首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The extraction and determination of chlorinated biphenyls (CBs) in soils and solid wastes is an ongoing subject of study. This is an overview article that compares the microwave-assisted extraction (MAE) and accelerated solvent extraction (ASE) techniques. The extraction of CBs by ASE has been optimised taking into account the variation of pressure, temperature and extraction time by means of experimental design and the Simplex approach. The recoveries obtained under the optimum conditions are compared and discussed with those obtained from MAE and Soxhlet extractions.  相似文献   

2.
Solid phase extraction (SPE) with appropriate solid sorbents has been commonly used in the routine extraction of organic pollutants in water. The elution of analytes from the solid sorbents normally takes place by organic solvents under an applied vacuum. In this study, a microwave-assisted solvent elution technique was developed for the elution of analytes from C18 membrane disks during microwave irradiation from a microwave extraction system (MES). Several parameters, namely, elution solvent, elution temperature, duration of elution and the volume of solvent which may affect the elution efficiency of microwave-assisted solvent elution (MASE) technique towards organochlorine pesticides (OCPs), polychlorinated biphenyls (PCBs), polycyclic aromatic hydrocarbons (PAHs), phthalate esters (PAEs), organophosphorus pesticides (OPs), fungicides, herbicides and insecticides from the membrane disk were investigated. Good recoveries above 75% were obtained for most of the organic pollutants using the optimum SPE-MASE technique. The effect of sodium chloride and humic acid on the recoveries on the target analytes were also investigated.  相似文献   

3.
Slurry sampling is compared to microwave-assisted acid digestion for cobalt determination in soil/sediment samples by electrothermal atomic absorption spectrometry (ETAAS). Furnace temperature programs and appropriate amounts of three chemical modifiers were optimised in order to get the highest signals and good separations between the atomic and background signals. Using nitric acid (0.5% (v/v)) as liquid medium, no chemical modifier was needed. The detection limit, based on integrated absorbance, was 0.04 μg g−1 for digests and slurries. Within-batch precision and analytical recoveries were satisfactory for both procedures. Accuracy was tested by analysing a reference soil and a sediment from IRMM. The methods were further compared employing a set of roadside soils and estuarine sediments. As no significant differences (95% confidence) were found, practical analytical properties were suggested in order to select one of them.  相似文献   

4.
An efficient microwave-assisted extraction (MAE) method has been developed and evaluated for the quantification of eight major polybrominated diphenylethers (PBDEs) in sewage sludge. The PBDEs were extracted from wet and dry sludge in a microwave extraction unit using a hexane/acetone mixture for 35 min at a controlled temperature of 130 °C. The extract was concentrated, cleaned up on a silica gel column, and analyzed by gas chromatography/mass spectrometry (GC/MS) in the negative chemical ionization (NCI) mode. The MAE procedure exhibited higher extraction efficiency, specifically for BDE (brominated diphenylether) 209, than the conventional Soxhlet extraction. The test congeners were clearly separated under specific instrumental operating conditions, at a source temperature of 230 °C and a column length of 20 m. The present analytical method showed recovery efficiencies ranging from 80 to 110% when applied to the PBDE-free sludge spiked with eight PBDE congeners. The efficiency of the MAE method was confirmed using sludge obtained from four sewage treatment plants (STPs). The results indicate that BDE 47, 99, and 209 are the most abundant congeners present in these sewage sludges, which is consistent with previous reports.  相似文献   

5.
In the present work, pulsed electromembrane extraction (PEME) was performed for the first time, as a new concept of electrically enhanced microextraction method, for extraction and quantification of histidine, phenylalanine and tryptophan in different matrices. PEME offers an alternative to conventional electromembrane extraction (EME), which faces problems such as serious instabilities in the analysis of real samples with high concentration levels of ions. In these samples, increasing of the ion transportation across the liquid membrane results in Joule heating during the extraction process which may follow by punctuation of the organic membrane, increasing of the current level and bubble formation due to electrolysis reactions. A mixture of 2-nitrophenyl octyl ether (NPOE), di-(2-ethylhexyl) phosphate (DEHP) and tris-(2-ethylhexyl) phosphate (TEHP) was immobilized in the pores of hollow fiber as the organic liquid membrane. Other effective parameters such as extraction time, ion balance and pulse frequency were optimized using the experimental design. Extraction recoveries in the range of 7.1–21.6% and satisfactory repeatability (2.1 < CV% < 4.5) were obtained. Limits of detection were 5, 10 and 30 ng mL−1 for tryptophan, phenylalanine and histidine, respectively. The method offers acceptable linearity with correlation coefficients higher than 0.9979. Furthermore, the figures of merit of PEME are compared with the results from conventional electromembrane extraction (EME), which proves the advantages of the proposed technique. The method was applied to the determination and quantification of amino acids in foods and biological samples. Also, two-way PEME was employed as a novel approach for highly selective extraction of tryptophan as a model analyte to introduce an interesting ability of the proposed technique.  相似文献   

6.
A novel on-line solid-phase microextraction–high-performance liquid chromatography(SPME–HPLC)system was developed for the determination of heterocyclic aromatic amines(HAAs) in food samples. A poly(vinylphenylboronic acid-co-ethylene glycol dimethacrylate) polymer monolith was prepared for on-line efficient extraction and large-volume injection was used to increase the sensitivity of detection.The polymermonolith, based on a ternary porogen, was prepared by in situ polymerization of vinylphenylboronic acid(VPBA) and ethylene glycol dimethacrylate(EGDMA) in a fused-silica capillary column. It showed good permeability, high extraction capacity, and high selectivity. The column-tocolumn reproducibility was satisfactory, and the enrichment factors for HAAs were 3746–7414.Conditions influencing the on-line extraction efficiency, including p H of sample solutions, flow rate of extraction and desorption, and desorption volume, were investigated. The proposed method had low limit of detection(0.10–0.15 ng/L) and good linearity. Trace HAAs in roast beef and lamb samples were determined, and the amounts of 2-amino-3-methylimidazo[4,5-f]quinoline, 2-amino-3,4-dimethylimidazo[4,5-f]quinoline, 2-amino-3,8-dimethylimidazo[4,5-f]quinoxaline, 2-amino-3,4,8-trimethylimidazo[4,5-f]quinoxaline, and 2-amino-3,4,7,8-tetramethyl-3H-imidazo[4,5-f]quinoxaline in these samples were 0.235–2.08 ng/g. The recoveries for the five HAAs ranged from74.3% to 119%, and the relative standard deviation(RSDs) were less than 8.2%. The results showed that the proposed on-line method was highly sensitive for monitoring HAAs in different food samples.  相似文献   

7.
利用HPLC-UV和HPLC-ESI-MSn技术系统地研究了传统中药刺五加中黄酮类化合物在微波辅助常压和高压提取过程中的化学变化, 并考察了提取压力和提取时间对其化学变化规律的影响, 结果表明, 在提取压力超过300 kPa时芦丁开始失去一个芸香糖转化为槲皮素; 随着微波照射时间的延长, 金丝桃苷、芦丁、槲皮苷和槲皮素提取产率先增加, 而后下降. 提取压力越大, 提取速率越快, 分解的速度也越快,达到最高提取产率的时间越短.  相似文献   

8.
Three commonly applied extraction techniques for persistent organic chemicals, Soxhlet extraction (SE), accelerated solvent extraction (ASE) and microwave-assisted extraction (MAE), were applied on soil and fish samples in order to evaluate their performances. For both PCBs and PBDEs, the two more recent developed techniques (ASE and MAE) were in general capable of producing comparable extraction results as the classical SE, and even higher extraction recoveries were obtained for some PCB congeners with large octanol-water partitioning coefficients (Kow). This relatively uniform extraction results from ASE and MAE indicated that elevated temperature and pressure are favorable to the efficient extraction of PCBs from the solid matrices. For PBDEs, difference between the results from MAE and ASE (or SE) suggests that the MAE extraction condition needs to be carefully optimized according to the characteristics of the matrix and analyte to avoid degradation of higher brominated BDE congeners and improve the extraction yields.  相似文献   

9.
A method to determine 21 organochlorine pesticides in vegetation samples using microwave-assisted extraction (MAE) is described and compared with Soxhlet extraction. Samples were extracted with hexane–acetone (1:1, v/v) and the extracts were cleaned using solid-phase extraction with Florisil and alumine as adsorbents. Pesticides were eluted with hexane–ethyl acetate (80:20, v/v) and determined by gas chromatography and electron-capture detection. Recoveries obtained (75.5–132.7% for Soxhlet extraction and 81.5–108.4% for MAE) show that both methods are suitable for the determination of chlorinated pesticides in vegetation samples. The method using microwave energy was applied to grass samples from parks of A Coruña (N.W. Spain) and to vegetation from the contaminated industrial area of Torneiros (Pontevedra, N.W. Spain).  相似文献   

10.
An effective extraction method was devised for the determination of organophosphorus pesticides (OPPs) in olive and avocado oil samples, using atmospheric pressure microwave-assisted liquid–liquid extraction (APMAE) and solid-phase extraction or low-temperature precipitation as clean-up step. A simple glass system equipped with an air-cooled condenser was designed as an extraction vessel. The pesticides were partitioned between acetonitrile and oil solution in hexane. Analytical determinations were carried out by gas chromatography-flame photometric detection and gas chromatography–tandem mass spectrometry, using a triple quadrupole mass analyzer, for confirmation purposes. Several factors influencing the extraction efficiency were investigated and optimized through fractional factorial design and Doehlert design. Under optimal conditions the recovery of pesticides from oil at 0.025 μg g−1 ranged from 71% to 103%, except for fenthion in avocado oil, with RSDs ≤13% (n = 5). The LOQ for the entire method ranged from 0.004 to 0.015 μg g−1. Finally, the proposed method was successfully applied to the extraction and determination of the selected pesticides in 20 commercially packed extra virgin olive oils and four commercially packed avocado oils produced in Chile. Detectable residues of different OPPs were observed in 85% of samples.  相似文献   

11.
In this study, a novel solid-liquid-solid extraction approach, which was termed ‘microwave-assisted micro-solid-phase extraction’ (MAE-μ-SPE), was developed. Target analytes were extracted from the sample into extraction solvent enhanced by microwave field, following adsorption by the adsorbent in the micro-solid-phase extraction device. Without any clean-up steps, the extracts were analysed by high performance liquid chromatography coupled with ultra-violet detector. The MAE-μ-SPE approach was developed for the extraction of four tetracycline antibiotics residues in environmental soil, sludge and atmospheric particulate matters. Variables affecting extraction procedures were systematically investigated. Low detection limits of 0.1–6.3 ng/g and low quantification limits of 0.33–20.7 ng/g were achieved under optimised conditions. The recoveries of antibiotics ranged from 70.6% to 110.5% with relative standard deviation of less than 15.1%. The predominance was showed when compared to conventional MAE and μ-SPE method. According to the results, MAE-μ-SPE was proved to be a simple and effective sample preparation method for the analysis of trace organic contaminants in environmental samples.  相似文献   

12.
Wu X  Hu J  Zhu B  Lu L  Huang X  Pang D 《Journal of chromatography. A》2011,1218(41):7341-7346
A sorbent based on the aptamer for ochratoxin A was immobilized onto magnetic nanospheres (MNS) and used to develop a magnetic solid-phase extraction procedure to clean up food samples in conjunction with high-performance liquid chromatography separation and fluorescence detection. Specific retention of ochratoxin A by the sorbent was demonstrated, and the capacity of the MNS-aptamer sorbent was determined. The efficacy of this new approach was successfully evaluated through comparison with solid-phase extraction on commercial C18 cartridge. Several different food samples fortified in the range of with 2.5-50 μg/kg yielded mean recoveries from 67% to 90%, respectively. Finally, this oligosorbent was applied to the selective extraction of ochratoxin A from unfortified food samples.  相似文献   

13.
The analysis of hydrocarbons in chert rocks provides a worthwhile source of information regarding the geochemical features of a depositional setting. Since the typical analytical procedure requires long Soxhlet extractions and the use of large quantities of sample (30-50 g), in this work we have optimised the focused ultrasound extraction (FUSE) and the microwave-assisted extraction (MAE) to make available a less severe procedure. In both cases a full experimental design including solvent mixture composition (Dichloromethane/Hexane/Acetone) and process variables (sonication time and cycles, and extraction temperature and time) by means of D-optimal designs. In the extracted fractions hydrocarbons (C16-C40) were analysed by gas-chromatography-mass spectrometry. In the case of FUSE the process variables were the most sensitive variables and the optimum conditions were defined at 60:40 DCM/Hex mixture and a sonication time of 30 min and 9 cycles. In the case of MAE all the variables shown a significant effect on the extraction yield and the most adequate conditions (60:30:10 DCM/Hex/Ace mixture and an irradiation time of 15 min at 110 °C) were established from the analysis of the response surface. Both methods were systematically applied with different chert samples collected in Cucho (Trebiño County, Burgos, Spain) and we were able to assure quantitative extractions (>85%) in the first extraction. Additionally, from the distribution patterns of n-alkanes obtained in the different chert samples (nodular chert, laminar chert and massive-brechoid chert) collected in Cucho, we were able to distinguish different origins and diagenetic history.  相似文献   

14.
Microwave-assisted extraction (MAE) of nonylphenols (NP), nonylphenol mono- and diethoxylates (NP1EO and NP2EO, respectively) and phthalate esters was optimised using an experimental design approach. A D-optimal mixture design was used to optimise the pressure inside the extraction vessel (110-207 kPa), the extraction time (5-25 min) and the extraction solvent (methanol, acetone or n-hexane) or the solvent mixture for the microwave-assisted extraction. Percentage of microwave power (80%) and solvent volume (15 ml) were fixed in all the experiments. As a consequence, the optimum extraction of these compounds was carried out at an intermediate pressure (159 kPa) with pure methanol and during 15 min. Moreover, solid phase extraction was also optimised for the clean-up of the extracts and C-18, LiChrolut® and Oasis® cartridges were studied in order to obtain the best recoveries of the compounds of interest. The highest recoveries were obtained with LiChrolut® cartridges after the elution with ethyl acetate. The cleaned extracts were analysed in a gas chromatograph with mass spectrometric detection and in a liquid chromatograph with diode array and fluorescence detection (HPLC-DAD-UV-FLD). The same sediment was also extracted twice in order to check that an exhaustive extraction of the analytes had occurred. Finally, the optimised extraction method was compared with pressurised solvent extraction (PSE), using an estuarine sediment sample.  相似文献   

15.
Cyanuric acid (CYA) is attracting more attention due to its potential toxicity. In the present work, microwave-assisted extraction method in combination with liquid chromatography-tandem mass spectrometry (LC-MS/MS) was proposed for the determination of CYA in pet food samples. Among different solvents, diethylamine-acetonitrile-water mixture (1:5:4, v/v) was found to be the best one as the extractant due to the strong polarity of CYA in the pet food. An internal standard, (13) C(3) -labeled CYA, was used in the extractions. The separation was performed on a MERCK ZIC HILIC column (150 mm × 2.1 mm id, 5 μm) with gradient elution of 20 mM ammonium acetate solution-acetonitrile. CYA was well retained (Rt = 5.10 min) and eluted with good peak shape. The method could respond linearly with CYA at concentrations from 1.0 to 50 ng/mL with a quantification limit of 0.25 mg/kg. The intra- and inter-day precision was less than 4.0% and the recovery of the assay was in the range of 90.4-108.1%. In the analysis of practical spiked pet food samples, the new method yielded satisfactory results. Due to its simplicity and accuracy the straightforward method is particularly suitable for routine CYA detection.  相似文献   

16.
A fast method for the determination of brominated flame retardants (BFRs) in styrenic polymers using microwave-assisted extraction (MAE) and liquid chromatography with UV detection (HPLC-UV) was developed. Different extraction parameters (extraction temperature and time, type of solvent, particle size) were first optimised for standard high-impact polystyrene (HIPS) samples containing known amounts of tetrabromobisphenol A (TBBPA) and decabromodiphenyl ether (Deca-BDE). Complete extraction of TBBPA was achieved using a combination of polar/non-polar solvent system (isopropanol/n-hexane) and high extraction temperatures (130 °C). Lower extraction yields were, however, obtained for Deca-BDE, due to its high molecular weight and its non-polar nature. The developed method was successfully applied to the screening of BFRs in standard plastic samples from waste electrical and electronic equipment (WEEE); TBBPA could be fully recovered, and Deca-BDE could be identified, together with minor order polybrominated diphenyl ether (PBDE) congeners.  相似文献   

17.
The development of an on-line preconcentration system with cloud point extraction for the determination of manganese is described. The system was used to determine manganese levels in food samples using flame atomic absorption spectrometry (FAAS). All steps of the cloud point extraction procedure were performed on-line, from the mixing of reagents to detection. The manganese ions are complexed in a mixture of the reagent 2-[2′-(6-methyl-benzothiazolylazo)]-4-bromophenol (Me-BTABr) and Triton X-114. The components are retained on a minicolumn and then desorbed with eluent acid to subsequent detection of manganese by FAAS. Under the optimized conditions, the method presented a detection limit of 0.7 μg L− 1 and an enrichment factor of 17 to a volume of 3000 μL. The sampling frequency was 30 h− 1. The accuracy of the method was tested by evaluating the amount of Mn in certified reference materials (apple leaves NIST 1515 and spinach leaves NIST 1570a). The proposed procedure was applied to food samples (shrimp powder, flaxseed flour, wheat flour, soy flour and oat), and the results agreed with those obtained by the determination of Mn in foods by atomic absorption spectrometry with electrothermal atomization (ETAAS).  相似文献   

18.
Herein, a covalent organic framework, which was fabricated at room temperature by using 1,3,5-tris(p-formylphenyl) benzene and 1,3,5-tris(4-aminophenyl)benzene as building blocks, was employed as an adsorbent for solid-phase extraction of dyes including congo red, methyl blue and direct red 80 for the first time. The prepared covalent organic framework was properly characterized by different techniques and the results revealed that it had a uniform spherical structure, high crystallinity, satisfactory surface area, and good thermal stability. Moreover, the adsorption performance of the material was explored by using static and dynamic adsorption experiments and the results indicated that the material showed good adsorption capacities for three dyes with adsorption capacities in the range of 55.25–284.10 mg/g and the adsorption equilibrium can be achieved in 15 min. Further, to achieve the best adsorption effects of the material, the influence parameters such as pH, ionic strength, type of desorption solvent, and the material dosage in the solid-phase extraction column, were optimized in turn. Finally, under optimal conditions, the solid-phase extraction coupled with HPLC was applied to the analysis of dyes in food and water samples. The recoveries of dyes in actual samples were satisfactory, revealing the unique applicability of the material in the sample pretreatment field.  相似文献   

19.
The use of 1-phenyl-3-methyl-4-benzoylpyrazolone (PMBP) as extractant for separation of Fe(III) and Fe(II) and low-temperature vaporization of the Fe(III)–PMBP chelate into ICP-AES for their speciation analysis was investigated. The factors affecting the formation of Fe(PMBP)3 chelate and its vaporization behavior were investigated in detail. PMBP was used not only as the extractant for the separation of Fe(III) and Fe(II) but also as the chemical modifier for the low-temperature ETV-ICP-AES determination of iron. Under the optimized conditions, the detection limit for iron(III) and iron(II) are both 3.2?ng/mL, with relative standard deviations of 3.9 and 4.5%, respectively. The proposed method was applied to the determination of trace iron in biological standard reference materials and the species in East Lake water samples, and the results obtained were satisfactory.  相似文献   

20.
Nuno Ratola  Damià Barceló 《Talanta》2009,77(3):1120-1128
Two different extraction strategies (microwave-assisted extraction (MAE) and ultrasonic extraction (USE)) were tested in the extraction of the 16 US Environmental Protection Agency (EPA) polycyclic aromatic hydrocarbons (PAHs) from pine trees. Extraction of needles and bark from two pine species common in the Iberian Peninsula (Pinus pinaster Ait. and Pinus pinea L.) was optimized using two amounts of sample (1 g and 5 g) and two PAHs spiking levels (20 ng/g and 100 ng/g). In all cases, the clean-up procedure following extraction consisted in solid-phase extraction (SPE) with alumina cartridges. Quantification was done by gas chromatography (GC) with mass spectrometry (MS), using five deuterated PAH surrogate standards as internal standards. Limits of detection were globally below 0.2 ng/g. The method was robust for the matrices studied regardless of the extraction procedures. Recovery values between 70 and 130% were reached in most cases, except for high molecular weight PAHs (indeno[1,2,3-cd]pyrene, dibenzo[a,h]anthracene and benzo[ghi]perylene). A field study with naturally contaminated samples from eight sites (four in Portugal and four in Catalonia, Spain) showed that needles are more suitable biomonitors for PAHs, yielding concentrations from 2 to 17 times higher than those found in bark. The levels varied according to the sampling site, with the sum of the individual PAH concentrations between 213 and 1773 ng/g (dry weight). Phenanthrene was the most abundant PAH, followed by fluoranthene, naphthalene and pyrene.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏