首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new gas chromatography/mass spectrometry (GC/MS) system was designed and evaluated which we have named 'Supersonic GC/MS'. It is based on a modification of a commercially available GC/MS system to include a supersonic molecular beam (SMB) MS interface. In this system the standard electron ionization (EI) ion source was replaced with a fly-through EI ion source mounted in the path of the SMB. A hyperthermal surface ionization (HSI) ion source combined with a 90 degrees ion mirror (for the EI-produced ions) was also added, and placed inside the quadrupole mass analyzer in place of its original EI ion source. The 'Supersonic GC/MS' system requires 18 cm added bench space plus the addition of an air-cooled 60 L/s diffusion pump and a 537 L/min rotary pump. The system is user friendly since all the gas flow rates, heated zones, sampling and data analysis are performed the same way as the original system and are computer-controlled via the original software. Similar EI sensitivity was obtained as with the original system for hexachlorobenzene and octafluoronaphthalene, while improved EI detection limits were demonstrated for methyl stearate and eicosane due to the significant enhancement of their molecular ion abundances. A GC/MS detection limit of 500 ag for pyrene was demonstrated using HSI. Good supersonic expansion cooling was achieved with large alkanes, despite the use of a rotary pump at the nozzle chamber instead of a diffusion pump. High temperature GC/MS analysis was demonstrated for large polycyclic aromatic hydrocarbons (PAHs) including ovalene and decacyclene (ten rings). Library searches with EI mass spectra are demonstrated, and it is explained why the enhancement of the molecular ion actually improves the library search in most cases. The analysis of large phthalate esters is also described, and the improvement obtained is shown to originate from their enhanced molecular and high mass fragment ions.  相似文献   

2.
Spectroscopy Laboratory, The Dow Chemical Company, Midland, Michigan, USA In December 1955 or thereabouts, the authors coupled a homemade gas chromatograph to a research time-of-flight mass spectrometer constructed by W. C. Wiley, I. H. McLaren, and D. B. Harrington. This unique gas chromatography/mass spectrometry (GC/MS) instrument generated mass spectra at a lo-kHz rate for display on an oscilloscope; eluted gas chromate graphic components, such as methanol, acetone, benzene, toluene, and carbon tetrachloride, could be visually identified immediately from the oscilloscope display. Many years of further research and development in many laboratories worldwide were necessary, however, to make continuous on-line GC/MS the uniquely valuable analytical tool that it is today.  相似文献   

3.
The incorporation of stable isotopes improves the assessment of glucose metabolism and, with some researchers using two tracers, (2)H-glucose assessed by gas chromatography/mass spectrometry (GC/MS) and (13)C-glucose by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS), a common derivative for both is advantageous. The most commonly used derivatives for GC/MS are inappropriate for GC/C/IRMS as additional functional groups dilute the label. We therefore considered the suitability of six derivatives for both GC/MS and GC/C/IRMS. Glucose alkylboronates were prepared by adding the appropriate alkylboronic acid (butyl- or methylboronic acid) in pyridine to desiccated glucose. The derivatisation was completed by reacting this with either (a) acetic anhydride or trifluoroacetic anhydride (acetate derivatives) or (b) bis(trimethylsilyl)trifluoroacetamide BSTFA (TMS derivatives). All six derivatives were assessed using GC/MS and (13)C GC/C/IRMS.Neither TMS derivative exhibited any signal intensity in the molecular ion, although a M-15 ion showed good agreement between experimental and theoretical data and, whilst still low in intensity, could be suitable for isotope work. Similarly, none of the acetate derivatives showed any intensity at the molecular ion although three key fragmentation series were identified. The most attractive sequence, initiated by the loss of 1,2 cyclic boronate, resulted in the main fragment ion of interest, m/z 240, corresponding to the fluorinated methylboronate derivate. Minimal carbon and hydrogen atoms are added to this derivative making it an excellent choice for stable isotope work, while proving suitable for analysis by both GC/MS and GC/C/IRMS.  相似文献   

4.
5.
The explosive triacetone triperoxide (TATP) has been analyzed by gas chromatography/mass spectrometry (GC/MS) and sub-nanogram detection limits are reported by ammonia positive ion chemical ionization (PICI), electron ionization (EI) and methane negative ion chemical ionization (NICI). Analysis by methane PICI and ammonia NICI gave detection limits in the low nanogram range. Analyses were carried out on (linear) quadrupole and ion trap instruments. Analysis of TATP by PICI using ammonia reagent gas is the preferred analytical method, producing low limits of detection as well as an abundant (greater than 60% of base peak) diagnostic adduct ion at m/z 240 corresponding to [TATP + NH4]+. Isolation of the [TATP + NH4]+ ion with subsequent collision-induced dissociation (CID) produces extremely low abundance product ions at m/z values greater than 60, and the m/z 223 ion corresponding to [TATP + H]+ was not observed. Density functional theory (DFT) calculations at the B88LYP/DVZP level indicate that dissociation of the complex to form NH4+ and TATP occurs at energies lower than peroxide bond dissociation, while protonation of TATP leads to cleavage of the ring structure. These results provide a method for pico-gram detection levels of TATP using commercial instrumentation commonly available in forensic laboratories. As a point of comparison, a detection limit of 15 ng was obtained by flame ionization detection.  相似文献   

6.
7.
The photostability of guaiazulene (1,4-dimethyl-7-isopropylazulene; GA), a natural azulenic compound used in cosmetic and health-care products, as well as in pharmaceutical preparations, was investigated in solution (methanol, ethanol, acetonitrile), by different techniques: gas chromatography/mass spectrometry (GC/MS) and high-performance liquid chromatography combined with atmospheric pressure chemical ionization mass spectrometry and UV detection (LC/APCI-MS and HPLC/UV). A solar simulator (xenon-arc lamp) was used as UV-A radiation source. The study involved: monitoring compound decomposition, identifying products of photodegradation (PPs), assessing the role of oxygen and evaluating the kinetics of the process. Minor PPs are volatile compounds and were characterized by GC/MS, while oligomeric polyoxygenated compounds, tentatively characterized on the basis of MS and MS/MS spectra, were found to be the main photoproducts. The photodegradation was found to be enhanced by the presence of oxygen; nevertheless, determination of the singlet oxygen quantum yield for GA gave a lower value than that for the reference standard Rose Bengal. The obtained results and the developed stability-indicating methods (GC/MS and LC/MS) are of interest for stability studies and/or quality control purposes of GA as raw material or cosmetic products.  相似文献   

8.
The determination of tetra- to octachlorodibenzo-p-dioxins and tetra- to octachlorodibenzofurans (PCCD/Fs) by high-resolution gas chromatography/tandem mass spectrometry (HRGC/MS/MS) and high-resolution gas chromatography/triple mass spectrometry (HRGC/MS(3)) in a quadrupole ion trap, equipped with an external ion source, is presented. MS/MS involves a typical four-step process, namely ionization, parent ion isolation, collision-induced dissociation (CID) and mass analysis of the daughter ions. For the MS(3) experiment, the MS/MS scan function is used with the addition of selected daughter ion isolation, their CID and the mass analysis of second-generation product ions called 'grand-daughter ions.' For both methods, the energies necessary for the CID of the 17 PCDD/Fs were determined and optimized using multiple scan functions with different CID amplitudes. The CID efficiency, defined as the signal ratio of fragment ions detected from the major dissociation channels to molecular ions isolated, was 1.15-2.40 V for parent ion dissociation (MS/MS) and 1.05-1.50 V for daughter ion dissociation (MS(3)) and for all the chloro congeners. The same sensitivity (1 pg microl(-1)) can be reached with both the MS/MS and MS(3) methods and linear responses were obtained between 1 and 100 pg microl(-1) injected.  相似文献   

9.
Two n-heptane-precipitated asphaltene samples, characterized by elemental analysis and nuclear magnetic resonance spectrometry, were fractionated according to relative molecular size by gel permeation chromatography (GPC). Both the whole asphaltene samples and their fractions were analysed by pyrolysis/gas chromatography/mass spectrometry. The data obtained from the pyrograms (average side-chain length, aromaticity index, sulphur compounds vs. aliphatic compounds, presence of SO2 and CO2) demonstrated that, in the case of asphaltenes, GPC fractionation results in the separation of different chemical structures ranging from lower molecular mass, highly aromatic and polar compounds to higher molecular mass, less polar and aromatic compounds.  相似文献   

10.
Using hyphenated analytical techniques, gas chromatography/mass spectrometry (GC/MS) and liquid chromatography/mass spectrometry (LC/MS), a study on minor propofol metabolites in human urine was conducted. These techniques allowed identification of two new phase I metabolites (2-(omega-propanol)-6-isopropylphenol and 2-(omega-propanol)-6-isopropyl-1,4-quinol). In addition, their four corresponding conjugates (three glucuronides and one sulphate) were detected. Thus in human urine at least eight conjugate metabolites are produced, derived from four different aglycones (propofol; 2, 6-diisopropyl-1,4-quinol; 2-(omega-propanol)-6-isopropylphenol and 2-(omega-propanol)-6-isopropyl-1,4-quinol).  相似文献   

11.
A number of polymers were hydrolyzed in NH4OH and studied using gas chromatography/ mass spectrometry (GC/MS) and particle beam liquid chromatography/mass spectrometry (particle beam LC/MS) techniques. The polymers studied in this report were as follows: BPDA-PDA, BPDA-PDA-ODA, BPDA-PDA-GFDA, PMDA-ODA, and BTDA-APB. Some of the polymer samples were hydrolyzed in both their acid and imide forms to see if any mass spectrometric differences could be detected. ln all cases, the acid and imide spectra looked the same. GC/MS was unable to determine either the amine or acid portion of these polymers via a direct injection of the sample, but when the samples were first extracted with diethyl ether and this ether extract was injected into the chromatograph, the amine portion of the polymers was readily detected. The acid portion was, again, not detected in either the sample or the ether extract. The particle beam was able to detect both the amine and acid monomeric units in the nonextracted sample.  相似文献   

12.
The pressure requirements for chemical ionization g.c./F.t.m.s. which restrict mass resolution and accuracy are overcome through use of a pulsed valve that provides momentary reagent gas pressures. For alternate electron impact (EI)/chemical ionization (c.i.) g.c./F.t.m.s., similar resolution for both e.i. and c.i. data is demonstrated. The efficiency of chemical ionization with the pulsed valve is similar to static high pressure c.i. measurements of several model compounds. Results from the analysis of peppermint oil and a fuel additive illustrate the potential information available from a single g.c./F.t.m.s. experiment.  相似文献   

13.
14.
Time-of-flight (TOF) instruments have recently gained popularity in quantitative analyses. Normally, TOF mass spectrometers are used for accurate mass measurements for empirical formula verification. However, over the past decade, they have been used quantitatively as well. Because of the fast separations and narrow peaks that result from gas chromatography separations, scanning mass spectrometers are not ideal detectors. TOF mass spectrometers, however, have the ability to collect spectra at a faster rate. Two-dimensional gas chromatography has also been introduced to further resolve peaks from complex matrices. Two-dimensional gas chromatography results in a faster separation as well as narrower peaks. This paper reviews the methods currently in the literature for the quantitation of compounds using one- and two-dimensional gas chromatography and TOF mass spectrometry detection.  相似文献   

15.
Su J  Lu S  Chen J  Chen J  Liang Z  Liu J 《色谱》2011,29(7):643-655
以溶剂转移净化为核心步骤,建立了一种适用于大蒜样品中农药多残留分析的前处理方法(方法I),配以一个辅助方法(方法II),构成大蒜中常见289种农药多残留的分析体系(方法I283种,方法II6种)。方法I中,样品用乙腈-水溶液提取,盐析分配,溶剂转移和固相萃取(SPE)净化后进行气相色谱-质谱(GC-MS)分析;方法II中,样品用无水Na2SO4配合乙酸乙酯均质研磨,超声波辅助提取,提取液经Primary Secondary Amine (PSA)粉末分散固相萃取和LC-Si柱选择洗脱净化后进行GC分析。GC-MS采用选择离子监测(SIM)方式,GC采用火焰光度检测器(FPD)检测,外标法定量。方法简便、快速,通过优化前处理和上机条件,在最优条件下进行测试,方法的定量限(S/N≥10)为0.01~0.05 mg/kg。方法I中,在加标水平为0.02、0.20 mg/kg时,回收率为52%~163%,其中回收率在70%~120%之间的占88%,相对标准偏差为2.4%~18%;方法II中,在加标水平为0.01、0.02、0.10、0.20 mg/kg时,回收率为70%~111%,相对标准偏差为3.2%~9.3%。详细描述了实验模型的构建,并对GC-MS灵敏度的提高提出了新的见解。该方法准确、灵敏、快速,可满足大蒜中多种农药残留的检测要求。  相似文献   

16.
Two fibre-optic interfaces were constructed for laser photodissociation/tandem mass spectrometry using an ion trap spectrometer. These interfaces allow sample introduction from a liquid reservoir, solids probe and gas chromatograph. The laser/ion trap configuration was applied to the analysis of a mixture of alkylbenenes separated by gas chromatography using 573 nm photons.  相似文献   

17.
Amino acids containing natural-abundance levels of 15N were derivatized and analyzed isotopically using a technique in which individual compounds are separated by gas chromatography, combusted on-line, and the product stream sent directly to an isotope-ratio mass spectrometer. For samples of N2 gas, standard deviations of ratio measurement were better than 0.1‰ (Units for δ are parts per thousand or per million (‰).) for samples larger than 400 pmol and better than 0.5‰ for samples larger than 25 pmol (0.1‰ 15N is equivalent to 0.00004 atom % 15N). Results duplicated those of conventional, batchwise analyses to within 0.05‰. For combustion of organic compounds yielding CO2/N2 ratios between 14 and 28, in particular for N-acetyl n-propyl derivatives of amino acids, δ values were within 0.25‰ of results obtained using conventional techniques and standard deviations were better than 0.35‰. Pooled data for measurements of all amino acids produced an accuracy and precision of 0.04 and 0.23‰, respectively, when 2 mnol of each amino acid was injected on column and 20% of the stream of combustion products was delivered to the mass spectrometer.  相似文献   

18.
Nandrolone (19‐nortestosterone) is an androgenic anabolic steroid illegally used as a growth‐promoting agent in animal breeding and as a performance enhancer in athletics. Therefore, its use was officially banned in 1974 by the Medical Commission of the International Olympic Committee (IOC). Following nandrolone administration, the main metabolites in humans are 19‐norandrosterone, 19‐norethiocolanolone and 19‐norepiandrosterone, and their presence in urine is the basis of detecting its abuse. The present work was undertaken to determine, in human urine, nandrolone metabolites (phase I and phase II) by developing and comparing multiresidue liquid chromatography/tandem mass spectrometry (LC/MS/MS) and gas chromatography/mass spectrometry (GC/MS) methods. A double extraction by solid‐phase extraction (SPE) was necessary for the complete elimination of the interfering compounds. The proposed methods were also tested on a real positive sample, and they allow us to determine the conjugated/free fractions ratio reducing the risk of false positive or misleading results and they should allow laboratories involved in doping control analysis to monitor the illegal use of steroids. The advantages of LC/MS/MS over GC/MS (which is the technique mainly used) include the elimination of the hydrolysis and derivatization steps: it is known that during enzymatic hydrolysis several steroids can be converted into related compounds and deconjugation is not always 100% effective. The validation parameters for the two methods were similar (limit of quantification (LOQ) <1 ng/mL and percentage coefficient of variance (CV%) <16.4), and both were able to confirm unambiguously all the analytes, thus confirming the validity of both techniques. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

19.
Boldione (1,4-androstadiene-3,17-dione) is a direct precursor (prohormone) to the anabolic steroid boldenone (1,4-androstadiene-17beta-ol-3-one). It is advertised as a highly anabolic/androgenic compound promoting muscularity, enhancing strength and overall physical performance, and is available on the Internet and in health stores. This work was undertaken to determine and characterize boldione and its metabolites in human urine, using both liquid chromatography with electrospray ionization mass spectrometry and gas chromatography with mass spectrometry and derivatization. Boldione and its three metabolites were detected in dosed human urine after dosing a healthy volunteer with 100 mg boldione. The excretion studies showed that boldione and its metabolites were detectable in urine for 48 h after oral administration, with maximum excretion rates after 1.8 and 3.6 h (boldenone case). The amounts of boldione and boldenone excreted in urine from this 100 mg dose were 34.45 and 15.95 mg, respectively.  相似文献   

20.
Both co- and terpolysulfones have been flash-pyrolyzed at high temperature followed by separation and identification of the products by gas chromatography and/or gas chromatography/mass spectrometry. As expected, most of the products were the corresponding olefin and SO2. Additionally, higher molecular weight products, including aromatics, and olefin isomerization products, were produced. Mechanisms for initiation and formation of the higher molecular weight products are presented which include the back reaction of intermediate free radicals to abstract hydrogen or to form C? C bonds followed by expulsion of SO2. The free-radical intermediates formed by the SO2 expulsion undergo transformations to give the aromatic products. No breakdown products were found with either O or S present, nor was SO2H found.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号