首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 250 毫秒
1.
Modulation masking: effects of modulation frequency, depth, and phase   总被引:1,自引:0,他引:1  
Modulation thresholds were measured for a sinusoidally amplitude-modulated (SAM) broadband noise in the presence of a SAM broadband background noise with a modulation depth (mm) of 0.00, 0.25, or 0.50, where the condition mm = 0.00 corresponds to standard (unmasked) modulation detection. The modulation frequency of the masker was 4, 16, or 64 Hz; the modulation frequency of the signal ranged from 2-512 Hz. The greatest amount of modulation masking (masked threshold minus unmasked threshold) typically occurred when the signal frequency was near the masker frequency. The modulation masking patterns (amount of modulation masking versus signal frequency) for the 4-Hz masker were low pass, whereas the patterns for the 16- and 64-Hz maskers were somewhat bandpass (although not strictly so). In general, the greater the modulation depth of the masker, the greater the amount of modulation masking (although this trend was reversed for the 4-Hz masker at high signal frequencies). These modulation-masking data suggest that there are channels in the auditory system which are tuned for the detection of modulation frequency, much like there are channels (critical bands or auditory filters) tuned for the detection of spectral frequency.  相似文献   

2.
These experiments examine how comodulation masking release (CMR) varies with masker bandwidth, modulator bandwidth, and signal duration. In experiment 1, thresholds were measured for a 400-ms, 2000-Hz signal masked by continuous noise varying in bandwidth from 50-3200 Hz in 1-oct steps. In one condition, using random noise maskers, thresholds increased with increasing bandwidth up to 400 Hz and then remained approximately constant. In another set of conditions, the masker was multiplied (amplitude modulated) by a low-pass noise (bandwidth varied from 12.5-400 Hz in 1-oct steps). This produced correlated envelope fluctuations across frequency. Thresholds were generally lower than for random noise maskers with the same bandwidth. For maskers less than one critical band wide, the release from masking was largest (about 5 dB) for maskers with low rates of modulation (12.5-Hz-wide low-pass modulator). It is argued that this release from masking is not a "true" CMR but results from a within-channel cue. For broadband maskers (greater than 400 Hz), the release from masking increased with increasing masker bandwidth and decreasing modulator bandwidth, reaching an asymptote of 12 dB for a masker bandwidth of 800 Hz and a modulator bandwidth of 50 Hz. Most of this release from masking can be attributed to a CMR. In experiment 2, the modulator bandwidth was fixed at 12.5 Hz and the signal duration was varied. For masker bandwidths greater than 400 Hz, the CMR decreased from 12 to 5 dB as the signal duration was decreased from 400 to 25 ms.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

3.
Comparison of auditory filter shapes derived with three different maskers   总被引:1,自引:0,他引:1  
Auditory filter shapes were derived for three different masker types, by measuring threshold for a 1-kHz sinusoidal signal masked by: (a) a noise with a spectral notch of variable width; (b) two tones with variable frequency separation; and (c) a noise with a sinusoidally rippled spectrum with variable ripple density. In each case the masker spectrum was symmetric about the signal frequency, the signal level was fixed, and the masker level was varied to determine threshold using an adaptive, two-alternative, forced-choice procedure. Both simultaneous and forward masking were used. The auditory filter shapes derived from the data were broader in simultaneous masking than in forward masking for all three masker types. In simultaneous masking the derived filters were similar for the three masker types, although there was a tendency for the filters derived from the rippled-noise data to be broader than those for the other maskers. In forward masking the auditory filters derived from the data for three masker types differed considerably in bandwidth and the slope of the filter skirts, and in that a portion of the rippled-noise filter was negative valued. The results are consistent with the idea that suppression has the effect of enhancing frequency selectivity, and that this effect is revealed in forward but not in simultaneous masking. However, the degree and nature of the enhancement differs for different masker types.  相似文献   

4.
The first part of this paper presents several experiments on signal detection in temporally modulated noise, yielding a general approach toward the concept of comodulation masking release (CMR). Measurements were made on masked thresholds of both long- and short-duration, narrow-band signals presented in a 100% sinusoidally amplitude-modulated (SAM) noise masker (modulation frequency 32 Hz), as a function of masker bandwidth from 1/3 oct up to 13/3 octs, while the masker band was geometrically centered at signal frequency. With the short-duration signals placed in the valley of the masker, a substantial CMR (i.e., a decrease of masked threshold with increasing masker bandwidth) was found, whereas for the long-duration signals CMR was smaller. Furthermore, investigations were carried out to determine whether CMR changes when the bandwidth of the signals, consisting of bandpass impulse responses, is increased. The data indicate that substantial CMR remains even when all masker bands contain a signal component, thus minimizing across-channel differences. This finding is not in line with current models accounting for the CMR phenomenon. The second part of this paper concerns signal detection in spectrally shaped noise. Also investigated was whether release from masking occurs for the detection of a pure-tone signal at a valley or a peak of a simultaneously presented masking noise with a sinusoidally rippled power spectrum, when this masker was preceded and followed by a second noise (temporal flanking burst) with an identical spectral shape as the on-signal noise. Similar to CMR effects for temporal modulations, the data indicate that coshaping masking release (CSMR) occurs when the signal is placed in a valley of the spectral envelope of the masker, whereas no release from masking is found when the signal is placed at a peak of the spectral envelope of the masker. The implications of these experiments for measures of spectral and temporal resolution are discussed.  相似文献   

5.
The role of harmonicity in masking was studied by comparing the effect of harmonic and inharmonic maskers on the masked thresholds of noise probes using a three-alternative, forced-choice method. Harmonic maskers were created by selecting sets of partials from a harmonic series with an 88-Hz fundamental and 45 consecutive partials. Inharmonic maskers differed in that the partial frequencies were perturbed to nearby values that were not integer multiples of the fundamental frequency. Average simultaneous-masked thresholds were as much as 10 dB lower with the harmonic masker than with the inharmonic masker, and this difference was unaffected by masker level. It was reduced or eliminated when the harmonic partials were separated by more than 176 Hz, suggesting that the effect is related to the extent to which the harmonics are resolved by auditory filters. The threshold difference was not observed in a forward-masking experiment. Finally, an across-channel mechanism was implicated when the threshold difference was found between a harmonic masker flanked by harmonic bands and a harmonic masker flanked by inharmonic bands. A model developed to explain the observed difference recognizes that an auditory filter output envelope is modulated when the filter passes two or more sinusoids, and that the modulation rate depends on the differences among the input frequencies. For a harmonic masker, the frequency differences of adjacent partials are identical, and all auditory filters have the same dominant modulation rate. For an inharmonic masker, however, the frequency differences are not constant and the envelope modulation rate varies across filters. The model proposes that a lower variability facilitates detection of a probe-induced change in the variability, thus accounting for the masked threshold difference. The model was supported by significantly improved predictions of observed thresholds when the predictor variables included envelope modulation rate variance measured using simulated auditory filters.  相似文献   

6.
The temporal course of masking and the auditory filter shape   总被引:1,自引:0,他引:1  
Recent experiments have shown that frequency selectivity measured in tone-on-tone simultaneous masking improves with increasing delay of a brief signal relative to the onset of a longer duration gated masker. To determine whether a similar improvement occurs for a notched-noise masker, threshold was measured for a 20-ms signal presented at the beginning, the temporal center, or the end of the 400-ms masker (simultaneous masking), or immediately following the masker (forward masking). The notch width was varied systematically and the notch was placed both symmetrically and asymmetrically about the 1-kHz signal frequency. Growth-of-masking functions were determined for each temporal condition, for a noise masker without a spectral notch. These functions were used to express the thresholds from the notched-noise experiment in terms of the level of a flat-spectrum noise which would produce the same threshold. In simultaneous masking the auditory filter shapes derived from the transformed data did not change significantly with signal delay, suggesting that the selectivity of the auditory filter does not develop over time. In forward masking the auditory filter shapes were sharper than those for simultaneous masking, particularly on the high-frequency side, which was attributed to suppression.  相似文献   

7.
The present study sought to clarify the role of non-simultaneous masking in the binaural masking level difference for maskers that fluctuate in level. In the first experiment the signal was a brief 500-Hz tone, and the masker was a bandpass noise (100-2000 Hz), with the initial and final 200-ms bursts presented at 40-dB spectrum level and the inter-burst gap presented at 20-dB spectrum level. Temporal windows were fitted to thresholds measured for a range of gap durations and signal positions within the gap. In the second experiment, individual differences in out of phase (NoSπ) thresholds were compared for a brief signal in a gapped bandpass masker, a brief signal in a steady bandpass masker, and a long signal in a narrowband (50-Hz-wide) noise masker. The third experiment measured brief tone detection thresholds in forward, simultaneous, and backward masking conditions for a 50- and for a 1900-Hz-wide noise masker centered on the 500-Hz signal frequency. Results are consistent with comparable temporal resolution in the in phase (NoSo) and NoSπ conditions and no effect of temporal resolution on individual observers' ability to utilize binaural cues in narrowband noise. The large masking release observed for a narrowband noise masker may be due to binaural masking release from non-simultaneous, informational masking.  相似文献   

8.
Forward- and simultaneous-masked thresholds were measured at 0.5 and 2.0 kHz in bandpass maskers as a function of masker bandwidth and in a broadband masker with the goal of estimating psychophysical suppression. Suppression was operationally defined in two ways: (1) as a change in forward-masked threshold as a function of masker bandwidth, and (2) as a change in effective masker level with increased masker bandwidth, taking into account the nonlinear growth of forward masking. Subjects were younger adults with normal hearing and older adults with cochlear hearing loss. Thresholds decreased as a function of masker bandwidth in forward masking, which was attributed to effects of suppression; thresholds remained constant or increased slightly with increasing masker bandwidth in simultaneous masking. For subjects with normal hearing, slightly larger estimates of suppression were obtained at 2.0 kHz rather than at 0.5 kHz. For hearing-impaired subjects, suppression was reduced in regions of hearing loss. The magnitude of suppression was strongly correlated with the absolute threshold at the signal frequency, but did not vary with thresholds at frequencies remote from the signal. The results suggest that measuring forward-masked thresholds in bandlimited and broadband maskers may be an efficient psychophysical method for estimating suppression.  相似文献   

9.
Forward masking, as measured behaviorally, is defined as an increase in a signal's detection threshold resulting from a preceding masker. Previously, forward masking in the auditory nerve has been measured as a reduction in the neural response to a signal when preceded by a masker. However, detection threshold depends on both the magnitude of the response to the signal and the variance of the response. Thus changes in detectability cannot be inferred from response reduction alone. Relkin and Pelli (1987) have described a two-interval forced-choice procedure that may be used to measure the threshold for the detection of a probe signal in recordings of spike counts in single auditory neurons. These methods have been used to study the forward masking of characteristic frequency probe tones by characteristic frequency maskers as masker intensity was varied. Although the masker does reduce the detectability of the probe tone, it was found that the threshold shifts are much less than those observed behaviorally, particularly for intense maskers. In part, the small threshold shifts can be attributed to the reduction in response variance following the masker, which is the result of the adaptation of spontaneous activity. These results imply that behavioral forward masking must result from suboptimal processing of spike counts from auditory neurons at a location central to the auditory nerve.  相似文献   

10.
This study examined whether increasing the similarity between informational maskers and signals would increase the amount of masking obtained in a nonspeech pattern identification task. The signals were contiguous sequences of pure-tone bursts arranged in six narrow-band spectro-temporal patterns. The informational maskers were sequences of multitone bursts played synchronously with the signal tones. The listener's task was to identify the patterns in a 1-interval 6-alternative forced-choice procedure. Three types of multitone maskers were generated according to different randomization rules. For the least signal-like informational masker, the components in each multitone burst were chosen at random within the frequency range of 200-6500 Hz, excluding a "protected region" around the signal frequencies. For the intermediate masker, the frequency components in the first burst were chosen quasirandomly, but the components in successive bursts were constrained to fall in narrow frequency bands around the frequencies of the components in the initial burst. Within the narrow bands the frequencies were randomized. This masker was considered to be more similar to the signal patterns because it consisted of a set of narrow-band sequences any one of which might be mistaken for a signal pattern. The most signal-like masker was similar to the intermediate masker in that it consisted of a set of synchronously played narrow-band sequences, but the variation in frequency within each sequence was sinusoidal, completing roughly one period in a sequence. This masker consisted of discernible patterns but not patterns that were part of the set of signals. In addition, masking produced by Gaussian noise bursts--thought to produce primarily peripherally based "energetic masking"--was measured and compared to the informational masking results. For the three informational maskers, more masking was produced by the maskers comprised of narrow-band sequences than for the masker in which the frequencies were not constrained to narrow bands. Also, the slopes of the performance-level functions for the three informational maskers were much shallower than for the Gaussian noise masker or for no masker. The findings provided qualified support for the hypothesis that increasing the similarity between signals and maskers, or parts of the maskers, causes greater informational masking. However, it is also possible that the greater masking was a consequence of increasing the number of perceptual "streams" that had to be evaluated by the listener.  相似文献   

11.
Masked thresholds for a 1000-Hz sinusoidal signal were measured as a function of masker level in both forward and simultaneous masking for two types of maskers: a 1000-Hz sinusoid and a narrowband noise, 60-Hz wide, centered at 1000 Hz. In forward masking, the noise masker produced much steeper growth-of-masking functions than the sinusoid. Presenting a contralateral broadband noise "cue" with the forward masker dramatically reduced the slope of masking for the noise masker but did not influence results for the sinusoidal masker. The noise remained the more effective masker. The amount of masking produced by combinations of equally effective narrowband-noise and sinusoidal maskers was compared to that produced by each masker individually with and without the contralateral cue. No additional masking beyond that predicted by energy summation was measured for forward masking. Additional masking beyond energy-sum predictions was measured for analogous conditions in simultaneous masking. Comparisons of results obtained with and without the contralateral cue suggest that signal thresholds in the presence of narrowband-noise forward maskers can reflect nonperipheral auditory processes.  相似文献   

12.
The present study was a follow-up to a pilot study in which it was found that a 500-Hz-wide narrow-band noise (NBN) masker produced more masking than a tonal (T) masker for signal frequencies both above and below the masker frequency. The aim of the present study was to determine to what extent these results were influenced by an interaction of the relatively rapid temporal envelope fluctuations of the NBN and the short (10-ms) duration of the signal. In the first experiment, the masking produced by a regular NBN, a low-noise noise (LNN), and a T was compared. The LNN produced less masking than the NBN, and about as much as the T, suggesting that the inherent amplitude fluctuations in the NBN were largely responsible for the greater masking produced by that masker. In the second experiment, the masking produced by a regular NBN was compared with that by a T for a signal duration of 10 or 200 ms. The difference in masking between the two maskers was reduced or eliminated when the signal duration was 200 ms, because the threshold in the presence of the NBN masker decreased more with increasing signal duration. This could reflect a decreased "confusion" between the signal and the inherent fluctuations of the NBN masker.  相似文献   

13.
We compare psychophysical tuning curves obtained with sinusoidal and narrow-band (50-Hz wide) noise maskers in both simultaneous and forward masking. In one experiment, we examine the effects of different combinations of duration and intensity of the 1-kHz sinusoidal signal. In a second experiment, we compare tuning curves obtained with a sinusoidal signal to those obtained with a noise signal. In both experiments, a narrow-band noise is a more effective simultaneous masker than a sinusoid for masker frequencies near the signal frequency. We argue that this is probably due to the use of different detection cues in the presence of sinusoidal and noise maskers, and that the greater masking produced by the noise is not simply due to its greater variability. As observed in other studies, tuning curves are narrower in forward masking than in simultaneous masking.  相似文献   

14.
15.
The shape of the auditory filter was calculated from binaural masking experiments. Two different types of maskers were used in the study, a masker that was interaurally in phase at all frequencies (No), and a masker with an interaural phase difference of 0 below 500 Hz and of pi above 500 Hz. The test-signal frequency varied between 200 and 800 Hz, and the test signal was presented either monaurally (Sm) or binaurally in antiphase (S pi). By comparing the masked thresholds from the two experimental conditions, the following conclusion can be drawn: The threshold of the test signal is only affected by the masker phase within a narrow frequency range around the test frequency. Thus, for test-signal frequencies well above or below 500 Hz, no influence of the phase transition on the BMLD is observed, and normal masked thresholds for No and N pi maskers are obtained. For test frequencies around 500 Hz, the step in interaural phase difference leads to a decrease in the interaural correlation of the masker within the critical band around the test-signal frequency. This results in strong threshold changes for both monaural and binaural signals. A calculation of the auditory filter shape from the masked threshold values was performed under the assumption that the masked threshold is only dependent on the interaural cross correlation of the masker within the filter band. Using the formula of the EC theory for the relation between masker correlation and BMLD, the experimental data are well described by a trapezoidal filter with an equivalent rectangular bandwidth of 80 to 84 Hz.  相似文献   

16.
This study investigated comodulation detection differences (CDD) for fixed- and roved-frequency maskers. The objective was to determine whether CDD could be accounted for better in terms of energetic masking or in terms of perceptual fusion/segregation related to comodulation. Roved-frequency maskers were used in order to minimize the role of energetic masking, allowing possible effects related to perceptual fusion/segregation to be revealed. The signals and maskers were composed of 30-Hz-wide noise bands. The signal was either comodulated with the masker (A/A condition) or had a temporal envelope that was independent (A/B condition). The masker was either gated synchronously with the signal or had a leading temporal fringe of 200 ms. In the fixed-frequency masker conditions, listeners with low A/A thresholds showed little masking release due to masker temporal fringe and had CDDs that could be accounted for by energetic masking. Listeners with higher A/A thresholds in the fixed-frequency masker conditions showed relatively large CDDs and large masking release due to a masker temporal fringe. The CDDs of these listeners may have arisen, at least in part, from processes related to perceptual segregation. Some listeners in the roved masker conditions also had large CDDs that appeared to be related to perceptual segregation.  相似文献   

17.
Temporal masking of chicks by noise was investigated using a forward-masking paradigm. The temporal separation delta T between the click and the noise ranged from 0.03 to 100 msec. The duration of the noise varied from 3 to 500 msec while its energy remained fixed. For fixed delta T (delta T greater than 3 msec), the masking effect may actually increase for the longer, less intense noises despite the fact that, for long maskers, there is less masker energy near the signal in time. These results are interpreted in terms of the modified version of the running-average hypothesis [M. J. Penner, J. Acoust. Soc. Am. 63, 195--201 (1978)] in which it is argued that the auditory system compresses the intensity of the stimulus prior to integrating it. If the temporal integrator depends on stimulus intensity, then these results may be easily predicted. As an alternative explanation we show that compression may reduce the effective intensity of short maskers to such an extent that they do less masking than the longer ones. Such reduction in masking effectiveness will occur if the time between the masker and the signal is long enough so that the effects of compression and integrator shape do not counterbalance each other.  相似文献   

18.
A series of four experiments was undertaken to ascertain whether signal threshold in frequency-modulated noise bands is dependent upon the coherence of modulation. The specific goal was to determine whether a masking release could be obtained with frequency modulation (FM), analogous to the comodulation masking release (CMR) phenomenon observed with amplitude modulation (AM). It was hypothesized that an across-frequency grouping process might give rise to such an effect. In experiments 1-3, maskers were composed of three noise bands centered on 1600, 2000, and 2400 Hz; these were either comodulated or noncomodulated with respect to both FM and AM. In experiment 1, the modulation was sinusoidal, and the signal was a 2000-Hz pure tone; in experiment 2, the modulation was random, and the signal was an FM noise band centered on 2000 Hz. The results obtained showed that, given sufficient width of modulation, thresholds were lower in a coherent FM masker than in an incoherent FM masker, regardless of the pattern of AM or signal type. However, thresholds in multiband maskers were usually elevated relative to that in a single-band masker centered on the signal. Experiment 3 demonstrated that coherent FM could be discriminated from incoherent FM. Experiment 4 gave similar patterns of results to the respective conditions of experiments 2 and 3, but for an inharmonic masker with bands centered on 1580, 2000, and 2532 Hz. While within-channel processes could not be entirely excluded from contributing to the present results, the experimental conditions were designed to be minimally conducive to such processes.  相似文献   

19.
To assess age-related differences in benefit from masker modulation, younger and older adults with normal hearing but not identical audiograms listened to nonsense syllables in each of two maskers: (1) a steady-state noise shaped to match the long-term spectrum of the speech, and (2) this same noise modulated by a 10-Hz square wave, resulting in an interrupted noise. An additional low-level broadband noise was always present which was shaped to produce equivalent masked thresholds for all subjects. This minimized differences in speech audibility due to differences in quiet thresholds among subjects. An additional goal was to determine if age-related differences in benefit from modulation could be explained by differences in thresholds measured in simultaneous and forward maskers. Accordingly, thresholds for 350-ms pure tones were measured in quiet and in each masker; thresholds for 20-ms signals in forward and simultaneous masking were also measured at selected signal frequencies. To determine if benefit from modulated maskers varied with masker spectrum and to provide a comparison with previous studies, a subgroup of younger subjects also listened in steady-state and interrupted noise that was not spectrally shaped. Articulation index (AI) values were computed and speech-recognition scores were predicted for steady-state and interrupted noise; predicted benefit from modulation was also determined. Masked thresholds of older subjects were slightly higher than those of younger subjects; larger age-related threshold differences were observed for short-duration than for long-duration signals. In steady-state noise, speech recognition for older subjects was poorer than for younger subjects, which was partially attributable to older subjects' slightly higher thresholds in these maskers. In interrupted noise, although predicted benefit was larger for older than younger subjects, scores improved more for younger than for older subjects, particularly at the higher noise level. This may be related to age-related increases in thresholds in steady-state noise and in forward masking, especially at higher frequencies. Benefit of interrupted maskers was larger for unshaped than for speech-shaped noise, consistent with AI predictions.  相似文献   

20.
This study examines how simultaneous masking of a tone by bandlimited noise may be affected by nonlinear interactions among spectral components of the noise. Simultaneous masking patterns (signal threshold versus signal frequency) were obtained with three types of maskers: (A) a narrow-band noise, 50 Hz wide with variable center frequency fv, (B) pairs of narrow-band noises, each band 50 Hz wide with center frequencies fl and fu, and (C) wide-band noise formed by filling the spectral gap between the two bands of (B). The variable frequency fv was set to 1.0, 1.1, 1.2, and 1.3 kHz: fl was fixed at 1.0 kHz, and fu had values of 1.1, 1.2, and 1.3 kHz. In most conditions, the two-band maskers and the wideband maskers produced more masking than would be predicted from the masking produced by the single narrow-band maskers. For certain signal frequencies below the maskers, adding noise to fill the spectral gap of the two-band masker actually resulted in a 3- to 15-dB release from masking. These results reveal factors that may operate to confound modern measures of frequency selectivity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号