首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 562 毫秒
1.
The efficiencies of conventional extraction techniques and analytical methods (HPLC–DAD and ELISA) were investigated for analyses of microcystins (MCs) in sediments. Our results showed several limitations. First, the extraction efficiency strongly depends on the extraction solvent, and extraction with 5% acetic acid in 0.2% trifluoroacetic acid (TFA)–methanol was confirmed as being the most appropriate for three different sediments (recovery: 33.1–44.9% of total MCs according to HPLC analyses). Second, the recovery of MCs was affected by the type of sediment but did not clearly correlate with the content of organic carbon. These results suggest that the sorption of MCs onto inorganic materials such as clay minerals is probably a more important process than interactions of the MCs with organic sediment matter. Third, the structure of the MCs is another crucial factor that affects the sorption of MCs and their recovery from sediments. Hydrophilic MC-RR gave much lower recoveries (20.0–38.8%) than MC-YR (44.1–59.5%) or MC-LR (55.3–77.8%) from three different types of spiked sediments. Recovery results analysed with HPLC–DAD correlated well with ELISA analyses. Further, extraction with 5% acetic acid in 0.2% TFA–methanol was used for analyses of MCs in 34 natural sediment samples collected from Brno reservoir (Czech Republic) from April to October 2005. Concentrations of MCs in sediments ranged from 0.003 to 0.380 μg/g sediment d.m. (ELISA results) or 0.016–0.474 μg/g d.m. (HPLC results). These values are equivalent to 0.63–96.47 μg/L of sediment (ELISA) or 4.67–108.68 μg/L (HPLC), respectively. Concentrations of sediment MCs showed both temporal and spatial variability, with the highest MC contents observed in the spring (April and May) and the lowest concentrations in July and August. Our results demonstrate the suitability of the methods described here for studying the occurrence, fate and ecological role of MCs in the aquatic environment.   相似文献   

2.
Microwave-assisted leaching of organotin compounds from sediment samples followed by the simultaneous extraction-derivatization of the extracted species was revisited with the goal to compare the existing procedures, improve their recoveries and extend them to phenyltin compounds. The stability of butyl- and phenyltin compounds under microwave field, real recoveries of the whole analytical procedure, effect of the extraction solvent, and the necessity for an internal standard were evaluated using two candidate reference sediments. The combination of the optimized sample preparation procedure with multicapillary chromatography resulted in a rapid (2 min leaching + 5 min extraction-derivatization + 3 min chromatographic separation) and efficient analytical procedure for speciation analysis of organotin compounds in sediment samples. The detection limit achieved with a microwave-induced plasma atomic emission detector was 2 ng g–1. Received: 27 July 1998 / Revised: 31 August 1998 / Accepted: 4 September 1998  相似文献   

3.
Abstract

This study aims to evaluate different procedures for the extraction of organochlorine pesticides (OCP's) from natural waters and sediments. In the case of extraction from water, a C18 disk solid-phase extraction method was employed. Recovery experiments in the range of 40 to 200 ng/l with selected organochlorine compounds resulted in average recoveries between 80 and 100%. Four different solvents, hexane, ethyl acetate, acetonitrile and methanol, were tested as eluting agents. Best recoveries were obtained with ethyl acetate and hexane. A comparative study of OCP sediment extraction procedures was performed employing sonication, Soxhlet extraction and shake-flask methods. The capacity of these methods to recover OCP's from a sediment sample fortified at 50 ng/g was evaluated using hexane : acetone (1:1 v/v), hexane: acetone (8:2 v/v), acetonitrile and dichlorometane. The three extraction techniques gave similar results and dichloromethane was the most effective solvent. The optimised methods were applied in the analysis of waters and sediments from the “Aiguamolls de l'Empordà” Nature Park, Girona (Spain).  相似文献   

4.
A new approach for the analysis of the cyanobacterial microcystins (MCs) in environmental water matrices has been developed. It offers a cost efficient alternative method for the fast quantification of total MCs using mass spectrometry. This approach permits the quantification of total MCs concentrations without requiring any derivatization or the use of a suite of MCs standards. The oxidation product 2-methyl-3-methoxy-4-phenylbutyric acid (MMPB) was formed through a Lemieux oxidation and represented the total concentration of free and bound MCs in water samples. MMPB was analyzed using laser diode thermal desorption-atmospheric pressure chemical ionization coupled to tandem mass spectrometry (LDTD-APCI-MS/MS). LDTD is a robust and reliable sample introduction method with ultra-fast analysis time (<15 s sample−1). Several oxidation and LDTD parameters were optimized to improve recoveries and signal intensity. MCs oxidation recovery yield was 103%, showing a complete reaction. Internal calibration with standard addition was achieved with the use of 4-phenylbutyric acid (4-PB) as internal standard and showed good linearity (R2 > 0.999). Limits of detection and quantification were 0.2 and 0.9 μg L−1, respectively. These values are comparable with the WHO (World Health Organization) guideline of 1 μg L−1 for total microcystin-LR congener in drinking water. Accuracy and interday/intraday variation coefficients were below 15%. Matrix effect was determined with a recovery of 91%, showing no significant signal suppression. This work demonstrates the use of the LDTD-APCI-MS/MS interface for the screening, detection and quantification of total MCs in complex environmental matrices.  相似文献   

5.
An analytical procedure using accelerated solvent extraction and gas chromatography with an electron capture detector has been optimized to simultaneously determine the residue of two insecticides (diazinon and EPN) and one fungicide (isoprothiolane) in polished rice and was confirmed by GC-mass spectrometry. Several parameters, including temperature, pressure, solvent ratio, cell size and cell cycle, were thoroughly investigated to find the optimal extraction conditions. The average recoveries of the three pesticides were between 82.7 and 126.4% at spiking levels of 0.1 and 0.5 ppm. The relative standard deviations were less than 7% for all of the recovery tests. The optimum accelerated solvent extraction operating conditions were 100 degrees C, 1500 atm, acetone-n-hexane (20:80 v/v) as the extraction solvent, two cycles, and a cell size of 33 ml. The total extraction time was approximately 20 min. The optimized procedure has also been applied to the determination of diazinon, isoprothiolane and EPN in real rice samples. In conclusion, accelerated solvent extraction was used for the first time for the analysis of diazinon, isoprothiolane and EPN in polished rice and offers the possibility of a fast and simple process for obtaining a quantitative extraction of the studied pesticides.  相似文献   

6.
Summary An analytical procedure for the individual determination of ortho and non-ortho PCB congeners in sediments, using high performance liquid chromatography (HPLC) preseparation and gas chromatography/ECD detection, is described. Gas chromatography/FTIR spectrometry (GC/FTIR) and gas chromatography/mass spectrometry (GC/MS) were employed for individual congener identification and determination. Sample extraction, clean-up of extract and selective elution procedures were optimized by using reference certified marine sediment samples. Recovery and precision were typically 83% and 16% respectively at 2 ng/g of total PCB content. The proposed procedure, tested by analyzing real sediment samples, showed a reproducibility better than 20% at 13 ng/g PCB level.  相似文献   

7.
Microcystins (MCs) comprise a family of more than 80 related cyclic hepatotoxic heptapeptides. Oxidation of MCs causes cleavage of the chemically unique C20 β-amino acid (2S, 3S, 8S, 9S)-3-amino-9-methoxy-2,6,8-trimethyl-10-phenyldeca-4,6-dienoic acid (Adda) amino to form 2-methyl-3-methoxy-4-phenylbutanoic acid (MMPB), which has been exploited to enable analysis of the entire family. In the present study, the reaction conditions (e.g. concentration of the reactants, temperature and pH) used in the production of MMPB by oxidation of cyanobacterial samples with permanganate-periodate were optimized through a series of well-controlled batch experiments. The oxidation product (MMPB) was then directly analyzed by high-performance liquid chromatography with diode array detection. The results of this study provided insight into the influence of reaction conditions on the yield of MMPB. Specifically, the optimal conditions, including a high dose of permanganate (≥50 mM) in saturated periodate solution at ambient temperature under alkaline conditions (pH ∼9) over 1-4 h were proposed, as indicated by a MMPB yield of greater than 85%. The technique developed here was applied to determine the total concentration of MCs in cyanobacterial bloom samples, and indicated that the MMPB technique was a highly sensitive and accurate method of quantifying total MCs. Additionally, these results will aid in development of a highly effective analytical method for detection of MMPB as an oxidation product for evaluation of total MCs in a wide range of environmental sample matrices, including natural waters, soils (sediments) and animal tissues.  相似文献   

8.
This study proposes a microwave-assisted method for the simultaneous extraction of highly prescribed antidepressants (citalopram, venlafaxine, fluoxetine, sertraline and amitriptyline) and caffeine from sediments and sewage sludge for subsequent HPLC-PDA analysis. Because the sludge and sediment matrices have high contents of organic material, they strongly interact with the analytes and hinder extraction. Thus, a carefully optimised analytical methodology is required for quantitative extraction. A simplex-centroid design was applied to optimise the solvent composition, and a three-factor central composite rotational design was used to optimise the extraction protocol with regards to pH, amount of solvent and processing time. Samples (in triplicates) were fortified with a standard mixed solution of all the analytes and extracted according to the experimental design in each study. The extraction steps included: 30 s vortexing, 20 s microwave heating at 10 W, cooling to room temperature (25°C) in an ultrasonic bath for 60 s, 2 min centrifugation at 2000 rpm, and filtration. Analysis of variance and lack-of-fit tests were used to assess the significance of data fitting at 95% confidence. The desirability function was the optimisation tool used to obtain the ideal extraction conditions. As a result, a binary mixture of methanol and acetonitrile in 45:55 and 53:47 (v/v) ratios was indicated as the optimum solvent composition for the simultaneous extraction of all the target drugs from the sludge and sediment, respectively. The optimised extraction conditions were: 3 extraction cycles with 4 mL of solvent at pH 3 for sewage sludge extraction and 4 extraction cycles with 3 mL of solvent at pH 11 for sediment extraction. Further, low recoveries were obtained for extractions from sediment as compared to sludge indicating strong interaction of antidepressants and caffeine with the acidic organic components of sediments. It was found that the optimisation of pH of the extraction phase was crucial for the efficient extraction of the analytes from these environmental matrices.  相似文献   

9.
A dispersive liquid–liquid microextraction procedure based on solidification of floating organic droplet has been investigated for the determination of fungicides (cyprodinil, difenoconazole, myclobutanil, and spiroxamine) in sediments by HPLC with diode array detection. In the overall extraction process, the extraction solvents can be separated easily from the sample solution, and the experiment time was shortened. Moreover, several parameters such as the type and volume of the extraction solvent and dispersive solvent, centrifugal speed, extraction time, and salt effect that affect the extraction efficiencies of the target fungicides were studied and optimized. Under the optimized conditions, the LOD for the target analytes were in the range of 0.1–0.5 μg/g. Satisfactory recoveries of the target analytes in the sediment samples were 81.00–99.00%, with RSDs (n = 5) that ranged from 1.8 to 6.5%. Finally, the simple, sensitive, and environmentally friendly method was successfully applied to determine the target fungicides in actual sediment samples.  相似文献   

10.
Nitro-polycyclic aromatic hydrocarbons have been detected in various environmental media. However, determination in sediment matrix is challenging due to the lack of a suitable method. In this study, a reliable method for determining 15 nitro-polycyclic aromatic hydrocarbons in sediments was developed based on accelerated solvent extraction and solid-phase microextraction coupled with gas chromatography–tandem mass spectrometry. The accelerated solvent extraction and solid-phase microextraction are sample pre-treatment techniques that have advantages, such as rapid operation and minimal sample volume. Initially, the solid-phase microextraction was optimized using five commercial fibers and from that 65 μm polydimethylsiloxane/divinylbenzene fiber was selected as the best fiber. Further, the accelerated solvent extraction conditions were optimized by Taguchi experimental design, such as extraction temperature (120℃), extraction solvent (dichloromethane), number of cycles (two), static extraction period (4 min), and rinse volume (90%). The method parameters, such as limits of quantitation, and intraday and interday accuracy and precision, were in the range of 0.067–1.57 ng/g, 75.2–115.2%, 69.9–115.4%, and 1.0–16.5%, respectively. Upon meeting all the quality criteria, the method was applied successfully to analyze real sediment samples. Therefore, our study creates a new prospect for the future application of direct immersion solid-phase microextraction in sediment analysis.  相似文献   

11.
An analytical procedure based on extraction by accelerated solvent extraction (ASE) followed by gas chromatography–mass spectrometry (GC/MS) analysis has been developed for the determination of particulate polycyclic aromatic hydrocarbons (PAHs) from large-volume water samples (20 L). The effect of temperature and number of cycles on the efficiency of ASE was investigated: the best results were obtained by using a temperature of 100°C and one static cycle. A mixture of hexane/acetone 1:1 (v/v) was used as extraction solvent. Mean total method recovery under optimized conditions was 85%. The developed methodology was applied to the analysis of suspended particulate matter from Lake Maggiore waters (north of Italy). Mean PAH concentrations in suspended particulate matter from Lake Maggiore ranged from 0.2 ng L−1 for anthracene to 18.7 ng L−1 for naphthalene.  相似文献   

12.
Di‐(2‐ethylhexyl)phthalate (DEHP) was determined in environmental samples such as water and soil. DEHP was extracted from water samples using SPE, whereas for soils pressurized liquid extraction was applied as extraction method, using hexane/acetone (1:1, v/v) as extractant solvent. The use of HPLC coupled to MS provides the basis of the selective determination of DEHP in the analyzed samples. The extraction procedures were validated and good results were found. Recoveries were ranged from 86.0 to 99.8% with RSD lower than 18% and LODs were 0.02 mg/kg and 0.03 μg/L for soils and water, respectively. Finally, the optimized methods were applied to the analysis of real samples and DEHP was not found above the LOQ (0.05 mg/kg) in soil samples whereas it was detected in water samples at concentrations ranging between 0.19 to 0.88 μg/L.  相似文献   

13.
A liquid chromatographic method with inductively coupled plasma mass spectrometry is proposed for the speciation of butyl- (monobutyltin, dibutyltin, tributyltin) and phenyl- (monophenyltin, diphenyltin, triphenyltin) tin compounds in sediments. After evaluation of different additives in the mobile phase, the use of 0.075% (w/v) of tropolone and 0.1% (v/v) of triethylamine in a mobile phase of methanol-acetic acid-water (72.5:6:21.5) allowed the best chromatographic separation of the six compounds. Pressurized liquid extraction (PLE) with a methanolic mixture of 0.5 M acetic acid and 0.2% (w/v) of tropolone was suitable for the quantitative extraction of butyl- and phenyltin compounds with recovery values ranging from 72 to 102%. This analytical approach was compared to conventional solvent extraction methods making use of acids and/or organic solvent of medium polarity. The main advantages of PLE over conventional solvent extraction are: (i) the possibility to extract quantitatively DPhT and MPhT from sediments, which could not be done by a solvent extraction approach; (ii) to preserve the structural integrity of the organotin compounds; (iii) to reduce the extraction time from several hours in case of solvent extraction techniques to just 30 min. For spiked sediments, limits of detection ranged from 0.7 to 2 ng/g of tin according to the compound. The relative standard deviations were found to be between 8 and 15%. The developed analytical procedure was validated using a reference material and was applied to various environmental samples.  相似文献   

14.
The aim of this work was to optimize an ultrasonic extraction procedure for the determination of polycyclic aromatic hydrocarbons (PAHs) in sediments and to compare it with the reflux procedure using methanolic potassium hydroxide. Sample extracts were purified with a miniaturized silica gel chromatographic column and analyzed by gas chromatography-mass spectrometry (GC-MS). Ultrasonication using n-hexane-acetone (1:1, v/v) solvent mixture on dried homogenized marine sediment gave better precision (smaller relative standard deviation (RSD) values) and comparable quantities of individual PAH's compared to the reflux procedure. Ultrasonication with the n-hexane-acetone (1:1, v/v) mixture, utilizing four 15 min extraction cycles, was found to be sufficient for extracting PAHs from wet sediments. The optimized ultrasonic extraction procedure extracted aliphatic and aromatic hydrocarbons from the National Institute of Standards and Technology SRM 1941a with recoveries greater than 90%. The major advantages of ultrasonication compared to the reflux method are the lower extraction times, simplicity of the apparatus and extraction procedure. The optimized ultrasonication procedure has been used in our laboratory to extract hydrocarbons from naturally wet sediments from rivers, and coastal and marine areas.  相似文献   

15.
A new methodology based on pressurized liquid extraction (PLE) followed by LC-MS is presented for the simultaneous and unequivocal determination of alkylphenol ethoxylates (APEOs) and their degradation products, alkylphenols (APs) and alkylphenoxy carboxylates (APECs), in sediment samples. The protocol, applicable to a full range of APEO oligomers and degradation products, permits the sensitive and selective determination of APEOs (nEO = 1-15), APECs (nEO = 0-1) and APs at low ppb levels (LODs = 1-5 microg/kg) in sediment samples. Optimization of the operational parameters of PLE clearly demonstrates that significant thermal losses of APs occur during extraction at elevated temperatures. The loss of octylphenol (OP) at 100 degrees C was 61.2% and of nonylphenol (NP) 40.0%, whereas other compounds were completely recovered. Thus, to avoid losses due to the volatility of alkylphenols, a low extraction temperature should be applied. The conditions that gave the best results for all target compounds were as follows: extraction solvent mixture, methanol-acetone (1:1, v/v); temperature, 50 degrees C; pressure, 1500 p.s.i.; two static cycles. Using PLE and a subsequent clean-up with solid-phase extraction (SPE), the simultaneous extraction of APEOs, APs and APECs from sediment samples was achieved yielding recoveries >70% and producing low MS background noise. The developed methodology was applied on a routine basis to the analysis of alkylphenolic compounds in sediment samples. APEOs and their persistent degradation products were detected in significant concentrations in sediments from Portuguese rivers, especially at sites situated in the proximity of industrial plants (mainly the textile industry). The total concentration of alkylphenolic compounds (APEOs+APs+APECs) ranged from 155 to 2400 microg/kg. Of all the alkylphenolic compounds, NP comprised 40 to 50% with concentrations up to 1172 microg/kg.  相似文献   

16.
A rapid and automated method for the determination of monomethylmercury (MMHg) in environmental samples was developed using headspace gas chromatography with atomic fluorescence detection in combination with aqueous phase ethylation. Sample preparation steps were optimized for sediments, biological samples, and water samples using certified reference materials and real samples with a broad range of MMHg concentrations. Different extraction procedures were compared for both sediments and biological samples. The methods were applied in the intercomparison exercises for the certification of MMHg in sediments (IAEA 405) and in Oyster tissue (BCR 710) and the results were accepted for certification. The detection limits for MMHg are 0.002 ng Hg/g for sediments and biological samples and 0.01 ng Hg/L for water samples. The method was tested for methylation artifacts; no artifact was observed in the sediment samples and CRMs tested.  相似文献   

17.
沉积物是多环芳烃(polycyclic aromatic hydrocarbons,PAHs)在环境中迁移归趋的一个重要的汇[1]。沉积物中多环芳烃的提取方法主要有索氏提取、超声波提取、微波萃取、加速溶剂提取及超临界流体萃取等。其中加速溶剂提取(accelerated solvent extraction,ASE)由于提取速度快,溶  相似文献   

18.
The aim of this study was to develop an analytical method to determine the organochlorine concentrations in sediments. Combination of Microwave assisted Solvent Extraction (MASE) and capillary gas chromatography with specific detection (electron capture detector) was a viable approach for the determination of pesticides in solid matrixes. In this study, MASE development was focused on the selection of a suitable extraction solvent for all the target analytes. MASE procedure was validated by comparison with conventional methods such as Soxhlet and sonication extraction. The proposed method was then applied to determine the organochlorine insecticides concentrations in samples from Authie Bay (France). Environmental water samples were analysed and five target analytes were detected in concentrations from 0.03 to 0.56 ng/g of dry sediment. These investigations showed the accumulation and the persistency of these products in sediments in spite of the fact they were banned a few decades ago.  相似文献   

19.
The 3 steps sequential extraction procedure proposed by the Standards Measurements and Testing program (SM&T--formerly BCR) of the European Union has been applied for the speciation of metals in sediments. Results obtained by the application of the BCR standardized procedure were compared to those of two four step sequential extraction procedures, which are different from the BCR procedure only for the introduction of an additional step with NaOCl, as 2nd and 3rd step respectively. Five different metals have been taken into consideration: Cd, Cu, Ni, Pb and Zn. The analytical performances of the laboratory have been evaluated using three certified reference materials: the BCR 601 lake sediment for the BCR sequential extraction procedure, PACS-1 and MESS-1 for total metal concentration. Results showed that the efficiency of NaOCl treatment is higher or at least equal to that of H2O2 treatment and that its selectivity is quite satisfying. Moreover the NaOCl treatment doesn't significantly influence the extraction of the easily reducible fraction.  相似文献   

20.
New ternary deep eutectic solvents were prepared and applied as efficient green dispersing solvents in miniaturized matrix solid-phase dispersion to extract chlorophenols from river sediments for the first time. High-performance liquid chromatography coupled with a photodiode array detector was used to analyze the target analytes. The significant factors affecting the extraction were optimized as follows: dispersant (100 mg), sample (100 mg), ternary eutectic solvents (150 μl), grinding for 1 min, 450 μl of acetonitrile as the elution solvent, and vortex mixing for 20 s. Under the optimal conditions, the method exhibited excellent linearity (correlation coefficient > 0.9980), low limits of detection between 1.039–2.478 μg/g, and extraction recoveries between 93.9% and 99.2%. Furthermore, the method demonstrated excellent precision in the intra- and inter-day analysis with a relative standard deviation below 6%. When compared to conventional extraction techniques, the miniaturized matrix solid-phase dispersion considerably reduced samples and solvent usag, offering important environmental benefits. The green profile of the method was assessed using the complementary green analytical procedure index tool confirming its eco-friendship. The technique was finally employed to evaluate sediment samples from three distinct locations along the Zuibaiji River, indicating its applicability for monitoring environmental samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号