首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 847 毫秒
1.
The present paper describes the development and validation of a new reversed-phase liquid chromatography–electrospray ionization tandem mass spectrometric method (RP-HPLC–ESI-MS/MS) for simultaneous determination of pyridine, 2-picoline, 4-picoline and quinoline from mainstream cigarette smoke. Liquid–liquid extraction followed by solid-phase extraction was applied to extract the target analytes from cigarette smoke. Baseline chromatographic separation was achieved by utilizing a Zorbax SB-Aq (4.6 × 150 mm, 5 μm) column in gradient chromatographic conditions with acetonitrile and ammonium acetate buffer as mobile phases. Popular commercially available Indian brand filtered and non-filtered cigarettes were analyzed using the same method. The identification of each chemical was established by chromatographic retention times, analyte specific fragmentation patterns and relative peak area ratios of two product/precursor ion pairs. The limit of detection of this method ranged from 1.74 to 14.32 ng/cig using an injection volume of 20 μl. The reproducibility of this method is excellent and better standard deviations were obtained compared to literature reported values for these chemicals. RSD value is less than 9% for all analytes.  相似文献   

2.
In this study 5-hydroxymethyl-2-furaldehyde (HMF), 2-furaldehyde, 3-furaldehyde, 2-furoic acid and 3-furoic acid are contemporarily determined in honey using a swift and direct RP-HPLC approach. The validation protocol was performed in terms of detection and quantification limits, precision (by repeatability and reproducibility), linearity and accuracy (by recovery tests); the acceptability of the precision and accuracy results was positively verified using Horwitz's model and AOAC guidelines, respectively. The method was tested on 18 honey samples of different ages, and botanical and geographical origin. HMF and 2-furaldehyde correlated highly with the age of the samples, whereas no correlation was observed with regards to 2-furaldehyde and 2-furoic acid. Hypotheses relating to the formation of minority furanic compounds are also proposed.  相似文献   

3.
A gas chromatography–mass spectrometric method was developed in this study in order to determine fluoride in plasma and urine after derivatization with 2-(bromomethyl)naphthalene. 2-Fluoronaphthalene was chosen as the internal standard. The derivatization of fluoride was performed in the biological sample and the best reaction conditions (10.0 mg mL−1 of 2-(bromomethyl)naphthalene, 1.0 mg mL−1 of 15-crown-5-ether as a phase transfer catalyst, pH of 7.0, reaction temperature of 70 °C, and heating time of 70 min) were established. The organic derivative was extracted with dichloromethane and then measured by a gas chromatography–mass spectrometry. Under the established condition, the detection limits were 11 μg L−1 and 7 μg L−1 by using 0.2 mL of plasma or urine, respectively. The accuracy was in a range of 100.8–107.6%, and the precision of the assay was less than 4.3% in plasma or urine. Fluoride was detected in a concentration range of 0.12–0.53 mg L−1 in six urine samples after intake of natural mineral water containing 0.7 mg L−1 of fluoride.  相似文献   

4.
Fentanyl and 16 of its corresponding homologs and analogs were distinguished using ultra-high-pressure liquid chromatography–tandem mass spectrometry (UHPLC–MS/MS). A 1.7 μm Acquity BEH C18 column (150 mm × 2.1 mm) was used with a 1% formic acid (pH 2.2), methanol gradient. Multiple-reaction monitoring (MRM) was employed for MS/MS detection. All selected fentanyl-related compounds, including incompletely resolved compounds, were uniquely identified using retention times and dual MRMs.  相似文献   

5.
In recent years waterpipe smoking has spread worldwide and emerged as global health issue. Yet only little is known on the composition of waterpipe smoke. Here, we present a study on the identification and quantification of primary aromatic amines (PAAs) in this complex environmental matrix. Smoking of the waterpipe was conducted with a smoking machine and particulate matter was collected on glass fiber pads. We developed a fast, simple and specific liquid chromatography-electrospray ionization tandem mass spectrometry (LC-MS/MS) approach to simultaneously detect 31 different PAAs in this matrix. The detection limits comprised a range of 0.45-4.50 ng per smoking session, represented by 2-aminobiphenyl and 3,4,5-trichloroaniline, respectively. Intra- and inter-day precision were determined and proved excellent. We detected 31.3 ± 2.2 ng aniline and 28.0 ± 1.6 ng 4,4'-oxydianiline in the smoke of one waterpipe session. The water in the bowl exerted a small but considerable filter effect on PAAs. The method worked-out showed excellent sensitivity and specificity and is thus highly suited for the determination of PAAs in mainstream waterpipe smoke.  相似文献   

6.
In this work, a recently developed extraction technique for sample preparation aiming the analysis of volatile and semi-volatile compounds named gas-diffusion microextraction (GDME) is applied in the chromatographic analysis of aldehydes in beer. Aldehydes—namely acetaldehyde (AA), methylpropanal (MA) and furfural (FA)—were simultaneously extracted and derivatized with 2,4-dinitrophenylhydrazine (DNPH), then the derivatives were separated and analyzed by high-performance liquid chromatography with spectrophotometric detection (HPLC–UV). The identity of the eluted compounds was confirmed by high-performance liquid chromatography–atmospheric pressure chemical ionization–mass-spectrometry detection in the negative ion mode (HPLC–APCI–MS). The developed methodology showed good repeatability (ca. 5%) and linearity as well as good limits of detection (AA–12.3, FA–1.5 and MA 5.4 μg L−1) and quantification (AA–41, FA–4.9 and MA 18 μg L−1); it also appears to be competitive in terms of speed and cost of analysis.  相似文献   

7.
Tobacco-specific nitrosamines (TSNAs) are some of the most potent carcinogens in tobacco and cigarette smoke. Accurate quantification of these chemicals is needed to help assess public health risks. We developed and validated a specific and sensitive method to measure four TSNAs adsorbed to model surfaces and secondhand smoke (SHS) particles using gas chromatography–ion-trap tandem mass spectrometry. In an 18-m3 room-sized chamber, a smoking machine generated realistic concentrations of SHS that were actively sampled on Teflon-coated fiber glass (TCFG) filters, and passively sampled on cellulose substrates. A simple solid–liquid extraction protocol using methanol as solvent was successfully applied to both substrates with recoveries ranging from 85 to 115%. For each TSNA, tandem MS parameters were optimized and the major fragmentation pathways were elucidated. The method showed excellent performance, with a linear dynamic range from 2 to 1000 ng mL−1, low detection limits (S/N > 3) of 30–300 pg mL−1 and precision with experimental errors below 10% for all compounds. Moreover, no interfering peaks were observed, indicating a high selectivity of MS/MS without the need for a sample clean-up step. This method provides a suitable analytical tool to detect and quantify traces of TSNA in indoor environments polluted with SHS.  相似文献   

8.
A novel and highly selective method has been developed for the determination of aromatic primary amines by their conversion to dithiocarbamates by reaction with carbon disulphide, and then to isothiocyanates, which are volatile, by heating in the presence of a heavy metal ion. Zinc(II) was selected owing to its low toxicity and optimum yield of isothiocyanates. The latter were sampled by headspace-solid phase microextraction (HS-SPME) on divinylbenzene-carboxen-polydimethylsiloxane fibre, 50/30 μm. The HS-SPME procedure was optimized to provide adequate limits of detection in the analysis of aromatic amines in their real samples by gas chromatography with mass spectrometry (GC–MS) or flame ionization detection (GC–FID). The method gave rectilinear calibration graph, correlation coefficient and limit of detection, respectively, over the range 0.08–100 μg L−1, 0.9950–0.9990 and 25–240 ng L−1 in gas chromatography–mass spectrometry, and 0.01–10 mg L−1, 0.9910–0.9991 and 0.8–3.0 μg L−1 in gas chromatography–flame ionization detection. At two different levels, 10 and 40 μg L−1, the range of intra-day RSD was 3.7–8.5% (GC–MS) and 3.3–9.2% (GC–FID), respectively. The proposed method is simple and rapid, and has been applied to determine aromatic primary amines in the environmental waters, food samples of ice cream powder and soft drinks concentrate, and food colours. The intra-day RSD in the analysis of real samples by GC–MS was in the range 3.6–6.2%. The food/colour samples were found to contain elevated levels of aniline and 2-toluidine.  相似文献   

9.
A method for the determination of 2-furaldehyde (F) and 5-hydroxymethyl-2-furaldehyde (HMF) in alcoholic beverages by high performance liquid chromatography (HPLC) is described. A C-18 column and an acetonitrile-water mobile phase with isocratic elution were used. UV detection at 280 nm was carried out. The method was validated according to the EURACHEM guidelines. The procedure offers a high specificity and detection limits of the order of 0.005 μg mL− 1. Recoveries of 94-103% were obtained from spiked samples at different levels with both analytes. Intermediate precision calculated for a period of 2 months was + 0.8% for HMF and + 0.4% for F. The method was applied to the analysis of alcoholic beverages like bourbon, rum, brandy, liquors and aperitif wines.  相似文献   

10.
A simple, fast and sensitive liquid chromatography–electrospray tandem mass spectrometry method was established for trace levels of nine haloacetic acids (HAAs) in drinking water. Water samples were removed of residual chlorine by adding l-ascorbic acid, and directly injected after filtered by 0.22 μm membrane. Nine HAAs were separated by liquid chromatography in 7.5 min, and the limits of detection were generally between 0.16 and 0.99 μg/L except for chlorodibromoacetic acid (1.44 μg/L) and tribromoacetic acid (8.87 μg/L). The mean recoveries of nine target compounds in spiked drinking water samples were 80.1–108%, and no apparent signal suppression was observed. Finally, this method was applied to determine HAAs in the tap water samples collected from five waterworks in Shandong, China. Nine HAAs except for monochloroacetic acid, monobromoacetic acid, dibromochloroacetic acid and tribromoacetic acid were detected, and the total concentrations were 7.79–36.5 μg/L. The determination results well met the first stage of the Disinfectants/Disinfection By-Products (D/DBP) Rules established by U.S.EPA and Guidelines for Drinking-water Quality of WHO.  相似文献   

11.
A simple method for the analysis of capsaicin and dihydrocapsaicin in peppers and pepper sauces by solid phase microextraction–gas chromatography–mass spectrometry has been developed. A novel device was designed for direct extraction solid phase microextraction in order to avoid damage to the fiber. The analysis was performed without derivatization for the gas chromatography–mass spectrometry analysis. Selection fiber, extraction temperature, extraction time and pH, were optimized. The method was linear in the range 0.109–1.323 μg/mL for capsaicin and 0.107–1.713 μg/mL for dihydrocapsaicin with correlation coefficient up to r = 0.9970 for both capsaicinoids. The precision of the method was less than 10%. The method was applied to the analysis of 11 varieties of peppers and four pepper sauces. A broad range of capsaicin (55.0–25 459 μg/g) and dihydrocapsaicin (93–1 130 μg/g) was found in the pepper and pepper sauces samples (4.3–717.3 and 1.0–134.8 μg/g), respectively.  相似文献   

12.
A simple and rapid extraction procedure was developed for determining aldehydes in rainwater samples. This extraction technique involved the use of micro-solid-phase extraction in which the sorbent was held within a polypropylene membrane envelope, followed by high-performance liquid chromatographic analysis. Aldehydes such as formaldehyde, acetaldehyde, propionaldehyde and valeraldehyde were used as model compounds. Extraction conditions were optimized. The method linearity ranged between 0.5 and 50 μg l−1 with the correlation coefficient of 0.987–0.999. The relative standard deviations (RSDs) of the method ranged from 7 to 12%. Method detection limits were in the range of 0.07–0.15 μg l−1, which is lower than those previously reported for solid-phase microextraction combined with gas chromatography–mass spectrometric techniques. The proposed extraction technique was used for determination of aldehydes in rainwater samples to demonstrate the applicability of the method.  相似文献   

13.
In this work, a new stir cake sorptive extraction (SCSE) using polymeric ionic liquid monolith as sorbent was prepared. The sorbent was obtained by in situ copolymerization of an ionic liquid, 1-allyl-3-methylimidazolium bis[(trifluoro methyl)sulfonyl]imide (AMII) and divinylbenzene (DB) in the presence of N,N-dimethylformamide. The influence of the content of ionic liquid and the porogen in the polymerization mixture on extraction performance was studied thoroughly. The physicochemical properties of the polymeric ionic liquid were characterized by infrared spectroscopy, elemental analysis, scanning electron microscopy and mercury intrusion porosimetry. The usefulness of SCSE–AMIIDB was demonstrated by the enrichment of trace benzimidazole anthelmintics. Several parameters affecting the extraction efficiency were investigated, and under the optimized conditions, a simple and effective method for the determination of trace benzimidazoles residues in water, milk and honey samples was established by coupling SCSE–AMIIDB with high performance liquid chromatography/diode array detection (SCSE–AMIIDB–HPLC/DAD). Results indicated that the limits of detection (S/N = 3) for target compounds were 0.020–0.072 μg L−1, 0.035–0.10 μg L−1 and 0.026–0.076 μg L−1 in water, milk and honey samples, respectively. In addition, an acceptable reproducibility was achieved by evaluating the repeatability and intermediate precision with relative standard deviations (RSD) of less than 9% and 11%, respectively. Finally, the established AMII–SCSE–HPLC/DAD method was successfully applied for the determination of benzimidazoles residues in milk, honey and environmental water samples. Recoveries obtained for the determination of benzimidazole anthelmintics in spiking samples ranged from 70.2% to 117.6%, with RSD below 12% in all cases.  相似文献   

14.
In this work, a headspace-solid-phase micro-extraction (HS-SPME) combined with gas chromatography–mass spectrometry (GC–MS) method for multielemental speciation of organometallic compounds of mercury, lead and tin in water samples was upgraded by the introduction of tandem mass spectrometry (MS/MS) as detection technique. The analytical method is based on the ethylation with NaBEt4 and simultaneous headspace-solid-phase micro-extraction of the derivative compounds followed by GC–MS/MS analysis. The main experimental parameters influencing the extraction efficiency such as derivatisation time, extraction time and extraction temperature were optimized. The overall optimum extraction conditions were the following: a 50 μm/30 μm divinyl-benzene/carboxen/polydimethylsiloxane (DVB/CAR/PDMS) SPME fibre, 150 min derivatisation time, 15 min extraction time, sample agitation at 250 rpm and 40 °C extraction temperature. The analytical characteristics of the HS-SPME method combined with GC–MS and GC–MS/MS were evaluated. The combination of both techniques HS-SPME and GC–MS/MS allowed to attain lower limits of detection (4–33 ng l−1) than those obtained by HS-SPME–GC–MS (17–45 ng l−1). The proposed method presented good linear regression coefficients (r2 > 0.9970) and repeatability (4.8–21.0%) for all the compounds under study. The accuracy of the method measured as the average percentage recovery of the compounds in spiked river water and seawater samples was higher than 80% for all the compounds studied, except for monobutyltin in the river water sample. A study of the uncertainty associated with the analytical results was also carried out.  相似文献   

15.
Tenuazonic acid (TA) is a major Alternaria mycotoxin. In the present work a novel approach for the detection of TA in cereals by liquid chromatography–ion-trap multistage mass spectrometry after derivatization with 2,4-dinitrophenylhydrazine is described. The product of the derivatization reaction and its major MS2 fragments were characterised by Fourier transform-ion cyclotron resonance tandem mass spectrometry. Without preconcentration, the established method features a limit of detection of 10 μg/kg using 2 g of sample in a rapid workup procedure. Accuracy, precision and linearity were evaluated in the working range of 50–5000 μg/kg. TA was detected in 13 and quantified in 3 out of 27 cereal samples obtained from a local supermarket, the average content being 49 μg/kg (highest incidence: 851 ± 41 μg/kg).  相似文献   

16.
Mutagenic and carcinogenic heterocyclic amines (HCAs) are formed during heating of various proteinaceous foods, but human exposure to HCAs has not yet been elucidated in detail. To assess long-term exposure to HCAs, we developed a simple and sensitive method for measuring HCAs in hair by automated on-line in-tube solid-phase microextraction (SPME) coupled with liquid chromatography–tandem mass spectrometry (LC–MS/MS). Using a Zorbax Eclipse XDB-C8 column, 16 HCAs were analyzed within 15 min. The optimum in-tube SPME conditions were 20 draw/eject cycles of 40 μL sample at a flow rate of 200 μL min−1 using a Supel-Q PLOT capillary column as an extraction device. The extracted HCAs were easily desorbed from the column by passage of the mobile phase, with no carryover observed. This in-tube SPME LC–MS/MS method showed good linearity for HCAs in the range of 10–2000 pg mL−1, with correlation coefficients above 0.9989 (n = 18), using stable isotope-labeled HCA internal standards. The detection limits (S/N = 3) of 14 HCAs except for MeAαC and Glu-P-1 were 0.10–0.79 pg mL−1. This method was successfully utilized to analyze 14 HCAs in hair samples without any interference peaks, with quantitative limits (S/N = 10) of about 0.17–1.32 pg mg−1 hair. Using this method, we evaluated the exposure to HCAs in cigarette smoke and the suitability of using hair HCAs as exposure biomarkers.  相似文献   

17.
Estrone (E1), estradiols (α/β-E2), and estriol (E3) are four major metabolically active estrogens exerting strong biological activities at very low circulating concentrations. This paper reports a sensitive and efficient method with automated, on-line clean-up and detection to determine trace estrogens in a small volume of serum samples using liquid chromatography–electrospray ionization–tandem mass spectrometry directly, without off-line liquid–liquid or solid-phase extraction pretreatments. Serum aliquots (charcoal stripped fetal bovine serum, 100 μL) were spiked with four estrogen standards and their corresponding isotope-labeled internal standards, then bulk derivatized with 2-fluoro-1-methyl-pyridium p-toluenesulfonate (2-FMP) to establish the calibration curves and perform method validation. Calibration was established in the concentration ranges of 5–1000 pg mL−1, and demonstrated good linearity of R2 from 0.9944 to 0.9997 for the four derivatized estrogens. The lower detection limits obtained were 3–7 pg mL−1. Good accuracy and precision in the range of 86–112% and 2.3–11.9%, respectively, were observed for the quality control (QC) samples at low, medium, and high concentration levels. The stability tests showed that the derivatized serum samples were stable 8 h after derivatization at room temperature and at least to 48 h if stored at −20 °C. The method was applied to measure trace estrogens in real human and bovine serum samples, and three of four estrogen compounds studied were observed and quantified.  相似文献   

18.
A gas chromatography–tandem mass spectrometric (GC–MS/MS) method has been established for the determination of cyanide in surface water. This method is based on the derivatization of cyanide with 2-(dimethylamino)ethanethiol in surface water. The following optimum reaction conditions were established: reagent dosage, 0.7 g L−1 of 2-(dimethylamino)ethanethiol; pH 6; reaction carried out for 20 min at 60 °C. The organic derivative was extracted with 3 mL of ethyl acetate, and then measured by using GC–MS/MS. Under the established conditions, the detection and quantification limits were 0.02 μg L−1 and 0.07 μg L−1 in 10-mL of surface water, respectively. The calibration curve had a linear relationship relationship with y = 0.7140x + 0.1997 and r2 = 0.9963 (for a working range of 0.07–10 μg L−1) and the accuracy was in a range of 98–102%; the precision of the assay was less than 7% in surface water. The common ions Cl, F, Br, NO3, SO42−, PO43−, K+, Na+, NH4+, Ca2+, Mg2+, Ba2+, Mn4+, Mn2+, Fe3+, Fe2+ and sea water did not interfere in cyanide detection, even when present in 1000-fold excess over the species. Cyanide was detected in a concentration range of 0.07–0.11 μg L−1 in 6 of 10 surface water samples.  相似文献   

19.
A sensitive method was developed for the trace determination of six tetracyclines and ten of their degradation products in influent, effluent, and river waters using liquid chromatography–electrospray tandem mass spectrometry detection, combined with Oasis hydrophilic–lipophilic balance (HLB) cartridge extraction and Oasis mixed-mode strong anion exchange (MAX) cartridge cleanup. Tetracyclines and their products were separated by liquid chromatography in 9.5 min, and the instrument detection limits were generally between 0.03 and 0.1 μg/L except for minocycline (0.5 μg/L). The chromatograms were improved through the MAX cleanup and no apparent matrix effect was found. The recoveries of all the target compounds except for 4-epianhydrochlortetracycline and anhydrochlortetracycline (34–52%) were 75–120% for influent, 61–103% for effluent, and 64–113% for river waters. The method detection limits (MDLs) of the analytes varied in the range of 0.8–17.5 ng/L in all studied matrices. The method was applied for the determination of tetracyclines and their products in a sewage treatment plant (STP) and surface waters in Beijing, China. Oxytetracycline (3.8–72.5 ng/L), tetracycline (1.9–16.5 ng/L), and five products including 4-epitetracycline, 4-epioxytetracycline, isochlortetracycline, anhydrotetracycline, and 4-epianhydrochlortetracycline (5.7–25.3 ng/L) were detected in wastewater, while only oxytetracycline and tetracycline (2.2 and 2.1 ng/L) were detected in surface water samples.  相似文献   

20.
In the study, a kind of novel styrene-co-4-vinylpyridine (St-co-4-VP) porous magnetic polymer beads was prepared by microwave irradiation using suspension polymerization. Microwave heating preparation greatly reduced the polymerization time to 1 h. Physical characteristic tests suggested that these beads were cross-linking and possessed spherical shape, good magnetic response and porous morphologies with a narrow diameter distribution of 70–180 μm. Therefore, these beads displayed the long-term stability after undergoing 100-time extractions. Then, an analytical method for the determination of trace 24-epiBR in plant samples was developed by magnetic polymer bead extraction coupled with high performance liquid chromatography–fluorescence detection. St-co-4-VP magnetic polymer beads demonstrated the higher extraction selectivity for 24-epiBR than other reference compounds. Linear range was 10.00–100.0 μg/L with a relative standard deviation (RSD) of 6.7%, and the detection limit was 6.5 μg/kg. This analytical method was successfully applied to analyze the trace 24-epiBR in cole and breaking-wall rape pollen samples with recoveries of 77.2–90.0% and 72.3–83.4%, respectively, and RSDs were less than 4.1%. The amount of 24-epiBR in real breaking-wall rape pollen samples was found to be 26.2 μg/kg finally. This work proposed a sensitive, rapid, reliable and convenient analytical method for the determination of trace brassinosteroids in complicated plant samples by the use of St-co-4-VP magnetic polymer bead extraction coupled with chromatographic method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏