首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) has been one of the most powerful tools for analyzing protein phosphorylation. However, it is frequently difficult to detect phosphopeptides with high sensitivity by MALDI-MS. In our investigation of matrix/matrix-additive substances for improving the phosphopeptide ion response in MALDI-MS, we found that the addition of low-concentration alkylphosphonic acid to the matrix/analyte solution significantly enhanced the signal of phosphopeptides. In this study, the combination of methanediphosphonic acid and 2,5-dihydroxybenzoic acid gave the best results. In addition to enhancing the signal of the phosphopeptides, alkylphosphonic acid almost completely eliminated the signals of sodium and potassium ion adducts. We report herein sensitive detection of phosphopeptides by MALDI-MS with the use of alkylphosphonic acids as matrix additives.  相似文献   

2.
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is a powerful tool for the analysis and characterization of protein phosphorylation on the peptide level. In this study, the applicability of ionic liquid matrices (ILM) formed by combination of the crystalline MALDI matrix 2,5-dihydroxybenzoic acid (DHB) with pyridine or n-butylamine was tested for the analysis of phosphopeptides. Low ionization efficiency in both positive and negative ion mode was observed in acid-free sample preparations. Upon addition of 0.1% trifluoroacetic acid (TFA), ion formation was increased, but analogously to the situation described earlier for pure DHB, best results were obtained upon use of 1% phosphoric acid as matrix additive. The samples prepared in this way were significantly more homogeneous than preparations with pure DHB, thus avoiding the need for time-consuming search for hot spots. Other characteristics like metastable fragmentation of phosphopeptides did not differ from that observed in classical preparations. The limits of detection for synthetic phosphopeptides and singly or multiply phosphorylated peptides from tryptic digests of alpha- and beta-casein were comparable with those obtained when using pure DHB; in some cases even higher signal intensities could be observed in the ILM. The use of ILM in combination with 1% phosphoric acid as matrix additive significantly facilitates analysis of phosphopeptides by MALDI-MS.  相似文献   

3.
There have been many successful efforts to enrich phosphopeptides in complex protein mixtures by the use of immobilized metal affinity chromatography (IMAC) and/or metal oxide affinity chromatography (MOAC) with which mass spectrometric analysis of phosphopeptides has become state of the art in specialized laboratories, mostly applying nanoLC electrospray ionization mass spectrometry-based investigations. However, widespread use of these powerful techniques is still not achieved. In this study, we present a ready-to-use phosphopeptide enrichment procedure using commercially available TiO(2)-loaded pipette tips in combination with matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) analyses. Using α-casein as a model protein and citric acid as additive during sample loading, a similar enrichment success can be achieved as compared to applying 2,5- dihydroxy benzoic acid (DHB) for this task. But the DHB-inherited drawbacks are eliminated. In addition, we show that combining DHB and 2,4,6-trihydroxy acetophenone (THAP) as matrix for MALDI-MS measurements retains the sensitivity of DHB for phosphopeptide analysis but adds the homogenous crystallization properties of THAP, enabling preparation of evenly distributed matrix surfaces on MALDI-MS anchor targets, a prerequisite for automated MALDI- MS analyses. Tripartite motif-containing protein 28 and stathmin are two examples for which successful phosphopeptide enrichment of either sodium dodecyl sulfate polyacrylamide gel electrophoresis or two-dimensional gel electrophoresis-separated proteins is shown. Finally, high resolution MALDI Fourier transform ion cyclotron resonance mass spectrometry after phosphopeptide enrichment suggests that chemical dephosphorylation may occur as a side reaction during basic elution of phosphopeptides bound to MOAC surfaces, suggesting that proteome-wide phosphopeptide analyses ought to be interpreted with caution. In contrast, in-depth analysis of phosphopeptide/non-phosphorylated peptide siblings may be used to estimate stability differences of phosphorylation sites in individual proteins, possibly adding valuable information on biological regulation processes.  相似文献   

4.
The effectiveness of a novel binary matrix composed of 1,8-bis(dimethylamino)naphthalene (DMAN; proton sponge) and 9-aminoacridine (9AA) for the direct lipid analysis of whole bacterial cells by matrix assisted laser desorption ionization mass spectrometry (MALDI MS) is demonstrated. Deprotonated analyte signals nearly free of matrix-related ions were observed in negative ion mode. The effect of the most important factors (laser energy, pulse voltage, DMAN/9AA ratio, analyte/matrix ratio) was investigated using a Box–Behnken response surface design followed by multi-response optimization in order to simultaneously maximize signal-to-noise (S/N) ratio and resolution. The chemical surface composition of single or mixed matrices was explored by X-ray photoelectron spectroscopy (XPS). Moreover, XPS imaging was used to map the spatial distribution of a model phospholipid in single or binary matrices.  相似文献   

5.
The ionization of phosphorylated peptides in positive ion mode mass spectrometry is generally less efficient compared with the ionization of their non-phosphorylated counterparts. This can make phosphopeptides much more difficult to detect. One way to enhance the detection of phosphorylated proteins and peptides is by selectively isolating these species. Current approaches of phosphopeptide isolation are based on the favorable interactions of phosphate groups with immobilized metals. While these methods can be effective in the extraction, they can lead to incomplete sample recovery, particularly for the most strongly bound multiply phosphorylated components. A non-sorptive method of phosphopeptide isolation using capillary electrophoresis (CE) was recently reported [Zhang et al., Anal. Chem. 77 (2005) 6078]. The relatively low isoelectric points of phosphopeptides cause them to remain anionic at acidic sample pH. Hence, they can be selectively injected into the capillary by an applied field after the electroosmotic flow (EOF) is suppressed. The technique was previously coupled with matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). In this work, the exploitation of selective sampling in conjugation with electrospray ionization mass spectrometry (ESI-MS) is presented. The transition was not immediately straightforward. A number of major alterations were necessary for ESI interfacing. These adaptations include the choice of a suitable capillary coating for EOF control and the incorporation of organic solvent for efficient ESI. As expected, selective injection of phosphopeptides greatly enhanced the sensitivity of their detection in ESI-MS, particularly for the multiply phosphorylated species that were traditionally most problematic. Furthermore, an electrophoretic separation subsequent to the selective injection of the phosphopeptides was performed prior to analysis by ESI-MS. This allowed us to resolve the multiply phosphorylated peptides present in the samples, predominantly based on the number of phosphorylation sites on the peptides.  相似文献   

6.
Kailasa SK  Wu HF 《The Analyst》2012,137(7):1629-1638
The sensitivity and efficiency of SALDI-MS or MALDI-MS is mainly dependent on the nature of matrix. A novel approach is proposed for one-pot synthesis of dopamine dithiocarbamate-functionalized gold nanoparticles (DDTC-Au NPs). Their application to quantification of small molecules by surface assisted laser desorption/ionization time-of-flight mass spectrometry (SALDI-TOF-MS) and rapid identification of phosphopeptides by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) is investigated. The synthesized DDTC-Au NPs were characterized by UV-visible and FT-IR spectroscopy, H(1)NMR, SEM and TEM. DDTC-Au NPs offers marked improvement on analyte ionization and effectively suppressed the background noise which leads to clean mass spectra. We also demonstrated the use of DDTC-Au NPs as affinity probes for selective enrichment of phosphopeptides from the solutions of microwave tryptic digested casein proteins. Compared with a conventional matrix, DDTC-Au NPs exhibited a high desorption/ionization efficiency for accurate quantification of small molecules including amino acid (glutathione), drugs (desipramine and enrofloxacin) and peptides (valinomycin and gramicidin D) and successfully utilized as novel affinity probes for straightforward and rapid identification of phosphopeptides from casein proteins (α-, β-casein and nonfat milk), showing a great potentiality to the real-time analysis.  相似文献   

7.
报道以2-氨基-5-硝基吡啶为基体用基体辅助激光解吸/电离质谱法(MALDI-MS)对DNA样品进行测定并研究它们的激光质谱特征,结果表明,2-氨基-5-硝基吡啶是DNA的一高效基体.用柠檬酸铵和NH_4~+阳离子交换树脂除去试剂和样品中的碱金属离子,能显著地提高解吸/电离DNA分子的效率.  相似文献   

8.
The analysis of oligonucleotides using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) has led to the investigation of the use of matrix additives (i.e., co-matrices) to help improve the poor spectral quality commonly observed during the analysis of this class of compounds. The use of certain matrix additives in MALDI-MS has been investigated previously, and these additives have been shown to enhance the desorption/ionization efficiency of oligonucleotides during the MALDI experiment. Specifically, amine bases, such as piperidine, imidazole, and triethylamine, have been shown to improve mass spectral quality as assessed by improved molecular ion resolution and increased molecular ion abundance. These improvements occur due to competition between the oligonucleotide and the co-matrix for protons generated during the MALDI event. Co-matrices with proton affinities near or above the proton affinities of the nucleotide residues serve as proton sinks during the desorption/ionization process. In this work, we have investigated the use of polyamines as co-matrices for MALDI mass spectrometric analysis of oligonucleotides. Spermine tetrahydrochloride, spermine, spermidine trihydrochloride, and spermidine were evaluated for their effectiveness at enhancing the mass spectral quality of oligonucleotides analyzed using MALDI-MS. The solution-phase pK( b) values and the gas-phase proton affinities of these polyamines were determined, and it was found that the polyamines appear to be more basic than the monofunctional amines investigated previously. The mass spectral data shows that spermidine and spermine are extremely effective co-matrices, yielding improved molecular ion resolution and molecular ion abundances. The spermine co-matrices are more effective than the spermidine co-matrices, but adduction problems with the spermine co-matrices limits their overall utility. In general, polyamine co-matrices are found to be more effective than monofunctional amine co-matrices at improving the mass spectral data obtained during MALDI-MS of oligonucleotides.  相似文献   

9.
A method of direct lipid analysis by matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) in intact membranes, without prior extraction/separation steps, is described. Here, we demonstrate the efficacy of a strong base, 1,8-bis(dimethylamino)naphthalene (DMAN; proton sponge), as a novel matrix for MALDI-time-of-flight (TOF) MS analysis of whole cell bacteria. Initially, individual acidic low-molecular-weight analytes such as standard free fatty acids and phospholipids were analyzed using DMAN as matrix. Clear negative-mode MALDI-TOF MS spectra of all analytes show only deprotonated analyte signals at a low picomole limit of detection with the complete absence of matrix-related signals. These results indicate that DMAN represents a suitable matrix for MALDI-TOF MS analysis of mixtures of complex lipids as the intact membranes of microorganisms. DMAN was successfully applied to the analysis of Lactobacillus sanfranciscensis and L. plantarum microorganisms. Different components were sensitively detected in a single spot, including 16:0, 18:2, 18:3, and 21:0 free acids, glycolipids, phosphatidylglycerols (PGs) and cardiolipins. This method might be of general application, offering the advantage of quickly gaining information about lipid components of other gram-positive bacterial membranes.  相似文献   

10.
Application of matrix‐assisted laser‐desorption/ionization mass spectrometry (MALDI MS) to analysis and characterization of phosphopeptides in peptide mixtures may have a limitation, because of the lower ionizing efficiency of phosphopeptides than nonphosphorylated peptides in MALDI MS. In this work, a binary matrix that consists of two conventional matrices of 3‐hydroxypicolinic acid (3‐HPA) and α‐cyano‐4‐hydroxycinnamic acid (CCA) was tested for phosphopeptide analysis. 3‐HPA and CCA were found to be hot matrices, and 3‐HPA not as good as CCA and 2,5‐dihydroxybenzoic acid (DHB) for peptide analysis. However, the presence of 3‐HPA in the CCA solution with a volume ratio of 1:1 could significantly enhance ion signals for phosphopeptides in both positive‐ion and negative‐ion detection modes compared with the use of pure CCA or DHB, the most common phosphopeptide matrices. Higher signal intensities of phosphopeptides could be obtained with lower laser power using the binary matrix. Neutral loss of the phosphate group (?80 Da) and phosphoric acid (?98 Da) from the phosphorylated‐residue‐containing peptide ions with the binary matrix was decreased compared with CCA alone. In addition, since the crystal shape prepared with the binary matrix was more homogeneous than that prepared with DHB, searching for ‘sweet’ spots can be avoided. The sensitivity to detect singly or doubly phosphorylated peptides in peptide mixtures was higher than that obtained with pure CCA and as good as that obtained using DHB. We also used the binary matrix to detect the in‐solution tryptic digest of the crude casein extracted from commercially available low fat milk sample, and found six phosphopeptides to match the digestion products of casein, based on mass‐to‐charge values and LIFT TOF‐TOF spectra. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

11.
An organic salt, N-(1-naphthyl) ethylenediamine dinitrate (NEDN), with rationally designed properties of a strong UV absorbing chromophore, hydrogen binding and nitrate anion donors, has been employed as a matrix to analyze small molecules (m/z?相似文献   

12.
So far, there have been only a few matrices reported for detection of polysaccharides with molecular weight higher than 3000 Daltons by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). In this work, we found that 2',4',6'-trihydroxyacetophenone (THAP) is a good matrix for MALDI time-of-flight MS analysis of polysaccharides with broad mass range. Large polysaccharides, dextrans, glycoproteins and polysialic acids have been successfully detected by MALDI-MS with THAP as matrix.  相似文献   

13.
微流控芯片与质谱联用为细胞研究提供了一个很好的研究平台.质谱的高灵敏度和对化合物独特的鉴别能力可以从复杂的化学信息背景中筛选识别出微量目标物,是细胞分析理想的检测手段.本文重点综述了近年来基于微流控芯片-质谱联用技术的细胞研究进展,从芯片-电喷雾质谱(ESI-MS)接口技术、集成化的样品前处理技术、细胞的药物代谢和细胞相互作用研究及基质辅助激光解吸电离质谱(MALDI-MS)的细胞分析应用等方面总结了最新的方法和技术发展.并展望了芯片-质谱联用新技术应用于细胞分析的可能性.  相似文献   

14.
An integrated analytical strategy for enrichment, detection and sequencing of phosphorylated peptides by matrix-assisted laser desorption/ionization (MALDI) tandem mass spectrometry (MS/MS) is reported. o-Phosphoric acid was found to enhance phosphopeptide ion signals in MALDI-MS when used as the acid dopant in 2,5-dihydroxybenzoic acid (2,5-DHB) matrix. The effect was largest for multiply phosphorylated peptides, which exhibited an up to ten-fold increase in ion intensity as compared with standard sample preparation methods. The enhanced phosphopeptide response was observed during MALDI-MS analysis of several peptide mixtures derived by proteolytic digestion of phosphoproteins. Furthermore, the mixture of 2,5-DHB and o-phosphoric acid was an excellent eluant for immobilized metal affinity chromatography (IMAC). Singly and multiply phosphorylated peptide species were efficiently recovered from Fe(III)-IMAC columns, reducing sample handling for phosphopeptide mapping by MALDI-MS and subsequent phosphopeptide sequencing by MALDI-MS/MS. The enhanced response of phosphopeptide ions in MALDI facilitates MS/MS of large (>3 kDa) multiply phosphorylated peptide species and reduces the amount of analyte needed for complete characterization of phosphoproteins.  相似文献   

15.
Qualitative and quantitative analysis of post‐translational protein modifications by mass spectrometry is often hampered by changes in the ionization/detection efficiencies caused by amino acid modifications. This paper reports a comprehensive study of the influence of phosphorylation and methylation on the responsiveness of peptides to matrix‐assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI) mass spectrometry. Using well‐characterized synthetic peptide mixtures consisting of modified peptides and their unmodified analogs, relative ionization/detection efficiencies of phosphorylated, monomethylated, and dimethylated peptides were determined. Our results clearly confirm that the ion yields are generally lower and the signal intensities are reduced with phosphopeptides than with their nonphosphorylated analogs and that this has to be taken into account in MALDI and ESI mass spectrometry. However, the average reduction of ion yield caused by phosphorylation is more pronounced with MALDI than with ESI. The unpredictable impact of phosphorylation does not depend on the hydrophobicity and net charge of the peptide, indicating that reliable quantification of phosphorylation by mass spectrometry requires the use of internal standards. In contrast to phosphorylation, mono‐ and dimethylated peptides frequently exhibit increased signal intensities in MALDI mass spectrometry (MALDI‐MS). Despite minor matrix‐dependent variability, MALDI methods are well suited for the sensitive detection of dimethylated arginine and lysine peptides. Mono‐ and dimethylation of the arginine guanidino group did not significantly influence the ionization efficiency of peptides in ESI‐MS. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

16.
This article describes a simple procedure for the detection of phosphorylated peptides by comparable positive and negative ion mode matrix-assisted laser desorption/ionization mass spectrometry measurements. Based on studies with phosphorylated peptides (EAIXAAPFAK, X = pS, pT, pY) and their corresponding non-phosphorylated analogs, it was found that phosphopeptides, which are characterized by a low ionization efficiency in the positive ion mode, exhibit drastically increased signal intensities in the negative ion mode compared to their non-phosphorylated analogs. The effect was successfully used to identify phosphorylated sequences of the commonly used phosphoprotein standards, protein kinase A and beta-casein, by peptide mass fingerprint analyses of the corresponding Lys C and trypsin digests using both (positive and negative) ion modes. The comparison of positive and negative ion spectra of a given protein digest (relative intensity([M - H]-)/relative intensity([M + H]+)) can be used to identify any phosphopeptides present which may then be separated and analyzed further.  相似文献   

17.
Quantitative detection of metabolites is a highly desirable feature in metabolome analyses. Recently, the successful detection of multiple metabolites using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) in the negative ion mode employing 9-aminoacridine as the organic matrix was reported (Edwards JL, Kennedy RT. Anal. Chem. 2005; 77: 2201-2209). However, there is little information available on quantitative detection of multiple metabolites using MALDI-MS and in particular the influence changes in metabolite levels have on such detections. We investigated this aspect by spiking a synthetic metabolite cocktail (consisting of 39 metabolites including amino acids, organic acids and phospho-metabolites) with five representative metabolites at increasing concentrations, one metabolite at a time, and assessed the signals from replicate determinations. It was possible to detect quantitative changes in the spiked metabolites. Although analyte suppression was observed, it was possible to observe scenarios where the spiked metabolite had little or no influence on the quantitative detection of some metabolites. It appears that the mass spectral response of the metabolite is suppressed only when the spiked chemical species are relatively similar in chemical terms. This suggests that quantitation is possible in scenarios where changes in a specific metabolite or a class of metabolites are monitored following appropriate analyte separation strategies, and that careful interpretations must be made when using the technique for quantitative analysis in unbiased metabolomic approaches.  相似文献   

18.
In this study, a new type of localized surface plasmon resonance (LSPR) sensing substrate for phosphopeptides was explored. It has been known that LSPR response for target species is larger in the near-infrared region (NIR) than in the visible region of the electromagnetic spectrum. Several types of noble metal nanoparticles (NPs) with NIR absorption capacities have been previously demonstrated as effective LSPR-sensing nanoprobes. Herein, we demonstrate a straightforward approach with improved sensitivity by simply using layer-by-layer (LBL) spherical Au NPs self-assembled on glass slides as the LSPR-sensing substrates that are responsive in the NIR region of the electromagnetic spectrum. The modified glass slide acquired an LSPR absorption band in the NIR, which resulted from the dipole–dipole interactions between Au NPs. To enable the chip to sense phosphopeptides, the surface of the glass chip was spin-coated with thin titania film (TiO2-Glass@Au NPs). Absorption spectrophotometry was employed as a detection tool. Tryptic digest of α-casein was used as a model sample. The feasibility of using the new LSPR approach for detecting a potential risk factor leading to cancers (i.e., phosphorylated fibrinopeptide A) directly from human serum samples was demonstrated. Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) was used to confirm the results.  相似文献   

19.
We report substantial in‐situ enrichment of phosphopeptides in peptide mixtures using titanium and zirconium dioxide‐coated matrix assisted laser desorption‐ionization (MALDI) plates prepared by recently reported ambient ion landing deposition technique. The technique was able to modify four common materials currently used for MALDI targets (stainless steel, aluminum, indium‐tin oxide glass and polymeric anchor chip). The structure of the deposited dioxide was investigated by electron microscopy, and different surfaces were compared and discussed in this study. Two standard proteins were used to test the enrichment capabilities of modified MALDI plates: casein and in‐vitro phosphorylated trehalase. The enrichment of casein tryptic digest resulted in identification of 20 phosphopeptides (including miscleavages). Trehalase was used as a suitable model of larger protein that provided more complex peptide mixture after the trypsin digestion. All four possible phosphorylation sites in trehalase were identified and up to seven phosphopetides were found (including methionine oxidations and miscleavages). Two different mass spectrometers, MALDI‐Fourier transform ion cyclotron resonance (FTICR) and MALDI‐time of flight, were used to detect the phosphopeptides from modified MALDI plates after the enrichment procedure. It was observed that the desorption‐ionization phenomena on the modified surfaces are not critically influenced by the parameters of the different MALDI ion sources (e.g. different pressure, different extraction voltages), and thus the presence of dioxide layer on the standard MALDI plate does not significantly interfere with the main MALDI processes. The detection of phosphopeptides after the enrichment could be done by both instruments. Desorption electrospray ionization coupled to the FTICR was also tested, but, unlike MALDI, it did not provide satisfactory results. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

20.
An API 3000 triple-quadrupole instrument and a QSTAR Pulsar quadrupole time-of-flight (TOF) mass spectrometer were compared for the determination of phosphopeptides by precursor ion scanning in both the positive and negative nanoelectrospray ionization modes. The limits of detection for synthetic phosphopeptides were similar (500 amol microl(-1)) for both types of instruments when monitoring precursors of -79 Da (PO(3)(-)). However, the quadrupole TOF system was approximately fivefold more sensitive (1 fmol microl(-1)) than the triple-quadrupole instrument (5 fmol microl(-1)) when monitoring precursors of 216 Da (immonium ion of phosphotyrosine). The recently introduced Q(2)-pulsing function, which enhances the transmission of fragment ions of a selected m/z window from the collision cell into the TOF part, improved the sensitivity of precursor ion scans on a quadrupole TOF instrument. The selectivity of precursor ion scans is much better on quadrupole TOF systems than on triple quadrupoles because the high resolving power of the reflectron-TOF mass analyzer permits high-accuracy fragment ion selection at no expense of sensitivity. This minimizes interferences from other peptide fragment ions (a-, b-, and y- type) of the same nominal mass but with sufficient differences in their exact masses. As a result, the characteristic immonium ion of phosphotyrosine at m/z 216.043 can be utilized for the selective detection of tyrosine phosphorylated peptides. Our data suggest that, in addition to their superior performance for peptide sequencing, quadrupole TOF instruments also offer a very viable alternative to triple quadrupoles for precursor ion scanning, thus combining high sensitivity and selectivity for both MS and MS/MS experiments in one instrument.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号