首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
[5,10,15,20-Tetrakis(4-N,N-dimethylaminobenzene)porphyrinato]Mn(III) acetate (MnTDPAc) was applied as an ionophore for an iodide-selective PVC membrane electrode. The influences of the membrane composition, pH of the test solution and foreign ions on the electrode performance were investigated. The sensor exhibited not only excellent selectivity to iodide ion compared to Cl- and lipophilic anions such as ClO4- and salicylate, but also a Nernstian response with a slope of -59.4 +/- 1.2 mV per decade for iodide ions over a wide concentration range from 1.0 x 10(-2) to 7.5 x 10(-6) M at 25 degrees C. The potentiometric response was independent of the pH of the solution in the pH range of 2 - 8. The electrode could be used for at least 2 months without any considerable divergence in the potential. Good selectivity for iodide ion, a very short response time, simple preparation and relatively long-term stability were the silent characteristics of this electrode. It was successfully used as an indicator electrode in the potentiometric titration of iodide ions, and also in the determination of iodide from seawater samples and drug formulations.  相似文献   

2.
A new solvent polymeric membrane electrode based on N,N'-bis-(dimethylaminobenzaldehyde)-glycine cobalt(II) [Co(II)-BDMABG] as a neutral carrier is described, which displays a preferential potentiometric response to iodide ion and an anti-Hofmeister selectivity sequence in the following order: I- > ClO4- > Sal- > SCN- > NO2- > Br- > NO3- > Cl- > SO3(2-) > SO4(2-). The electrode exhibits a near-Nernstian potential linear range of 9.0 x 10(-7)-1.0 x 10(-1) M with a detection limit of 6.8 x 10(-7) M and a slope of -53.0 mV/decade in pH 2.0 of a phosphate buffer solution at 20 degrees C. The response mechanism is discussed in view of the A.C. impedance technique and the UV spectroscopy technique. The electrode was successfully applied to the determination of iodide in Jialing River and Spring in Jinyun Mountains with satisfactory results.  相似文献   

3.
A new salicylate-selective PVC membrane electrode based on a new Schiff base tetranuclear copper complex of O-vannlin-methionine (Cu(II)(4)-TVM) as a neutral carrier is described. This electrode displays a preferential potentiometric response to salicylate and an anti-Hofmeister selectivity sequence in the following order: Sal(-) > ClO(4)(-) > SCN(-) > I(-) > NO(2)(-) > NO(3)(-) > Br(-) > Cl(-) > SO(3)(2-) > SO(4)(2-) > H(2)PO(4)(-). The electrode exhibits near-Nernstian potential linear range of 1.5 x 10(-6)-1.0 x 10(-1) M with a detection limit of 8.0 x 10(-7) M and a slope of -56.3 mV/decade in pH 3.0-8.0 of phosphorate buffer solution at 20 degrees C. Thanks to the tetranuclear copper(II) in the carrier, the electrode has the advantages of simplicity, fast response, fair stability and reproducibility and low detection limit. The response mechanism to the electrodes is discussed by the a.c. impedance technique and the UV spectroscopy technique. The electrode can be applied to analyses of medicine and the results obtained are in fair agreement with the results given by a standard method.  相似文献   

4.
In this paper, the synthesis of a novel ionophore, chloro[5,10,15,20-tetrakis[2-(2,3,4,6-tetraacetyl-beta-D-glucopyranosyl)-1-O-phenyl]porphinato]manganese (MnT(o-glu)PPCl), and its application as a neutral carrier for a PVC membrane electrode are described. The MnT(o-glu)PPCl-based PVC membrane electrode shows a potentiometric responses to SCN- over a concentration range of 3.4 x 10(-7) - 1.0 x 10(-1) mol L(-1) with a Nernstian slope and a response time of 20 s. The electrode exhibits an anti-Hofmeister selectivity toward SCN- with respect to common coexisting anions. As active materials, MnT(o-glu)PPCl shows better selectivity toward SCN- than chloro(tetraphenylporphinato)manganese (MnTPPCl). The effect of the electrode membrane compositions has been studied and the experimental conditions were optimized. The electrode was applied to the determination of SCN- in body fluids with satisfactory results.  相似文献   

5.
双安息香缩三乙四胺双核钴硫氰酸根的离子电极研究   总被引:16,自引:0,他引:16  
季铵盐型阴离子选择性电极由于其电位选择性往往表现出Hofmeister顺序,故使其应用受到限制,因此,研究呈现反Hofmeister行为的阴离子选择性电极已成为离子电极研究领域中重要的研究方向之一。近年来,人们研制出了以金属配合物为中性载体且呈现反Hofmeister行为的阴离子选择电极,本实验室也分别研究了以Schiff碱金属配合物及二氮杂四烯基金属配合物为载体的碘离子和水杨酸根离子电极,但上述电极多数是以单核金属配合物为载体,以双核金属配合物作为载体的电极则很少。  相似文献   

6.
A PVC membrane electrode based on a cadmium-salen (N,N'-bis-salicylidene-1,2-ethylenediamine) complex as an anion carrier is described. The electrode has an anti-Hofmeister selectivity sequence with a preference for thiocyanate at pH 1.5-11.0. It has a linear response to thiocyanate from 1.0 x 10(-6) to 1.0 x 10(-1) mol L(-1) with a slope of 59.1 +/- 0.2 mV per decade, and a detection limit of 7 x 10(-7) mol L(-1). This electrode has high selectivity for thiocyanate relative to many common organic and inorganic anions. The proposed sensor has a fast response time of approximately 15 s. It was applied to the determination of thiocyanate in a milk sample.  相似文献   

7.
The potentiometric anion selectivity of two polymer membrane based electrodes (I and II) formulated with two new cyclopalladated amine complexes as the active components are examined. The electrodes exhibit a non-Hofmeister selectivity pattern with a significantly enhanced response towards thiocyanate, iodide and nitrite. The graph potential versus log c is linear over the concentration range 10(-6)-6x10(-2) M thiocyanate with electrode I and 10(-6)-10(-3) M with electrode II; 10(-5)-10(-2) M iodide with electrode I and 10(-3)-6x10(-2) M with electrode II; and 10(-3)-6x10(-2) M nitrite with both electrodes. The influence of the plasticizer and pH are studied. The potentiometric selectivity coefficients for I, II and blank membrane electrodes are reported. The selective interaction between Pd(II) thiocyanate, iodide and nitrite is postulated to be the reason for its higher response.  相似文献   

8.
A novel selective thiocyanate electrode of a PVC membrane based on bis-[N-(2-hydroxyethyl)salicylaldimino]copper(II) [Cu(II)-BNSDM] as a neutral carrier is reported. The selectivity sequence of this electrode is as follows: SCN- > ClO4- > I- > Sal- > Br- > NO2- > Cl- > NO3- > H2PO4- > SO4(2-), which is an anti-Hofmeister selectivity sequence. The electrode exhibits a Nernstian potential linear range to thiocyanate from 1.0 x 10(-1) to 6.0 x 10(-6) mol/L with a detection limit of 2.0 x 10(-6) mol/L and a slope of (-59.0+/-0.2)mV/decade in pH 5.0 of a phosphate buffer solution at 25 degrees C. Electrochemical impedance spectroscopy (EIS) and UV spectroscopy techniques were performed to understand the response mechanism of the electrode. The electrode had the advantage of simplicity, high selectivity, fast response and low detection limit compared with the other electrode, which had been reported before. The electrode had been applied to wastewater analysis, and the obtained results were satisfactory.  相似文献   

9.
Arvand M  Asadollahzadeh SA 《Talanta》2008,75(4):1046-1054
A novel ion-selective PVC membrane sensor for Al(III) ions based on 6-(4-nitrophenyl)-2-phenyl-4-(thiophen-2-yl)-3,5-diaza-bicyclo[3.1.0]hex-2-ene (NTDH) as a new ionophore has been prepared and studied. The electrode exhibit a good response for aluminum ion over concentration range of 1.0x10(-6) to 1.0x10(-1) mol L(-1) with a Nernstian slope of 19.6+/-0.4 mV per decade and low detection limit of 6.3x10(-7) mol L(-1). The best performance was obtained with membrane composition 30% poly(vinyl chloride), 62% acetophenone, 5% oleic acid, 3% ionophore and 2 ml tetrahydrofuran. NTDH-based electrode was suitable for aqueous solutions of pH 3. It has relatively fast response time (approximately 10 s) and can be used at least for 3 months without any considerable divergence in potentials. The proposed membrane electrode revealed good selectivity for Al(III) ions over a wide variety of other cations. The standard electrode potentials were determined at different temperatures and used to calculate the isothermal coefficient of the electrode. The formation constant and stoichiometry ratio of ionophore-Al(III) complex were calculated at 25 degrees C by using segmented sandwich membrane method. It was used in non-aqueous solvents and also as indicator electrode in potentiometric determination of Al(III) ions in some real samples.  相似文献   

10.
The preparation and application of an iodide ion-selective electrode, prepared by chemical treatment of a silver wire with Hg(2+) is described. The electrode is suitable for the direct potentiometric measurement of iodide in aqueous solutions with concentrations down to 1 x 10(-6) mol/L. It can be used for potentiometric measurements of various compounds (vitamin C, glutathione).  相似文献   

11.
A highly selective PVC membrane electrode based on a cerium-salen complex was prepared. The sensor displays an anti-Hofmeister selectivity sequence with a preference for iodide ion over many common organic and inorganic anions. The proposed electrode exhibits a near-Nernstian behavior over a wide concentration range (5.0 x 10(-2) - 8.0 x 10(-6) M) with a slope of 57.5 mV per decade, and a detection limit of 6.0 x 10(-6) M. The electrode has a very fast response time and can be used in the pH range of 3.0 - 1 1.0. It was applied, as an indicator electrode, in potentiometric titration of Ag+ ions.  相似文献   

12.
In this paper, a new PVC-based liquid-membrane anion-selective electrode based on a copper(II) of N,N'-bis(salicylidene)-1,2-bis(p-aminophenoxy)ethane tetradentate complex (Cu(II)BBAP) is described, which displays a preferential potentiometric response to iodide ion at pH 2.0 and an anti-Hofmeister selectivity sequence: I->SCN->ClO4->NO2->H2PO4->NO3->SO4(2-)>Br->Cl-. The electrode exhibits a near-Nernstian potential linear range of 8.2x10(-7)-1.0x10(-1) M with a detection limit of 5.3x10(-7) M and a slope of -58.8 mV per decade. The A.C. impedance technique and the UV/Vis spectroscopy technique were used to analyze the response mechanism. The electrode could be applied to determine iodide in medicine analysis, and the obtained results were fairly satisfactory.  相似文献   

13.
A new modified carbon paste electrode (CPE) based on a recently synthesized Schiff base complex of Fe(III) as a suitable carrier for I ion is described. The electrode exhibits a super Nernstian slope of 71.0±0.3 mV per decade for I ion over a wide concentration range from 1.0×10−6 to 5.0×10−1 M, with a low detection limit of 6.5×10−7 M. It has a relatively fast response time, a satisfactory reproducibility and relatively long life time. The proposed sensor shows a fairly good selectivity toward I ion in comparison to other common anions. The potentiometric response is independent of the pH of the test solution in the pH range 3.5–10.0. Spectrophotometric studies confirmed the redox-type response mechanism of the electrode toward iodide ion. The proposed electrode was used as an indicator electrode in potentiometric titration of iodide ion.  相似文献   

14.
Two new terpyridine dimanganese oxo complexes [Mn(2)(III,IV)(mu-O)(2)(terpy)(2)(CF(3)CO(2))(2)](+) (3) and [Mn(2)(III,III)(mu-O)(terpy)(2)(CF(3)CO(2))(4)] (4) (terpy = 2,2':6,2' '-terpyridine) have been synthesized and their X-ray structures determined. In contrast to the corresponding mixed-valent aqua complex [Mn(2)(III,IV)(mu-O)(2)(terpy)(2)(H(2)O)(2)](3+) (1), the two Mn atoms in 3 are not crystallographically equivalent. The neutral binuclear monooxo manganese(III,III) complex 4 exhibits two crystallographic forms having cis and trans configurations. In the cis complex, the two CF(3)CO(2)(-) ligands on each manganese adopt a cis geometry to each other; one CF(3)CO(2)(-) is trans to the oxygen of the oxo bridge while the second is cis. In the trans complex, the two coordinated CF(3)CO(2)(-) have a trans geometry to each other and are cis to the oxo bridge. The electrochemical behavior of 3 in organic medium (CH(3)CN) shows that this complex could be oxidized into its corresponding stable manganese(IV,IV) species while its reduced form manganese(III,III) is very unstable and leads by a disproportionation process to Mn(II) and Mn(IV) complexes. Complex 4 is only stable in the solid state, and it disproportionates spontaneously in CH(3)CN solution into the mixed-valent complex 3 and the mononuclear complex [Mn(II)(terpy)(2)](2+) (2), thereby preventing the observation of its electrochemical behavior.  相似文献   

15.
This work describes the development and fabrication of a selective polymeric membrane electrode for iodide ion based on a metallophthalocyanin complex with a titanium(IV) atom at the center (as an oxo-titanium, Ti=O, group), phthalocyaninatotitanium(IV) oxide (PcTiO), as a sensing carrier. The potential response characteristics of the electrode were investigated by changing the type of plasticizer as well as the amounts of the carrier and different lipophilic ionic site additives in the sensing membrane. It is shown that the membrane electrode incorporated with 2-nitrophenyl octyl ether as the plasticizer and hexadecyl trimethylammonium bromide as the appropriate cationic additive exhibits enhanced potential response toward iodide over other anions tested. Over the period of this study, the resulting electrode based on PcTiO displayed a stable near-Nernstian slope approaching -58.9 mV decade(-1) with a linear response spanning at least 5 orders of magnitude in concentration from 1.0 x 10(-1) to 9.2 x 10(-7) mol L(-1) and a detection limit of 8.5-10(-7) mol L(-1). The preferential potential response to iodide may be attributed to the unique recognition of carrier PcTiO in the organic membrane phase for iodide in solution. Under laboratory conditions, the present electrode also works well in partially nonaqueous media. The excellent analytical features of the proposed electrode could lead to its successful application in determining the end point in electrometric titration of iodide with Ag(+) and the direct potential determination of iodide concentration in wastewater and drug preparations.  相似文献   

16.
A polyvinyl chloride (PVC) membrane based Pr(III) selective electrode was constructed using 1,6,7,12‐tetramine‐2,5,8,11‐tetraoxo‐1(12),6(7)‐di(biphenyl)dodecane (TATODBDD) as a neutral carrier. The sensor exhibits a Nernstian response for Pr(III) ions, a wide concentration range of 3.9×10?7?1.0×10?1 mol/L with a detection limit of 5.0×10?8 mol/L and slope of 19.5 mV/decade. The developed sensor revealed relatively good selectivity and high sensitivity for Pr(III) ions over the other lanthanide ions. The potentiometric response of the sensor is independent in the pH range 2.9–9.5. The advantages of sensor are low resistance, very fast response time (<10 s) with good selectivity. This sensor can be used up to 6 weeks without any divergences in potential response.  相似文献   

17.
The efficiency of a trinuclear and two binuclear manganese complexes in reconstituting electron transport and O(2) evolution activity in Mn-depleted Photosystem II preparations is analyzed. The trinuclear Mn-complex is more efficient than two binuclear Mn-complexes in restoring oxygen evolution, but it is less effective as an electron donor than binuclear Mn-complexes. It is inferred from our results that recovery of electron transport and O(2) evolution with polynuclear Mn-complexes is affected with different factors. Moreover, the trinuclear Mn-complex is extremely sensitive to the addition of CaCl(2). It is suggested that there is an interaction between Ca(2+) and carboxyl within the trinuclear Mn-complex during photoactivation and this interaction benefits the ligation of Mn atom to the apo-WOC and form an active WOC. Binuclear Mn(III)Mn(III) complex shows slightly higher efficiency than binuclear Mn(III)Mn(IV) complex in restoration of O(2) evolution activity. The efficiency of three Mn-complexes in the reconstitution of WOC is in an order: trinuclear Mn(3)(III)>binuclear Mn(III)Mn(III)>binuclear Mn(III)Mn(IV).  相似文献   

18.
Cu2+ selective PVC membrane electrode based on new Schiff base 2, 2'-[1,9 nonanediyl bis (nitriloethylidyne)]-bis-(1-naphthol) as a selective carrier was constructed. The electrode exhibited a linear potential response within the activity range of 1.0 x 10(-6) - 5.0 x 10(-3) moll(-1) with a Nernstian slope of 29 +/- 1 mV decade(-1) of Cu2+ activity and a limit of detection 8.0 x 10(-7) mol l(-1). The response time of the electrode was fast, 10 s, and stable potentials were obtained within the pH range of 3.5- 6.5. The potentiometric selectivity coefficients were evaluated using two solution method and revealed no important interferences except for Ag+ ion. The proposed electrode was applied as an indicator electrode to potentiometric titration of Cu2+ ions and determination of Cu2+ content in real samples such as black tea leaves and multivitamin capsule.  相似文献   

19.
Zhang ZR  Yu RQ 《Talanta》1994,41(2):327-333
Four macrocyclic polyether derivatives of o-phenanthroline were synthesized and used as neutral carriers for preparing poly(vinyl chloride) (PVC) membrane electrodes to sense primary amine species. The potentiometric response characteristics of the electrodes prepared were investigated. The electrode sensitive to benzyl amine as model analyte showed a linear response range of 8.0 x 10(-6)-0.1 mol/l with a detection limit of 8.9 x 10(-7) mol/l and a slope of 56.5 mV/decade. The linear potentiometric response of the mexiletine-sensitive electrode was 4.7 x 10(-6)-0.1 mol/l, and the detection limit was 5.0 x 10(-7)1 mol/l with a slope of 59.0 mV/decade. The transfer behavior of amines and ammonium ions through an organic phase was investigated by means of the bulk liquid membrane transport experiment. The effects of pH, counter anions and other factors on the transfer of the amine and ammonium species were studied. The mass transfer rates of the test species facilitated by macrocyclic polyether derivatives of o-phenanthroline were determined and the following sequence was found: benzyl amine > ethyl amine > tetramethyl ammonium > triethyl amine > diethyl amine > K(+) > ammonium > Na(+) > Ca(2+) > Mg(2+). This was exactly the potentiometric selectivity sequence of the membrane electrodes prepared by using these carriers. The mechanism of transfer of benzyl amine through a membrane phase induced by the carriers has been elucidated on the basis of experimental observations.  相似文献   

20.
长寿命高选择性液膜碘离子电极的研究   总被引:6,自引:0,他引:6  
合成了PVC-双硫腙-Hg(Ⅱ)载体.以该载体物质制备了高选择性碘离子电极,其选择性次序为:I-》ClO4->SCN->NO2-》Sal-~Br->NO3->Cl-.电极对碘离子的线性响应范围为1×10-3~5×10-7mol/L,检测下限为2×10-7mol/L,斜率为(59±1)mV/decade(16℃).并研究了电极的响应机理,表明系碘离子与载体中金属汞原子直接作用.将该电极应用于食盐中碘的测定,取得了满意的结果.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏