首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
A coulometric procedure has been developed by which 18 to 240 μg quantities of bromate may be determined to within 0.3 μg. The bromate is allowed to react with bromide in an acid solution and electrolytically generated cuprous copper is used for the titration. A dual platinum electrode indicator system is used in an amperometric end-point procedure  相似文献   

3.
An apparatus is described for the automatic titration of acids by the constant current coulometric technique. The generator electrodes comprise a platinum cathode and a silver/silver bromide anode. The increase in pH resulting from the reduction of hydrogen ion at the cathode is indicated by a glass electrode, in conjunction with a Beckman Automatic Titrator which automatically monitors the titration and interrupts the generating current when the equivalence point pH is reached. Quantities of hydrochloric acid in the neighborhood of 0.12 millimole in 50 ml were titrated with a mean error of -0.07% and an average deviation from the mean of ±0.15%. The technique is applicable to any strong or weak acid, and to acid mixtures, provided that no substance is present which is either reducible at the platinum cathode or reactive in any way at the silver anode.  相似文献   

4.
Głab S  Hulanicki A 《Talanta》1981,28(3):183-186
A procedure is described for the evaluation of autoprotolysis constants in which a strong acid is titrated with coulometrically generated strong base. A two-compartment cell is used, and the acid may be added as such to the solvent under study, or generated in situ in the cell. When a silver auxiliary electrode can be used, as with solutions containing bromide ion, a single-compartment cell may be used, which seems to give more accurate results because it avoids the errors caused by diffusion of solution through the diaphragm. The results for the constants obtained for ethylene glycol, for methanol and for water are in reasonable agreement with values in the literature.  相似文献   

5.
The catalytic cycle of cytochrome c oxidase has been simulated by means of quantum mechanical calculations. The experimental energetics of the catalytic cycle is nearly reproduced. The atomic structures of the intermediates are suggested. In particular, the structures of nonactive "resting" intermediates are proposed.  相似文献   

6.
Two different issues, important for the pumping mechanism of cyctochrome c oxidase, have been addressed in the present study. One of them concerns the nature of two key proton transfer transition states. A simple electrostatic model is used to suggest that the transition state (TS) for transfer to the pump-site should be positively charged, while the one for transfer to the binuclear center should be charge-neutral. The character of the former TS will guarantee that the protons will be pumped to the outside and not return to the inside, while the neutral character of the latter one will allow transfer with a sufficiently low barrier. In the simple electrostatic analysis, leading to this qualitative picture of the pumping process, the results from the kinetic experiments are strictly followed, but it is at least as important to follow the fundamental requirements for pumping. In this perspective, the uncertainties in the quantitative analysis should be rather unimportant for the emerging qualitative picture of the pumping mechanism. The second problem addressed concerns the purpose of the K-channel. It is argued that the reason for the presence of the K-channel could be that protons cannot pass through the binuclear center at some stage of pumping. Barriers and water binding energies were computed using hybrid density functional theory (DFT) to investigate this question.  相似文献   

7.
Application of coulometric titration to the determination of the protonation constants of acids and bases offers several advantages because of its simplicity, precision and accuracy. This procedure is rapid and requires only one calibration solution of strong acid in the same solvent and at the same ionic strength as the solution of acid (or base) being investigated. The procedure seems to be especially advantageous in the case of non-aqueous or mixed solvents having amphiprotic character. The validity of the method has been checked with several substances in water, 95% ethanol and ethylene glycol.  相似文献   

8.
A series of iron porphyrins has been synthesized as models of cytochrome c oxidase; their activity as 4e catalysts in the reduction of dioxygen has been studied at pH 7. These compounds have been obtained by grafting very different residues onto the same iron complex, namely tripodal tetraamines, pickets, and straps, in order to change the environment of the metal center. In the case of porphyrins bearing a tripodal cap, the secondary amines have been alkylated with different substituents so as to modify the electronic environment of the distal pocket. Surprisingly, when the iron porphyrin is functionalized with four identical acrylamido pickets, the resulting complex exhibits biomimetic activity in that it catalyzes oxygen reduction with almost no production of hydrogen peroxide. The crystal structure of the redox-inactive zinc(II) analogue is reported; this shows how the metal influences the spatial arrangement of the four pickets through axial coordination and hydrogen bonding. Even a bis-strapped iron porphyrin, for which no dimerization or self-aggregation can occur at the electrode surface, acts as a 4e catalyst for O2 reduction. It is thus demonstrated that at pH close to physiological values, the iron porphyrin is an intrinsically efficient catalyst for the reduction of oxygen to water.  相似文献   

9.
The complex formed between cytochrome c oxidase from Paracoccus denitrificans and its electron-transfer partner cytochrome c has been studied by multi-frequency pulse electron paramagnetic resonance spectroscopy. The dipolar relaxation of a fast-relaxing paramagnetic center induced on a more slowly relaxing center can be used to measure their distance in the range of 1-4 nm. This method has been used here for the first time to study transient protein-protein complex formation, employing soluble fragments for both interacting species. We observed significantly enhanced transversal relaxation of the CuA center in cytochrome c oxidase due to the fast-relaxing iron of cytochrome c upon complex formation. The possibility to measure cytochrome c oxidase in the presence and absence of cytochrome c permitted us to separate the dipolar relaxation from other relaxation contributions. This allowed a quantitative simulation and interpretation of the relaxation data. The specific temperature dependence of the dipolar relaxation together with the high orientational selectivity achieved at high magnetic field values may provide detailed information on distance and relative orientation of the two proteins with respect to each other in the complex. Our experimental results cannot be explained by any single well-defined structure of the complex of cytochrome c oxidase with cytochrome c, but rather suggest that a broad distribution in distances and relative orientations between the two proteins exist within this complex.  相似文献   

10.
Kinberger B  Edholm LE  Nilsson O  Smith BE 《Talanta》1975,22(12):979-987
A general method for coulometric titration of alkylphenols with anodically generated bromine is described. The reaction is carried out in a water-acetic acid medium and the reactivity is governed by varying the water content and the concentration of bromide ion and by the addition of pyridine. In that way all types of alkylphenols can be titrated quantitatively. For phenols containing more than one free ortho and para position, the titration can also be carried out either to the monobromination stage or to the full bromination stage. The mean relative error is ± 1·2% for monobromination and ±1·5% for full bromination. A method for rapid determination of the number of free ortho and para positions in alkylphenols by using two coulometric titrations is also described.  相似文献   

11.
Truedsson LA  Smith BE 《Talanta》1979,26(6):487-491
A general method is described for the coulometric titration of alkylanilines with anodically generated bromine. The reaction is carried out in water-acetic acid medium and the reactivity is governed by varying the water content and the concentration of bromide ion and by the addition of pyridine. In this way most types of alkylanilines can be titrated quantitatively. Unlike the case for alkylphenols, the bromine consumption is not always higher in the pyridine-containing media than in the pyridine-free. The bromine consumption is also more dependent on the bromide content of the medium than it is for alkylphenols. The mean relative error, for the best medium for each compound, is +/-0.9% for primary alkylanilines, +/-0.9% for secondary and +/-1.2% for tertiary.  相似文献   

12.
The coulometric titration of 20–200 μeq of acids and bases in DMSO media is described. In the titration of bases, the electro-oxidation of hydrogen at a platinized platinum electrode is used as the source of protons. The conditions for 100 % current efficiency at this electrode are low current density to avoid passivity and regular treatment of the electrode with potassium dichromate—sulfuric acid to remove a poisoning sulfide layer. The accuracy of the titrations is better than ±1 %. Very weak acids like phenols (pKa (DMSO) ≈16) can be titrated successfully. Tris(hydroxymethyl)aminomethane is the weakest base titrated.  相似文献   

13.
The bromine number, the number of grams of bromine which react with 100 grams of a substance under given conditions, is a widely used parameter in the chemical and petroleum industries. A method of performing the bromine number determination by coulometric flow-injection titration, using both sequential injection with sinusoidal flow and single zone techniques, is described. Titrations of olefins, known interfering compounds, and petroleum distillates were performed and compared with the results of conventional bromine number titrations. Analyses yielded a relative standard deviation of 2%. Results compared favorably with those obtained by the conventional method for both pure (97%) olefins and petroleum distillates. The method was found to be insensitive to interference from nitrogen compounds. The CFIT technique combines the advantages of coulometric titrations: controlled generation of reagent, avoidance of reagent standardization requirements and reagent storage and stability problems; with the advantages of FIA: small volume requirements which reduce cost and waste, controllable dilution through flow programming, toxic materials contained within a closed environment, and the capability of being automated.  相似文献   

14.
Cytochrome c oxidase (CcO) is the terminal transmembrane enzyme of the respiratory electron transport chain in aerobic cells. It catalyzes the reduction of oxygen to water and utilizes the free energy of the reduction reaction for proton pumping, a process which results in a membrane electrochemical proton gradient. Although the structure of the enzyme has been solved for several organisms, the molecular mechanism of proton pumping and proton exit pathways remain unknown. In our previous work, the continuum electrostatic calculations were employed to evaluate the electrostatic potential, energies, and protonation state of bovine cytochrome c oxidase for different redox states of the enzyme. A possible mechanism of oxygen reduction and proton pumping via His291 was proposed. In this paper, using electrostatic calculations, we examine the proton exit pathways in the enzyme. By monitoring the changes of the protonation states, proton affinities, and energies of electrostatic interactions between the titratable groups in different redox states of CcO, we identified the clusters of strongly interacting residues. Using these data, we detected four possible proton exit points on the periplasmic side of the membrane (Lys171B/Asp173B, His24B/Asp25B, Asp51, and Asp300). We then were able to trace the proton exit pathways and to evaluate the energy profiles along the paths. On the basis of energetic considerations and the conservation of the residues in a protein sequence, the most likely exit pathway is one via the Lys171B/Asp173B site. The obtained results are fully consistent with our His291 model of proton pumping, and provide a rationale for the absence of proton leaking in CcO between the pumping strokes.  相似文献   

15.
A new method for the determination of 2-thiobarbituric acid, using its reaction with iodine in an alkaline medium is presented. In the volumetric titration with potentiometric end-point detection, the determinability range is 10-400 micromol (1.4-58 mg). In coulometric titration using the biamperometric end-point detection, 0.1-20 micromol (1.4 x 10(-2)-2.9 mg) of 2-thiobarbituric acid was successfully determined.  相似文献   

16.
Two methods are described for the purification of cytochrome c oxidase from Triton X-100 extracts of the periplasma membrane of Paracoccus denitrificans. The first is a large-scale procedure for the preparation of 100-250 nmol of cytochrome c oxidase (10-20 mg) in 1 week. The second is a rapid procedure for isolating up to 25 nmol in 2-3 days. Owing to the high yields given by fast protein liquid chromatography (FPLC) on Mono Q columns, the overall yield is about 20%, whereas the yield in many other previously published procedures does not exceed 10%. The use of FPLC on Mono Q also offers a considerable saving of time.  相似文献   

17.
Thermodynamic study has been made of lithium-vanadium bronzes β-LixV2O5?y in reversible cells with a lithium-conducting solid electrolyte using coulometric titration. The linear dependence of ΔGLi in the bronze on parameters x and T was found. It is concluded that the dependence of ΔGLi on the PO2 value is weak. The limits of the homogeneity region of β-LixV2O5?y have been more clearly defined.  相似文献   

18.
A method is described for the coulometric titration of acids and bases in the solvent m-cresol. The method is suitable for bases with pKa values greater than 11 in m-cresol, or for acids with pKa values below 13 in m-cresol. Amounts of 5–50 μeq of acid or base can be determined with a relative accuracy of ±1%.  相似文献   

19.
20.
Tanaka T  Marinenko G  Koch WF 《Talanta》1985,32(7):525-530
An experimental study of the current efficiency in the coulometric generation of Ti(III), as a function of electrolyte composition, current density and electrode material, has been performed. The cathodes investigated include platinum, mercury and graphite. The first two are suitable for high-precision determination of uranium. The graphite surface is readily poisoned, rendering it useless for high-accuracy work. The use of mercury requires thorough removal of chloride from the system. The precision and error obtained are comparable for both the mercury and platinum cathodes, and are of the order of 50 ppm.  相似文献   