 共查询到20条相似文献,搜索用时 31 毫秒
1.
For a single peak, mass spectral resolution can be expressed in terms of peak width or ratio of peak position to peak width. Alternatively, for two equally intense peaks of equal width, resolution can be defined as the minimum peak separation such that the height of the valley between the combined peaks is less than a specified ratio (1%, 10%, 50%, 100%) of the individual (or combined) peak maximum. All these definitions depend on peak shape. Conversion formulae between various mass resolution criteria are presented for each of eight spectral peak shapes: Gaussian, triangular, trapezoidal, Lorentzian (absorption-mode, magnitude-mode, and sine-apodized magnitude-mode), and sinc (absorption-mode and magnitude-mode). From these formulae, mass resolutions based upon different criteria are readily compared for the same or different line shapes.  相似文献   

2.
3.
By electrospray ionization (ESI) mass spectrometry, micelle solutions of sodium cholate were investigated in detail in the presence and absence of ethanol. The average aggregation number could be evaluated from the spectra acquired under conditions where soft collisions adequate to measure the micelle solution were induced, and the value agreed well with that obtained previously by other methods. From the dependence on ethanol content, it was also found that the average aggregation number in aqueous solution without organic solvent could be reliably estimated. The ESI method proved to be a useful tool for determining the micelle mass in the original aqueous phase.  相似文献   

4.
5.
Mass defect is defined as the difference between a compound's exact mass and its nominal mass. This concept has been increasingly used in mass spectrometry over the years, mainly due to the growing use of high resolution mass spectrometers capable of exact mass measurements in many application areas in analytical and bioanalytical chemistry. This article is meant as an introduction to the different uses of mass defect in applications using modern MS instrumentation. Visualizing complex mass spectra may be simplified with the concept of Kendrick mass by plotting nominal mass as a function of Kendrick mass defect, based on hydrocarbons subunits, as well as slight variations on this theme. Mass defect filtering of complex MS data has been used for selectively detecting compounds of interest, including drugs and their metabolites or endogenous compounds such as peptides and small molecule metabolites. Several strategies have been applied for labeling analytes with reagents containing unique mass defect features, thus shifting molecules into a less noisy area in the mass spectrum, thus increasing their detectability, especially in the area of proteomics. All these concepts will be covered to introduce the interested reader to the plethora of possibilities of mass defect analysis of high resolution mass spectra. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

6.
Mass spectrometers that use different types of analyzers for the first and second stages of mass analysis in tandem mass spectrometry (MS/MS) experiments are often referred to as "hybrid" mass spectrometers. The general goal in the design of a hybrid instrument is to combine different performance characteristics offered by various types of analyzers into one mass spectrometer. These performance characteristics may include mass resolving power, the ion kinetic energy for collision-induced dissociation, and speed of analysis. This paper provides a review of the development of hybrid instruments over the last 30 years for analytical applications.  相似文献   

7.
With the emergence of top-down proteomics, the ability to achieve high mass measurement accuracy on tandem MS/MS data will be beneficial for protein identification and characterization. (FT-ICR) Fourier transform ion cyclotron resonance mass spectrometers are the ideal instruments to perform these experiments with their ability to provide high resolution and mass accuracy. A major limitation to mass measurement accuracy in FT-ICR instruments arises from the occurrence of space charge effects. These space charge effects shift the cyclotron frequency of the ions, which compromises the mass measurement accuracy. While several methods have been developed that correct these space charge effects, they have limitations when applied to MS/MS experiments. It has already been shown that additional information inherent in electrospray spectra can be used for improved mass measurement accuracy with the use of a computer algorithm called DeCAL (deconvolution of Coulombic affected linearity). This paper highlights a new application of the strategy for improved mass accuracy in tandem mass analysis. The results show a significant improvement in mass measurement accuracy on complex electron capture dissociation spectra of proteins. We also demonstrate how the improvement in mass accuracy can increase the confidence in protein identification from the fragment masses of proteins acquired in MS/MS experiments.  相似文献   

8.
9.
10.
The qualitative and quantitative identification of low mass isotopes in the mass range 1–6 u poses certain difficulties when attempting to achieve the required resolution with an instrument suitable for deployment within a process environment. Certain adjacent species present in the process sample (HT and D2) require a resolution greater than 930 to achieve an accurate measurement. We demonstrate here through simulation techniques that this level of performance required is unachievable using commercially available instruments. Using previously reported simulation techniques, this article demonstrates how the required performance for resolving the low mass isotopes can be achieved by a quadrupole mass spectrometer (QMS), which incorporates a quadrupole mass filter (QMF) constructed from hyperbolic electrodes and operated in zone 3 of the Mathieu stability diagram.  相似文献   

11.
Mass cytometry is an emerging powerful bioanalytical technique for high-dimensional single-cell analysis. In this technique, cells are stained with metal-isotope-tagged antibodies and are analyzed by an inductively coupled plasma time-of-flight mass spectrometer. While there are more than 100 stable isotopes available in the m/z 75 to 209 detection range of the instrument, only about 50 parameters can be measured per cell because current reagents are metal-chelating polymers with pendant aminocarboxylate chelators that only bind hard metal ions such as the rare earths and Bi3+. Here we describe the synthesis and characterization of a new type of metal-chelating polymer with pendant dipicolylamine chelators suited to binding intermediate to soft metals such as rhenium and platinum. We introduce two different conjugation strategies, a thiol–maleimide reaction that works well for rhenium, and a DBCO-azide click reaction designed to avoid potential complications of Pt and other heavy metals interacting with thiol groups. We show that these polymers can serve as new elemental mass tags for mass cytometry. Antibody-polymer conjugates of CD20 and CD8a prepared by both coupling reactions were employed in conjunction with commercial metal-conjugated antibodies for multi-parameter single-cell immunoassays.

A new type of metal-chelating polymer with pendant dipicolylamine chelators that bind rhenium and platinum has been developed for mass cytometry applications.  相似文献   

12.
Pressure dependence of several reversed phase liquid chromatographic solvents, including methanol, acetonitrile and mixtures of methanol: water and acetonitrile: water has been investigated. Typical ions, [MH]+, [2M+H]+ and [3M+H]+, were recorded as function of source pressure and as a function of the amount of water in the mixture. Ion formation processes in methanol: water and acetonitrile: water are discussed. The influence of liquid chromatographic mass spectrometric solvent pressure on the mass spectra of samples has been demonstrated on an amino acid sample.  相似文献   

13.
Dynamic range of mass accuracy in LTQ orbitrap hybrid mass spectrometer   总被引:1,自引:0,他引:1  
Using a novel orbitrap mass spectrometer, the authors investigate the dynamic range over which accurate masses can be determined (extent of mass accuracy) for short duration experiments typical for LC/MS. A linear ion trap is used to selectively fill an intermediate ion storage device (C-trap) with ions of interest, following which the ensemble of ions is injected into an orbitrap mass analyzer and analyzed using image current detection and fast Fourier transformation. Using this technique, it is possible to generate ion populations with intraspectrum intensity ranges up to 10(4). All measurements (including ion accumulation and image current detection) were performed in less than 1 s at a resolving power of 30,000. It was shown that 5-ppm mass accuracy of the orbitrap mass analyzer is reached with >95% probability at a dynamic range of more than 5000, which is at least an order of magnitude higher than typical values for time-of-flight instruments. Due to the high resolving power of the orbitrap, accurate mass of an ion could be determined when the signal was reliably distinguished from noise (S/Np-p)>2...3).  相似文献   

14.
The Naval Research Laboratory’s Trace Element AMS system’s use of a Pretzel magnet as a recombinator and mass filter offers a unique opportunity to study a new type of time-of-flight (TOF) spectrometry. Mass filtering prior to TOF analysis removes extraneous species, shortening the analysis time for a single beam pulse, thereby improving the duty cycle. Time dilation results from a longer flight path for a heavier mass in the Pretzel magnet. Computer TOF simulations of these factors and the resulting impact on mass resolution for high mass atomic and molecular species are discussed. Initial measurements of carbon and silicon to confirm the validity of the model are presented.  相似文献   

15.
A series of six bimetallic oxovanadium complexes (1-6; only one was purified) were investigated by electrospray quadrupole time-of-flight tandem mass spectrometry (ESI-QTOF-MS/MS) in negative-ion mode. Radical molecular anions [M](.-) were observed in MS mode. Fragmentation patterns of [M](.-) were proposed, and elemental compositions of most of the product ions were confirmed on the basis of the high-resolution ESI-CID-MS/MS spectra. A complicated series of low-abundance product ions similar to electron impact (EI) ionization spectra indicated the radical character of the precursor ions. Fragment ions at m/z 214, 200, and 182 seem to be the characteristic ions of bimetallic oxovanadium complexes. These ions implied the presence of a V-O-V bridge bond, which might contribute to stabilization of the radical. To obtain more information for structural elucidation, three representative bimetallic oxovanadium complexes (1-3) were analyzed further by MS in positive-ion mode. Positive-ion ESI-MS produced adduct ions of [M + H](+), [M + Na](+), and [M + K](+). The fragmentation patterns of [M + Na](+) were different than those of radical molecular anions [M](.-). Relatively simple fragmentation occurred for [M + Na](+), possibly due to even-electron ion character. Negative-ion MS and MS/MS spectra of the hydrolysis product of Complex 1 supported these finding, in particular, the existence of a V-O-V bridge bond.  相似文献   

16.
Stepwise-external calibration has previously been shown to produce sub part-per-million (ppm) mass accuracy for the MALDI-FTICR/MS analyses of peptides up to m/z 2500. The present work extends these results to ions up to m/z 4000. Mass measurement errors for ions of higher mass-to-charge are larger than for ions below m/z 2500 when using conventional chirp excitation to detect ions. Mass accuracy obtained by using stored waveform inverse Fourier transform (SWIFT) excitation was evaluated and compared with chirp excitation. Analysis of measurement errors reveals that SWIFT excitation provides smaller deviations from the calibration equation and better mass accuracy than chirp excitation for a wide mass range and for widely varying ion populations.  相似文献   

17.
Heparin and low molecular mass heparin (LMMH) consists of complex mixtures of sulphated linear oligosaccharides that are difficult to analyse. An on-line size exclusion chromatographic/electrospray ionization (ESI) mass spectrometric method that allows the determination of more than 60 components in an LMMH preparation is presented. The experimental setup includes on-line cation exchange in order to prevent massive adducting in the ESI interface.  相似文献   

18.
The mass spectrometric fragmentation behaviour of pyridazine and four monosubstituted derivatives containing a pbenylalkyl side-chain (3- and 4-benizylpyridazine, 3- and 4-(2-pbenylethyl)pyridazine) was investigated. In the electron impact ionization mess spectra of the 3-substituted compounds abundant [M – H]+ peaks are observed. This allows a clear distinction between 3- and 4-substituted pyridazines, as the spectra of the latter isomers show only very weak [M – H]+ signals. The stability of [M – H]+ ions derived from 3-alkylpyridazines (deduced from only the very low abundance of further fragment ions) gives strong evidence for a cyclic structure of these ions. One fragmentation pathway typical of the parent pyridazine, the [M - N2] fragmentation, was not detectable with any of the phenylalkylpyridazines investigated. Instead, loss of HCN, H3CN+ and N2H+ was observed. An interesting fragmentation, observed with 3-(2-phenylethyl)pyridazine, is the loss of +CH3 from the molecular ion and also from the [M – H]+ ion.  相似文献   

19.
Nine monosaccharides and four disaccharides were mass analyzed using a quadrupole time-of-flight tandem mass spectrometer combined with an electrospray ionization source. Product ion mass spectra of deprotonated, protonated, and sodiated saccharides were observed and were compared within each group of saccharides. Each of the deprotonated pentoses, hexoses and disaccharides yielded a significantly different product ion mass spectrum with the exception of alpha-lactose and beta-lactose. The disaccharides alpha- and beta-lactose differ only at the glycosidic linkage. Product ion mass spectra of protonated and sodiated alpha- and beta-lactose were indistinguishable also.  相似文献   

20.
The individual mass spectral peaks produced by a quadrupole mass spectrometer (QMS) are asymmetric; they exhibit a 'tail' on the low mass side. In some cases a definite structure is observed in the tail. We show that the tail structure is a consequence of the use of circular electrodes. An extreme case of an experimentally observed QMS mass peak with a distinct tail structure is shown and the general form is reproduced using our numerical model. The effect of instrument resolution, length, operating frequency, ion energy, mass and ion source aperture upon the tail structure are considered. Results show that extensive long tails originate mainly from ions that enter the mass filter at a relatively large distance from the QMS axis; also no significant tail is produced in the case of ideal hyperbolic form electrodes of finite length.  相似文献   