1.
A gas chromatography–mass spectrometric method was developed in this study in order to determine fluoride in plasma and urine after derivatization with 2-(bromomethyl)naphthalene. 2-Fluoronaphthalene was chosen as the internal standard. The derivatization of fluoride was performed in the biological sample and the best reaction conditions (10.0 mg mL−1 of 2-(bromomethyl)naphthalene, 1.0 mg mL−1 of 15-crown-5-ether as a phase transfer catalyst, pH of 7.0, reaction temperature of 70 °C, and heating time of 70 min) were established. The organic derivative was extracted with dichloromethane and then measured by a gas chromatography–mass spectrometry. Under the established condition, the detection limits were 11 μg L−1 and 7 μg L−1 by using 0.2 mL of plasma or urine, respectively. The accuracy was in a range of 100.8–107.6%, and the precision of the assay was less than 4.3% in plasma or urine. Fluoride was detected in a concentration range of 0.12–0.53 mg L−1 in six urine samples after intake of natural mineral water containing 0.7 mg L−1 of fluoride.  相似文献   

2.
Matrix-assisted refolding is an excellent technique for performing refolding of recombinant proteins at high concentration because aggregation during refolding is partially suppressed. The autoprotease Npro and its engineered mutant EDDIE can be efficiently refolded on cation-exchangers. In the current work, denatured fusion proteins were loaded at different column saturations (5 and 50 mg mL−1 gel), and refolding and self-cleavage were initiated during elution. The contact time of the protein with the matrix significantly influenced the refolding rate and yield. On POROS 50 HS, the refolding rate was comparable to a batch refolding process, but yield was substantially higher; at a protein concentration of 1.55 mg mL−1, an almost complete conversion was observed. With Capto S, the rate of self-cleavage increased by a factor of 20 while yield was slightly reduced. Processing the autoprotease fusion protein on Capto S at a high protein loading of 50 mg mL−1 gel and short contact time (0.5 h) yielded the highest productivity.  相似文献   

3.
An imidazole derivative, 2-(2′-pyridyl)imidazole (PIMH), was developed as a colorimetric probe for the qualitative analysis of Fe2+ in aqueous solution. PIMH was then used to post-functionalize poly(vinylbenzyl chloride) (PVBC) nanofibers after electrospinning so as to afford a solid state colorimetric probe. Upon treatment with Fe2+ the probe displayed a distinctive color change both in liquid and solid platforms. The linear dynamic range for the colorimetric determination of Fe2+ was 0.0988–3.5 μg mL−1. The ligand showed a high chromogenic selectivity for Fe2+ over other cations with a detection limit of 0.102 μg mL−1 in solution (lower than the WHO drinking water guideline limit of 2 mg L−1), and 2 μg mL−1 in the solid state. The concentration of Fe2+ in a certified reference material (Iron, Ferrous, 1072) was found to be 2.39 ± 0.01 mg L−1, which was comparable with the certified value of 2.44 ± 0.12 mg L−1. Application of the probe to real samples spiked with Fe2+ achieved recoveries of over 97% confirming accuracy of the method and its potential for on-site monitoring.  相似文献   

4.
A simple, rapid and sensitive high-performance liquid chromatography method was developed for the analysis of the sesquiterpene lactone 15-deoxygoyazensolide (LAC15-D) in rat plasma samples. The chromatographic separation was achieved on a LiChrospher® RP18 column using methanol:water (50:50, v/v) containing 0.6% acetic acid as mobile phase, at a flow rate of 0.7 mL min−1. UV detection was carried out at 270 nm. Phenytoin was used as internal standard. Prior to the analysis, the rat plasma samples were submitted to liquid-liquid extraction with dichloromethane. The mean absolute recoveries were 73% with R.S.D. values lower than 3.5. The method was linear over the 6.0-2000 ng mL−1 concentration range and the quantification limit was 6.0 ng mL−1. Within-day and between-day assay precision and accuracy were studied at three concentration levels (15, 300 and 480 ng mL−1) and were lower than 15%. The validated method was used to measure the plasmatic concentration of LAC15-D in rats that received a single intraperitoneal dose of 30 mg kg−1.  相似文献   

5.
In this paper, the conversion of azoxystrobin in a strongly fluorescent degradation product by UV irradiation with quantitative purposes and its fluorimetric determination are reported for the first time. A multicommuted flow injection-solid phase spectroscopy (FI-SPS) system combined with photochemically-induced fluorescence (PIF) is developed for the determination of azoxystrobin in grapes, must and wine. Grape samples were homogenized and extracted with methanol and further cleaned-up by solid-phase extraction on C18 silica gel. Wine samples were solid-phase extracted on C18 sorbent using dichloromethane as eluent. Recoveries of azoxystrobin from spiked grapes (0.5-2.0 mg Kg−1), must (0.5-2.0 μg mL−1) and wine (0.5-2.0 μg mL−1) were 84.0-87.6%, 95.5-105.9% and 88.5-111.2%, respectively. The quantification limit for grapes was 0.021 mg Kg−1, being within European Union regulations, and 18 μg L−1 and 8 μg L−1 for must and wine, respectively.  相似文献   

6.
A sensitive and selective column adsorption method is proposed for the preconcentration and determination of atrazine and simazine. Atrazine and simazine were preconcentrated on heat-treated diatomaceous earth as an adsorbent and then determined by high-performance liquid chromatography (HPLC). Several parameters on the recoveries of the analytes were investigated. The experimental results showed that it was possible to obtain quantitative analysis when the solution pH was 2 using 100 mL of validation solution containing 1.5 μg of triazines and 5 mL of ethanol as an eluent. Recoveries of atrazine and simazine were 95.7 ± 4.2% and 75.0 ± 1.9% with a relative standard deviation for seven determinations of 4.7% and 2.7% under optimum conditions. The maximum preconcentration factor was 100 for triazines when 500 mL of sample solution volume was used. The linear ranges of calibration curves for atrazine and simazine were 1-150 ng mL−1 and 1-300 ng mL−1, respectively, with correlation coefficients of 0.999 and the detection limits (3Signal-to-Noise) were 0.24 ng mL−1 and 0.21 ng mL−1 for atrazine and simazine. The capacity of the adsorbent was also examined and found to be 0.8 mg g−1 and 1.3 mg g−1 for atrazine and simazine, respectively. The proposed method was successfully applied to the determination of triazines in river water and tap water samples with high precision and accuracy.  相似文献   

7.
The routine method of paper chromatography includes five steps: spotting, separating, drying, spraying/immersing and color development. In this paper, a pre-staining paper chromatography which only consisted of spotting, separating and color development was developed for quantitative analysis of γ-aminobutyric acid. Compared to the routine paper chromatography, the improved method is clean, rapid, inexpensive and reproducible. The effects of ninhydrin concentration, color temperature, color time and Cu2+ concentration on the color yield in the ninhydrin reaction were optimized. And then the pre-staining paper chromatography coupled with vis spectrophotometry was applied to γ-aminobutyric acid quantification. The results indicated that the limit of detection was 0.05 mg mL−1 and the linear range was from 0.5 to 20.0 mg mL−1. Furthermore, an excellent correlation coefficient was observed with an R2 = 0.998. The method is accurate (RSD < 2.64%), and has good recoveries (102.7–103.9%). The validation of the modified technique was verified by a HPLC method.  相似文献   

8.
Development of a chemiluminescent immunosensor for chloramphenicol   总被引:3,自引:0,他引:3  
A direct competitive chemiluminescent immunosensor system that exploits the competition between chloramphenicol (CAP) as an analyte and CAP-horseradish peroxidase conjugate as a tracer for binding to an anti-CAP antibody on a solid support was devised by installing a flow-through cell which was connected to an injector and a peristaltic pump inside a dark box, followed by positioning a photomultiplier tube as light detector in front of it. The anti-CAP antibody was immobilized onto positively charged Biodyne B membrane pieces by a dipping procedure. The operating conditions for the immunosensor were selected with respect to substrate composition (0.25, 13.3 and 0.66 mM for luminol, H2O2 and p-iodophenol, respectively), injection volume of the substrate solution (200 μL) and the concentrations of antibody for immobilization (0.10 mg mL−1) and tracer (0.030 mg mL−1). At these conditions, sensor response according to analyte concentration was well fitted to a linear equation when plotted in semi-logarithmic scale, with the limit of detection for CAP of 10−8 M. By using the immunosensor, CAP measurement in the model samples prepared from five food materials was conducted.  相似文献   

9.
Tubino M  de Souza RL 《Talanta》2006,68(3):776-780
A quantitative analytical method for the determination of diclofenac in pharmaceutical preparations by diffuse reflectance in the visible region of the spectrum is presented. The color reaction is done directly in the measuring cell immediately after mixing, using small volumes of the analyte solution, of the reagent and of the buffer solutions. All reflectance measurements were carried out in a home made reflectometer equipped with a red LED as light source and a LDR as detector. The calibration curves were constructed from 1.0 to 18 mg mL−1 (about 3.0 × 10−3 to 5.5 × 10−2 mol L−1) of sodium diclofenac or of potassium diclofenac in the analytical solution, with typical correlation coefficients equal to 0.999. The detection limit was estimated to be about 0.7 mg mL−1 (2 × 10−3 mol L−1). The method was applied to determine diclofenac in solid and liquid pharmaceutical preparations. The R.S.D. varied from 2% to 4% depending of the sample. The results were compared with those obtained with the HPLC procedure recommended by the United States Pharmacopoeia using the statistical Student's t-test procedure.  相似文献   

10.
Zhuo SJ  Zheng H  Chen JL  Li DH  Wu YQ  Zhu CQ 《Talanta》2004,64(2):528-533
A new method was developed for determination of micro amounts of nucleic acids based on near-infrared (near-IR) fluorescence recovery, employing a two-reagent system which is composed of an anionic tetracarboxy aluminum phthalocyanine (AlC4Pc) and a cationic tetra-N-hexadecylpyridiniumyl porphyrin (TC16PyP). The fluorescence of the AlC4Pc, with the maximum emission wavelength at 701 nm, could be quenched by TC16PyP at its proper concentration, but recovered by adding nucleic acids. Under optimal conditions, the recovered fluorescence is proportional to the concentration of nucleic acids. The calibration graphs are linear over the range of 1-200 ng mL−1 for fish sperm DNA (FS DNA) and 2-400 ng mL−1 for calf thymus DNA (CT DNA). The corresponding detection limits are 0.59 ng mL−1 for FS DNA and 0.82 ng mL−1 for CT DNA, respectively. Four synthetic and three real nucleic acid samples were determined with satisfactory results.  相似文献   

11.
Although there are a number of existing assays for monitoring the activity of both isopenicillin N synthase (IPNS) and deacetoxycephalosporin C synthase (DAOCS), none have demonstrated the qualities required for screening a mutant library. Hence, enzyme-linked immunosorbent assays (ELISAs) for IPNS and DAOCS were developed based on the detection of the catalytic turnover products isopenicillin N and cephalexin/phenylacetyl-7-aminodeacetoxycephalosporanic acid (G-7-ADCA), respectively. These assays are relatively fast compared to existing assays, such as the hole-plate bioassay, and are amenable with high-throughput screening. Both the IPNS and DAOCS-ELISAs were optimised for use with crude protein extracts rather than purified protein, thereby eliminating any additional time required for purification. The ELISA developed for the detection of cephalexin had an IC50 value of 154 ± 9 ng mL−1 and LOD of 7.2 ± 2.2 ng mL−1 under conditions required for the assay. Good recoveries and correlation was observed for spiked samples when the concentration of crude protein was kept below 1 mg mL−1. The DAOCS-ELISA was found to have increased sensitivity compared to the hole-plate bioassay (10.3 μg mL−1). The IPNS-ELISA did not significantly increase the sensitivity (approximately 5 μg mL−1) compared to that of the hole-plate bioassay (16 μg mL−1) for isopenicillin N. The minimum amount of crude protein extract required for producing detectable amounts of product for both assays was below 0.5% of the maximum amount of protein that the assay could contain without any effect on the ELISA. This suggests that when screening a mutant library, mutants producing low amounts of the product could still be detected using these assays.  相似文献   

12.
The present article reports on the application of modified multiwalled carbon nanotubes (MMWCNTs) as a new, easily prepared and stable solid sorbent for the preconcentration of trace rhodium ion in aqueous solution. Rhodium ions were complexed with 1-(2-pyridylazo)-2-naphthol (PAN) in the pH range of 3.2-4.7 and then the formed Rh-PAN complex was adsorbed on the oxidized MWCNTs. The adsorbed complex was eluted from MWCNTs sorbent with 5.0 mL of N,N-dimethylformamide (DMF). The rhodium in eluted solution was determined by flame atomic absorption spectrometry (FAAS). Linear range for the determination of rhodium was maintained between 0.16 ng mL−1 and 25.0 μg mL−1 in initial solution. Relative standard deviation for the 10 replicated determination of 4.0 μg mL−1 of rhodium was ±0.97%. Detection limit was 0.010 ng mL−1 in initial solution (3Sbl, n = 10) and preconcentration factor was 120. Sensitivity for 1% absorbance of rhodium (III) was 0.112 μg mL−1. The sorption capacity of oxidized MWCNTs for Rh (III) was 6.6 mg g−1. The effects of the experimental parameters, including the sample pH, flow rates of sample and eluent solution, eluent type, breakthrough volume and interference ions were studied for the preconcentration of Rh3+. The proposed method was successfully applied to the extraction and determination of rhodium in different samples.  相似文献   

13.
Potassium formate was extracted from airport storm water runoff by headspace solid-phase microextraction (HS-SPME) and analyzed by GC–MS. Formate was transformed to formic acid by adding phosphoric acid. Subsequently, formic acid was derivatized to methyl formate by adding methanol. Using sodium [2H]formate (formate-d) as an internal standard, the relative standard deviation of the peak area ratio of formate (m/z 60) and formate-d (m/z 61) was 0.6% at a concentration of 208.5 mg L−1. Calibration was linear in the range of 0.5–208.5 mg L−1. The detection limit calculated considering the blank value was 0.176 mg L−1. The mean concentration of potassium formate in airport storm water runoff collected after surface de-icing operations was 86.9 mg L−1 (n = 11) with concentrations ranging from 15.1 mg L−1 to 228.6 mg L−1.  相似文献   

14.
A multicommuted flow system is proposed for spectrophotometric determination of hydrosoluble vitamins (ascorbic acid, thiamine, riboflavine and pyridoxine) in pharmaceutical preparations. The flow manifold was designed with computer-controlled three-way solenoid valves for independent handling of sample and reagent solutions and a multi-channel spectrophotometer was employed for signal measurements. Periodic re-calibration as well as the standard addition method was implemented by using a single reference solution. Linear responses (r=0.999) were obtained for 0.500-10.0 mg l−1 ascorbic acid, 2.00-50.0 mg l−1 thiamine, 5.00-50.0 mg l−1 riboflavine and 0.500-8.00 mg l−1 pyridoxine. Detection limits were estimated as 0.08 mg l−1 (0.5 μmol l−1) ascorbic acid, 0.8 mg l−1 (2 μmol l−1) thiamine, 0.2 mg l−1 (0.5 μmol l−1) riboflavine and 0.1 mg l−1 (0.9 μmol l−1) pyridoxine at 99.7% confidence level. A mean sampling rate of 60 determinations per hour was achieved and coefficients of variation of 1% (n=20) were estimated for all species. The mean reagent consumption was 25-fold lower in relation to flow-based procedures with continuous reagent addition. Average recoveries between 95.6 and 100% were obtained for commercial pharmaceutical preparations. Results agreed with those obtained by reference methods at 95% confidence level. The flow system is suitable for application in quality control processes and in dissolution studies of vitamin tablets.  相似文献   

15.
A novel amperometric uric acid (UA) sensor has been developed by coating the surface of a gold electrode with a polystyrene (PS) membrane formed by 30 μL of a 30 mg mL−1 PS chloroform solution combined with 30 μL of a 5 mg mL−1 polymaleimidostyrene (PMS) solution as a dispersant for enzyme, uricase; this membrane has been successfully employed as an immobilization support for uricase. In the PS membrane, PMS forms micelle-like structures containing uricase in an active state. This immobilized uricase membrane permits the permeation of oxygen, which is consumed by the uricase reaction. A good linear relationship is obtained over the concentration range of 5-105 μM. The concentration of uric acid was determined at a negative potential based on the decrease in the reduction current of oxygen and the interference of l-ascorbic acid can be completely eliminated.  相似文献   

16.
Yi Wan  Dun Zhang  Baorong Hou 《Talanta》2010,82(4):1608-1611
A fast, sensitive and reliable potentiometric stripping analysis (PSA) is described for the selective detection of the marine pathogenic sulfate-reducing bacterium (SRB), Desulforibrio caledoiensis. The chemical and electrochemical parameters that exert influence on the deposition and stripping of lead ion, such as deposition potential, deposition time and pH value were carefully studied. The concentration of SRB was determined in acetate buffer solution (pH 5.2) under the optimized condition (deposition potential of −1.3 V, deposition time of 250 s, ionic strength of 0.2 mol L−1 and oxidant mercury (II) concentration of 40 mg L−1). A linear relationship between the stripping response and the logarithm of the bacterial concentration was observed in the range of 2.3 × 10 to 2.3 × 107 cfu mL−1. In addition, the potentiometric stripping technique gave a distinct response to the SRB, but had no obvious response to Escherichia coli. The measurement system has a potential for further applications and provides a facile and sample method for detection of pathogenic bacteria.  相似文献   

17.
A simple and rapid method based on solid-phase micro extraction (SPME) technique followed by gas chromatography-mass spectrometry with selected ion monitoring (GC-MS, SIM) was developed by the simultaneous determination of 16 pesticides of seven different chemical groups [Six organophosphorus (trichlorfon, diazinon, methyl parathion, malathion, fenthion and ethyon), three pyrethroids (bifenhin, permethrin, cypermethrin), two imidazoles (imazalil and prochloraz), two strobilurins (azoxystrobin and pyraclostrobin), one carbamate (carbofuran), one tetrazine (clofentezine), and one triazole (difenoconazole)] in water. The pesticides extraction was done with direct immersion mode (DI-SPME) of the polyacrilate fiber (PA 85 µm). The extraction temperature was adjusted to 50 °C during 30 min, while stirring at 250 rpm was applied. After extraction, the fiber was introduced in the GC injector for thermal desorption for 5 min. at 280 °C. The method was validated using ultra pure water samples fortified with pesticides at different concentration levels and shows good linearity in the concentrations between 0.05 and 250.00 ng mL− 1. The LOD and LOQ ranged, from 0.02 to 0.30 ng mL− 1 and 0.05 to 1.00 ng mL− 1, respectively. Intra-day and inter-day precisions were determined in two concentration levels (5.00 and 50.00 ng mL− 1). Intra-day relative standard deviation (%R.S.D.) ranged between 3.6 and 13.6%, and inter-day (%R.S.D.) ranged between 6.3 and 18.5%. Relative recovery tests were carried out spiking the ultra pure sample with standards in three different concentration levels 0.20, 5.00 and 50.00 ng mL− 1. The recovery at 0.20 ng mL− 1 level varied from 86.4 ± 9.4% to 108.5 ± 10.5%, at 5.00 ng mL− 1 level varied from 77.5 ± 10.8% to 104.6 ± 9.6% and at 50.00 ng mL− 1 level varied from 70.2 ± 4.6% to 98.4 ± 8.5%. The proposed SPME method was applied in twenty-six water samples collected in the “Platô de Neópolis”, State of Sergipe, Brazil. Methyl parathion was detected in five samples with an average concentration of 0.17 ng mL− 1 and bifenthrin, pyraclostrobin and azoxystrobin residues were found in three samples with average concentrations of 2.28, 3.12 and 0.15 ng mL− 1, respectively.  相似文献   

18.
Enriching the surface density of immobilized capture antibodies enhances the detection signal of antibody sandwich microarrays. In this study, we improved the detection sensitivity of our previously developed P-Si (porous silicon) antibody microarray by optimizing concentrations of the capturing antibody. We investigated immunoassays using a P-Si microarray at three different capture antibody (PSA – prostate specific antigen) concentrations, analyzing the influence of the antibody density on the assay detection sensitivity. The LOD (limit of detection) for PSA was 2.5 ng mL−1, 80 pg mL−1, and 800 fg mL−1 when arraying the PSA antibody, H117 at the concentration 15 μg mL−1, 35 μg mL−1, and 154 μg mL−1, respectively. We further investigated PSA spiked into human female serum in the range of 800 fg mL−1 to 500 ng mL−1. The microarray showed a LOD of 800 fg mL−1 and a dynamic range of 800 fg mL−1 to 80 ng mL−1 in serum spiked samples.  相似文献   

19.
A simple, automatic and practical system for successive determination of albumin and creatinine has been developed by combining sequential injection analysis (SIA) and highly sensitive dye-binding assays. Albumin detection was based on the increase in the absorbance due to complex formation between albumin and eosin Y in acidic media. The absorbance of the complex was monitored at 547 nm. For the creatinine assay, the concentration of creatinine was measured by reaction with alkaline picrate to form a colored product which absorbs at 500 nm. The influences of experimental variables such as effects of pH, reagent concentration, standard/sample volume and interferences were investigated. Under optimal conditions, the automated method showed linearity up to 20 mg L−1 for albumin and 100 mg L−1 for creatinine. The 3σ detection limits were 0.6 and 3.5 mg L−1 for albumin and creatinine, respectively, and the relative standard deviations (n = 10) were 2.49% for 20 mg L−1 albumin, and 3.14% for 20 mg L−1 creatinine. Application of the proposed method to the direct analysis of urinary samples yielded results which agreed with those obtained from the Bradford protein assay and a creatinine enzymatic assay according to a paired t-test. The results obtained should be a step towards developing a fully automated and reliable analytical system for clinical research, which requires direct determination of albumin and creatinine and/or its ratios.  相似文献   

20.
New, simple, rapid and precise HPLC-PDA method has been developed and validated for quantification of biomarker myrsinoic acid B in stem bark extracts of Rapanea ferruginea Mez. The method employs a Phenomenex C18 column (250 mm × 4.6 mm I.D., 5 μm) with acetonitrile:methanol:water (pH 2.6 with phosphoric acid) at 48:30:22 as mobile phase, at a flow rate of 0.7 mL min−1 and photo diode array (PDA) detection at 270 nm. The validation data show that the method is specific, accurate, precise and robust. The method was linear, over a range of 5-100.0 μg mL−1, with a limit of detection of 0.369 μg mL−1 and limit of quantification of 1.233 μg mL−1. The method has also shown consistent recoveries (average of 101.3% and 0.12% RSD) of the biomarker, with low intra and inter-day relative standard deviation (1.26% and 1.62%, respectively). The evaluated hydroethanolic extract and dry extract presented MAB values of 63.53 and 36.07 mg g−1, respectively.  相似文献   