic elution with a mobile phase consisting of 10 mmol L(-1) ammonium acetate in acetonitrile-water (95:5, v/v) at a flow rate of 0.5 mL min(-1). Optimization of MSPD extraction parameters, such as type of solid sorbent and elution solvent were carried out. Optimal conditions selected for MSPD extraction were: 0.25 g of feed sample, 0.5 g of octadecylsilica as solid sorbent and 10 mL of acetonitrile-methanol (8:2, v/v) as eluting solvent. Both analytes provided average recoveries from spiked feed samples ranging from 89.1 to 98.4% with relative standard deviations less than 10%. Obtained performance characteristics are comparable to those achieved by liquid-liquid extraction-HPLC with the advantages of being simpler and significantly faster.  相似文献   

14.
A new chromogenic reagent, 2-(2-quinolylazo)-5-diethylaminophenol (QADEAP), was synthesized. A sensitive, selective and rapid method has been developed for the determination of microg/L level silver ion based on the rapid reaction of silver(l) with QADEAP and the solid phase extraction of the colored chelate with C18 cartridge. The QADEAP reacts with Ag(l) to form a violet chelate of a molar ratio 1:2 (silver to QADEAP) in pH 3.5-8.0. This chelate was prconcentrated by solid phase extraction with C18 cartridge. An enrichment factor of 100 was achieved. The molar absorptivity of the chelate is 1.30 x 10(5) L mol(-1) cm(-1) at 590 nm in measured solution. Beer's law is obeyed in the range of 0.01-0.6 microg/ml. The relative standard deviation for eleven replicate samples of 0.01 microg/ml is 1.15%. The detection limit is 0.02 microg/L in the original samples. This method was applied to the determination of microg/L level silver ion in water with good results.  相似文献   

15.
In this work, a novel, rapid, and simple analytical method was proposed for the detection of parabens in milk sample by gas chromatography coupled with mass spectrometry. At the same time, milk sample was pretreated by magnetic solid phase extraction, which detected up to five parabens. A series of important parameters of magnetic solid phase extraction were investigated and optimized, such as pH value of loading buffer, amount of material, adsorption time, ionic strength, eluting solvents, and eluting time. Under the optimized conditions, the corresponding values were more than 0.9991, limits of detection and the limit of quantification were 0.1 and 0.5 ng/mL, respectively. In addition, the recoveries were achieved in range of 95–105%, the liner range were within 0.1–600 ng/mL, and the relative standard deviations were even lower than 5%.  相似文献   

16.
Dynamic liquid-phase microextraction (dLPME) using an ionic liquid as acceptor phase is proposed for the determination of six non-steroidal anti-inflammatory drugs (NSAIDs) in human urine samples for the first time. The extraction is carried out in a simple and automatic flow configuration. The chemical affinity between the extractant (1-butyl-3-methylimidazolium hexafluorophosphate) and the analytes permits a selective isolation of the drugs from the sample matrix allowing also their preconcentration. The whole analytical method has been optimized taking into account all the chemical, physical and hydrodynamic variables. The proposed method is a valuable alternative for the analysis of these drugs in urine within the concentration range 0.1-10 microg mL(-1), allowing their determination at therapeutic and toxic levels. Limits of detection were in the range from 38 ng mL(-1) (indomethacin) to 70 ng mL(-1) (naproxen). The repeatability of the proposed method expressed as RSD (n=5) varied between 2.1% (flurbiprofen) and 3.8% (tolmetin).  相似文献   

17.
以咖啡因作为模板分子,α-甲基丙烯酸为功能单体,乙二醇二甲基丙烯酸酯为交联剂,制备了咖啡因分子印迹聚合物(MIP)。与非印迹聚合物(NIP)相比,MIP对咖啡因具有更高的吸附容量和选择性,MIP和NIP对咖啡因的最大静态吸附量分别为28.1和16.5mg/g,相对选择因子为1.25。以咖啡因分子印迹聚合物为固相萃取填料,结合高效液相色谱(HPLC),建立了茶水中咖啡因浓度及人饮茶后血清中咖啡因浓度的检测方法。考察了洗脱剂种类和用量对咖啡因回收率的影响。当萃取柱依次以2mL水活化,水溶液上样,2mL水淋洗,6mL甲醇-乙酸(9∶1,V/V)洗脱,咖啡因在MIP固相萃取柱上的回收率达到97.5%,而在NIP柱上的回收率仅为54.9%。  相似文献   

18.
A simple methodology has been developed for the solid phase extraction of lead based on the adsorption of its diphenylthiocarbazone complex on an Amberlite XAD-1180 column. The effect of various parameters such as eluting agents, stability of the column, sample volume, interfering ions, etc. were studied in detail. The adsorbed complex could be eluted using acetone and the concentration of lead was determined using visible spectrophotometry at a wavelength maximum of 486nm. A detection limit of 3.5microgL(-1) could be achieved and the validity of the proposed method was checked in spiked tap water, well water and industrial wastewater samples. The relative standard deviation of the method was found to be 3.0%. The highest preconcentration factor attainable for quantitative recovery (>95%) of lead was 25 for a 250mL sample volume.  相似文献   

19.
The present paper reports on the application of modified multiwalled carbon nanotubes (MMWCNTs) as a new, easily prepared and stable solid sorbent for the preconcentration of trace Co(II) in aqueous solution. Multiwalled carbon nanotubes (MWCNTs) were oxidized with concentrated HNO(3) and modified with 1-(2-pyridylazo)-2-naphtol (PAN), and were then used as a solid phase for the preconcentration of Co(II). Factors influencing the sorption and desorption of Co(II) were investigated. Elution was carried out with 0.5 mol L(-1) HNO(3). The amount of eluted Co(II) was measured using flame atomic absorption spectrometry. The effects of the experimental parameters, including the sample pH, sample flow rate, eluent flow rate and eluent concentration, were investigated. The effect of coexisting ions showed no interference from most ions tested. The proposed method permitted a large enrichment factor (about 300). The precision of the method was 1.63% (for eight replicate determination of 0.5 microg mL(-1) of Co(II)) and the limit of detection was 0.55 ng mL(-1). The method was applied to the determination of Co(II) in water, biological and standard samples.  相似文献   

20.
Simultaneous dispersive liquid-liquid microextraction (DLLME) and derivatization combined with gas chromatography-electron-capture detection (GC-ECD) was used to determine chlorophenols (CPs) in water sample. In this derivatization/extraction method, 500 microL acetone (disperser solvent) containing 10.0 microL chlorobenzene (extraction solvent) and 50 microL acetic anhydride (derivatization reagent) was rapidly injected by syringe in 5.00 mL aqueous sample containing CPs (analytes) and K(2)CO(3) (0.5%, w/v). Within a few seconds the analytes derivatized and extracted at the same time. After centrifugation, 0.50 microL of sedimented phase containing enriched analytes was determined by GC-ECD. Some effective parameters on derivatization and extraction, such as extraction and disperser solvent type and their volume, amount of derivatization reagent, derivatization and extraction time, salt addition and amount of K(2)CO(3) were studied and optimized. Under the optimum conditions, enrichment factors and recoveries are in the range of 287-906 and 28.7-90.6%, respectively. The calibration graphs are linear in the range of 0.02-400 microg L(-1) and limit of detections (LODs) are in the range of 0.010-2.0 microg L(-1). The relative standard deviations (RSDs, for 200 microg L(-1) of MCPs, 100 microg L(-1) of DCPs, 4.00 microg L(-1) of TCPs, 2.00 microg L(-1) of TeCPs and PCP in water) with and without using internal standard are in the range of 0.6-4.7% (n=7) and 1.7-7.1% (n=7), respectively. The relative recoveries of well, tap and river water samples which have been spiked with different levels of CPs are 91.6-104.7, 80.8-117.9 and 83.3-101.3%, respectively. The obtained results show that simultaneous DLLME and derivatization combined with GC-ECD is a fast simple method for the determination of CPs in water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号