首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Stevia rebaudiana extracts and plant materials are increasingly used as natural sweeteners. Polyphenolic and stevioside compounds contained in S. rebaudiana extracts were separated by comprehensive LC. A polyamine column operated in normal phase mode was used for the first dimension separation (D1), and a UHPLC C18 column operated in reversed phase mode was used for the second dimension separation (D2). The sub-2 μm column (2.1 mm × 30 mm, maintained at 70°C) and the UHPLC pump employed for D2 elution allowed a separation/cycle time of 20 s, with a backpressure oscillating between 805 and 922 bar at 3.4 mL/min. The reduced D2 cycle time allowed 3-12 D2 samplings for each peak eluted by D1. Polyphenolic and stevioside compounds were identified by combining the information coming from the position of the compounds in the 2D plot and UV spectra with that of reference materials.  相似文献   

2.
A comprehensive 2-D LC x LC system was developed for the separation of phenolic and flavone antioxidants, using a PEG-silica column in the first dimension and a C(18) column with porous-shell particles or a monolithic column in the second dimension. Combination of PEG and C18 or C8 stationary phase chemistries provide low selectivity correlations between the first dimension and the second dimension separation systems. This was evidenced by large differences in structural contributions to the retention by -COOH, -OH and other substituents on the basic phenol or flavone structure. Superficially porous columns with fused core particles or monolithic columns improve the resolution and speed of second dimension separation in comparison to a fully porous particle C(18) column. Increased peak capacity and high orthogonality in different 2-D setups was achieved by using gradients with matching profiles running in parallel in the two dimensions over the whole 2-D separation time range. Multi-dimensional set-up combining the LC x LC separation on-line with UV and multi-channel coulometric detection and off-line with MS/MS technique allowed positive peak identification. The Coularray software compensates for the effects of the baseline drift during the gradient elution and is compatible with parallel gradient comprehensive LC x LC technique. Furthermore, it provides significant improvement in the sensitivity and selectivity of detection in comparison to both UV and MS detection. The utility of these systems has been demonstrated in the analysis of beer samples.  相似文献   

3.
4.
张政  唐涛  杨三东  孙元社  李彤  张维冰 《色谱》2017,35(5):526-532
基于蛋白质的尺寸及带电性质,将凝胶过滤色谱(GFC)与离子交换色谱(IEC)两种分离模式结合,采用双捕集柱接口构建了GFC/2×IEC二维液相色谱(2-D LC)分离系统,同时考虑离子交换色谱分离蛋白质对等电点范围的限制,进一步结合中心切割平行柱的方法实现对蛋白质的全二维分离。为与后续蛋白质在线酶解、多肽分离及质谱鉴定匹配,系统中采用常规柱以保证蛋白质质谱鉴定对样品量的要求,3种常规分离柱分别选用凝胶过滤色谱柱TSK-GEL G3000SW_(XL)(300 mm×7.8 mm,5μm)、强阴离子交换色谱柱Hypersil SAX(100 mm×4.6 mm,10μm)和强阳离子交换色谱柱Hypersil SCX(100 mm×4.6 mm,10μm)。最终以酵母细胞蛋白质提取液为样品,对构建的二维系统加以评价,在总蛋白质浓度13.5 mg/mL、上样体积100μL的条件下,将第一维分离等时间切割17次,并将切割馏分全部导入第二维继续分离,二维系统在148 min内获得的总峰容量达到884。说明所构建的系统可以用于蛋白质的在线全二维分离。  相似文献   

5.
In this study, 1-D and 2-D liquid chromatographic systems, namely, conventional HPLC, UPLC, HPLC x HPLC and HPLC x UPLC systems were developed and evaluated for the separation of phenolic acids in wine and juices. In the LC x LC studies, the first dimension separation was based on RPLC and the second dimension was performed with ion-pair chromatography. Three different columns, namely two short columns packed with either 2.5 or 1.7 microm particles and a monolithic column, were tested for the fast second dimension separation. The best results were obtained when the monolithic column was applied for the second dimension separation. The peak capacities for comprehensive 2-D systems varied from 330 to 616.  相似文献   

6.
Liang J  Yang Z  Cao X  Wu B  Wu S 《Journal of chromatography. A》2011,1218(36):6191-6199
In this work, we have established a new stop-and-go two-dimensional chromatography coupling of counter-current chromatography and liquid chromatography (2D CCC × LC) for the preparative separation of two novel antioxidant flavonoids from the extract of alfalfa (Medicago sativa L.). The CCC column has been used as the first dimension to purify the target flavonoids using a solvent system of isopropanol and 20% sodium chloride aqueous solution (1:1, v/v) with the stop-and-go flow technique, and the LC column packed with macroporous resin has been employed as the second dimension for on-line absorption, desalination and desorption of the targeting effluents purified from the first CCC dimension. As a result, two novel flavonoids, 6,8-dihydroxy-flavone-7-O-β-D-glucuronide (15.3 mg) and 6-methoxy-8-hydroxy-flavone-7-O-β-D-glucuronide (13.7 mg), have been isolated from 126.8 mg of crude sample pre-enriched by macroporous resin column. Their structures have been identified by electrospray ionization mass spectrometry (ESI-MS), electrospray ionization time-of-flight mass spectrometry (ESI-TOF-MS) and one- and two-dimensional nuclear magnetic resonance spectra (1D and 2D NMR). Further antioxidant assays showed that the first component possess a strong antioxidant activity. All the results demonstrated that the stop-and-go 2D CCC × LC method is very efficient for the separation of flavonoids of alfalfa and it can also be applied to isolate other comprehensive multi-component natural products.  相似文献   

7.
Retentivity tuning in comprehensive two dimensional GC separations of aliphatics (linear and cyclic hydrocarbons) and aromatics in gasoline by changing the carrier gas flows in the column series at constant working temperature parameters of both columns is discussed. Comprehensive 2D techniques studied include GC×GC with cryogenic and differential flow modulation and non-modulated transfer (NMT). In all configurations, the first dimension was a non-polar column and the second dimension a polar column. Using three different flows (0.6, 1.0 and 1.4mL/min) of helium carrier gas in cryogenic modulated GC×GC illustrated that, as expected, retention of the solutes on the (1)D and (2)D columns increased but the separation quality was nearly constant. A change of carrier gas pressure (p(m)=175-125kPa) on the (1)D and (2)D columns joint point at constant inlet pressure (p(i)=525kPa) in NMT, induces an increase of the carrier gas flow rate on the (1)D and a decrease on the (2)D column, respectively. The higher retentivity of the (2)D column improved the group type separation of aliphatic/cyclic hydrocarbons and aromatics and a higher distribution of aromatics on the 2D retention plane was noted. Retentivity tuning was also performed in flow modulated GC×GC by operating the (1)D column at 0.8mL/min and the (2)D column at 20 and 26mL/min. The higher retentivity at 20mL/min improved the group type separation of aliphatic/cyclic hydrocarbons and aromatics in the 2D retention plane.  相似文献   

8.
An optimized 2-D liquid chromatography (LC×LC) set-up, based on the different selectivities of a silver ion (Ag) and a non-aqueous reversed phase (NARP), employed in the first (D1) and the second dimension (D2), respectively, in combination with evaporative light-scattering detection (ELSD), has been developed for the analysis of the triacylglycerol (TAG) fraction in a Borago officinalis oil. The 2-D set-up, thanks to the complementary separation selectivity provided by the two columns, allowed to distribute 78 TAGs throughout the 2-D LC retention plane otherwise unachievable by 1-D LC.  相似文献   

9.
A comprehensive two-dimensional liquid chromatography method has been applied for the quantification of polyphenols in red wines and compared to the most commonly employed conventional LC approach. Such methodology comprised the use of a microbore conventional HPLC column packed with totally porous particles in the first dimension and a partially porous column of conventional diameter in the second dimension. Even though a good number of applications in comprehensive LC have been reported, quantification experiments have been rarely described. To this regard, the advantages of comprehensive LC together with the employment of dedicated software capable of detecting and quantifying each peak from the 2D plot, have been taken into account for quantifying the most representative polyphenols in three different commercial Sicilian red wine samples. The optimized method has been validated in terms of linearity, sensitivity, detection and quantification limits. LODs as low as 0.02 ppm were obtained using the one-dimensional HPLC-DAD method, whereas values lower than 0.10 ppm were obtained by comprehensive LC. However, comprehensive LC allowed the quantification of a higher number of compounds with RSD lower than 10% thanks to its improved resolving power. The separation capabilities of comprehensive LC allowed the analysis of complex natural samples without any pre-treatment to effectively reduce the interferences coming from the matrix.  相似文献   

10.
Jia L  Tanaka N  Terabe S 《Electrophoresis》2005,26(18):3468-3478
A two-dimensional (2-D) separation system of coupling chromatography to electrophoresis was developed for profiling Escherichia coli metabolites. Capillary liquid chromatography (LC) with a monolithic silica-octadecyl silica column (500 x 0.2 mm ID) was used as the first dimension, from which the effluent fractions were further analyzed by capillary electrophoresis (CE) acting as the second dimension. Field-enhanced stacking was selectively employed as a concentration strategy to interface the two dimensions, which proved to be beneficial for the detection of metabolites. An artificial sample containing 118 standards, some of which lack chromophores or have weak UV absorbance, was used to optimize the 2-D separation system. Under the optimum conditions, 63 components in the artificial sample having absorbance at 254 nm could be well resolved and detected. The utility of the system was demonstrated by comprehensive analysis of E. coli metabolites. Comparing with the previous 2-D separation system we published in Anal. Chem. 2004, 76, 1419-1428, using a longer monolithic column in the first dimension improved the separation efficiency and offered the possibility of increasing the injection volume without compromising the separation efficiency. In the second dimension, field-enhanced stacking was used to improve the concentration sensitivity of the metabolites, and more metabolites in E. coli cell extract were detected and identified using the developed 2-D separation system. In addition, preliminary investigation for future CE-mass spectrometry coupling was also made in the study by using volatile buffers in the capillary LC and CE techniques.  相似文献   

11.
张兵  郑明辉  刘国瑞  李成  高丽荣 《分析化学》2012,40(8):1213-1218
建立了全二维气相色谱-电子捕获检测器(GC× GC-μECD)检测土壤中毒杀芬同类物的分析方法.以非极性的DB- XLB(20 m×0.25 mm×0.25 μm)为第一色谱柱,中等极性的BPX-50(2 m×0.1 mm×0.1 μm)为第二色谱柱,对土壤中23种高关注毒杀芬同类物进行了分离鉴定,并采用基质曲线外标法进行定量分析.本方法在1~200,μg/L浓度范围内,毒杀芬同类物的线性相关系数(r2)均大于0.99,方法检出限(S/N=3)为0.039~0.482 μg/L,基质加标毒杀芬同类物的回收率为55%~115%,相对标准偏差(RSD)均小于30%(n=5).利用本方法对毒杀芬污染的土壤样品进行了测定,获得了较好的分离效果.  相似文献   

12.
Natural phenolic antioxidants were separated using comprehensive 2D HPLC on a Purospher Star RP-18e column in the first dimension and on two parallel Zirconia Carbon columns working in alternating cycles in the second dimension. The combination of the two columns provides great differences in separation selectivity in each dimension and an almost orthogonal 2D system. Temperature and solvent gradients were compared for the separation of the first-dimension fraction in the stop-flow heart-cutting 2D setup. Temperature gradients provide shorter separation times in comparison with solvent gradients. However, the time required for post-run column equilibration is too long for comprehensive LC × LC. High-temperature isocratic separation was employed in the second dimension of the comprehensive setup, allowing improvement of the fraction transfer frequency between the two dimensions and shorter 2D separation time in comparison to the earlier published method. The approach was applied to the analysis of beer and wine.  相似文献   

13.
In the present work, a comprehensive LC system using a microbore HPLC column in the first dimension and a partially porous column in the second dimension was developed and applied to the separation of polyphenolic components in a red wine sample. The performance of the partially porous short column (3.0 cm) was compared to that of a monolithic column, of comparable dimensions. The results obtained demonstrated the possibility to use partially porous columns to obtain fast analyses, using high flow rates, under repetitive gradient conditions and with very brief reconditioning times. A conventional HPLC system was used since the backpressure generated by the shell-packed column, even at very high flow rates, was well within the operational limits. The use of an increased column temperature (60 degrees C) allowed a further pressure-drop decrease, with no stationary phase degradation, or loss in column performance.  相似文献   

14.
A loading and productivity study was done using three racemates on vancomycin and teicoplanin-bonded chiral stationary phases of different particle formats. Two columns were packed with 2.7 μm superficially porous particles and two columns were packed with identically bonded 5 μm fully porous particles. The last two columns were packed with specially synthesized 4.5 μm vancomycin and teicoplanin superficially porous particles. The loading of different chiral compounds showed that the columns filled with 2.7-μm chiral stationary phases were inappropriate for preparative separations due to their very low permeability which precluded high flow rates. However, columns containing 4.5 μm superficially porous (core-shell) particles were as effective for small-scale preparative chiral separations as columns filled with classical 5 μm fully porous particles. Comparing the 4.5 μm superficially porous particles and 5 μm fully porous particles teicoplanin columns, the observed respective productivities of 270 and 265 mg/g chiral phase/h for 5-methyl-5-phenyl hydantoin enantiomers were obtained. Particular attention was given to the peculiar case of the mianserin enantiomeric separation on vancomycin columns that gave observed productivities of 200 and 205 mg/g chiral phase/h on the 4.5 μm superficially porous particles and 5 μm fully porous particles, respectively.  相似文献   

15.
A novel approach for the selection of the operational parameters (linear velocity, column length) for a comprehensive 2D-LC system is discussed. Starting point for the calculations is a given second dimension ((2)D) separation and a desired peak capacity for the 2D system. Using the theory developed here the optimum settings for the first dimension ((1)D) column can be derived. Theory clearly indicates that the choice of the (1)D conditions is basically limited to just one set of column lengths and linear velocities. The new method is tested on a comprehensive two-dimensional liquid chromatography system which uses size-exclusion chromatography (SEC) followed by reversed phase liquid chromatography (RPLC). A novel LC/LC interface, using a six-port valve rather than storage loops, joins the two chromatographic dimensions. From a theoretical comparison of continuous low flow and stop-flow operation the latter method was found to be an attractive mode of interfacing. The common idea that stop-flow operation results in additional band broadening is shown to be incorrect. The new interface design operated in the stop-flow mode permits the use of conventional analytical diameter HPLC columns, 7.8mm for SEC and 4.6mm for RPLC. The reversed phase chromatography utilizes a monolithic C-18 modified silica column, which produces fast and efficient analyses. As test samples complex mixtures of peptides were analyzed.  相似文献   

16.
Li X  Carr PW 《Journal of chromatography. A》2011,1218(16):2214-2221
Comprehensive two-dimensional liquid chromatography (LC×LC) has received a great deal of attention during the past few years because of its extraordinary resolving power. The biggest advantage of this technique is that very high peak capacities can be generated in a relatively short time. Numerous approaches to maximize the peak capacity in LC×LC have been employed. In this work we investigate the impact of the first dimension mobile phase on selectivity. LC×LC has several potential advantages over one-dimensional LC (1DLC) in that unconventional solvents, at least in reversed-phase LC, can be used. For example, solvents which strongly adsorb in the UV in the first dimension are not problematic in LC×LC. This so because the UV detector is placed after the second dimensional column, as pulses of the first dimension eluent arrive at the second dimensional column, they elute well before the solutes of interest and therefore do not interfere at all with detection of solute peaks. So far, the most widely used solvents in reversed-phase 1DLC are methanol and acetonitrile. However, the "UV advantage" of 2DLC allows us to employ UV active solvents, such as acetone. We compare their differential selectivities to that of acetonitrile for the separation of 23 indole acetic acids of interest in plant biology. We also apply them to the separation of a maize seed extract, a very complex sample. In both sample sets, mobile phase composition can be an important parameter to increase the orthogonality of the two dimensions and thus, to increase the effective peak capacity of LC×LC.  相似文献   

17.
徐磊  夏宁 《分析测试学报》2011,30(5):558-561
建立了一种在线固相萃取/高效液相色谱测定水样中4种痕量邻苯二甲酸酯(邻苯二甲酸甲酯、邻苯二甲酸乙酯、邻苯二甲酸丁酯和邻苯二甲酸(2-乙基)己酯)的新方法.样品由外加泵注入一根固相萃取小柱上进行富集,再将富集柱切换至高效液相色谱系统中,将富集在固相萃取小柱的邻苯二甲酸酯洗脱至分析柱进行分析.在线固相萃取柱为IonPac(...  相似文献   

18.
Hu L  Li X  Feng S  Kong L  Su X  Chen X  Qin F  Ye M  Zou H 《Journal of separation science》2006,29(6):881-888
A mode of comprehensive 2-D LC was developed by coupling a silica-bonded HSA column to a silica monolithic ODS column. This system combined the affinity property of the HSA column and the high-speed separation ability of the monolithic ODS column. The affinity chromatography with HSA-immobilized stationary phase was applied to study the interaction of multiple components in traditional Chinese medicines (TCMs) with HSA according to their affinity to protein in the first dimension. Then the unresolved components retained on the HSA column were further separated on the silica monolithic ODS column in the second dimension. By hyphenating the 2-D separation system to diode array detector and MS detectors, the UV and molecular weight information of the separated compounds can also be obtained. The developed separation system was applied to analysis of the extract of Rheum palmatum L., a number of low-abundant components can be separated on a single peak from the HSA column after normalization of peak heights. Six compounds were preliminarily identified according to their UV and MS spectra. It showed that this system was very useful for biological fingerprinting analysis of the components in TCMs and natural products.  相似文献   

19.
Yang X  Zhang X  Li A  Zhu S  Huang Y 《Electrophoresis》2003,24(9):1451-1457
A novel comprehensive two-dimensional (2-D) separation system coupling capillary high-performance liquid chromatography (cHPLC) with microchip electrophoresis (chip CE) is demonstrated. Reversed-phase cHPLC was used as the first dimension, and chip CE acted as the second dimension to perform fast sample transfers and separations. A valve-free gating interface was devised simply by inserting the outlet-end of LC column into the cross-channel on a specially designed chip. A home-made confocal laser-induced fluorescence detector was used to perform on-chip high-sensitive detection. The cHPLC effluents were continuously delivered to the chip and pinched injections of the effluents every 20 seconds were employed for chip CE separation. Gradient elution of cHPLC was carried out to obtain the high-efficiency separation. Free-zone electrophoresis was performed with triethylamine buffer to achieve high-speed separation and prevent sample adsorption. Such a simple-made comprehensive system was proved to be effective. The relative standard deviations for migration time and peak height of rhodamine B in 150 sample transfers were 3.2% and 9.8%, respectively. Peptides of the fluorescein isothiocyanate (FITC)-labeled tryptic digests of bovine serum albumin were fairly resolved and detected with this comprehensive 2-D system.  相似文献   

20.
The experimental effects of sampling time on the resolving power of on-line LC×LC were investigated. The first dimension gradient time ((1)t(g)) and sampling time (t(s)) were systematically varied ((1)t(g)=5, 12, 24 and 49 min; t(s)=6, 12, 21 and 40s). The resolving power of on-line LC×LC was evaluated in terms of two metrics namely the numbers of observed peaks and the effective 2D peak capacities obtained in separations of extracts of maize seeds. The maximum effective peak capacity and number of observed peaks of LC×LC were achieved at sampling times between 12 and 21s, at all first dimension gradient times. In addition, both metrics showed that the "crossover" time at which fully optimized 1DLC and LC×LC have equal resolving power varied somewhat with sampling time but is only about 5 min for sampling times of 12 and 21s. The longest crossover time was obtained when the sampling time was 6s. Furthermore, increasing the first dimension gradient time gave large improvements in the resolving power of LC×LC relative to 1DLC. Finally, comparisons of the corrected and effective 2D peak capacities as well as the number of peaks observed showed that the impact of the coverage factor is quite significant.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号