首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
There is considerable evidence that toxicity and physiological behavior of arsenic depends on its chemical forms. Arsenic speciation became therefore the subject of increasing interest in recent years. A sensitive method for the determination of arsenic species has been developed. The proposed procedure involves the use of high-performance liquid chromatography and inductively coupled plasma mass spectrometry (HPLC-ICP-MS). Six arsenic compounds were separated by anion-exchange chromatography with isocratic elution using tartaric acid as mobile phase with an elution order: arsenocholine, arsenobetaine, dimethylarsinic acid, methylarsonic acid, arsenous acid and arsenic acid. The chromatographic parameters affecting the separation of the arsenic species were optimized. Analytical characterization of the method has been realized with standard solutions. The detection limits for six arsenic compounds were from 0.04 to 0.6 g/L as As element. The repeatability (expressed by R.S.D) was better than 7% for all investigated compounds. The HPLC-ICP-MS system was successfully applied to the determination of arsenic compounds in environmental and biological samples in g/L level.  相似文献   

2.
采用阴(Hamilton PRP-X100柱)阳(Dionex Ionpac CS-10柱)离子交换色谱-电感耦合等离子体质谱联用技术,分别以pH 10.3的20 mmol/L NH4HCO3和pH 2.0的5 mmol/L吡啶溶液为流动相,建立了As(Ⅲ)、As(Ⅴ)、一甲基砷酸(MMA)、二甲基砷酸(DMA)、砷甜菜碱AsB、砷糖PO4、砷糖OH、砷糖SO3、砷糖SO4砷形态的分析方法。采用微波消解法和超声溶剂提取法对不同海域10种紫菜和海带产品进行前处理,对As含量及其化学形态进行分析。实验表明,样品总砷的质量分数为1.7~38.7 mg/kg,样品萃取物中,As糖PO4和As糖OH为As的主要形态,其含量分别占可提取As的6.5%~67.7%和12.9%~86.2%,海带样品萃取物中还有As糖SO3和DMA被检测,其含量分别占可提取As的13.0%~52.1%和5.9%~17.4%。在紫菜和海带海藻类产品中,含As的化合物主要是毒性较低的有机砷。  相似文献   

3.
A bioavailability study based on an in vitro dialyzability approach has been applied to assess the bio-available fractions of iodine and bromine species from edible seaweed. Iodide, iodate, 3-iodo-tyrosine (MIT), 3,5-diiodo-tyrosine (DIT), bromide and bromate were separated by anion exchange chromatography under a gradient elution mode (175 mM ammonium nitrate plus 15% (v/v) methanol, pH 3.8, as a mobile phase, and flow rates within the 0.5–1.5 mL min−1 range). Inductively coupled plasma-mass spectrometry (ICP-MS) was used as a selective detector for iodine (127I) and bromine (79Br). Low dialyzability ratios (within the 2.0–18% range) were found for iodine species; whereas, moderate dialyzability percentages (from 9.0 to 40%) were obtained for bromine species. Iodide and bromide were the major species found in the dialyzates from seaweed, although MIT and bromate were also found in the dialyzates from most of the seaweed samples analysed. However, DIT was only found in dialyzates from Wakame, Kombu, and NIES 09 (Sargasso) certified reference material; whereas, iodate was not found in any dialyzate. Iodine dialyzability was found to be dependent on the protein content (negative correlation), and on the carbohydrate and dietary fibre levels (positive correlation). However, bromine dialyzability was only dependent on the protein amount in seaweed (negative correlation).  相似文献   

4.
A method based on ion chromatography (IC) and inductively coupled plasma MS (ICP-MS) was developed for the speciation of arsenic in water and soil extracts. An anion-exchange column (G3154A/101) was used to separate As(III), As(V), dimethylarsinic acid (DMA), and monomethylarsonic acid (MMA) with excellent resolution. Various ammonium salts, including NH4H2PO4, (NH4)2HPO4, (NH4)2CO3, and NH4HCO3, were examined as eluents to reduce matrix interference from chloride and to solve clogging problems. The best arsenic speciation was obtained within 9 min with excellent resolution and without interference from high chloride concentrations using an eluent containing 7.5 mM (NH4)2HPO4 at pH 7.9. The detection limits for the target arsenic species ranged from 0.1 to 0.4 microg/L with direct injection of sample without matrix elimination. The proposed method was effectively demonstrated by determining arsenic species in contaminated waters and soils of Bangladesh.  相似文献   

5.
Yeh CF  Jiang SJ 《Electrophoresis》2005,26(7-8):1615-1621
A capillary electrophoresis-inductively coupled plasma-mass spectrometric (CE-ICP-MS) method for the speciation of six arsenic compounds, namely arsenite [As(III)], arsenate [As(V)], monomethylarsonic acid, dimethylarsinic acid, arsenobetaine and arsenocholine is described. The separation has been achieved on a 70 cm length x 75 microm ID fused-silica capillary. The electrophoretic buffer used was 15 mM Tris (pH 9.0) containing 15 mM sodium dodecyl sulfate (SDS), while the applied voltage was set at +22 kV. The arsenic species in biological tissues were extracted into 80% v/v methanol-water mixture, put in a closed centrifuge tube and kept in a water bath, using microwaves at 80 degrees C for 3 min. The extraction efficiencies of individual arsenic species added to the sample at 0.5 microg As/g level were between 96% and 107%, except for As(III), for which it was 89% and 77% for oyster and fish samples, respectively. The detection limits of the species studied were in the range 0.3-0.5 ng As/mL. The procedure has been applied for the speciation analysis of two reference materials, namely dogfish muscle tissue (NRCC DORM-2) and oyster tissue (NIST SRM 1566a), and two real-world samples.  相似文献   

6.
Selenium is an essential nutrient for humans; selenium compounds catalyze intermediate metabolism reactions and inhibit the toxic effects of heavy metals such as arsenic, cadmium and mercury. Some extracts of selenium-enriched biological materials show cancer preventive effects, tentatively attributable to the biological functions of selenoamino acids. An improved ion pair chromatographic method with methodological enhancements for the separation, qualitative and quantitative determination of non-volatile selenium compounds extracted from different samples has been developed using ICP-MS as an element-selective detector. Separation power early in the chromatogram was increased to baseline separation in the standard mixture as a result of decreasing spray chamber size from 97 to 14 ml, and increasing trifluoracetic acid (TFA) concentration in the mobile phase from 0.1 to 0.6%. The former pH was restored by the addition of ammonia to the mobile phase, which also served to increase the column recovery of inorganic anions. Calibration curves for different selenoamino acids showed statistically different behavior. Biological sample extracts were characterized using HPLC-ICP-MS. Mass spectral behavior of selenoamino acids, using electrospray and ion trap technology with direct infusion and liquid chromatographic sample introduction, is also reported.  相似文献   

7.
建立了稻米中砷酸根[As(Ⅴ)]、亚砷酸根[As(Ⅲ)]、砷甜菜碱(AsB)、一甲基砷(MMA)和二甲基砷(DMA)的液相色谱-电感耦合等离子体质谱(LC-ICP-MS)检测方法。以0.3 mol/L硝酸水溶液为提取试剂,样品在石墨消解仪中于95 ℃消解1.5 h,上清液供LC-ICP-MS分析。5种砷形态采用Dionex IonPac AS19阴离子交换柱(250 mm×4 mm)分离,经ICP-MS检测。比较了4种提取液对稻米中5种砷形态的提取效率,并对提取溶剂的浓度、提取温度和提取时间等条件进行了优化。通过加标回收试验结合测定标准物质考察了方法准确度及精密度,在2个加标水平上各形态的回收率为89.6%~99.5%,RSD(n=5)不大于3.6%,大米标准物质中各形态之和的测定结果与其标准值吻合,5种砷形态的线性范围AsB和DMA为0.05~200 μg/L,As(Ⅲ)和MMA为0.10~400 μg/L,As(V)为0.15~600 μg/L,方法检出限为0.15~0.45 μg/kg。结果表明,本方法简单、灵敏、耐用,可用于稻米中5种砷形态的准确定量和风险评估。  相似文献   

8.
A method was validated for the direct determination of As(III) and As(V) in water samples by ion chromatography/inductively coupled plasma-mass spectrometry. Sample preservation required only dilution with a mobile phase containing a sufficient amount of ethylenediaminetetraacetic acid and acetic acid. Analyses of 6 certified reference materials (CRMs) of various water matrixes, including seawater, demonstrated good method accuracy. The matrixes included 2 natural water samples [National Institute of Standards and Technology Standard Reference Material (NIST SRM) 1643e and NIST SRM 1640], 1 fortified standard solution (TMDA-64), 1 fortified water sample (TM-DWS), and 2 seawater samples (CASS-4 and NASS-5). The sum of As(III) and As(V) in each CRM agreed with the respective certified value for the total amount of As within its stated uncertainty. Quantitative recoveries (96.7-102.1%) were obtained. Satisfactory results were achieved for intraday repeatability [relative standard deviation (RSD = 0.3-5.1%] and interday precision (RSD = 0.7-4.1%). In the study of fortified blanks and fortified CRMs, quantitative recoveries of As(III) and As(V) (92.5-102.6%) were obtained. Interconversion of As(III) and As(V) was not observed under the conditions of sample preservation. International comparability of analytical results was demonstrated by the analysis of 2 interlaboratory proficiency test samples, NY7011 and NY8511, from the New York State Department of Health.  相似文献   

9.
Five arsenic species, trimethylarsine oxide, dimethylarsenic acid, monomethylarsonic acid, arsenobetaine and sodium arsenite, in urine were analysed by inductively coupled plasma mass spectrometry with ion chromatography (IC ICP MS). Since the toxicities of different arsenic compounds are different, speciation of arsenic compounds is very important in the investigation of metabolisms. In this paper, we applied ion chromatography (IC) as a separation device and inductively coupled plasma mass spectrometry (ICP MS) as a detection device. For separation of the five arsenic compounds, an anion-exchange column and, as mobile phase, tartaric acid were used. The eluent from the IC column was introduced directly into the nebulizer of the ICP MS and analysed at 75 amu. Detection limits were from 4 to 9 pg as arsenic.  相似文献   

10.
In order to measure trace 236U and 236U/238U in environmental samples with a high matrix effect, a novel and simple method was developed that makes the digestion and purification procedures compatible with advanced triple-quadrupole inductively coupled plasma-mass spectrometry. A total dissolution of sample with HF + HNO3 + HClO4 was followed by chromatographic separation with a single resin column containing normal type DGA resin (N,N,N′,N’-tetra-n-octyldiglycolamide) as the extractant system. The analytical accuracy and precision of 236U/238U ratios, measured as 236U16O+/238U16O+, were examined by using the reference materials IAEA-135, IAEA-385, IAEA-447, and JSAC 0471. The low method detection limit (3.50 × 10−6 Bq kg−1) makes it possible to perform routine monitoring of environmental 236U due to global fallout combined with the Fukushima Daiichi Nuclear Power Plant accident fallout (>10−5 Bq kg−1). Finally, the developed method was successfully applied to measure 236U/238U ratios and 236U activities in soil samples contaminated by the accident. The low 236U/238U atom ratios ((1.50–13.5) × 10−8) and 236U activities ((2.25–14.1) × 10−2 mBq kg−1) indicate 236U contamination was mainly derived from global fallout in the examined samples.  相似文献   

11.
Anion-exchange chromatography (Hamilton, PRP-X100) with inductively coupled plasma mass spectrometry (ICP-MS) is commonly used for the speciation of arsenic in environmental and biological samples. However, retentions for As species are frequently different because of the use of widely different mobile phases. In addition, chloride in matrices interferes with arsenic determination. In this study, we systematically investigated various mobile phases based on ammonium salts affecting arsenic retention to eliminate chloride interference chromatographically. Hence, various mobile phases based on ammonium salts, including NH4H2PO4, NH4HPO4, NH4Ac, NH4HCO3 and NH4NO3, were examined for reasonable resolution and to separate chloride from arsenic species. The best result was obtained with a mobile phase containing 30 mM NH4H2PO4 at pH 5.6, where the separation of arsenic species, including arsenite [As(III)], arsenate [As(V)], dimethylarsinic acid (DMA) and monomethylarsonic acid (MMA)], was achieved within 9 minutes with reasonable resolution and free of chloride interference at its high level (500 mg L− 1). The detection limits for the arsenic species were in the range of 0.1-0.3 μg L− 1 with a direct injection of sample without removing matrix. Finally, the proposed method was used for the determination of arsenic species in contaminated soil and plant tissues.  相似文献   

12.
Jitmanee K  Oshima M  Motomizu S 《Talanta》2005,66(3):529-533
A novel and simple flow-based method was developed for the simultaneous determination of As(III) and As(V) in freshwater samples. Two miniature columns with a solid phase anion exchange resin, placed on two 6-way valves were utilized for the solid-phase collection/concentration of arsenic(III) and arsenic(V), respectively. As(III) could be retained on the column after its oxidation to As(V) species with an oxidizing agent. The collected analytes were then sequentially eluted by 2 M nitric acid and introduced into ICP-AES. Potassium permanganate was examined as potential oxidizing agent for conversion of As(III) to As(V). The standard deviation of the analytical signals (peak height) for the replicate analysis (n = 5) of 0.5 μg l−1 solution were 3 and 5% for As(III) and As(V), respectively. The limit of detection (3σ) for both As(III) and As(V) were 0.1 μg l−1. The proposed system produced satisfactory results on the application to the direct analysis of inorganic arsenic species in freshwater samples.  相似文献   

13.
电感耦合等离子体质谱法测定地球化学样品中镉   总被引:2,自引:0,他引:2  
采用HF-HClO4-HNO3-H2SO4分解样品,王水提取,选用4个国家一级标准物质制备成标准系列校准,ICP-MS法直接测定地球化学样品中的Cd。选择103Rh为内标,确定了仪器的最佳分析条件,研究了Zr,Sn对Cd的干扰,选择114Cd作为测定同位素,采用数学公式校正了Sn对Cd的同质异位素干扰,方法检测限(3s)为6.3×10-3μg/g,RSD(n=12)为3.9%~6.6%。经国家一级标准物质验证,测定值与标准值吻合较好。该方法适用于地球化学样品中的微量Cd的测定。  相似文献   

14.
Degueldre C  Favarger PY  Rossé R  Wold S 《Talanta》2006,68(3):623-628
Uranium single particle analysis has been performed by inductively coupled plasma-mass spectrometry (ICP-MS) and the performances are compared with that provided by scanning electron microsopy and single particle counting. The transient signal induced by the flash of ions due to the ionisation of an uranium colloidal particle in the plasma torch can be detected and measured for selected uranium ion masses (238U+, 235U+ or 254[238U16O]+) by the mass spectrometer. The signals recorded via time scanning are analysed as a function of particle size or fraction of the studied element or isotope in the colloid phase. The frequency of the flashes is directly proportional to the concentration of particles in the colloidal suspension. The feasibility tests were performed on uranium dioxide particles. The study also describes the experimental conditions and the choice of mass to detect uranium colloids in a single particle analysis mode.  相似文献   

15.
Selenium exists in several oxidation states and a variety of inorganic and organic compounds, and the chemistry of selenium is complex in both the environment and living systems. Selenium is an essential element at trace levels and toxic at greater levels. Interest in speciation analysis for selenium has grown rapidly in this last decade, especially in the use of chromatographic separation coupled with inductively coupled plasma-mass spectrometry (ICP-MS). Complete characterization of selenium compounds is necessary to understand selenium's significance in metabolic processes, clinical chemistry, biology, toxicology, nutrition and the environment. This review describes some of the essential background of selenium, and more importantly, some of the currently used separation methodologies, both chromatographic and electrophoretic, with emphasis on applications of selenium speciation analysis using ICP-MS detection.  相似文献   

16.
Degueldre C  Favarger PY 《Talanta》2004,62(5):1051-1054
Thorium colloid analysis in water has been carried out by a single particle mode using inductively coupled plasma mass spectrometry (ICP-MS). The flash of ions due to the ionisation of a thorium colloidal particle in the plasma torch can be detected and measured in a time scan for 232Th+ or 248[ThO]+ according to the sensitivity required by the mass spectrometer. The peaks of the recorded intensity of the MS signal can be analysed as a function of the particle size or fraction of the studied element in the colloid phase. The frequency of the flashes is directly proportional to the concentration of particles in the colloidal suspension. After discussing Th colloid detection, on the basis of the intensity of the ion flashes generated in the plasma torch, tests were performed on thorium dioxide colloidal particles. This feasibility study also describes the experimental conditions and the limitation of the plasma design to detect thorium colloids in a single particle analysis mode down to about 10 fg.  相似文献   

17.
The effects of varying the sampler-skimmer spacing in an inductively coupled plasma-mass spectrometer are illustrated. The signals for a number of species were monitored including background ions (ArN+, ArO+, ArOH+, Ar2+, Ar2H+), background continuum, analyte ions (Cu+, Ce+, La+), analyte oxide ions (CeO+, LaO+), and matrix induced ions (ArNa+). As the sampler-skimmer spacing is increased over that normally used, the signal for some species decreases in intensity while the signal for others increases in intensity. There is a wide range of differential behavior and in some cases the signal changes are quite dramatic.

In addition to presenting results for an Ar plasma, measurements are also presented for a N2-Ar mixed gas plasma. For some species, the signal changes observed when the sampler-skimmer spacing is increased are quite different with the N2-Ar mixed gas plasma than with the Ar plasma and are, in some cases, opposite to signal changes observed with the Ar plasma. It appears that a larger sampler-skimmer spacing is more appropriate for a N2 mixed gas plasma than the spacing normally used for a pure Ar plasma. Finally the effect of sampler-skimmer spacing on matrix effects is presented and it appears that matrix effects are not induced in the zone between the sampler and the skimmer.  相似文献   


18.
采用高效液相色谱( HPLC)和电感耦合等离子体质谱(ICP-MS)联用技术测定了海洋产品中的无机砷.动物性和植物性海洋产品试样经过10% H3PO溶液(V/V)提取,阴离子交换色谱分离,ICP-MS测定其中As(Ⅲ)和As(Ⅴ)的含量.实验结果表明As(Ⅲ)和As(Ⅴ)的检出限分别为5.0和8.0 μg/kg,线性范...  相似文献   

19.
A simple and sensitive method for the speciation of vanadium(III), (IV), and (V) was developed by using high performance liquid chromatography and inductively coupled plasma mass spectrometry (HPLC-ICPMS). The EDTA-complexed vanadium species were separated on a strong anion exchange column with an eluent containing 2 mM EDTA, 3% acetonitrile, and 80 mM ammonium bicarbonate at pH 6. Each analysis was complete in 5 min. The detection limits were 0.6, 0.7 and 1.0 μg L−1 for V(III), V(IV), and V(V), respectively. The method was applied to coke pore water samples from an oilsand processing/upgrading site in Fort McMurray, Alberta, Canada and to Shewanella putrefaciens CN32 bacterial cultures incubated with V(V). In the coke pore water samples, V(IV) and V(V) were found to be the major species. For the first time, V(III) was detected in the bacterial cultures incubated with V(V).  相似文献   

20.
For selenium speciation analysis, the hyphenation of chromatographic separation with element-specific detection has proved a useful technique. A powerful separation system, which is capable of resolving several biologically and environmentally important selenium compounds in a single column, is greatly needed. However, that has been difficult to achieve. In this paper eight selenium compounds, namely, selenite [Se(IV)], selenate [Se(VI)], selenocystine (SeCys), selenourea (SeUr), selenomethionine (SeMet), selenoethionine (SeEt), selenocystamine (SeCM) and trimethylselenonium ion (TMSe+), were separated by using mixed ion-pair reagents containing 2.5 mM sodium 1-butanesulfonate and 8 mM tetramethylammonium hydroxide as a mobile phase. The separation of these anionic, cationic and neutral organic selenium compounds on a LiChrosorb RP18 reversed-phase column took only 18 min at a flow-rate of 1.0 ml/min with isocratic elution, and baseline separation among the six organic Se compounds was achieved. Inductively coupled plasma mass spectrometry (ICP-MS) was employed as element-specific detection. A comparison of ICP-MS signal intensity obtained with a Barbington-type nebulizer and with an ultrasonic nebulizer (USN) was made. Different signal enhancement factors were observed for the various selenium compounds when a USN was used. The speciation technique was successfully applied to the study on chemical forms of selenium in a selenium nutritional supplement. Selenomethionine was found to be the predominant constituent of selenium in the supplement.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号