首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Air samples containing sulfur compounds are often collected and stored in sample bags prior to analysis. The storage stability of six gaseous sulfur compounds (H2S, CH3SH, DMS, CS2, DMDS and SO2) was compared between two different bag materials (polyvinyl fluoride (PVF) and polyester aluminum (PEA)) at five initial concentrations (1, 10, 100, 1000, and 10,000 ppb). The response factors (RF) of these samples were determined after storage periods of 0, 1, and 3 days by gas chromatography–pulsed flame photometric detector (GC–PFPD) combined with an air server (AS)/thermal desorber (TD) system. Although concentration reduction occurred more rapidly from samples of the high concentration standards (1000 and 10,000 ppb), such trends were not evident in their low concentration counterparts (1, 10, and 100 ppb). As such, temporal changes in RF values and the associated loss rates of most sulfur gases were greatly affected by their initial concentration levels. Moreover, the storability of oxidized sulfur compound (SO2) was greatly distinguished from that of reduced sulfur compounds (RSCs), as the former almost disappeared in the PVF bag even after one day. The results of our study confirm that storability of gaseous sulfur species is affected interactively by such variables as initial gas concentration level, bag material type, and oxidation status with the associated reactivity.  相似文献   

2.
In this study, the sorptive loss patterns for volatile organic compounds were evaluated by gaseous standards containing 13 compounds (benzene, toluene, styrene, p‐xylene, methyl ethyl ketone, methyl isobutyl ketone, isobutyl alcohol, butyl acetate, acetaldehyde, propionaldehyde, butyraldehyde, isovaleraldehyde, and valeraldehyde). The gaseous standards, prepared initially at two contrasting concentration levels (40 and 4000 ppb) in a polyester aluminum bag, were measured after two consecutive transfers into empty bags. It indicates that the percent loss patterns, if assessed for all 13 target compounds, are affected most sensitively by the initial concentration levels of samples to yield 2.62 ± 2.22% (at 40 ppb) and 9.57 ± 6.74% (at 4000 ppb). Moreover, the sorptive loss patterns at high concentration samples (4000 ppb) tend to increase in relation with increasing molecular weight of target compounds, although such pattern disappears in low concentration samples (40 ppb). The observed loss patterns, if evaluated in relation to some key parameters like concentration or compound type, suggest the possibility that the sorptive loss of target compounds in storage media can occur in a predictable manner.  相似文献   

3.
4.
Excess enthalpies (HE), at ambient pressure and T = 298.15 K, have been measured by using a solution calorimeter for the binary liquid mixtures of dimethyl sulphoxide (DMSO) with ketones, as a function of composition. The ketones chosen in the present investigation were methyl ethyl ketone (MEK), methyl isobutyl ketone (MIBK), and cyclohexanone (CH). The HE values are positive over the entire composition range for the three binary mixtures. Furthermore, the (vapour + liquid) equilibrium (VLE) was measured at 715 Torr for these mixtures, of different compositions, with the help of Swietoslawski-ebulliometer. The experimental temperature-mole fraction (t-x) data were used to compute Wilson parameters and then used to calculate the equilibrium vapour-phase compositions as well as the theoretical points for these binary mixtures. These Wilson parameters are used to calculate activity coefficients (γ) and these in turn to calculate excess Gibbs free energy (GE). The intermolecular interactions and structural effects were analyzed on the basis of the measured and derived properties.  相似文献   

5.
Water-insoluble amines (dissolved in an organic solvent/organic solvent mixture) are often used for the extractive recovery of carboxylic acids from aqueous phases. The basic design of the extraction process requires a thermodynamic framework that should be able to describe the liquid–liquid phase equilibrium not only in the phase forming systems (water + carboxylic acid + organic solvent + reactive extractant), but also when the aqueous feed phase contains additionally small amounts of strong electrolytes. Even small amounts of strong electrolytes might considerably reduce the recovery rate. In part I of this series such a model was presented and discussed for methyl isobutyl ketone as organic solvent and tri-n-octylamine (TnOA) as the chemical extractant. The present part II is to demonstrate that the procedures/methods described for methyl isobutyl ketone as organic solvent can be applied also for other organic solvents. By way of example, here toluene is that organic solvent. New experimental results are reported for the influence of sodium chloride, sodium nitrate, sodium sulfate, sodium acetate and hydrochloric acid on the partitioning of acetic acid to coexisting aqueous/organic liquid phases of the system (water + toluene + tri-n-octylamine) at 25 °C. An extension/adaptation of the previously published thermodynamic framework is successfully applied to describe/predict the new experimental liquid–liquid phase equilibrium data.  相似文献   

6.
In this study, the feasibility of GC–MS was evaluated for the quantification of odorous volatile organic compounds (VOCs) in environmental samples. These included methyl ethyl ketone, isobutyl alcohol, methyl isobutyl ketone, and butyl acetate plus benzene, toluene, and xylene (BTX). For this purpose, the gaseous standard for these VOCs were analyzed by GC–MS with the aid of both direct injection (DI) into the GC injector and solid-phase microextraction (SPME). The liquid phase standard prepared independently was tested additionally by the DI method as a reference to gaseous calibration. The detection limit (DL) values, when tested for basic quality assurance in this study, showed large differences between DI (0.002–0.007 ng) and SPME method (1.03–1.81 ng) in terms of absolute mass. The DL values, when expressed in terms of concentration (v/v), showed considerable improvement in SPME (below 0.40 nmol mol−1) relative to the DI method (∼6–15 nmol mol−1). The reliability of the GC–MS method was further validated through an analysis of real environmental samples collected from an industrial area.  相似文献   

7.
A method for speciation, preconcentration and separation of Fe(II) and Fe(III) in different matrices was developed using solvent extraction and flame atomic absorption spectrometry. 4-Acetyl-5-methyl-1-phenyl-1H-pyrazole-3-carboxylic acid (AMPC) was used as a new complexing reagent for Fe(III). The Fe(III)-AMPC complex was extracted into methyl isobutyl ketone (MIBK) phase in the pH range 1.0-2.5, and Fe(II) ion remained in aqueous phase at all pH. The chemical composition of the Fe(III)-AMPC complex was determined by the Job's method. The optimum conditions for quantitative recovery of Fe(III) were determined as pH 1.5, shaking time of 2 min, 1.64 × 10−4 mol L−1 AMPC reagent and 10 mL of MIBK. Furthermore, the influences of diverse metal ions were investigated. The level of Fe(II) was calculated by difference of total iron and Fe(III) concentrations. The detection limit based on the 3σ criterion was found to be 0.24 μg L−1 for Fe(III). The recoveries were higher than 95% and relative standard deviation was less than 2.1% (N = 8). The validation of the procedure was performed by the analysis of two certified standard reference materials. The presented method was applied to the determination of Fe(II) and Fe(III) in tap water, lake water, river water, sea water, fruit juice, cola, and molasses samples with satisfactory results.  相似文献   

8.
A miniaturized methodology for the determination of phosphate in waters has been developed by combining directly suspended droplet microextraction (DSDME) with microvolume spectrophotometry. The method is based on the extraction of the ion pair formed between 12-molybdophosphate and malachite green onto a microdrop of methyl isobutyl ketone and subsequent spectrophotometric determination with no dilution. An enrichment factor of 325 was obtained after 7.5 min of microextraction. The detection limit was 6.1 nM phosphate and the repeatability, expressed as relative standard deviation, was 2.7% (n = 6). The method was successfully applied to the determination of dissolved reactive phosphorus in different freshwater samples.  相似文献   

9.
A rapid and sensitive electrospray ionization tandem mass spectrometric (ESI-MS-MS) procedure was developed for the determination of cyanide (CN). CN in biological fluids was reacted with NaAuCl4 to produce dicyanogold, Au(CN)2, which was extracted with methyl isobutyl ketone (MIBK). One microliter of the extract was injected directly into an ESI-MS-MS instrument. Quantification of CN was performed by selected reaction monitoring of the product ion CN at m/z 26 that derived from precursor ion Au(CN)2 at m/z 249. CN could be measured in the quantification range of 10−7 to 5 × 10−5 M with the limit of detection at 4 × 10−8 M using 10 μL of urine within 10 min. A victim's urine and gastric content were diluted with water to 4-fold and 500-fold and measured, respectively.  相似文献   

10.
Two series of amphiphilic hydrogels of various compositions were prepared by sequentially interpenetrating two polymer networks, a poly(2-hydroxyethyl acrylate) (PHEA) network inside either a macroporous matrix of poly(methyl methacrylate) (PMMA) or a macroporous poly(ethyl acrylate) (PEA) network. In both cases poly(2-hydroxyethyl acrylate) (PHEA) served as network II, and the firstly formed porous network was a hydrophobic homonetwork, PMMA or PEA, that conferred mechanical strength to the hydrogel. In order to obtain hydrogels with high hydrophilic content, the first network was prepared in the presence of a solvent, thus yielding a macroporous network. The two families of IPNs thus obtained were: (net-PMMA)-ipn-(net-PHEA) and (net-PEA)-ipn-(net-PHEA), with a PHEA content ranging from 36% to 87% and from 64% to 94%, respectively. The novelty of the work consisted in comparing the effect of using as the first macroporous network a polymer which is glassy at room temperature (PMMA) and another of the same family (PEA) but which is in the rubber state at room temperature. Swelling studies showed that the specific equilibrium water content of PHEA falls from 1.6 for pure (unconfined) PHEA to values that range from 0.4 to 1, for the (net-PMMA)-ipn-(net-PHEA), whereas in the second IPNs family, the equilibrium water uptake of PHEA phase is, at least, the same as that of the pure PHEA (in some cases it is greater). This means that the expansion of the PHEA phase is not restricted by the confining hydrophobic component when this last is in the rubber state at room temperature. Whereas for the first IPNs the mechanical properties significantly increased (storage modulus at 37 °C from 0.25 to 2.5 GPa) compared with those of pure PHEA (25.12 MPa), little if any reinforcing effect was observed in the second type of IPNs. This is due to the fact that the glass transition of the PEA network takes place at a lower temperature than that of PHEA, so both components are in the rubbery state at room temperature. Both series behave differently also in dynamic water sorption experiments: the rigid PMMA network hinders the diffusion of water, yielding lower values of the apparent diffusion coefficients. By contrast, with the PEA polymer as network I this diffusion is similar to that of the pure PHEA homonetwork.  相似文献   

11.
A novel flow injection (FI) on-line displacement solid phase extraction preconcentration and/or separation method coupled with FAAS in order to minimize interference from other metals was developed for trace silver determination. The proposed method involved the on-line formation and subsequently pre-sorption of lead diethyldithiocarbamate (Pb-DDTC) into a column packed with PTFE-turnings. The preconcentration and/or separation of the Ag(I) took place through a displacement reaction between Ag(I) and Pb(II) of the pre-sorbed Pb-DDTC. Finally, the retained analyte was eluted with isobutyl methyl ketone (IBMK) and delivered directly to nebulizer for measuring. Interference from co-existing ions with lower DDTC complex stability in comparison with Pb-DDTC, was eliminated without need for any masking reagent. With 120 s of preconcentration time at a sample flow rate of 7.6 mL min−1, an enhancement factor of 110 and a detection limit (3 s) of 0.2 μg L−1 were obtained. The precision (RSD, n = 10) was 3.1% at the 10 μg L−1 level. The developed method was successfully applied to trace silver determination in a variety of environmental water samples and certified reference material.  相似文献   

12.
建立用气袋法收集整册印刷品释放的挥发性有机化合物,热解析-气相色谱法检测总挥发性有机化合物(TVOC)的方法。将印刷品样品置入充满高纯氮气的密封PVF采样袋中,在35℃下放置12 h后,用采样器串联Tenax-TA采样管和采样袋,让袋内气体通过采样管,样品释放出的有机化合物被吸附到采样管的吸附剂上。用热解析-气相色谱法测试采样管中挥发性有机化合物的含量,其中苯、甲苯、邻二甲苯、间二甲苯、对二甲苯、乙苯、乙酸丁酯、苯乙烯和正十一烷按外标法定量,其它物质按甲苯标准曲线定量。该方法的加标回收率为74.4%~91.1%,测定结果的相对标准偏差不大于10%(n=9)。该方法的样品采集更贴近印刷品的实际生活场景,可以为评价印刷品挥发性有机物释放对人体健康的影响提供数据基础,为相关评价提供新思路。  相似文献   

13.
Kinetics of the oxidation of methyl n-propyl ketone and methyl isobutyl ketone by N-bromosuccinimide (NBS) have been studied in perchloric acid media in presence of mercuric acetate. A zero order dependence to N-bromosuccinimide and a first order dependence to both ketones and hydrogen ion concentrations have been observed. Sodium perchlorate, mercuric acetate and succinimide additions have negligible effect while methanol addition has a positive effect on the reaction rate. A solvent isotope effect (k0D2O/K0H2O = 2.3-2.7 and 2.4-2.8 for MeCOn.pr and MeCoi-Bu, respectively) has been observed at 35°. Kinetic investigations have revealed that the order of reactivity is methyl n-propyl ketone > methyl isobutyl ketone. Various thermodynamic parameters have been computed and corresponding 1,2-diketones were found to be the products. A suitable mechanism in conformity with the above observations has been proposed.  相似文献   

14.
A study was made of the extraction of zinc from hydrochloric acid solutions with solutions of methyldioctylamine and tri(iso-octyl)amine in methyl isobutyl ketone. Quantitative extraction was accomplished from 2 N hydrochloric acid with 5% (w/v) tri(iso-octyl)amine-methyl isobutyl ketone. A procedure was developed for the colorimetric determination of zinc in the organic phase after extraction using 2-carboxy-2'-hydroxy-5'-sulfoformazylbenzene (Zincon).  相似文献   

15.
The bromo complexes of platinum(IV), palladium(II), rhodium(III), and iridium(IV) were prepared and studies were made on their distribution between hydrobromic acid solutions and various common solvents. The solvents employed were n-tributyl phosphate (TBP), methyl isobutyl ketone, amyl acetate, and various TBP-benzene mixtures. Distribution coefficients as a function of HBr concentration are given for each metal for each solvent system. A careful study of the measured distribution coefficients clearly showed that a number of binary and ternary mixtures of the metals can be resolved with a Craig countercurrent distribution apparatus. Rh-Pt and Rh-Pd mixtures in 4.38M HBr solutions were quantitatively separated on a Io-stage Craig apparatus using a 90% TBP-10% benzene solvent. Rh-Ir mixtures in 4.38 M HBr were resolved by 3 consecutive batch extractions with 90% TBP-10% benzene. Mixtures of Pd, Rh, and Ir in 4.38 M HBr were resolved in 90 stages using methyl isobutyl ketone as the solvent. Pd, Rh and Ir were recovered in 97.0, 87.6 and 94.5% yields, respectively. Mixtures of Pd, Rh and Pt in 4.38 M HBr were resolved in 90 stages using amyl acetate and methyl isobutyl ketone as solvents. Pd, Rh and Pt were recovered in 90.0, 96.0 and 94.0% yields, respectively. Two computer programs for the IBM 1620 Computer are given ; these facilitate the comparison of theoretical and actual solute distributions.  相似文献   

16.
A novel hydrophobic sorbent material for on-line column preconcentration and separation systems coupled with atomic spectrometry was developed. Poly(etheretherketone) (PEEK) in the form of turnings was used as packing material and evaluated for trace lead determination in environmental samples. Sample and ammonium diethyl-dithiophosphate (DDPA) reagent were mixed on-line and the Pb(II)-DDPA complex was retained effectively on PEEK-turnings. Isobutyl methyl ketone (IBMK) was adopted for efficient analyte complex elution and subsequently transportation into the nebulizer-burner system for atomization. The developed sorbent material has shown, excellent chemical and mechanical resistance, fast adsorption kinetics permitting the use of high sample flow rates without significant loss of retention efficiency. For 120 s sample preconcentration time the sampling frequency was 20 h−1, the enhancement factor was 110, the detection limit (3 s) was cL = 0.32 μg L−1, and the relative standard deviation (RSD) was sR = 2.2%, at the 50.0 μg L−1 Pb(II) level. The accuracy of the developed method was evaluated by analyzing certified reference materials.  相似文献   

17.
The kinetics and mechanism of the thermal degradation of poly(diethyl fumarate) (PDEF) were studied by thermogravimetry, as well as by analysis of the thermolysis volatiles and polymer residue. The characteristic mass loss temperatures were determined, as were the overall thermal degradation activation energies of three PDEF samples of varying molar mass. Ethylene and ethanol were present in the thermolysis volatiles at degradation temperatures below 300 °C, while diethyl fumarate was also evidenced at higher degradation temperatures. The amount of monomer increased with increasing degradation temperature. The dependence of the molar mass of the residual polymer on the degradation time and temperature was established and the number of main-chain scissions per monomer unit, s/P0, calculated. A thermal degradation mechanism including de-esterification and random main-chain scission is proposed. The thermal degradation of PDEF was compared to the thermolysis of poly(ethyl methacrylate) (PEMA), poly(diethyl itaconate) (PDEI) and poly(ethyl acrylate) (PEA).  相似文献   

18.
Fluorinated copolymers are well known for their large range of applications. These applications can be improved by grafting or crosslinking of several agents. The mechanism of crosslinking of hexamethylene diamine and 2,4,4-trimethyl-1,6-hexanediamine is well known and occurs in four different steps. To elaborate a film of commercially available poly(VDF-co-HFP) copolymer crosslinked by 2,4,4-trimethyl-1,6-hexanediamine, a step of press cure under air is necessary. Temperature, time and pressure were optimised by regarding the solubility of the press cured films, the mechanical properties, the swelling rate in methyl ethyl ketone, and the degradation of the films. The best temperature, time and pressure for press cure were 150 °C, from 15 to 30 min, and 20 bars, respectively. Other properties of crosslinked poly(VDF-co-HFP) copolymers containing 10 mol.% and 20 mol.% of HFP were characterized. First, all films were insoluble in concentrated HCl. Secondly, swelling rates of different amounts of diamine crosslinked copolymers were measured in ethylene carbonate/dimethyl carbonate and in methyl ethyl ketone; it was proved that the higher the molar percentage of diamine, the higher the crosslinking density, so the lower the swelling rate. Concerning thermal properties, glass transition temperature mainly increased when the amount of diamine increased. Thermal stability measurements showed a higher decomposition temperature when the percentage of diamine was very low (5 mol.%). Finally, mechanical properties were measured by dynamic mechanical analysis; the storage tensile modulus (E′) of a diamine crosslinked Kynar® copolymer versus temperature exhibited a high drop because Kynar® was a highly amorphous copolymer. Moreover, the higher the amount of diamine, the higher the rubbery modulus.  相似文献   

19.
Solvent-free reactions were used for the synthesis of a series of imidazolium-based ionic salts: 3,3′-[pyridine-2,6-diylbis(methylene)]bis(1-R-1H-imidazol-3-ium)chloride; (R = methyl, ethyl, butyl, isobutyl, hexyl, and benzyl). A simple and effective filtration process was used to isolate all the products in high purity and with yields ?93% within a 24 h period. The highly pure ionic compounds which are precursors to N-heterocyclic carbene ligands used in catalysis were fully characterized as gray-white hygroscopic salts.  相似文献   

20.
A method to measure the rate constant for the formation of symmetrical proton-bound dimers at ambient pressure was proposed. The sample is continuously delivered to the drift region of an ion mobility spectrometer where it reacts with a swarm of monomer ions injected by the shutter grid. Dimer ions are formed in the drift tube and a tail appears in the ion mobility spectrum. The rate constant is derived from the mobility spectra. The proposed approach was typically examined for methyl isobutyl ketone (MIBK), 2,4-dimethyl pyridine (DMP), and dimethyl methyl phosphonate (DMMP). The rate constants measured in this study were: 0.25 × 10−9, 0.86 × 10−10, and 0.47 × 10−10 cms−1 for MIBK, DMP and DMMP, respectively. The logarithm of the measured rate constants were found to be almost independent of reciprocal temperature within 303 to 343 K, indicating that no activation energy is involved in the formation of proton-bound dimers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号