首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
2.
The carrier ampholytes-based (CA-based) isoelectric focusing (IEF) experiment evolved from Svensson's closed system IEF (constant spatial current density, absence of convective mixing, counter-balancing electrophoretic and diffusive fluxes yielding a steady state pH gradient) to the contemporary open system IEF (absence of convective mixing, large cross-sectional area electrode vessels, lack of counter-balancing electrophoretic- and diffusive fluxes leading to transient pH gradients). Open system IEF currently is described by a two-stage model: In the first stage, a rapid IEF process forms the pH gradient which, in the second stage, is slowly degraded by isotachophoretic processes that move the most acidic and most basic CAs into the electrode vessels. An analysis of the effective mobilities and the effective mobility to conductivity ratios of the anolyte, catholyte, and the CAs indicates that in open system IEF experiments a single process, transient bidirectional isotachophoresis (tbdITP) operates from the moment current is turned on until it is turned off. In tbdITP, the anolyte and catholyte provide the leading ions and the pI 7 CA or the reactive boundary of the counter-migrating H3O+ and OH ions serves as the shared terminator. The outcome of the tbdITP process is determined by the ionic mobilities, pKa values, and loaded amounts of all ionic and ionizable components: It is constrained by both the transmitted amount of charge and the migration space available for the leading ions. tbdITP and the resulting pH gradient can never reach steady state with respect to the spatial coordinate of the separation channel.  相似文献   

3.
Huang T  Pawliszyn J 《Electrophoresis》2002,23(20):3504-3510
A simple microfabrication technique for the preparation of a tapered microchannel for thermally generated pH gradient isoelectric focusing (IEF) has been demonstrated. The tapered channel was cut into a plastic sheet (thickness was 120 microm), and the channel was closed by sandwiching the plastic sheet between two glass microscope slides. The length of the microchannel was 5 cm. The width of the separation channel was 0.4 mm at the narrow end and 4 mm at the wide end. The channel was coated with polyacrylamide to prevent electroosmotic flow (EOF) during focusing. Two electrolyte vials were mounted on top of each end of the channel with the wide end of the channel connected to the cathodic vial and the narrow to the anodic vial. The feasibility of the thermally generated pH gradient in a tapered channel was demonstrated. Important parameters that determined the feasibility of using a thermally generated pH gradient in a tapered channel were analyzed. Parameters to be optimized were control of EOF and hydrodynamic flow, selection of power supply mode and prevention of local overheating and air bubble formation. Tris-HCl buffer, which has a high pK(a) dependence with temperature, was used both to dissolve proteins and as the electrolyte. The thermally generated pH gradient separation of proteins was tested by focusing dog, cat and human hemoglobins with a whole column detection capillary IEF (CIEF) system.  相似文献   

4.
A divergent-flow isoelectric focusing (DF IEF) technique has been applied for the separation and preparative analysis of peptides. The parameters of the developed DF IEF device such as dimension and shape of the separation bed, selection of nonwoven material of the channel, and separation conditions were optimized. The DF IEF device was tested by the separation of a peptide mixture originating from the tryptic digestion of BSA, cytochrome c, and myoglobin. The pH gradient of DF IEF was created by the autofocusing of tryptic peptides themselves without any addition of carrier ampholytes. The focusing process was monitored visually using colored pI markers, and the obtained fractions were analyzed by RP-HPLC and ESI/TOF-MS. DF IEF operating in the autofocusing mode provides an efficient preseparation of peptides, which is comparable with a commercially available MicroRotofor multicompartment electrolyzer and significantly improves sequence coverage of analyzed proteins. The potential of the DF IEF device as an efficient tool for the preparative scale separations was demonstrated by the isolation of caseinomacropeptide (CMP) from a crude whey solution.  相似文献   

5.
Stastná M  Slais K 《Electrophoresis》2005,26(18):3586-3591
Two-dimensional gel isoelectric focusing (2-D gel IEF) is presented as the combination of the same separation method used consecutively in two directions of the same gel. In this new method, after completion of IEF process in the first dimension the gel was cut into the separate strips, each containing selected analytes together with the appropriate part of the original broad pH gradient, and the strips were rotated by 90 degrees (with regard to the first IEF) and left to diffuse overnight. After diffusion the strips were subjected to the second IEF. During the second IEF, the corresponding narrow part of pH gradient in each strip was restored again, however, now along the strip. The progress of the separation process can be monitored visually by using colored low-molecular-weight isoelectric point (pI) markers loaded into the gel simultaneously with proteins. The unique properties of IEF, focusing and resolution power were enhanced by using the same technique twice. Two forms of beta-lactoglobulin (pI values 5.14 and 5.31, respectively) non-separated in the first IEF were successfully separated in the second dimension at relatively low voltage (330 V) with the resolution power comparable to the high-resolution gels requiring the high voltage during the run and long separation time. Glucose oxidase loaded as diluted solution into ten positions across the gel was finally focused into a single band during 2-D gel IEF. Since the first and second IEF are carried out on the same gel, no losses and contamination of analyte occur. The suggested method can be used for separation/fractionation of complex biological mixtures, similarly as other multidimensional separation techniques applied in proteomics, and can be followed by further processing, e.g., mass spectrometry analysis. The focusing properties of IEF could be useful especially in separation of mixtures, where components are at low concentration levels.  相似文献   

6.
Das C  Zhang J  Denslow ND  Fan ZH 《Lab on a chip》2007,7(12):1806-1812
Two-dimensional (2D) protein separation is achieved in a plastic microfluidic device by integrating isoelectric focusing (IEF) with multi-channel polyacrylamide gel electrophoresis (PAGE). IEF (the first dimension) is carried out in a 15 mm-long channel while PAGE (the second dimension) is in 29 parallel channels of 65 mm length that are orthogonal to the IEF channel. An array of microfluidic pseudo-valves is created for introducing different separation media, without cross-contamination, in both dimensions; it also allows transfer of proteins from the first to the second dimension. Fabrication of pseudo-valves is achieved by photo-initiated, in situ gel polymerization; acrylamide and methylenebisacrylamide monomers are polymerized only in the PAGE channels whereas polymerization does not take place in the IEF channel where a mask is placed to block the UV light. IEF separation medium, carrier ampholytes, can then be introduced into the IEF channel. The presence of gel pseudo-valves does not affect the performance of IEF or PAGE when they are investigated separately. Detection in the device is achieved by using a laser induced fluorescence imaging system. Four fluorescently-labeled proteins with either similar pI values or close molecular weight are well separated, demonstrating the potential of the 2D electrophoresis device. The total separation time is less than 10 minutes for IEF and PAGE, an improvement of 2 orders of magnitude over the conventional 2D slab gel electrophoresis.  相似文献   

7.
This paper describes the development of a technique amenable to the separation of proteins on a microchip by isoelectric focusing (IEF) with entire channel scanning laser-induced fluorescence detection using acousto-optical deflection (AOD). The ability to use AOD to scan the portions of or the entire length of an IEF separation channel allows for high-speed analysis since the mobilization step is circumvented with this technique. Employing no moving parts eliminates mechanical noise and, not only is there no loss of resolution, AOD scanning can potentially increase resolution. The ability of AOD to provide ultra-fast scanning rates (kHz timescale) allows for real-time imaging of the focusing process. This is demonstrated with the separation of naturally fluorescent proteins using entire channel (total scanning range of 2.4 cm) AOD-mediated scanning laser-induced fluorescence detection.  相似文献   

8.
A novel microfabricated device for isoelectric focusing (IEF) incorporating an optimized electrospray ionization (ESI) tip was constructed on polycarbonate plates using laser micromachining. The IEF microchip incorporated a separation channel (50 micro x 30 micro x 16 cm), three fluid connectors, and two buffer reservoirs. Electrical potentials used for IEF focusing and electrospray were applied through platinum electrodes placed in the buffer reservoirs, which were isolated from the separation channel by porous membranes. Direct ESI-mass spectrometry (MS) using electrosprays produced directly from a sharp emitter "tip" on the microchip was evaluated. The results indicated that this design can produce a stable electrospray and that performance was further improved and made more flexible with the assistance of a sheath gas and sheath liquid. Error analysis of the spectral data showed that the standard deviation in signal intensity for an analyte peak was less than approximately 5% over 3 h. The production of stable electrosprays directly from microchip IEF device represents a step towards easily fabricated microanalytical devices. Microchannel IEF separations of protein mixtures were demonstrated for uncoated polycarbonate microchips. Direct microchannel IEF-ESI-MS was demonstrated using the microfabricated chip with an ion-trap mass spectrometer for characterization of protein mixtures.  相似文献   

9.
Slais K 《Electrophoresis》2008,29(12):2451-2457
Continuous-flow isoelectric focusing (IEF) has the potential to be an important method in proteome analysis. The current devices do not fully use the advantages of IEF, because they do not utilize all its important features including changes in background conductivity during the focusing. A novel continuous-flow IEF method has been developed based on planar divergent flow and control of local electric field by conductivity of electrode electrolytes. A hydrophilized polypropylene nonwoven fabric was used for creation of flow and electric manifold, making the assembled device cheap, flexible and easy to set up and operate. By using the colored low-molecular-weight pI markers we demonstrated much higher speed of focusing in the new designed channel in comparison with a channel based on currently used rectangular geometry. The developed divergent-flow IEF combines the speed of micro flow channels with the separation efficiency and sample load capacity of preparative devices.  相似文献   

10.
Investigation of isoelectric focusing (IEF) kinetics has been performed to provide the theoretical basis for miniaturization of classical IEF in immobilized pH-gradients. Standard IEF demands colinearity of the electric field and pH-gradient directions (serial devices). It is shown that the IEF separation process based on a continuous, serial pH gradient is incompatible with miniaturization of separation devices. The new realization of the IEF device by a parallel IEF chip is suggested and analyzed. The main separation tool of the device is a dielectric membrane (chip) with conducting channels that are filled by Immobiline gels of varying pH. The membrane is held perpendicular to the applied electric field and proteins are collected (trapped) in the channels whose pH are equal to the pI of the proteins. The pH value of the surrounded aqueous solution is not equal to any channel's pH. The fast particle transport between different channels takes place due to convection in the aqueous solution. The new device geometry introduces two new spatial scales to be considered: the scale of transition region from a solution to the gel in a channel and a typical channel size. The corresponding time scales defining the IEF process kinetics are analyzed and scaling laws are obtained. It is shown both theoretically and experimentally that parallel IEF accelerates the fractionation of proteins by their pI down to several minutes and enables possible efficient sample collection and purification.  相似文献   

11.
For the first time, the application of a commercial Shimadzu microchip electrophoresis system MCE-2010 equipped with an imaging UV detector for isoelectric focusing (IEF) of therapeutic proteins is reported. By proper adjustment of the pH gradient, samples with pI values ranging from 2.85 to 10.3 can be focused to the imaged part of the separation channel. Three therapeutic proteins (hirudin, erythropoietin, and bevacizumab) have been successfully focused on the microchip, and the results have been compared to conventional capillary IEF in terms of peak profile, pI values, and reproducibility.  相似文献   

12.
Xu Z  Okabe N  Arai A  Hirokawa T 《Electrophoresis》2010,31(21):3558-3565
This paper reports the protein analysis by using microchip IEF carried on an automated chip system. We herein focused on two important topics of microchip IEF, the pH gradient and cathodic drift. The computer simulation clarified that the EOF could delay the establishment of pH gradient and move the carrier ampholytes (CAs) to cathode, which probably caused a cathodic drift to happen. After focusing, the peak positions of components in a calibration kit with broad pI were plotted against their pI values to know the actual pH gradient in a microchannel varying time. It was found that the formed pH gradient was stable, not decayed after readily steady state, and migrated to cathode at a rate of 10.0 μm/s that determined by the experimental conditions such as chip material, internal surface coating and field strength. The theoretical pH gradient was parallel with the actual pH gradient, which was demonstrated in two types of microchip with different channel lengths. No compression of pH gradient was observed when 2% w/v hydroxypropyl methyl cellulose was added in sample and electrolytes. The effect of CAs concentration on current and cathodic drift was also explored. With the current automatic chip system, the calculated peak capacity was 23–48, and the minimal pI difference was 0.20–0.42 for the used single channel microchip with the effective length of 40.5 mm. The LOD for the analysis of CA‐I and CA‐II was around 0.32 μg/mL by using normal imaged UV detection, the detected amount is ca. 0.07 ng.  相似文献   

13.
Colored, low molecular weight pI markers have been developed for isoelectric focusing (IEF) in acidic pH range. Their isoelectric points (pIs) were determined by direct measurement of the pH of the focused bands after completion of IEF on polyacrylamide gels. The practicable suitability of the proposed pI markers as pI standards for IEF was tested by applying gel IEF. The acidic pH gradient was created either by commercial synthetic carrier ampholytes or by mixture of simple buffers consisting of acids (non-ampholytes) and ampholytic buffers. By applying simple acids, it was possible to extend the acidic pH range beyond those achievable with commercial synthetic carrier ampholytes. By using an experimental arrangement without electrode electrolyte reservoirs with electrodes creating the fixed end of the gel, the strongly acidic pH gradient was stable even for prolonged focusing time.  相似文献   

14.
A two-dimensional capillary electrophoresis platform, combining isoelectric focusing (IEF) and capillary zone electrophoresis (CZE), was established on a microchip with the channel width and depth as 100 mum and 40 mum, respectively. With polyacrylamide as permanent coating, EOF in the microchannel, which could impair the separation, was decreased to 3.4x10(-9)m(2).V(-1).s(-1), about 1/10 of that obtained in the uncoated set-up. During the separation, peptides were first focused by IEF in the first dimensional channel, and then directly driven into the perpendicular channel by controlling the applied voltages, and separated by CZE. Effects of various experimental parameters, including the electric field strength, channel length, and injection frequency from the first to the second dimensional separation channel, were studied. Under optimized condition, the digests of BSA and proteins extracted from E. coli were separated, and a peak capacity of 540 was obtained, which was far greater than that obtained by each single dimensional separation. All these results showed the promise of multidimensional separation on a microchip for the high-throughput and high-resolution analysis of complex samples.  相似文献   

15.
The conductivity properties of natural pH gradient created by carrier ampholytes were studied during the process of isoelectric focusing (IEF). IEF was performed in capillaries (10-30 mm long) or in microchips with the same channel length. A 10-30x reduction of the conductivity of the separation medium was observed during the establishment of pH gradient. Results obtained using different IEF voltages indicate that there is a nonlinear relationship between the conductivity of an established pH gradient and the applied electric field. Our theoretical analysis using a simplified model generated values that reasonably agree with the experimental data. In addition, we found that above a certain electric field ( approximately 300 V/cm), resolution does not increase with the applied voltage as predicated; we observed band-broadening and gel breakdown. The approach presented in this work can be used for optimization of the IEF separation and judicious selection of IEF conditions.  相似文献   

16.
Low-molecular-mass fluorescent compounds excitable in the near UV region with suitable acidobasic and electrophoretic properties are suggested as isoelectric point (pI) markers for isoelectric focusing (IEF) with UV photometric and UV excited fluorometric detection. The experimental set-up of capillary IEF with UV excited fluorometric detection and properties of new UV-induced fluorescent pI markers are given. The pI values of 18 new pI markers determined independently of IEF methods range from 2.1 to 10.3. The examples of separation of new pI markers together with derivatized proteins by capillary IEF with photometric or fluorometric detection are presented.  相似文献   

17.
We have developed novel protein gel electrophoresis techniques, sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) and isoelectric focusing (IEF) in short microchannels (approximately millimeters) that take less than a minute. A photopatterning technique was used to cast in situ crosslinked polyacrylamide gel in a microchannel to perform SDS-PAGE. A fluorescent protein marker sample (Mr range of 20,000-200,000) was separated in less than 30 s in less than 2 mm of channel length. Crosslinked polyacrylamide gel, patterned in channels using UV light, provides higher sieving power and sample stacking effect, therefore yielding faster and higher-resolution separation in a chip. IEF of proteins was also achieved in a microchannel, and several proteins were focussed within tens of seconds in mm-length channels. As resolution in IEF is independent of separation distance, focusing in ultra-short channels results in not only faster separation but also more concentrated bands potentially allowing detection of low-concentration species.  相似文献   

18.
Sample preparation is often necessary to separate and concentrate various compounds prior to analysis of complex samples. In this regard, isoelectric focusing (IEF) is one of the best sample preparation methods. With this approach, however, carrier ampholytes have to be introduced into the samples, which may result in matrix interferences. In this paper, a simple ampholyte-free IEF free-flow electrophoresis design was developed for the separation of proteins. beta-Lactoglobulin, hemoglobin, myoglobin and cytochrome c were selected as model analytes. The experimental design took advantage of the electrolysis-driven production of H(+) and OH(-) ions that migrated from the anode and cathode, respectively, establishing a pH gradient spanning from 2.3 to 8.9. The separation chamber was filled with silanized glass beads as a support medium. Dialysis membranes were mounted at the two sides of the separation chamber (made of glass slides) and sealed with 2% agarose gel. The separated proteins drained from the outlets of the separation chamber and could be successfully collected into small glass tubes. The focusing process was visually observed and the separation was confirmed by capillary isoelectric focusing (cIEF) with pI markers.  相似文献   

19.
An improvement has been made to couple isoelectric focusing (IEF) sample injection and capillary zone electrophoresis in an untreated fused silica capillary. Electroosmotic flow is efficiently prevented by simply using a rubber block at the outlet end of the capillary during IEF sample injection. The experimental conditions that affect the concentration effect are discussed. A concentration enhancement factor of over 100-fold can be easily obtained for two model proteins: lysozyme and ribonuclease A.  相似文献   

20.
《Electrophoresis》2018,39(8):1040-1047
Isoelectric focusing (IEF) is a powerful separation method, useful for resolving subtle changes in the isoelectric point of unlabeled proteins. While microfluidic IEF has reduced the separation times from hours in traditional benchtop IEF to minutes, the enclosed devices hinder post‐separation access to the sample for downstream analysis. The two‐layer open IEF device presented here comprises a photopatterned hydrogel lid layer containing the chemistries required for IEF and a thin polyacrylamide bottom layer in which the analytes are separated. The open IEF device produces comparable minimum resolvable difference in isoelectric point and gradient stability to enclosed microfluidic devices while providing post‐separation sample access by simple removal of the lid layer. Further, using simulations, we determine that the material properties and the length of the separation lanes are the primary factors that affect the electric field magnitude in the separation region. Finally, we demonstrate self‐indexed photomasks for alignment‐free fabrication of multi‐domain hydrogels. We leverage this approach to generate arrayed pH gradients with a total of 80 concurrent separation lanes, which to our knowledge is the first demonstration of multiple IEF separations in series addressed by a single pair of electrodes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号