首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A novel method based on ultrasonic solvent extraction and stir bar sorptive extraction for the analysis of phenolic organic pollutants including chlorophenols, bisphenol-A, 4-tert-octylphenol and 4-nonylphenol in soil samples was developed. The different parameters that affect both the extraction of analytes from the soil samples, such as solvent selection, extraction time, and the partitioning from the solvent/water mix to poly(dimethylsiloxane) (PDMS) were studied. The final selected conditions consisted of the extraction of 1 g of soil with 15 mL methanol by sonication for 30 min. The methanol extract was mixed with 85 mL of Milli-Q water and extracted by means of stir bar sorptive extraction with in situ derivatisation. The stir bars were analyzed by thermal desorption–gas chromatography–mass spectrometry (TD–GC–MS). The effects of the matrix on the recovery of the various pollutants under the developed method were studied using two soils with very different physicochemical properties. Method sensitivity, linearity, repeatability, and reproducibility were also studied. Validation and accuracy of the method were conducted by analyzing two commercial certified reference materials and by comparing the analysis of real samples with the proposed method and a classical method using pressurized solvent extraction (PSE)–GC–MS. The main advantage of this method is a substantial solvent reduction. For the extraction of only 1 g of solid sample allowing limits of detection ranging from 0.2 to 1.7 μg kg−1 dw. Repeatability and reproducibility variation were lower than 20% for all investigated compounds. Results of the certified reference materials and the real samples verify the high accuracy of this method.  相似文献   

2.
In this work, a headspace-solid-phase micro-extraction (HS-SPME) combined with gas chromatography–mass spectrometry (GC–MS) method for multielemental speciation of organometallic compounds of mercury, lead and tin in water samples was upgraded by the introduction of tandem mass spectrometry (MS/MS) as detection technique. The analytical method is based on the ethylation with NaBEt4 and simultaneous headspace-solid-phase micro-extraction of the derivative compounds followed by GC–MS/MS analysis. The main experimental parameters influencing the extraction efficiency such as derivatisation time, extraction time and extraction temperature were optimized. The overall optimum extraction conditions were the following: a 50 μm/30 μm divinyl-benzene/carboxen/polydimethylsiloxane (DVB/CAR/PDMS) SPME fibre, 150 min derivatisation time, 15 min extraction time, sample agitation at 250 rpm and 40 °C extraction temperature. The analytical characteristics of the HS-SPME method combined with GC–MS and GC–MS/MS were evaluated. The combination of both techniques HS-SPME and GC–MS/MS allowed to attain lower limits of detection (4–33 ng l−1) than those obtained by HS-SPME–GC–MS (17–45 ng l−1). The proposed method presented good linear regression coefficients (r2 > 0.9970) and repeatability (4.8–21.0%) for all the compounds under study. The accuracy of the method measured as the average percentage recovery of the compounds in spiked river water and seawater samples was higher than 80% for all the compounds studied, except for monobutyltin in the river water sample. A study of the uncertainty associated with the analytical results was also carried out.  相似文献   

3.
A method using high performance liquid chromatography–electrospray tandem mass spectrometry (LC–ESI-MS/MS) in positive ion mode was developed for the simultaneous analysis of 30 phenolic compounds, including four estrogens, bisphenol A (BPA), 10 hydroxylated polybrominated dephenyl ethers (OH-PBDEs) and 15 bromophenols (BRPs), in blood plasma. In the present method, derivatization with dansyl chloride was employed, and all the derivertized target compounds were well resolved on a 100 mm Xbridge C18 column with acetonitrile and 0.1% formic acid as the mobile phases. Purification procedures, such as liquid–liquid extraction and silica-gel chromatography, were applied to reduce matrix effects in the sample extract and remove excess derivatizing reagents, thus permitting selective and sensitive detection of the target phenolic compounds. The limit of quantification for all analytes, with a signal-to-noise ratio of ∼10, was 2–30 pg/g (plasma weight) except for 6-OH-BDE-137 (30 pg/g) and 3-BRP (60 pg/g). The method was validated for recoveries (68–100%), accuracy (84–110%) and precision (3.7–11%) using charcoal-stripped bovine blood plasma spiked with all target compounds (500 and 5000 pg/mL). Finally, the method was applied to analyze six blood plasma samples from frogs and cormorants, where two natural estrogens, one BPA, one OH-PBDE and four BRPs were detected. The greatest total concentrations of estrogens coincided with the least total concentrations of other phenolic compounds for both species. The proposed method based on derivatization followed by LC–MS/MS provides a novel method to simultaneously monitor multiple groups of phenolic compounds in blood plasma.  相似文献   

4.
An in-vial liquid–liquid microextraction method was developed for the selective extraction of the phenolic acids (caffeic, gallic, cinnamic, ferulic, chlorogenic, syringic, vanillic, benzoic, p-hydroxybenzoic, 2,4-dihydroxybenzoic, o-coumaric, m-coumaric and p-coumaric) in vegetable oil samples. The optimised extraction conditions for 20 g sample were: volume of diluent (n-hexane), 2 mL; extractant, methanol: 5 mM sodium hydroxide (60:40; v/v); volume of extractant, 300 μL (twice); vortex, 1 min; centrifugation, 5 min. Recoveries for the studied phenolic acids were 80.1–119.5%. The simultaneous determination of the phenolic acid extracts was investigated by capillary electrophoresis (CE). Separations were carried out on a bare fused-silica capillary (50 μm i.d. × 40 cm length) involving 25 mM sodium tetraborate (pH 9.15) and 5% methanol as CE background electrolyte in the normal polarity mode, voltage of 30 kV, temperature of 25 °C, injection time of 4 s (50 mbar) and electropherograms were recorded at 200 nm. The phenolic acids were successfully separated in less than 10 min. The validated in-vial LLME-CE method was applied to the determination of phenolic acids in vegetable oil samples (extra virgin olive oil, virgin olive oil, pure olive oil, walnut oil and grapeseed oil). The developed method shows significant advantages over the current methods as lengthy evaporation step is not required.  相似文献   

5.
A novel microextraction technique termed solid phase membrane tip extraction (SPMTE) was developed. Selected triazine herbicides were employed as model compounds to evaluate the extraction performance and multiwall carbon nanotubes (MWCNTs) were used as the adsorbent enclosed in SPMTE device. The SPMTE procedure was performed in semi-automated dynamic mode and several important extraction parameters were comprehensively optimized. Under the optimum extraction conditions, the method showed good linearity in the range of 1–100 μg/L, acceptable reproducibility (RSD 6–8%, n = 5), low limits of detection (0.2–0.5 μg/L), and satisfactory relative recoveries (95–101%). The SPMTE device could be regenerated and reused up to 15 analyses with no analyte carry-over effects observed. Comparison was made with commercially available solid phase extraction-molecular imprinted polymer cartridge (SPE-MIP) for triazine herbicides as the reference method. The new developed method showed comparable or even better results against reference method and is a simple, feasible, and cost effective microextraction technique.  相似文献   

6.
A method for the determination of fatty acids in serum based on GC–MS (micro-SIS detection mode) has been developed and the separation and cis/trans isomers have been identified. A prior two-step extraction/derivatization procedure accelerated by ultrasound allows individual determination of esterified (EFAs) and non-esterified fatty acids (NEFAs), and shortening of the derivatization steps to 5 min for EFAs and 15 min for NEFAs. The total analysis time for 39 fatty acids was 61 min. The minimum LOD and LOQ values were 0.002 and 0.006 μg/ml, respectively. The proposed method was validated for EFAs and NEFAs using two different methods and the results show no statistical differences between the proposed method and those used as reference. The proposed derivatization–extraction methodology is suitable for fatty-acid analysis of human serum, and can be applied to nutritional and epidemiological studies.  相似文献   

7.
The volatile components of Iranian saffron were extracted using ultrasonic solvent extraction (USE) technique and then were separated and detected by gas chromatography–mass spectrometry (GC–MS). Variables affecting the extraction procedure were screened by using a 25−1 fractional factorial design and among them; sample amount, solvent volume, solvent ratio and extraction time were optimized by applying a rotatable central composite design (CCD). The optimum values of factors were: 2.38 g sample, 29.04 mL solvent, 69.23% MeOH solvent ratio and 71.8 min for the extraction time. Forty constituents were identified for Iranian saffron by GC–MS representing 90% of the total peak area. The major components were 2,6,6-trimethyl-1,3-cyclohexadiene-1-carboxaldehyde, namely safranal (26.29%), bicyclo[3,2,0]hept-2-ene-,4-ethoxy-,endo (5.69%), linoleic acid (4.77%), 4-hydroxy-2,6,6-trimethyl-1-cyclohexene-1-carboxaldehyde, namely HTCC (4.44%), and nonadecanol (3.32%). Some new compounds were identified for the first time in saffron. In addition, the results of this study were compared with those of Greek saffron.  相似文献   

8.
A novel solid phase microextraction (SPME) fiber was fabricated by electrospinning method in which a polymeric solution was converted to nanofibers using high voltages. A thin stainless steel wire was coated by the network of polymeric nanofibers. The polymeric nanofiber coating on the wire was mechanically stable due to the fine and continuous nanofibers formation around the wire with a three dimensional structure. Polyamide (nylon 6), due to its suitable characteristics was used to prepare the unbreakable SPME nanofiber. The scanning electron microscopy (SEM) images of this new coating showed a diameter range of 100–200 nm for polyamide nanofibers with a homogeneous and porous surface structure. The extraction efficiency of new coating was investigated for headspace solid-phase microextraction (HS-SPME) of some environmentally important chlorophenols from aqueous samples followed by gas chromatography–mass spectrometry (GC–MS) analysis. Effect of different parameters influencing the extraction efficiency including extraction temperature, extraction time, ionic strength and polyamide amount were investigated and optimized. In order to improve the chromatographic behavior of phenolic compounds, all the analytes were derivatized prior to the extraction process using basic acetic anhydride. The detection limits of the method under optimized conditions were in the range of 2–10 ng L−1. The relative standard deviations (RSD) (n = 3) at the concentration level of 1.7–6.7 ng mL−1 were obtained between 1 and 7.4%. The calibration curves of chlorophenols showed linearity in the range of 27–1330 ng L−1 for phenol and monochlorophenols and 7–1000 ng L−1 for dichloro and trichlorophenols. Also, the proposed method was successfully applied to the extraction of phenol and chlorophenols from real water samples and relative recoveries were between 84 and 98% for all the selected analytes except for 2,4,6 tricholophenol which was between 72 and 74%.  相似文献   

9.
The simultaneous ultrasonic and microwave assisted extraction (UMAE) technique was first employed to obtain phenolics. The effects of UMAE variables including extraction time, microwave power, and solvent to solid radio on the yield of phenolics were investigated. The optimized conditions were as follows: solvent to solid ratio was 20:1 (ml/g), extraction time was 30 s, microwave power was 500 W and two times of extraction. Moreover, the phenolic yield of UMAE was higher than that by maceration, indicating a significant reduction of extraction time and an improvement of efficiency. The phenomenon is related to the strong disruption of leaf tissue structure by microwave induced expansion and ultrasonic shaking, which had been observed with the scanning electron microscopy. The phenolic compositions of the extract was then identified by ultra performance liquid chromatography tandem mass spectrometry (UPLC–MS/MS), 10 compounds had been characterized, providing a more complete identification of phenolic compounds in burdock leaves than previously reported. The occurrence of benzoic acid and p-coumaric acid is reported for the first time. This study suggests that UMAE is a good alternative for the extraction of phenolics, with a great potential for industrial application. Also, UMAE provides a new sample preparation technique for characterization of the phenolic compounds from plants.  相似文献   

10.
In this study, diverse types of Fe3O4 nanocomposites modified by polyaniline, polypyrrole, and aniline–pyrrole copolymer were synthesized through chemical oxidative polymerization process for dispersive-μ-solid phase extraction (D-μ-SPE) in the presence of various dopants. The results showed that the nanocomposite modified by polyaniline with p-toluene sulfonic acid as a dopant demonstrated higher extraction efficiency for lorazepam (LRZ) and nitrazepam (NRZ). Also the synthesized magnetic sorbents were characterized. The nanocomposite sorbent in combination with high performance liquid chromatography–UV detection was applied for the extraction, preconcentration and determination of lorazepam and nitrazepam in urine and plasma samples. Different parameters influencing the extraction efficiency including: sample pH, amount of sorbent, sorption time, elution solvent and its volume, salt content, and elution time were optimized. The obtained optimal conditions were: sample pH, 6; amount of sorbent, 5 mg; sorption time, 5.0 min; elution solvent and its volume, 0.5 mM cethyltrimethyl ammonium bromide in acetonitrile, 150 μL; elution time, 2.0 min and without addition of NaCl. The calibration curves were linear in the concentration range of 1–2000 μg L−1. The limits of detection (LODs) were achieved in the range of 0.5–1.8 μg L−1 for NRZ and 0.2–2.0 μg L−1 for LRZ, respectively. The percent of extraction recoveries and relative standard deviations (n = 5) were in the range of 84.0–99.0, 6.1–7.8 for NRZ and 90.0–99.0, 4.1–7.0 for LRZ, respectively. Ultimately, the applicability of the method was successfully confirmed by the extraction and determination of NRZ and LRZ in human urine and plasma samples.  相似文献   

11.
An automated, simple and sensitive method based on selective pressurized liquid extraction (SPLE) was developed for the analysis of polycyclic aromatic hydrocarbons in sewage sludge samples. The new sample preparation procedure consists of on-line clean-up by inclusion of sorbents in the extraction cell, and combines elevated temperatures and pressures with liquid solvents to achieve fast and efficient removal of target analytes from complex sewage sludge matrices. The effects of various operational parameters (e.g. sample pretreatment, extraction solvent, temperature, pressure, static time, etc.) on the performance of SPLE procedure were carefully investigated, obtaining the best results when SPLE conditions were fixed at 140 °C, 1500 psi, static time of 5 min and n-hexane as extraction solvent. A new programmed temperature vaporization–gas chromatography–tandem mass spectrometry method based on large volume injection (PTV–LVI–GC–MS/MS) was also developed and analytical determinations were performed by high performance liquid chromatography coupled with fluorescence detection and GC–MS/MS. The extraction yields for the different compounds obtained by SPLE ranged from 84.8% to 106.6%. Quantification limits obtained for all of these studied compounds (between 0.0001 and 0.005 μg g−1, dry mass) were well below the regulatory limits for all compounds considered. To test the accuracy of the SPLE technique, the optimized methodology was applied to the analysis of a certified reference material (sewage sludge (BCR088)) and a reference material (sewage sludge (RTC-CNS312-04)), with excellent results.  相似文献   

12.
This work describes optimization of headspace single drop micro-extraction for extraction of five organophosphorus pesticides; thionazin, sulfotep, dimethoate, disulfoton and parathion in soil. Ultrasound has also been used successfully to improve and accelerate the extraction of the analytes from the sample. The optimized extraction performance was obtained when the experimental parameters were set as follows; 3.0 μL of octanol as extraction solvent, high ionic strength (20% sodium chloride), 1:1 (w/v) sample dilution with water, extraction temperature at 60 °C for 30 min; applying ultrasound and without any pH adjustment. The optimized method was linear over the calibration range (5–200 and 10–300 for different analytes) with limits of detection of 0.1–2.0 ng g−1. The enrichment factor for OPPs was 1.4–12.7 and the method was also reproducible with the relative standard deviations (RSD%) of 2.1–6.9%.  相似文献   

13.
This paper describes a method for the determination of a group of personal care products including four UV filters, four preservatives and two antimicrobials in sewage sludge. The method combines pressurized liquid extraction and ultra high performance liquid chromatography–tandem mass spectrometry. Most of the parameters that affect the extraction step such as temperature, pressure, static extraction time, number of cycles, purge time and flush volume were optimized using a fractional experimental design. In the chromatographic step, the compounds were detected by using tandem mass spectrometry with a triple quadrupole analyzer with electrospray ionization in positive and negative modes. The use of small diameter particles (1.8 μm) in the chromatographic column allowed the compounds to be eluted in 9 min. The entire process took a total of 39 min. All recoveries were higher than 72% except for 2,4-dihydroxybenzophenone (a UV filter), whose recovery was 30%. The repeatability and reproducibility between days expressed as RSD (%) (n = 3) were less than 8% and 13%, respectively. The LODs and LOQs were lower than 8 μg/kg and 12.5 μg/kg of dry weight (d.w.), respectively. When the method was applied to determine the compounds in sewage sludge from a domestic sewage treatment plant, triclosan (an antimicrobial) and octocrylene (a UV filter) showed the highest levels, 1490 μg/kg (d.w.) and 1842 μg/kg (d.w.), respectively. This paper describes for the first time the determination of parabens and two UV filters (octyldimethyl-p-aminobenzoic acid and benzophenone-3) in sewage sludge.  相似文献   

14.
A solvent free microwave hydrodiffusion and gravity extraction (MHG) of flavonol content from onion (Allium cepa L.) was studied. Effectiveness of this innovative method in extraction of onion total phenolic content, total quercetin (TQ), quercetin aglycon (QA), quercetin-3,4′-diglucoside (QDG), quercetin-4′-monoglucoside (Q4G), quercetin-3-monoglucoside (Q3G), kaempferol (KMF) and myricetin (MRT) have been evaluated and compared with conventional solvent extraction. Microwave extraction offers important advantages like shorter extraction time (23 min), cleaner feature (no solvent or water used) and extraction of valuable onion crude juice retaining fresh organoleptic properties with higher phenolic content (58.29 mg GAE/g DW) at optimized power (500 W). Microwave extraction resulted significant yield (81.5%) with 41.9% of flavonol contents, with better retain of remaining flavonoids (55.9%) in residues of onions. QDG (239.7 mg/100 g DW) and Q4G (82.55 mg/100 g DW) have been reported the main flavonol in this study. Minor quantities of QA (traces), Q3G (4.22 mg/100 g DW) and KMF (3.99 mg/100 g DW) were also detected in microwave onion extracts.  相似文献   

15.
1-Vinyl-3-octadecylimidazolium bromide ionic liquid [C18VIm]Br was prepared and used for the modification of mercaptopropyl-functionalized silica (Si-MPS) through surface radical chain-transfer addition. The synthesized octadecylimidazolium-modified silica (SiImC18) was characterized by thermogravimetric analysis (TGA), infrared spectroscopy (IR), 13C NMR and 29Si NMR spectroscopy and used as an extraction phase for the automated 96-blade solid phase microextraction (SPME) system with thin-film geometry using polyacrylonitrile (PAN) glue. The new proposed extraction phase was applied for extraction of aminoacids from grape pulp, and LC–MS–MS method was developed for separation of model compounds. Extraction efficiency, reusability, linearity, limit of detection, limit of quantitation and matrix effect were evaluated. The whole process of sample preparation for the proposed method requires 270 min for 96 samples simultaneously (60 min preconditioning, 90 min extraction, 60 min desorption and 60 min for carryover step) using 96-blade SPME system.  相似文献   

16.
Based on the merits of well-established capillary gas chromatography (GC), metallomesogenic polymer was used as the stationary phase and flame ionization detector (FID) was used as the detector, the analysis of phenolic compounds explored the possibility of application in complex matrices. We proposed the method combined supercritical-fluid extraction (SFE) of phenolic compounds, which had been enriched on the solid supports of XAD-4 resins, and then with their determinations by capillary GC-FID. The SFE parameters suitable for 15 phenols simultaneously adsorbed onto XAD-4 resins in aqueous solution were assessed by a 45 factorial design method. The best results were 5 min static time, 10 min dynamic time, 0.25 ml methanol spiked, 80 °C oven temperature and 410 atm CO2 pressure. Also, other parametric conditions for specific phenols were revealed and analyzed. In the comparison with Soxhlet extraction with regard to the recoveries and reproducibility, the developed SFE was quite superior and helped to reduce the detection limit of aqueous samples to 10−2-fold. Eventually, the polluted soils near a pharmaceutical factory were primarily tested and given the probable distribution.  相似文献   

17.
A new approach using single-drop microextraction (SDME) and gas chromatography–mass spectrometry for the determination of six haloacetic acids (HAAs) in water samples was presented. n-Octanol was used as extractant and derivatization reagent. HAAs were derivatized both simultaneously during the extraction in the solvent microdrop, and after extraction, inside a glass microvial (1.1 mm I.D.). Trifluoroacetic anhydride (TFAA) was used as the reaction catalyst. The influence of catalyst amount, derivatization time and temperature on the yield of the in-microvial derivatization was investigated. Derivatization reaction was performed using 1.2 μL of TFAA at 100 °C for 20 min. Extraction was performed using 1.8 μL of n-octanol containing TFAA (10%, v/v). Experimental parameters, such as, exposure time, sample pH and extraction temperature were controlled and optimized. Analytical parameters such as linearity, precision and limit of detection were also evaluated. The proposed method was proved to be a suitable analytical procedure for HAAs in water with limits of detection 0.1–1.2 μg/L. The relative recoveries range from 82.5 to 97.6% for all the target analytes. Precision values were from 5.1 to 8.5% (as intra-day relative standard deviation, RSD) and 8.8–12.3% (as inter-day RSD).  相似文献   

18.
A microwave-assisted extraction (MAE) and ultra high performance liquid chromatography coupled with diode array detection and time-of-flight mass spectrometry (UHPLC-DAD-TOF-MS) method was developed for simultaneous determination of 14 phenolic compounds in the root of Pueraria lobata (Wild.) Ohwi and Pueraria thomsonii Benth. Operational conditions of MAE were optimized by central composite design (CCD). The optimized result was 65% ethanol as extraction solvent, 17 mL of extraction volume, 100 °C of extraction temperature and 2 min of hold time. A Zorbax SB C18 (50 mm × 4.6 mm I.D., 1.8 μm) and gradient elution were used during the analysis. The chromatographic peaks of 14 investigated compounds in samples were successfully identified by comparing their retention time, UV spectra and TOF mass data with the reference substances. All calibration curves showed good linearity (r > 0.9997) within the test ranges. The intra-day and inter-day variations were less than 1.77% and 2.88%, respectively. The developed method was successfully applied to determine the investigated compounds in 10 samples of Radix Puerariae Lobatae and Radix Puerariae Thomsonii, respectively. The result indicated that MAE and UHPLC-DAD-TOF-MS system might provide a rapid method for the quality control of Radix Puerariae.  相似文献   

19.
A novel sample preparation method “Dispersive liquid–liquid–liquid microextraction” (DLLLME) was developed in this study. DLLLME was combined with liquid chromatography system to determine chlorophenoxy acid herbicide in aqueous samples. DLLLME is a rapid and environmentally friendly sample pretreatment method. In this study, 25 μL of 1,1,2,2-tetrachloroethane was added to the sample solution and the targeted analytes were extracted from the donor phase by manually shaking for 90 s. The organic phase was separated from the donor phase by centrifugation and was transferred into an insert. Acceptor phase was added to this insert. The analytes were then back-extracted into the acceptor phase by mixing the organic and acceptor phases by pumping those two solutions with a syringe plunger. After centrifugation, the organic phase was settled and removed with a microsyringe. The acceptor phase was injected into the UPLC system by auto sampler. Fine droplets were formed by shaking and pumping with the syringe plunger in DLLLME. The large interfacial area provided good extraction efficiency and shortened the extraction time needed. Conventional LLLME requires an extraction time of 40–60 min; an extraction time of approximately 2 min is sufficient with DLLLME. The DLLLME technique shows good linearity (r2 ≥ 0.999), good repeatability (RSD: 4.0–12.2% for tap water; 5.7–8.5% for river water) and high sensitivity (LODs: 0.10–0.60 μg/L for tap water; 0.11–0.95 μg/L for river water).  相似文献   

20.
A sensitive method based on programmable temperature vaporization large volume injection coupled to gas chromatogram and high-resolution mass spectrometry (PTV-GC–HRMS) has been developed for the determination of ultra trace levels of dioxin-like polychlorinated biphenyls (DL PCBs) in small amounts of human blood. Blood samples (1 mL) were first extracted by column extraction and then purified with column chromatorgraphies. Final extracts (20 μL) were introduced to the PTV injector under the solvent vent mode and detected by GC–HRMS (SIM mode). PTV parameters were observed by changing one factor at a time (practical conditions: vent flow: 50 mL min−1, vent pressure: 0 kPa and vent time: 0.1 min), recoveries of most PCB congeners ranged from 55.1% to 108%, and method detection limits were in the range of 0.11–1.63 pg g−1.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号