共查询到17条相似文献,搜索用时 62 毫秒
1.
湿法炼锑中常采用硫化钠作为从锑矿中提取锑硫化物的浸出剂。准确测定锑浸出液中的硫化钠浓度对掌握和完善湿法炼锑工艺、提高生产效率有重要作用。将亚甲基蓝分光光度法用于锑浸出液中硫化钠的测定,考察了波长选择、体系酸度、显色时间、基质干扰等条件,测评、优化了方法;将方法应用于锑浸出液中硫化钠的测定,方法检出限为0.002mg/L,测定结果相对标准偏差≤3%,加标回收率≥90%。方法能较理想地应用于锑浸出液中硫化钠的测定,丰富了锑浸出液中硫化钠的测定方法,也为相关研究提供了支持与参考。 相似文献
2.
3.
4.
5.
IO3--I--亚甲基蓝-阿拉伯胶-聚乙烯醇体系分光光度法测定微量碘 总被引:3,自引:0,他引:3
在pH 3.8苯二甲酸氢钾-盐酸介质中,有阿拉伯胶和聚乙烯醇存在下,IO-3氧化I-生成I-3,I-3再与亚甲基蓝形成离子缔合物,缔合物的最大吸收波长为525 nm,表观摩尔吸光系数ε525=1.32×105 L/(mol·cm),IO-3浓度在0~30 μg/25 mL范围内服从比尔定律. 方法用于碘盐和生物样品中碘的测定,结果满意. 相似文献
6.
采用疏水性多孔滤膜对水样进行气液分离预处理,优化的预处理条件为:加入抗氧化剂除掉体系中带入的氧,设置加热温度为90℃,加热时间为60 min,50%(体积分数)磷酸溶液总量为20 mL(单次加酸量为2 mL)。采用亚甲基蓝分光光度法测定所得溶液中硫化物的含量。结果表明,硫化物标准曲线的线性范围为0.050~0.700 mg·L^(-1),检出限为0.003 mg·L^(-1)。方法用于测定有证标准物质,测定值在认定值的不确定度范围内,相对误差为-1.9%~-1.6%;按照标准加入法对实际样品进行回收试验,回收率为90.6%~95.0%,测定值的相对标准偏差(n=6)为2.5%~4.6%。 相似文献
7.
8.
甲基蓝双波长光度法测定阿米卡星 总被引:6,自引:0,他引:6
在酸性条件下,甲基蓝(MB)与阿米卡星(AMK)反应,生成蓝色离子缔合物,最大吸收波长和负吸收波长分别位于616 nm和676 nm,正负峰吸光度绝对值之和与AMK的浓度线性相关,AMK的浓度在0~1.5×10~(-5)mol·L~(-1)范围内遵从比耳定律,表观摩尔吸光系数ε为7.28×10~4L·mol~(-1)·cm~(-1),据此建立了测定阿米卡星的甲基蓝双波长光度法。方法用于市售药物及人体尿液中阿米卡星含量的测定,结果满意。 相似文献
9.
10.
11.
《Analytical letters》2012,45(11-12):2587-2600
Abstract A sensitive and rapid automated method has been developed for the selective analysis of acid extractable sulfide in environmental samples by combining gas dialysis separation techniques with methylene blue detection procedures. Acid extractable sulfide is separated from the sample matrix by the gas dialysis membrane and subsequently trapped in a dilute sodium hydroxide receiving stream. This stream is reacted with N, N-dimethyl-p-phenylenediamine and ferric chloride to produce methylene blue which is then quantitated colorimetrically at 660 nm. For standards and nonturbid environmental samples, there is good agreement between the results obtained by this procedure and the standard methylene blue method. The effect of interferences on the accurate determination of sulfide by both methods was also examined and it was found that cupric ions significantly interfered with sulfide estimation. To obtain adequate sulfide recoveries in tap water and environmental samples ascorbic acid must be added as an antioxidant. A detection limit of 2 μg/L of sulfide has been obtained using this procedure. 相似文献
12.
《Analytical letters》2012,45(9):1643-1655
Abstract A Kinetic spectrophotometric method for the determination of ultra-trace amounts of lead(II) is described. This method is based on the catalytic action of this ion on the reduction of resazurin by sulfide. The course of the chemical reaction is followed spectrophotometrically by the measurement of reduction in absorbance of resazurin at 605 nm. The calibration range of Pb(II) is dependent on the sulfide concentration. With this method 1 ng m1?1 lead can be detected. The method is used for determination of Pb(II) in KNO3 (Fluka) and in water. 相似文献
13.
采用基于误差传递规律的手机比色法测定亚甲基蓝溶液,根据颜色三原色值RGB与灰度值Gr之间的关系,通过标准差传递公式的运算,从理论上证实了间接测量法的可行性。分析了不同光照环境对采集照片质量的影响,将3款不同型号的手机作为采样工具进行对比。结果表明,间接测量法的精密度显著提高,3款手机图片颜色的间接测量值XR、XG、XB与亚甲基蓝质量浓度C之间的变化趋势一致,其中XB与质量浓度C成正比,据此建立了亚甲基蓝质量浓度测定的新方法。该方法对样品测定的相对标准偏差为2.7%~4.8%,加标回收率为91.3%~101%,其稳定性、精密度和准确度均符合测定需求。 相似文献
14.
15.
16.
17.
硫化物的快速分光光度法测定 总被引:8,自引:0,他引:8
提出了测定微量硫化物的快速亚甲蓝分光光度法,实验结果表明,在硫酸溶液中,K2Cr2O7+对二甲氨基苯胺+S^-2迅速显色反应形成亚甲蓝,表现摩尔吸收系数为4.06×10^4L.mol^-1.cm^-1;最大吸收波长为664nm;线性范围为0~0.8mg/L,实验了采用全差示光度法直接测定水中硫化物的条件,用于某江水中21.6μg/L硫化物测定时,相对标准偏差为3.2%(n=6);试样的标准加入回收 相似文献