首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
To date, poly(vinyl chloride) (PVC) is the most used polymer in the design of ion selective electrode (ISE) membranes. This paper is focused on the use of sulfonated poly(ether ether ketone) (SPEEK) as an alternative material to PVC for the design of ISEs. SPEEK of the desired degree of sulfonation is synthesized from poly(ether ether ketone) (PEEK). An NH4+-ISE has been chosen as a model electrode to study the efficiency of SPEEK as polymer matrix of the membrane. The material was evaluated in ionophore free ion exchanger membranes as well as in ion-selective electrodes membranes containing nonactine as ionophore. Analytical performance parameters of the prepared electrodes were evaluated. The electrodes show a slope between 50 and 60 mV dec−1 depending on both the calibration medium and the membrane composition. A linear range of response between 10−4 and 1.0 M and a lifetime of 1-2 months were obtained. The interferences of cations such us Ca2+, Na+, Li+ and K+ over the prepared ISEs are studied as well. Although the plasticizer in the SPEEK based membrane matrix is not necessary, its presence improves the sensibility. This makes SPEEK a good potential choice over alternative membrane matrices reported in the literature and a promising platform for the establishment of membrane components.  相似文献   

2.
《Analytical letters》2012,45(10):1541-1555
Abstract

Three types of PVC matrix membrane ion-selective electrodes (ISEs) are described. These are based on membranes containing nitron thiocyanate with 2-nitro-phenyl phenyl ether, 2-nitrophenyl phenyl ether alone and tetraphenylarsonium thiocyanate with 2-nitrophenyl octyl ether. Each type is conditioned and stored in 0.1M sodium thiocyanate. The first two electrodes have been evaluated for thiocyanate and perchlorate response and the best linear long range (linear range down to 2.5×10?5M) response was obtained for perchlorate. The third electrode is suitable as a periodate ISE with linear calibration range down to 2×10?4M. The plasticized (2-nitrophenyl phenyl ether) PVC electrode for thiocyanate and perchlorate had a much longer pH interference free range (1.5–12.5) than either of the other electrodes.  相似文献   

3.
The analytical performance of the clay paste electrode and graphene paste electrode was compared using square wave voltammetry (SWV) and cyclic voltammetry (CV). The comparison was made on the basis of a paracetamol (PA) determination on both working electrodes. The influence of pH and SWV parameters was investigated. The linear concentration ranges were found to be 6.0 × 10−7–3.0 × 10−5 and 2.0 × 10−6–8.0 × 10−5 mol L−1 for clay paste electrode (ClPE) and graphene paste electrode (GrPE), respectively. The detection and quantification limits were calculated as 1.4 × 10−7 and 4.7 ×10−7 mol L−1 for ClPE and 3.7 × 10−7 and 1.2 × 10−6 mol L−1 for GrPE, respectively. Developed methods were successfully applied to pharmaceutical formulations analyses. Scanning electron microscopy and energy-dispersive X-ray spectroscopy were used to characterize ClPE and GrPE surfaces. Clay composition was examined with wavelength dispersive X-ray (WDXRF).  相似文献   

4.
The effect of different plasticizers in the sensing membrane on the performance of a surfactant ISE based on a PVC membrane with no added ion-exchanger was investigated. o-nitrophenyl octyl ether (NPOE), o-nitrophenyl decyl ether (NPDE), o-nitrophenyl dodecyl ether (NPDOE) and o-nitrophenyl tetradecyl ether (NPTE) were used as plasticizers. Electrodes based on NPDE, NPDOE and NPTE produced better results than NPOE-plasticized PVC membrane electrodes in terms of low detection limits. Electrodes based on NPDE, NPDOE and NPTE displayed a Nernstian slope in the concentration range of 10–6 to 10–2M. NPOE-plasticized PVC membrane electrodes displayed a Nernstian slope in the concentration range of 10–5 to 10–2M. The three electrodes other than the NPOE-plasticized PVC membrane electrode showed a similar performance to that of the NPOE-plasticized PVC membrane electrode concerning low detection limits and slope sensitivity. The four electrodes examined in this study are excellently selective for the dodecyltrimethylammonium ion over inorganic anions, but interference from other cationic surfactants such as tetradecyltrimethylammonium ions is significant. With respect to slope sensitivity, selectivity, response time and pH effect, the four electrodes showed a similar performance.  相似文献   

5.
《Electroanalysis》2017,29(3):739-747
Most commercially available fluorous polymers are ill suited for the fabrication of ion‐selective electrode (ISE) membranes. Therefore, we synthesized semifluorinated polymers for this purpose. Ionophore‐free ion‐exchanger electrodes made with these polymers show a selectivity range (≈14 orders of magnitude) that is nearly as wide as found previously for liquid fluorous ion‐exchanger electrodes. These polymers were also used to construct ISE membranes doped with fluorophilic silver ionophores. While the resulting ISEs were somewhat less selective than their fluorous counterparts, the semifluorinated polymers offer the advantage that they can be doped both with fluorophilic ionophores and traditional lipophilic ionophores, such as the silver ionophore Cu(II)‐I (o ‐xylylenebis[N,N ‐diisobutyldithiocarbamate]). We also cross‐linked these polymers, producing very durable membranes that retained broad selectivity ranges. K+ ISEs made with the cross‐linked semifluorinated polymer and the ionophore valinomycin showed selectivities similar to those of PVC membrane ISEs but with a superior thermal stability, the majority of the electrodes still giving a theoretical (Nernstian) response after exposure to a boiling aqueous solution for 10 h.  相似文献   

6.
A novel molecularly imprinted polymer (MIP) has been developed based on a simple and sustainable strategy for the selective determination of citalopram (CTL) using screen-printed carbon electrodes (SPCEs). The MIP layer was prepared by electrochemical in situ polymerization of the 3-amino-4 hydroxybenzoic acid (AHBA) functional monomer and CTL as a template molecule. To simulate the polymerization mixture and predict the most suitable ratio between the template and functional monomer, computational studies, namely molecular dynamics (MD) simulations, were carried out. During the experimental preparation process, essential parameters controlling the performance of the MIP sensor, including CTL:AHBA concentration, number of polymerization cycles, and square wave voltammetry (SWV) frequency were investigated and optimized. The electrochemical characteristics of the prepared MIP sensor were evaluated by both cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) techniques. Based on the optimal conditions, a linear electrochemical response of the sensor was obtained by SWV measurements from 0.1 to 1.25 µmol L−1 with a limit of detection (LOD) of 0.162 µmol L−1 (S/N = 3). Moreover, the MIP sensor revealed excellent CTL selectivity against very close analogues, as well as high imprinting factor of 22. Its applicability in spiked river water samples demonstrated its potential for adequate monitoring of CTL. This sensor offers a facile strategy to achieve portability while expressing a willingness to care for the environment.  相似文献   

7.
Developing a porous separation membrane that can efficiently separate oil–water emulsions still represents a challenge. In this study, nanofiber membranes with polydopamine clusters polymerized and embedded on the surface were successfully constructed using a solution blow-spinning process. The hierarchical surface structure enhanced the selective wettability, superhydrophilicity in air (≈0°), and underwater oleophobicity (≈160.2°) of the membrane. This membrane can effectively separate oil–water emulsions, achieving an excellent permeation flux (1552 Lm−2 h−1) and high separation efficiency (~99.86%) while operating only under the force of gravity. When the external driving pressure was increased to 20 kPa, the separation efficiency hardly changed (99.81%). However, the permeation flux significantly increased to 5894 Lm−2 h−1. These results show that the as-prepared polydopamine nanocluster-embedded nanofiber membrane has an excellent potential for oily wastewater treatment applications.  相似文献   

8.
A rapid and sensitive technique for frauds determination in vanilla flavors was developed. The method comprises separation by liquid chromatography followed by an electrochemical detection using a homemade screen-printed carbon electrode modified with aluminium-doped zirconia nanoparticles (Al-ZrO2-NPs/SPCE). The prepared nanomaterials (Al-ZrO2-NPs) were characterized by using X-ray diffraction (XRD), transmission electron microscopy (TEM) and energy dispersive X-ray (EDX). This method allows for the determination of six phenolic compounds of vanilla flavors, namely, vanillin, p-hydroxybenzoic acid, p-hydroxybenzaldehyde, vanillyl alcohol, vanillic acid and ethyl vanillin in a linear range between 0.5 and 25 µg g−1, with relative standard deviation values from 2.89 to 4.76%. Meanwhile, the limits of detection and quantification were in the range of 0.10 to 0.14 µg g−1 and 0.33 to 0.48 µg g−1, respectively. In addition, the Al-ZrO2-NPs/SPCE method displayed a good reproducibility, high sensitivity, and good selectivity towards the determination of the vanilla phenolic compounds, making it suitable for the determination of vanilla phenolic compounds in vanilla real extracts products.  相似文献   

9.
Herein, the spectral and electrochemical characterizations of three different substituted N-phthalimide azo-azomethine (NAA) dyes (L) containing an o-hydroxy group and their NAA-M(II) chelates [M(II): Cu, Ni, Co, Pb] were reported by using UV–Vis and fluorescence spectroscopy and potentiometric and voltamperometric techniques. The pK value of the dyes as well as the stoichiometry and stability of the NAA-metal chelates were studied, and the stoichiometry was found to be mostly 1:2 (ML2) with high complex stability constant values. The sensor activity of N-phthalimide azo-azomethine derivatives toward pH and metal ions has been also investigated and tested for indicator application in acid–base analysis and detection of Cu(II) ions in real samples of surface river water using voltamperometric detection. The results showed that one of the ligands possesses the highest electrochemical response upon binding to copper ions and could be successfully used in the analysis of copper in water at a concentration range of the analyte from 3.7 × 10−7 to 5.0 × 10−6 mol L−1, with analytical characteristics of the method being Sr = 1.5%, LOD = 3.58 µg L−1 and LOQ =11.9 µg L−1  相似文献   

10.
2,4-dichlorophenoxyacetic acid (2,4-D) is an auxinic herbicide used to control broadleaf weeds. It is also a threatening factor for not only aquatic life but also human health due to its genotoxicity and endocrine disruptive property. Herein, the interaction between 2,4-D and double stranded DNA was investigated by using single-use pencil graphite electrodes (PGE) in combination with electrochemical techniques. The detection mechanism was based on the monitoring of the changes at the guanine oxidation signal obtained before/after surface-confined interaction of 2,4-D and DNA at the surface of PGE. The electrochemical characterization of the interaction was studied by using microscopic and electrochemical techniques. The response obtained by interaction in the presence of another herbicide, glyphosate, which is widely used with 2,4-D for weed control, was compared to the one occurred in the presence of 2,4-D. Electrochemical monitoring of the interaction between the herbicide whose active molecule was 2,4-D and DNA was also investigated. The detection (LOD) and quantification limits (LOQ) for 2,4-D and the herbicide could be obtained in the linear concentration ranges of 30–70 µg/mL and 10–30 µg/mL, respectively and LOD and LOQ values were found to be 2.85 and 9.50 µg/mL for both 2,4-D and the herbicide. The sensitivity of the biosensor was calculated as 0.087 µA.mL / µg.cm2 .This is the first study in literature by means of not only voltammetric detection of 2,4-D and DNA interaction but also the herbicide-DNA interaction at the surface of PGE based on the changes at the guanine signal.  相似文献   

11.
Cobalt(II) porphyrazine is synthesized and studied as an active component of a polyvinyl chloride plasticized membrane ion-selective electrodes (ISEs). It is established that regardless of their structure, ISEs are sensitive to iodide. The introduction to the ISE of an ionic additive, ionic liquid 1,3-dihexadecylimidazolium chloride, significantly improves the electrochemical characteristics: the slope of the electrode function reaches ?(57 ± 1) mV/dec, cmin = 8.3 × 10–6 M. Solid-state screen-printed electrodes the surfaces of which are modified by a 1: 4 mixture of cobalt(II) porphyrazine and ionic liquid 1,3-dihexadecylimidazolium chloride demonstrate satisfactory electrochemical characteristics: the slope of the electrode function is ?(56 ± 4) mV/dec and cmin = 2.5 × 10–5 M. The potentiometric selectivity of the ISEs for iodide is studied. It is found that the effect of lipophilic interfering ions is significantly lower for solid state ISEs than for plasticized membrane electrodes.  相似文献   

12.
The membrane is a crucial component of Zn slurry–air flow battery since it provides ionic conductivity between the electrodes while avoiding the mixing of the two compartments. Herein, six commercial membranes (Cellophane™ 350PØØ, Zirfon®, Fumatech® PBI, Celgard® 3501, 3401 and 5550) were first characterized in terms of electrolyte uptake, ion conductivity and zincate ion crossover, and tested in Zn slurry–air flow battery. The peak power density of the battery employing the membranes was found to depend on the in-situ cell resistance. Among them, the cell using Celgard® 3501 membrane, with in-situ area resistance of 2 Ω cm2 at room temperature displayed the highest peak power density (90 mW cm−2). However, due to the porous nature of most of these membranes, a significant crossover of zincate ions was observed. To address this issue, an ion-selective ionomer containing modified poly(phenylene oxide) (PPO) and N-spirocyclic quaternary ammonium monomer was coated on a Celgard® 3501 membrane and crosslinked via UV irradiation (PPO-3.45 + 3501). Moreover, commercial FAA-3 solutions (FAA, Fumatech) were coated for comparison purpose. The successful impregnation of the membrane with the anion-exchange polymers was confirmed by SEM, FTIR and Hg porosimetry. The PPO-3.45 + 3501 membrane exhibited 18 times lower zincate ions crossover compared to that of the pristine membrane (5.2 × 10−13 vs. 9.2 × 10−12 m2 s−1). With low zincate ions crossover and a peak power density of 66 mW cm−2, the prepared membrane is a suitable candidate for rechargeable Zn slurry–air flow batteries.  相似文献   

13.
For the determination of Cr(VI) concentrations with a potentiometric ion-selective electrode (ISE), ionophore-immobilized membranes were prepared by ultraviolet (UV)-induced graft polymerization followed by chemical treatment. Novel ionophores comprising various amine structures were immobilized onto poly(vinyl chloride) (PVC) matrixes, and these were examined to determine Cr(VI) selectively. Of the three ionophores examined in this study, the membranes with N,N,N,N-tetrakis(3-aminopropyl)-1,4-butanediamine (DABAm4) exhibited the highest Cr(VI) ion selectivity in both extraction and potentiometry experiments. The plasticizer in the membrane was optimized as 1.0 ml o-nitrophenyl octyl ether (NPOE)/g PVC to form diffusible channels. The potentiometric studies revealed that the performance of DABAm4-immobilized PVC was equivalent to that of mobile ionophores in supported liquid membranes (SLMs). A reproducible response of Cr(VI) was attained within a response time of 1 s in the range of 2.16 × 10−6 to 0.1 M, using the membrane prepared in this study. The selectivity for the Cr(VI) ion against the other interfering ions was compared reasonably between a solvent extraction and potentiometry. The long-term response of the Cr(VI) ISE showed slight deterioration over a continuous operation for 6 months, while the detection limit slightly decreased due to the leaching-out of the plasticizer. The ISE along with the DABAm4 immobilized membrane showed a higher Cr(VI) ion selectivity and more stable response under long-term usage than ISEs with typical SLMs.  相似文献   

14.
Dinaphthyl macrocyclic polyethers were synthesized and used as neutral carriers for preparing primary amine drug sensitive PVC membrane electrodes. Contrary to the ion-associate based electrodes, which show an excellent potentiometric response to quaternary ammonium ions and the like, but a very poor response to primary amines, the macrocyclic polyether-based electrodes showed potentiometric response characteristics with primary amines preferred. Dinaphthyl macrocyclic polyether-based electrodes are superior to those based on common macrocyclic polyethers for their potentiometric selectivity coefficients much lower than those of the latter. The main characteristics of a dinaphthyl-20-crown-6-based benzyl amine sensitive electrode are as follows: linear response range, 4.2 × 10–5 – 1.0 ×10–1 M; slope, 51.3 mV/decade; and detection limit, 4.6 × 10–6 M. A mexiletine sensitive electrode was prepared using dinaphthyl-23-crown-7 with following performance features: linear response range, 2.0 × 10–5 – 1.0 ×10–1 M; slope, 52.1mV/decade; and detection limit, 5.0 × 10–6 M.  相似文献   

15.
《Electroanalysis》2017,29(6):1635-1642
Our studies are focused on the development of novel potentiometric sensors for the quantification of the neurotransmitter serotonin. Therefore, ion‐selective electrodes based on plasticized PVC membranes are applied. The electroactive part of the membrane consists of an ion pair complex formed between the protonated analyte and a carborane anion [Co(1,2‐C2B9H11)2]. The analytical performance of the electrode was studied regarding sensitivity, concentration range, limit of detection and potential stability. The ion‐selective electrodes were optimized with respect to the material of the transducing element, as well as the membrane thickness and its composition. Stable, all solid state ISEs could be developed, using the non‐polar plasticizer NPOE and a graphite rod with high surface area as transducing element. We thus achieved a near Nernstian response over three decades of concentration (2.25⋅10‐5‐1.00⋅10‐2 M) and a limit of detection in the μ‐molar range for the optimized electrodes. The electrodes could successfully be miniaturized using carbon based screen printed electrodes.  相似文献   

16.
Peper S  Gonczy C  Runde W 《Talanta》2005,67(4):713-717
A new strategy for improving the robustness of membrane-based ion-selective electrodes (ISEs) is introduced based on the incorporation of microsphere-immobilized ionophores into plasticized polymer membranes. As a model system, a Cs+-selective electrode was developed by doping ethylene glycol-functionalized cross-linked polystyrene microspheres (P-EG) into a plasticized poly(vinyl chloride) (PVC) matrix containing sodium tetrakis-[3,5-bis(trifluoromethyl)phenyl] borate (TFPB) as the ion exchanger. Electrodes were evaluated with respect to Cs+ in terms of sensitivity, selectivity, and dynamic response. ISEs containing P-EG and TFPB that were plasticized with 2-nitrophenyl octyl ether (NPOE) yielded a linear range from 10−1 to 10−5 M Cs+, a slope of 55.4 mV/decade, and a lower detection limit (log aCs) of −5.3. In addition, these membranes also demonstrated superior selectivity over Li+, Na+, and alkaline earth metal ion interferents when compared to analogous membranes plasticized with bis(2-ethylhexyl) sebacate (DOS) or membranes containing a lipophilic, mobile ethylene glycol derivative (ethylene glycol monooctadecyl ether (U-EG)) as ionophore.  相似文献   

17.
《Electroanalysis》2006,18(11):1055-1062
The potentiometric response characteristics of electrodes based on PVC membranes containing novel polyethylene glycols (PEGs) with tributyltin carboxylate end groups as ionophores for chloride ions were studied in 0.1 M HEPES solution, at the spontaneous pH. The effects of solvent mediator, amount of cationic additive, amount of ionophore and PEG chain length on the behavior of the sensors were investigated. The membranes with the best composition responded to chloride concentration in a linear range from 10?4 to 10?1 M Cl? with a nearly Nernstian slope and a detection limit of 6.5×10?5 M. The sensor showed a short response time (<25 s) in the whole concentration range and an operational lifetime of about one week for the most performing PVC membranes. In comparison with ISEs based on anion exchangers the interferences from the more lipophilic anions were greatly reduced, as inferable by the selectivity coefficients determined with the matched potential method at chloride concentration of 3.0×10?3 M.  相似文献   

18.
A β-cyclodextrin-decorated magnetic activated carbon adsorbent was prepared and characterized using various analytical techniques (X-ray diffraction (XRD), scanning electron microscopy–electron diffraction spectroscopy (SEM-EDS) and transmission electron microscopy (TEM)), and the adsorbent was used in the development of a magnetic solid-phase microextraction (MSPE) method for the preconcentration of estrone, β-estradiol, hydrocortisone and progesterone in wastewater and river water samples. This method was optimized using the central composite design in order to determine the experimental parameters affecting the extraction procedure. The quantification of hormones was achieved using high-performance liquid chromatography equipped with a photodiode array detector (HPLC-DAD). Under optimum conditions, the linearity ranged from 0.04 to 300 µg L−1 with a correlation of determinations of 0.9969–0.9991. The limits of detection and quantification were between 0.01–0.03 and 0.033–0.1 µg L−1, with intraday and interday precisions at 1.1–3.4 and 3.2–4.2. The equilibrium data were best described by the Langmuir isotherm model, and high adsorption capacities (217–294 mg g−1) were obtained. The developed procedure demonstrated high potential as an effective technique for use in wastewater samples without significant interferences, and the adsorbent could be reused up to eight times.  相似文献   

19.
A flow cell with a radial distribution of four all-solid-state ion selective electrodes (ISEs), or alternatively three ISEs and one reference electrode, was designed and optimized for mass production. The radial distribution of the electrodes reduces the cell volume and is expected to minimize cross-contamination between different electrodes. Two different cell prototypes were developed and tested for all-solid-state K+-ISEs based on a solvent polymeric ion-selective membrane (ISM) and a conducting polymer, poly(3,4-ethylenedioxythiophene), as solid internal contact. In the first prototype, PEDOT was electropolymerized from an aqueous solution of the monomer and the doping ion salt, sodium polystyrenesulfonate (NaPSS). The second prototype employed an aqueous dispersion of PEDOT(PSS) that is commercially available (Baytron P, Bayer AG). Compared to electrochemical synthesis, solution casting of the polymer dispersion was found to be a more advantageous method to deposit the conducting polymer layer aiming at mass production. The resulting prototypes of the flow cell had a small volume (ca. 17-37 μl), which makes them suitable for application in clinical analysis.  相似文献   

20.
Two diaza-crown ether compounds were synthesized and evaluated as Ag+-selective carriers in polyvinylchloride (PVC) membrane electrodes of solid-state type. The all-solid-state PVC membrane electrode based on N,N-Dibenzyl-dibenzo-diaza-18-crown-6 exhibited a super-Nernstian response (75±10mV per decade) over the concentration range of 1×10–1 to 7×10–6M of Ag+ ion and a detection limit of 3×10–6M, at a wide range of pH (pH 4–7). The response time of the electrode was fast (less than 10s), and it can be used for three months without any significant deviation in potential. The proposed all-solid-state PVC membrane electrodes revealed high selectivity toward Ag+ ion with respect to alkali, alkaline earth, heavy and transition metal ions. A flow-through cell of all-solid-state PVC membrane Ag+-selective electrode based on N,N-Dibenzyl-dibenzo-diaza-18-crown-6 has also been prepared and applied for flow-injection analysis of Ag+ ion in solution.  相似文献   